Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

ECAR-8823 Rev 0 Structural Evaluation of the MARVEL Support Frame in Dry Critical Configuration

The purpose of this ECAR is to structurally evaluate the MARVEL reactor support frame during the dry critical (DryCrit) start-up testing. The ECAR includes evaluation of the DryCrit configuration for tip-over of the frame during a seismic event, floor loading of the frame on the MFC-720 (TREAT) operating floor, stress analysis of the adapter ring, and stress analysis of the frame itself for gravity and seismic loads.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Prototyping, Fabrication and Test of the Mu2e AC-Dipole Magnet

Fermilab Magnet Systems is building three High-frequency AC-Dipole Magnets for the Mu2e experiment at Fermilab. These magnets are composed of three single-loop one-meter-long ferrite loaded segments. The excitation consists of a copper tube, which is also used as a means for its cooling with the inherited challenges of Voltage and Frequency uncoupling. These magnets are designed to operate either at 300 kHz or 4.4 MHz via resonance tuning. Following the completion of the design, prototyping, and analysis phases, all ferrites and other components were procured, and the magnets were fabricated to meet vacuum compatibility requirements using strict procedures. Each magnet undergoes thorough baking and testing before being installed in the experiment. This paper discusses the magnets' role in proton background suppression as it represents a unique and essential device for the Mu2e experiment at Fermilab. We present the magnet design choices, modeling approach, and the challenges encountered during fabrication. Additionally, we outline the power supply driving mechanism, the testing that was performed, and our results.

Elementi, Luciano [Fermilab] (ORCID:00000002766372↗

Resilient and Cost-Effective Hybrid Li-Ion Battery Energy Storage System for Sites with Solar Generation and Electric Vehicle (EV) Charging (CRADA Final Report, CRD-19-00799)

The batteries of an energy storage system designed for multiple use-cases are traditionally selected to withstand the highest rate at which a battery is discharged relative to its maximum capacity (C-rate) and cycling requirements of the most intense use-case. However, this is not cost-effective given that the price of the batteries is strongly correlated to C-rate and cyclability. We propose to establish design guidelines for a hybrid energy storage system and test an edge controller that uses high-power and high-energy batteries for high- cyclability use cases such as frequency regulation and electric vehicle (EV) charging and low-cost batteries for low-power and low-cyclability use cases such as summer peak loads. The three main objectives of this proposal are (i) establishing sizing guidelines for such a hybrid storage system, (ii) installing a hybrid storage system in the Energy Systems Integration Facility (ESIF) sized based on those guidelines, and (iii) testing an edge controller specific for the system through hardware tests.

14 SOLAR ENERGY↗

High-Temperature Active Magnetic Bearing Development for Supercritical CO 2 Machinery Applications

Hermetic machinery utilizing gas bearings for MW-scale supercritical CO 2 (sCO 2 ) machinery applications can have significantly lower power loss and enable improved cycle efficiency compared to conventional machinery with oil-lubricated bearings. Active magnetic bearings (AMBs) are another option anticipated to have similar power loss and load capacity to gas bearings as well as offering larger mechanical tolerances, the ability to tune properties, and high reliability due to lack of mechanical wear. AMBs also have proven commercial experience at MW-scale, though environments for high-temperature sCO 2 power cycle machinery conditions are novel. Besides the potential impact of AMBs for sCO 2 turbomachinery, the technology also offers promising benefits for steam and gas turbines for power generation, compressors and expanders for industrial heat and power, and in other oil and gas and space applications. The goals of this project were to conceptual design an AMB and perform material testing. Conceptual designs for radial and thrust AMBs were produced based on a hermetically-sealed sCO 2 machinery waste-heat recovery (WHR) application for sizing and loads, and choosing a target design temperature of 540°C useful for high-temperature sCO 2 turbines for concentrating solar power (CSP) applications. Conceptual designs were initially developed for multiple radial and thrust AMBs with spreadsheet-based calculations before selecting one of each to develop further using higher-fidelity design methods for magnetic and structural performance. It was found that the radial AMB at 540°C was feasible, but the thrust AMB needed to be limited to 315°C for high-speed operation. The decision for a reduced-temperature thrust AMB was the result of several significant conclusions: 1) Hiperco 50A, originally chosen for good magnetic performance at high temperature, had insufficient strength for high-speed operation, so it was replaced with 17-4 PH. 2) The reduced magnetic performance from 17-4 PH yielded a larger bearing size, reducing the strength margin. 3) This ultimately led to a creative design implementing a more-compact E-core topology, compared to the original (conventional) C-core, and an integral shaft-disk with Hirth joint connection. These conceptual designs are unique for the size and temperature in CO 2 , relevant for MW-scale CSP applications. Long term, high temperature test data was generated for several materials, filling a void in the current body of literature. Corrosion and magnetic performance measurements were produced for PM materials (Alnico 5-7C, Alnico 9C, and SmCo) with and without nickel-coating for environments of high-temperature CO 2 up to 550°C at atmospheric pressure and 450°C at 103 bar for up to 6,000 hours. Corrosion measurements were also produced for Hiperco 50, a SM material relevant for AMB laminations, with and without C5 coating. Comparisons were also made for 450°C and 550°C, atmospheric pressure air exposures up to 5,000 hours. Results generally show that coatings can be effective at improving oxidation resistance of the bare materials, and Alnicos generally outperformed SmCo after high-temperature exposure. In addition to technical feasibility demonstrated by the design, economic feasibility was demonstrated by updating the TEA from the reference machine, re-evaluating it with CAPEX and OPEX to reflect estimated changes from process-lubricated bearings to AMBs. AMBs were shown to be comparable in performance to process-lubricated bearings, still showing a notable improvement over conventional machinery architecture with oil-lubricated bearings.

42 ENGINEERING↗

Direct ink writing of shear exfoliated two-dimensional nanomaterial- elastomeric multifunctional nanocomposite

Direct ink writing (DIW) of polymer nanocomposites with high loadings of two-dimensional (2D) nanofillers (graphene and hexagonal boron nitride (hBN)) is challenging because of potential clogging, use of hazardous solvents, and agglomeration. Here, in this work, a shear exfoliation and sieving method to prepare DIW ink with high loading of nanofillers produced from low-cost bulk layered materials such as graphite and bulk hBN powder for successful DIW printing without the use of any solvents, binders, or plasticizers. The single-step exfoliation technique resulted in a composite with substantial layer reduction along the c-axis, as confirmed by SEM, TEM, XRD, and Raman analysis. Incorporating exfoliated graphene (40 wt%) increased viscosity by ∼6 orders of magnitude due to enhanced particle–matrix interactions, leading to pronounced yield stress behavior and a yield stress of approximately 1598 Pa, which enabled excellent shape retention during extrusion. Using the DIW technique, porous structures such as desalination membranes, self-sensing bone scaffolds, thermal management coating, and serpentine strain sensors were fabricated. When tested in a direct contact membrane distillation setup, the fabricated membrane demonstrated a promising permeate flux of 21.85 Lm −2 h −1 and a salt rejection of 74.3 %. The fabricated serpentine sensor exhibited stable signal variations under cyclic tensile loading, with a working range of 0–200 % strain and a maximum gauge factor of 43,735. A cell culture test using the printed bone scaffold demonstrated promising cell attachment and proliferation. The DIW printed hBN nanocomposite exhibited reversible shape change under heat, demonstrating potential 4D printing capability and efficient thermal management when exposed to high heat or flame.

Desalination↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

STRUCTURAL MODELING TO SUPPORT POST-YIELD ACCEPTANCE CRITERIA FOR SPENT NUCLEAR FUEL CLADDING

Spent nuclear fuel (SNF) is evaluated for structural failure during storage and transportation scenarios. The U.S. Department of Energy’s Spent Fuel and Waste Science and Technology (SFWST) program has sponsored significant research in quantifying mechanical loads on SNF during storage and transportation scenarios using experimental and modeling methods. The SFWST program has also performed significant research on measuring the mechanical behavior of irradiated SNF as defueled cladding segments and cladding with fuel pellets to measure composite behavior. This paper considers some of the key material data from the Sibling Pin testing and uses structural modeling and analysis methods that have been informed by testing to consider post-yield acceptance criteria for SNF cladding structural analysis. Test data published by Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL) are the foundation for informing the material behavior of the models developed in this study. In particular, four-point bend (4PB) tests of fueled and defueled cladding segments provide significant information about the bending failure mode of SNF. ORNL’s 4PB test data is on fueled cladding segments, so the composite behavior of SNF is demonstrated. This paper describes PNNL’s coincident beam model that was developed to approximate the composite behavior of SNF. This paper also presents PNNL’s structural dynamic finite element models of a cask tip-over scenario, which is predicted to cause the strongest mechanical loads on SNF of all postulated storage and transportation scenarios. SNF bending loads predicted in the cask tip-over scenario and cladding acceptance criteria beyond yield are considered, with justification based on the Sibling Pin test data. ASME Boiler and Pressure Vessel code stress intensity limits are also considered. The ultimate goal of this work is to aid in the justification of structural acceptance criteria for SNF cladding beyond the cladding’s irradiated yield strength for use in structural analysis of all storage and transportation scenarios.

Klymyshyn, Nicholas A.↗

Predictive model using artificial neural network to design phase change material-based ocean thermal energy harvesting systems for powering uncrewed underwater vehicles

Uncrewed Underwater Vehicles (UUVs) are a major beneficiary of the phase change material (PCM)-based ocean thermal energy harvesting technology for their mission needs. However, this technology relies on different parameters and energy conversion steps that could be critical to the general energy generation efficiency. Sea trials showed that the design performed lower than their laboratory design specifications. This underperformance results from different factors, mainly the UUV’s trajectory, travel time, underwater ocean currents, temperature fluctuations, and biofouling on the heat exchanger due to long term underwater operations. Therefore, there exists a need to continuously monitor the ambient energy harvesting system and predict system performance, for mission planning purposes. Two major parameters influencing the energy harvesting system include the final pressure inside the hydraulic energy storage vessel or accumulator, and the electrical load value. Here, this work focuses on the hydraulic to electric energy conversion system. Therefore, a combination of numerical model and experimental testing is used to develop a predictive model using artificial neural network using MATLAB. After validation with experimental testing, 1000 data samples obtained from the numerical model are used to train the ANN. Compared to the experimental results, the developed ANN model can predict in less than a second the designed benchtop system’s total efficiency with less than 15 percent maximum error range. This predictive model development represents a cost-effective way for optimization and a computational energy efficient mode aboard UUVs for mission planning for deployed UUVs using PCM-based ocean thermal energy harvesting technology.

30 DIRECT ENERGY CONVERSION↗

Deformation and Delamination of Dynamically Bulging Bilayered Films

We employ finite element simulations to study the dynamic bulging of films under shock tube conditions and compare these responses with quasi-static bulging. Both scenarios subject the film to time-varying pressure. Two film types are considered: uniform material films and bilayers with a relatively soft interior layer and a hard exterior layer. The interface between the materials in the bilayer cases is modeled as a cohesive zone that follows a bilinear normal traction-separation cohesive law. Additionally, bilayer films with preexisting cracks in the interior layer are analyzed. Parametric studies are also conducted to explore the effects of loading rate and specimen size. The mechanical response of all materials is assumed to be strain-rate independent, focusing solely on the inertial effects in the response of the films under dynamic loading, and the absence of such effects under quasi-static loading. The results indicate that quasi-static bulging exhibits a predictable plate bending like deformation. In contrast, depending on the loading rate and specimen size, dynamic bulging can give rise to elastic waves, and a sequence of deformation processes including initial uniform acceleration, followed by bending-like deformation, and finally through-thickness biaxial stretching. Dynamic loading also leads to larger bulge formation and greater deformation than quasi-static loading. A key finding is the role of preexisting cracks in driving delamination under dynamic loading, which is absent in quasi-static loading. This work enhances our understanding of dynamic bulging and motivates further research on characterizing delamination in layered films using dynamic bulge tests.

36 MATERIALS SCIENCE↗

Strong Coupling of Iridium and Boron–Carbon-Nitride Support for Enhanced Acidic Water Oxidation

Supporting iridium (Ir)-based materials on stable and suitable substrates is an efficient strategy to improve their catalytic performance for the oxygen evolution reaction (OER) in harsh acidic environments. Herein, we report a series of Ir catalysts supported on boron–carbon-nitride (BCN), denoted as Ir/BCN. Detailed experiments combined with density functional theory calculations demonstrate strong interactions between Ir nanoparticles (NPs) and the BCN support, significantly contributing to the improved OER performance. Among the synthesized catalysts, the Ir/BCN-75 catalyst outperforms commercial Ir black and IrO 2 in both half-cell and proton exchange membrane water electrolysis (PEMWE) tests. Specially, the Ir/BCN-75 catalyst achieves a high current density of 2.94 A cm –2 at 1.9 V with a low Ir loading of 0.26 mg cm –2 in PEMWE measurements, exceeding most Ir-based catalysts reported to date. The BCN support interacts strongly with Ir, wherein Ir–N bonding directs the Ir NP growth and enhances electrocatalytic activity, while Ir–B bonding contributes to the stability of the Ir/BCN catalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of the form of chromium on HLW vitrification

The primary objective of the work described herein was to determine the effect of two forms of chromium reported to be abundant in the waste (Cr(OH) 3 and chromite) on spinel formation in the glass, feed properties, and feed processing characteristics during the vitrification process. A secondary objective of the work was to evaluate oxidants that influence the redox state of chromium in the glass, which has the potential to reduce spinel crystallization thereby allowing potential increases in waste loadings in HLW glasses with high chromium content. This was accomplished through a combination of crucible-scale and DM100 melter system tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Integration and performance of large area picosecond photodetectors in the accelerator neutrino neutron interaction experiment

ANNIE, the Accelerator Neutrino Neutron Interaction Experiment, is a 26-ton Gadolinium-loaded water Cherenkov detector located at the Booster Neutrino beam line at Fermilab to mainly measure neutron multiplicity of neutrino interactions and test the performance of Large Area Picosecond Photodetectors (LAPPD). This thesis presents the integration of LAPPD at ANNIE and the preliminary performance analysis. LAPPDs achieved 2.48ns bunch structure resolution, even considering the time of flight and the intrinsic bunch width. The analysis also achieves better than 100ps intrinsic timing resolution, sub-mm position resolution for a single photoelectron, and cm-level resolution in conditional muon track reconstruction.

Feng, Yue [Iowa State U.] (ORCID:0000000332021351)↗

A Distributionally Robust Optimization Framework for Stochastic Assessment of Power System Flexibility in Economic Dispatch

Given the complexity of power systems, particularly the high-dimensional variability of net loads, accurately depicting the entire operational range of net loads poses a challenge. To address this, recent methodologies have sought to gauge the maximum range of net load uncertainty across all buses. In this paper, we consider the stochastic nature of the net load and introduce a distributionally robust optimization framework that assesses system flexibility stochastically, accommodating a minimal extent of system violations. We verify the proposed method by solving the flexibility of the economic dispatch problem on four distinct IEEE standard test systems. Compared to traditional deterministic flexibility evaluations, our approach consistently yields less conservative flexibility outcomes.

distributionally robust optimization↗

Evaluation of Technologies to Mitigate the Presence of Gaseous Elemental Mercury in Waste Disposal Containers

A study was conducted to evaluate sorbent technologies that can mitigate the presence of elemental mercury (Hg⁰) in waste containers for mercury-contaminated debris (MCD). Decontamination and demolition (D&D) activities at the Y-12 National Security Complex (Y-12) and other U.S. Department of Energy (DOE) Oak Ridge Reservation (ORR) facilities generate MCD requiring offsite disposal. The debris is packaged in appropriate waste containers and may be temporarily stored onsite prior to transport for treatment and/or disposal. During transportation of loads that had no visible liquid Hg at the point of origin, temperature changes can cause Hg⁰ to evaporate, condense, and form droplets on container walls. Furthermore, vibration during transportation could cause beads of Hg to be released from the debris, container walls, and ceiling, resulting in pools of liquid Hg⁰ on the container floor. Waste acceptance criteria (WAC) limitations for commercial disposal facilities, the Nevada National Security Site (NNSS), and ORR mixed low-level waste landfills prohibit the presence of any free liquids in containers identified as a solid waste form. Potential solutions to mitigate the presence of residual liquids that could be formed through vapor condensation include the use of sorbents or similar materials to capture and stabilize volatile Hg⁰ vapors and thus ensure compliance with landfill WAC requirements. This report summarizes data from small-scale laboratory experiments conducted to evaluate sorbent materials for Hg⁰ vapor suppression and sorption of liquid Hg⁰ that could form under relevant transportation and disposal conditions. A series of experiments was conducted to evaluate commercial sorbent materials and their effectiveness for Hg⁰ sorption across a temperature range from 19.4°C to 60°C. The impact of residual moisture on sorption was investigated under relevant conditions, and leaching tests were performed to assess the stability of Hg⁰ captured sorbent materials. The results provide estimates for sorbent quantities needed for a given Hg⁰ mass loading based on experimental results exposing sorbents to gaseous and liquid Hg⁰ at various mass ratios. Overall, sorbents that were most effective for Hg⁰ vapor suppression were brominated activated carbons, mackinawite-based sorbents coated on vermiculite, and sulfur-modified granular activated carbon. Elevated temperatures and moisture conditions did not result in significant increases of Hg⁰ headspace concentrations, and the materials also demonstrated high sorption capacities for the sorption of liquid Hg⁰.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗