Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Hydrogen Sensor for Parabolic Trough Expansion Tanks

The National Renewable Energy Laboratory and Acciona Energy North America are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid. As part of this effort, we are developing a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor design measures hydrogen levels over a wide partial pressure range from 1.33 mbar down to 0.003 mbar with an accuracy of +/-20%. We acquired these results under limited conditions because we measured hydrogen partial pressure in gas mixtures of hydrogen and nitrogen only. In this paper, we report our most recent results in which we measured hydrogen partial pressures in gas mixtures that contain hydrogen, nitrogen, biphenyl, and diphenylether. Our results for this gas mixture were essentially the same as those obtained for the hydrogen/nitrogen mixture only, and they also had the same accuracy of +/-20%. This level of accuracy is sufficient to evaluate the performance of a hydrogen mitigation process because hydrogen partial pressure in the expansion tank decreases more than an order of magnitude when the mitigation process is operating. We examined the palladium/silver membrane after completing these measurements and did not observe any signs of membrane deterioration or contamination due to exposure to biphenyl and diphenylether at 405 degrees C. The membrane for these tests was 25 um thick. For the next sensor design that we are developing in 2018, we are using a membrane that is 127 um thick. This thickness is required for the membrane to withstand the 150 psi pressure drop across the membrane when exposed to actual headspace gas from the expansion tank. We performed initial tests in which we exposed a 127-um-thick palladium alloy membrane to 400 degrees C and 150 psi pressure drop and observed no signs of failure or gas leakage. Finally, we developed a transient model that accounts for hydrogen transport mechanisms within the sensor when measurements are made. Our model accounted for hydrogen diffusion through the boundary layer that is adjacent to the membrane and for hydrogen permeation across the membrane and into the permeate volume. Our modeling results agreed very closely with our experimental data when we assumed a boundary-layer thickness of 0.2 cm. This thickness is within the range of expected thicknesses for this gas composition, temperature, and pressure at minimum flowrate. Our model results showed that hydrogen diffusion through the boundary layer adjacent to the membrane is the rate-determining step for the transient pressure response when measuring hydrogen partial pressure.

14 SOLAR ENERGY↗

Finite Energy and Bounded Attacks on Control System Sensor Signals

Control system networks are increasingly being connected to enterprise level networks. These connections leave critical industrial controls systems vulnerable to cyber-attacks. Most of the effort in protecting these cyber-physical systems (CPS) has been in securing the networks using information security techniques and protection and reliability concerns at the control system level against random hardware and software failures. However, besides these failures the inability of information security techniques to protect against all intrusions means that the control system must be resilient to various signal attacks for which new analysis and detection methods need to be developed. In this paper, sensor signal attacks are analyzed for observer-based controlled systems. The threat surface for sensor signal attacks is subdivided into denial of service, finite energy, and bounded attacks. In particular, the error signals between states of attack free systems and systems subject to these attacks are quantified. Optimal sensor and actuator signal attacks for the finite and infinite horizon linear quadratic (LQ) control in terms of maximizing the corresponding cost functions are computed. The closed-loop system under optimal signal attacks are provided. Illustrative numerical examples are provided together with an application to a power network with distributed LQ controllers.

Cyber-physical↗

On Site Generation Of Low Level Odorous Standards For Validation Of FTICR-MS Gas Detector In Ambient Air

Gas sensors and analyzers can be externally calibrated with standard gases. These gas cylinders are usually difficult to obtain when it comes to low concentration standards, and their lifetime may be questionable. Starting from high concentration and diluting on site to desired lower concentrations allows to set up multi-point calibrations of the analytical device, such as an electronic nose. Volatile Organic Compounds (VOCs), including odorous chemicals, have been analyzed using Gas Chromatography (GC) often coupled with Mass Spectrometry (GC-MS), or specific olfactometric sensors. Proton Transfer Reaction (PTR) coupled with Fourier Transorm Ion Cyclotron Resonance (FTICR) MS is proposed to analyse low level of VOCs in air. FTICR MS is the most accurate and has the highest mass resolution of the MS techniques. B-Trap is a miniaturized FTICR instrument meant for real time VOCs analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors [Dissertation]

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal’s intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-GHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (μm-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor’s architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perót displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

Engineering(42)↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perot displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

42 ENGINEERING↗

Results from the CBC3 readout ASIC for CMS 2S-modules

The CBC3 is the latest version of the CMS Binary Chip for readout of the outer radial region of the upgraded CMS Tracker at the High Luminosity LHC. This 254-channel, 130 nm CMOS ASIC is designed to be bump-bonded to a substrate to which sensors will be wire-bonded. It will instrument double-layer 2S-modules, containing two overlaid silicon microstrip sensors, aligned with a parallel orientation. On-chip logic identifies Level-1 trigger primitives from high transverse-momentum tracks by selecting correlated clusters in the two sensors. The CBC3 was delivered in late 2016; wafer probing and performance tests have been carried out. Several prototype modules using the CBC3 have been produced and tested in the lab and in different beams. The results show that the CBC3 satisfies CMS requirements and only small corrections are needed for the final version of the chip for production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

Hot, cold, or just right? An infrared biometric sensor to improve occupant comfort and reduce overcooling in buildings via closed-loop control

To improve occupant comfort and save energy in buildings, we have developed a closed-loop air conditioning (AC) sensor-controller that predicts occupant thermal sensation from the thermographic measurement of skin temperature distribution, then uses this information to reduce overcooling (cooling-energy overuse that discomforts occupants) by regulating AC output. Taking measures to protect privacy, it combines thermal-infrared (TIR) and color (visible spectrum) cameras with machine vision to measure the skin-surface temperature profile. Since the human thermoregulation system uses skin blood flow to maintain thermoneutrality, the distribution of skin temperature can be used to predict warm, neutral, and cool thermal states. We conducted a series of human-subject thermal-sensation trials in cold-to-hot environments, measuring skin temperatures and recording thermal sensation votes. We then trained random-forest classification machine-learning models (classifiers) to estimate thermal sensation from skin temperatures or skin-temperature differences. The estimated thermal sensation was input to a proportional integral (PI) control algorithm for the AC, targeting a sensation level between neutral and warm. Our sensor-controller includes a sensor assembly, server software, and client software. The server software orients the cameras and transmits images to the client software, which in turn assesses occupant skin temperature distribution, estimates occupant thermal sensation, and controls AC operation. A demonstration conducted in a conference room in an office building near Houston, TX showed that our system reduced overcooling, decreasing AC load by 42% when the room was occupied while improving occupant comfort (fraction of “comfortable” votes) by 15 percentage points.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SPIDARman: System-Level Physics-Informed Detection of Anomalies in Reactor Collected Data Considering Human Errors

In nuclear power plants (NPPs), anomalies arising from sensors or human errors (HEs) can undermine the performance and reliability of plant operations. Anomaly detection models can be employed to detect sensor errors and HEs. Additionally, physics-informed machine learning models can utilize the known physics of the system, as described by mathematical equations, to ensure that sensor values are consistent with physical laws. Hence, we propose SPIDARman: System-level Physics-Informed Detection of Anomalies in Reactor Collected Data Considering Human Errors, a holistic physics-informed anomaly detection approach based on generative adversarial networks (GANs) to detect anomalies in both automatically collected sensor data and manually collected surveillance data. Here we test our approach on data collected from a flow loop testbed, showcasing its potential to detect anomalies. Results demonstrate that the proposed model performs better than the baseline GAN-based models in detecting sensor and surveillance anomalies, suggesting the potential of physics-informed anomaly detection GAN models in NPPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling active control of resistive wall mode with power saturation and sensor noise on HL-2M

The resistive wall mode (RWM) control on the HL-2M tokamak is simulated with the MARS-F code (Liu et al 2000 Phys. Plasmas 7 3681), aiming at quantifying control current and voltage requirements when more realistic issues are taken into account, i.e. the control power saturation and the sensor signal noise. The fluid model predicts a narrow stability region for the n = 1 RWM without magnetic feedback, in the 2D parameter space of the plasma pressure versus the toroidal flow speed. Magnetic feedback can fully stabilize the RWM on HL-2M. Without considering the voltage limitation and the sensor signal noise, it is found that plasma flow helps active control of the mode, by reducing the required critical feedback gain for both flux-to-current and flux-to-voltage control schemes. In the absence of the sensor signal noise, the lowest control voltage saturation level, below which the RWM control is lost, is found to roughly satisfy a linear relation to the plasma flow frequency, indicating that subsonic plasma flow is effective in relaxing the control power requirement for the RWM feedback stabilization. The presence of the sensor signal noise substantially modifies the feedback results. A statistical study finds that the sensor signal noise, with the standard deviation of 0.1 G on HL-2M, roughly doubles the required control voltage for successful mode control. The synergistic stabilization effect due to plasma flow is somewhat weakened by the presence of the sensor signal noise. At a given rotation, the tolerable voltage limit generally increases with increasing feedback gain due to the sensor signal noise.

Physics↗

Determining moisture content of Traditional Chinese Medicines using a near-infrared LED-based moisture content sensor with spectrum analysis

In Traditional Chinese Medicine (TCM), moisture content (MC) inspection using voltage level or a lock-in amplifier, with a features-based near-infrared light-emitting diode sensor is possible. Abundant absorption response in a wide frequency range and information in both the time-domain and frequency-domain can be obtained, with the square excitation method. However, planeness, heterogeneous particle sizes, and measurement noise negatively affect the time-domain feature during MC inspection. In this work, spectrum analysis (SA) for feature extraction is investigated, to precisely measure the MC of Dutong pills. The principal components for low and high frequencies, are aimed at counteracting the dimensional methods, which are used for supplying the lower dimensional features. The SA experimental results demonstrate that the low frequency components, ranging from the base to the 3rd harmonic components, have a high linear correlation with the MC. The calibration and validation experimental results reveal that the MC can be a monotonic function about the SA amplitudes or first principal component (PC1), with the proposed sensor. This method has the potential to be used for gauging automatic, in situ MCs, particularly for quality control and Process Analytical Technology in TCM. Future research opportunities include improving accuracy and application of the method under field conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Yakima River Basin Temporal Study: Sensor and Sample Data from Wenas Creek following the Evans Canyon Fire in Washington, USA

The Evans Canyon Fire occurred in Washington in August 2020 and burned 76,000 acres of the semi-arid shrub-steppe landscape at low to moderate severities. This fire burned across the Wenas Creek watershed, allowing for a sampling design that included a portion of the stream within the burned area and a reference site upstream of the burn. Monthly data was collected at an unburned (W10) and burned (W20) site from November 2020 to August 2022 for in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata. This dataset is comprised of one folder with field photos and one main data folder containing (1) sensor and sample field protocols; (2) file-level metadata (flmd); (3) data dictionary (dd); (4) international geo-sample number (IGSN) mapping file; (5) field metadata; (6) readme; (7) methods codes; (8) dissolved organic carbon (DOC; measured as non-purgeable organic carbon; NPOC); (9) total nitrogen (TN); (10) total suspended solids (TSS); (11) sensor data (specific conductance, pH, total dissolved solids, temperature, pressure, dissolved oxygen, and turbidity) averages; and (12) sensor installation methods. All files are .csv, .jpg, .jpeg, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Integrated titanium dioxide (TiO{sub 2}) nanoparticles on interdigitated device electrodes (IDEs) for pH analysis

Titanium dioxide (TiO{sub 2}) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of pH sensors using IDE nanocoated with TiO{sub 2} was studied in this paper. In this paper, a preliminary assessment of this intracellular sensor with electrical measurement under different pH levels. 3-aminopropyltriethoxysilane (APTES) was used to enhance the sensitivity of titanium dioxide layer as well as able to provide surface modification by undergoing protonation and deprotonation process. Different types of pH solution provide different resistivity and conductivity towards the surface. Base solution has the higher current compared to an acid solution. Amine and oxide functionalized TiO{sub 2} based IDE exhibit pH-dependent could be understood in terms of the change in surface charge during protonation and deprotonation. The simple fabrication process, high sensitivity, and fast response of the TiO{sub 2} based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO{sub 2} based IDE for sensitive, label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels (Final Scientific/Technical Report)

The project, "Advanced Facility Design and AI/ML Enabled Safeguards to Establish Secure, Economical Recycling of Fast Reactor Fuels," represents a significant advancement in nuclear fuel recycling technology. It integrates cutting-edge multimodal sensor fusion, machine learning (ML), and digital twin (DT) technologies to address challenges in material safeguarding, process optimization, and regulatory compliance for pyroprocessing facilities. This research has significantly enhanced the understanding of pyrochemical fuel recycling processes by developing innovative tools and methodologies. The Multimodal Safeguards Monitoring Unit (MSMU) combines electroanalytical techniques, Raman spectroscopy, and differential thermal analysis (DTA) to enable high-fidelity, near-real-time material accountancy measurements. Machine learning techniques, such as Long Short-Term Memory (LSTM) autoencoders, are utilized to detect anomalies in material balances and sensor data, improving the reliability of safeguards monitoring. Additionally, digital twin technology has been established to provide real-time system-level monitoring and diagnostics, integrating physics-based models with sensor data to optimize process safety and efficiency.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Experimental Evaluation of HVAC-Grade Carbon-Dioxide Sensors: Part 3, Humidity, Temperature, and Pressure Sensitivity Test Results

This is the third paper in a four-part series reporting on the test and evaluation of typical carbon-dioxide sensors used in building HVAC applications. Fifteen models of NDIR HVAC-grade CO2 sensors were tested and evaluated to determine the humidity, temperature, and pressure sensitivity of the sensors. This paper reports the performance of the sensors at various relative humidity, temperature, and pressure levels common to building HVAC applications and provides a comparison with manufacturer specifications. Among the 15 models tested, eight models have a single-lamp, single-wavelength configuration, four models have a dual-lamp, single-wavelength configuration, and three models have a single-lamp, dual-wavelength configuration. The sensors were tested in a chamber specifically fabricated for this research. A description of the apparatus and the method of test are described in Part 1 (Shrestha and Maxwell 2009). The test result showed a wide variation in humidity, temperature, and pressure sensitivity of CO2 sensors among manufacturers. In some cases, significant variations in sensor performance exist between sensors of the same model. Even the natural variation in relative humidity could significantly vary readings of some CO2 sensor readings. The effects of temperature and pressure variation on NDIR CO2 sensors are unavoidable without an algorithm to compensate for the changes. For the range of temperature and pressure variation in an air-conditioned space, the effect of pressure variation is more significant compared to the effect of temperature variation.

54 ENVIRONMENTAL SCIENCES↗

Performance Audit Report: Automated Meteorological Monitoring Stations, Lawrence Livermore National Laboratory

The Waste and Air Quality Offices Group at the Lawrence Livermore National Laboratory operates two main meteorological monitoring sites near Livermore, California. The primary met tower (Site 200) is located in the northwest corner of the lab and consists of a fifty-two (52) meter tower with vertical wind speed sensors, horizontal wind speed and direction sensors and air temperature sensors at fifty-two (52) meters, twenty-three (23) meters and ten (10) meters. In addition, there is a temperature and humidity probe at ten (10) meters. At two (2) meters there are upward and downward facing solar and infrared radiation sensors, an air temperature sensor, barometric pressure sensor and a temperature and relative humidity probe. At ground level there is a tipping bucket rain gauge located to the southwest of the tower. The datalogger, communication peripherals and the barometric pressure sensor are housed in a small building near the tower. The Site 300 met site is located approximately 10 miles east of Livermore within the boundary of the LLNL blast test site. This site also consists of a 52-meter tower which is configured the same as the 52-meter tower at Site 200. There is also a building at this site that houses the datalogger, communication peripherals and the barometric pressure sensor. At both Site 200 and Site 300, data are collected by Ethernet with telephone modem collection as a backup. The data collection interval for both sites is fifteen (15) minutes via workstations running Loggernet software located at the main lab facility. The audits of the Lawrence Livermore National Laboratory’s two automated meteorological stations located near Livermore, California were performed on October 24 & 25, 2023. These audits were performed under the guidelines of the Quality Assurance Handbook for Air Pollution Measurement Systems, Volume IV, Version 2 and the On-Site Meteorological Program Guidance for Regulatory Modeling Applications, U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Apparatus and method for measuring level

A vessel with a cavity for measuring level is disclosed. The vessel includes a differential pressure sensor having a first port and a second port, a reference tube that connects the first port of the differential pressure sensor to a bottom portion of the cavity, and an impulse tube that connects the second port of the differential pressure sensor to an impulse tube ending. At least a portion of the impulse tube extends through the cavity and ends at a fluid inlet. The fluid inlet is located at a level above the reference tube.

42 ENGINEERING↗