Search NASA⌕ Search

SEARCH · Search NASA

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Corrosion and Mechanical Durability Testing in High Temperature Molten Sulfur (CRADA Final Report)

The overall goal of the project is to explore and identify suitable candidate materials for high-temperature molten sulfur thermal energy storage (TES) operating up to a maximum temperature of 400°C–420°C for industrial process heat applications. A detailed corrosion and strength analysis of coupons subjected to long-term thermal testing in molten sulfur will be conducted to characterize the fundamental corrosion mechanism, corrosion rates, and mechanical durability. The results from the project contribute to the engineering design of sulfur TES systems with desired longevity and lower construction and maintenance costs. The research outcome benefits the TES research and development community by providing detailed corrosion and degradation information for more effective engineering design of the molten sulfur TES containment. It improves the diversity and reliability of the renewable technologies available for the U.S. industries and U.S. power grid.

14 SOLAR ENERGY↗

Long-life high performance fuel cell program

A multihundred kilowatt Regenerative Fuel Cell for use in a space station is envisioned. Three 0.508 sq ft (471.9 cm) active area multicell stacks were assembled and endurance tested. The long term performance stability of the platinum on carbon catalyst configuration suitability of the lightweight graphite electrolyte reservoir plate, the stability of the free standing butyl bonded potassium titanate matrix structure, and the long life potential of a hybrid polysulfone cell edge frame construction were demonstrated. A 18,000 hour demonstration test of multicell stack to a continuous cyclical load profile was conducted. A total of 12,000 cycles was completed, confirming the ability of the alkaline fuel cell to operate to a load profile simulating Regenerative Fuel Cell operation. An orbiter production hydrogen recirculation pump employed in support of the cyclical load profile test completed 13,000 hours of maintenance free operation. Laboratory endurance tests demonstrated the suitability of the butyl bonded potassium matrix, perforated nickel foil electrode substrates, and carbon ribbed substrate anode for use in the alkaline fuel cell. Corrosion testing of materials at 250 F (121.1 C) in 42% wgt. potassium identified ceria, zirconia, strontium titanate, strontium zirconate and lithium cobaltate as candidate matrix materials.

Martin, R. E.↗

Use of the Aromascan(TM) Instrument for Nonsubjective Evaluation of Rodent Spaceflight Hardware

This report describes the verification and utilization of the AromaScan(TM) (Hollis, NH) instrument for the ground-based evaluation of odor containment by various spaceflight habitats developed at NASA's Ames Research Center (ARC). The AromaScan(TM) instrument is an electronic odor detection system consisting of 32 polymer sensors that respond differentially to 10 different chemical groups present in an air sample. The AromaScan(TM) system also includes neural network software for constructing a database of known odors, against which an unknown odor can be compared. At present, the standard method for characterizing rodent odor containment during the development and testing of spaceflight hardware is the use of a human odor assessment panel. However, this can be a very time consuming and costly process, and the results are inherently subjective. The AromaScan(TM) system should produce more consistent and objective results, as well as a cost savings in the long term. To test and verify the AromaScan(TM) instrument, daily air samples will be collected from the exhaust port of rodent habitats, during experiment development tests, then injected into the instrument and used to create a database of recognizable odors. Human sniff tests will be performed in conjunction with the AromaScan(TM) analysis, and the results will be correlated. We will then teach the neural network to differentiate between an acceptable and an unacceptable odor profile, as defined by the human sniff test, and to be able to accurately identify an odor that would not pass a sniff panel. The results of our efforts will be to verify that the AromaScan(TM) system is a valuable alternative to human sniff panel assessments for the early iterative process of designing and testing rodent waste filters for spaceflight. Acceptance by a human panel will remain one of the final criteria for successful rodent habitat development.

Scribner, K. A.↗

Development of space stable thermal control coatings for use on large space vehicles

The evaluation and environmental testing of zinc orthotitanate pigments for use as space stable thermal control coatings on large space vehicles are discussed. Electron paramagnetic resonance spectra of the pigments and their precursor compounds are examined. A continuing study of the spectral intensity of mercury-argon and mercury-xenon sources in reported. Results of long term environmental testing of commercially available, strippable, protective coatings are discussed.

Gilligan, J. E.↗

Sodium Exposure Tests of A709 Steel (FY2020 Progress Report)

Sodium exposure tests were conducted on the first commercial heat, H58776 of A709 steel. Six different processing and heat treatment conditions were investigated, including three processing conditions, namely, Argon-Oxygen-Decarburization (AOD), Electro-slag Remelting (ESR), and Electro-slag Remelting with subsequent homogenization (HOMO), and two heat treatment conditions, i.e. solution annealing at 1100°C (SA1100°C) or 1150°C (SA1150°C). Specimens of AOD-SA1100°C, AOD-SA1150°C, ESR-SA1100°C, ESR-SA1150°C, HOMO-SA1100°C, and HOMO-SA1150°C were tested in sodium at 650°C and for times up to 10,152 h. Specimens in the AOD-SA1100°C and AOD-SA1150°C conditions were also tested in sodium at 550 and 600°C. Parallel thermal aging experiments were carried out for comparison with sodium exposure tests to separate the thermal and sodium effects. It was found that A709 H58776 generally showed a weight loss after sodium exposures at 650°C except a few data points of the ESR-SA1100°C specimens. The corrosion rate showed large variations in the initial stage and decreased with increasing exposure time. Long-term exposure tests are needed to determine its steady-state corrosion rate. The AOD-SA1100°C and HOMO-SA1100°C specimens showed similar tensile responses after thermal or sodium exposures at 650°C. The yield stress increased, the ultimate tensile strength decreased, and the uniform and total elongations were reduced after thermal or sodium exposures. A longer exposure time had a minimal effect on the tensile strength but further reduced the tensile ductility. The sodium-exposed specimens had higher tensile strength than the thermally-aged specimens. In contrast, the ESR-SA1100°C specimens showed an increase in the yield stress and the ultimate tensile strength after thermal or sodium exposures at 650°C and ~10,000 h. The AOD-SA1150°C and ESR-SA1150°C specimens showed similar tensile behavior after thermal or sodium exposures at 650°C.Thermal or sodium exposures at 650°C increased the yield stress, decreased the ultimate tensile strength, and reduced uniform and total elongations. There were minimal differences in tensile properties between the sodium-exposed and thermally-aged specimens after an ~3000 h exposure. After an exposure for ~10,000 h the sodium-exposed specimens showed higher yield stress and ultimate tensile strength and lower uniform and total elongations than the thermally-aged specimens. For the HOMO-SA1150°C specimens, thermal or sodium exposures at 650°C significantly increased the yield stress but had a minimal effect on the ultimate tensile strength. Both uniform and total elongations were significantly reduced at an exposure time of ~3,000 h, and they were further reduced after an exposure of ~10,000 h. The sodium-exposed specimens had lower tensile ductility than the thermally-aged specimens. Before exposure, the stress-strain curves of the specimens in all six processing-heat treatment conditions showed serrations indicating the dynamic aging effect at 650°C. Thermal aging or sodium exposures at 650°C after ~10,000 h completely removed the serrations of the flow curves in A709 H58776, indicating strong precipitation during thermal or sodium exposures. Longer-term sodium exposure tests are needed to determine the steady-state corrosion rates in sodium for A709 H58776 and fully understand the influence of sodium exposures on its mechanical performance.

36 MATERIALS SCIENCE↗

Assessing the Oxidative Stability of Anion Exchange Membranes in Oxygen Saturated Aqueous Alkaline Solutions

While anion exchange membrane water electrolyzers show promise as a source of green hydrogen using low-temperatures and non-platinum group metal catalysts, many concerns must be addressed. A primary challenge for the development of high-performance anion exchange membrane water electrolyzers is the fabrication of a stable membrane that will be able to survive long-term stability test while maintaining high anion conductivity, which is a necessity for a durable water electrolyzer. This method will present a standardized protocol that can be used by researchers to assess the quality of their AEM materials and be able to provide insight into how materials may be degrading and how to improve the quality of AEMs. Using Mohr or Volhard titration to measure ion-exchange capacity, EIS to determine the ionic conductivity, NMR and FTIR to understand the extent of membrane degradation over time, and mechanical analyzers to determine the strength of their AEMs, this standardized protocol will guide researchers to determining and improving upon the long-term durability and performance of their AEM materials.

36 MATERIALS SCIENCE↗

Degradation of Leakage Currents and Reliability Prediction for Tantalum Capacitors

Two types of failures in solid tantalum capacitors, catastrophic and parametric, and their mechanisms are described. Analysis of voltage and temperature reliability acceleration factors reported in literature shows a wide spread of results and requires more investigation. In this work, leakage currents in two types of chip tantalum capacitors were monitored during highly accelerated life testing (HALT) at different temperatures and voltages. Distributions of degradation rates were approximated using a general log-linear Weibull model and yielded voltage acceleration constants B = 9.8 +/- 0.5 and 5.5. The activation energies were Ea = 1.65 eV and 1.42 eV. The model allows for conservative estimations of times to failure and was validated by long-term life test data. Parametric degradation and failures are reversible and can be annealed at high temperatures. The process is attributed to migration of charged oxygen vacancies that reduce the barrier height at the MnO2/Ta2O5 interface and increase injection of electrons from the MnO2 cathode. Analysis showed that the activation energy of the vacancies' migration is ~ 1.1 eV.

acceleration factors↗

Reliability Quantification of the Flexure: A Critical Stirling Convertor Component

Uncertainties in the manufacturing, fabrication process, material behavior, loads, and boundary conditions results in the variation of the stresses and strains induced in the flexures and its fatigue life. Past experience and the test data at material coupon levels revealed a significant amount of scatter of the fatigue life. Owing to these facts, the design of the flexure, using conventional approaches based on safety factor or traditional reliability based on similar equipment considerations does not provide a direct measure of reliability. Additionally, it may not be feasible to run actual long term fatigue tests due to cost and time constraints. Therefore it is difficult to ascertain material fatigue strength limit. The objective of the paper is to present a methodology and quantified results of numerical simulation for the reliability of flexures used in the Stirling convertor for their structural performance. The proposed approach is based on application of finite element analysis method in combination with the random fatigue limit model, which includes uncertainties in material fatigue life. Additionally, sensitivity of fatigue life reliability to the design variables is quantified and its use to develop guidelines to improve design, manufacturing, quality control and inspection design process is described.

Shah, Ashwin R.↗

Evaluation of amine-incorporated porous polymer networks (aPPNs) as sorbents for post­combustion CO 2 capture

This is the final report for the TAMU project “Evaluation of amine-incorporated porous polymer networks (aPPNs) as sorbents for post­combustion CO 2 capture.” During this project, a team consisting of the Zhou group at Texas A&M University and framergy Inc. were tasked with developing a porous polymer network (PPN) based sorbent system for CO 2 capture applications. The three year project was divided up into 3 individual budget periods. During budget period 1 the team develop multiple novel PPN based sorbents and began initial CO 2 capture experiments. During the course of this research the team determined that two sorbents were the standout targets, PPN-150-DETA and PPN-151-DETA. During budget period 2 the team further developed these two materials, gathering data to determine their performance under both wet and dry conditions, determine their CO 2 adsorption capacities, heats of adsorption, regenerative energy demands, and mechanical attrition. In addition, budget period 2 saw the development of 50 g and 250 g batches of both sorbents, while still maintaining >0.10 g/g uptake capacity under wet gas conditions. Following budget period 2 testing, the team opted to continue on with PPN-151-DETA due to its superior CO 2 cycling capabilities, with a consistent uptake capacity observed over 30 cycles at the lab scale. During budget period 3 the team further developed the material at scale, producing a 1 kg batch of material. Following this, the team performed multiple long-term cycling tests in the presence and absence of SO 2 using a 100 mL column. During this testing the team observed that the material loses significant uptake capacity due to SO 2 , as well as shows some level of DETA loss, which resulted in instrument breakdown and a request for a no-cost extension. The team was able to finalize the experiment with a test using a 1.5 L column in the absence of SO 2 , with the final cycle uptakes being around 0.035 g/g due to the need to harshly activate the material to prevent DETA desorption.

20 FOSSIL-FUELED POWER PLANTS↗

Development of a Thermal Spray, Redox Stable, Ceramic Anode for Metal Supported SOFC

In this program, GE global research and GE fuel cells in Malta conducted thermal spray optimization experiments, initially focusing on a well-established ceramic anode formulation, lanthanum strontium titanate combined with gadolinium doped ceria. Powder engineering work was conducted both internally and with vendors to develop repeatable, stable, and flowable thermal spray feedstocks. Agglomerate sintering was conducted in the last phase of the project, building on earlier program work, and was used to increase run stability during the longer scaled up runs for the 410 cm 2 cells. Further powder engineering would be needed to fully design a powder ready for full scale manufacturing. During preliminary work on the LST-GDC electrodes, GE demonstrated 100 cm 2 stacks enduring multiple redox cycles with limited impact. Another key finding on the project was the identification of process conditions for two component ceramic anode thermal spray without the formation of phase impurities which were present in all early work on the program. GE global research and West Virginia University screened a large number of ceramic anode formulations, focused on identifying materials with ideal materials properties for use in SOFC anodes. In addition, synthetic scaling research was conducted to increase powder synthesis batch size several orders of magnitude during the course of project work. West Virginia University was able to show button cells using two component ceramic anodes which produced > 890 mW/cm 2 and even a single component SOFC button demonstrating > 1 W/cm 2 performance. These button cell tests show the great potential of these redox stable materials. Down-selected ceramic anode formulations were combined with the optimized thermal spray process methods to first demonstrate multiple groups of 100 cm 2 SOFC stacks able to achieve the power density goals for the project. GE research also quickly investigated the performance of a subset of these formulations on long term degradation tests and assessed their performance on simulated natural gas reformate. In the final phase of the program, scaling activities were employed to translate from the 100cm2 process up to 410 cm 2 . Two large format 10-cell stack tests were completed, and one of these stacks produced 0.987 kW which is one of the highest power demonstrations of ceramic anode, metal support, SOFC technology known to GE. These ceramic anode stacks had been produced with all other materials in the stack held constant, demonstrating the flexibility of the thermal spray process in scaling to very large electrode size.

30 DIRECT ENERGY CONVERSION↗

Facility and Methods Developed for Simulated Space Vacuum Ultraviolet Exposure Testing of Polymer Films

Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the Sun in the space environment can degrade polymer films, producing changes in their optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultralightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. The NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of combined or sequential simulated space environmental exposures to determine combined damaging effects with other aspects of the space environment, which include solar ultraviolet radiation, solar flare x-rays, electron and proton radiation, atomic oxygen (for low-Earth-orbit missions), and temperature effects. Because the wavelength sensitivity of VUV damage is not well known for most materials, Glenn's VUV facility uses a broad-spectrum deuterium lamp with a magnesium fluoride window that provides output between 115 and 200 nm. Deuterium lamps of this type were characterized by the National Institute of Standards and Technology and through measurements at Glenn. Spectral irradiance measurements show that from approximately 115 to 160 nm, deuterium lamp irradiance can be many times that of air mass zero solar irradiance, and as wavelength increases above approximately 160 nm, deuterium lamp irradiance decreases in comparison to the Sun. The facility is a cryopumped vacuum chamber that achieves a system pressure of approximately 5310(exp -6) torr. It contains four individual VUV-exposure compartments in vacuum, separated by water-cooled copper walls to minimize VUV radiation and any sample contamination cross interactions between compartments. Each VUV-exposure compartment contains a VUV deuterium lamp, a motor-controlled sample stage coupled with a moveable cesium iodide VUV phototube, and two thermocouples for temperature measurement. The vacuum chamber and exterior equipment is shown. Each VUV lamp is located at the top of the chamber with its projection-tube pushed through an O-ring compression fitting. The lamp assemblies are located on ports that can be isolated from the rest of the vacuum chamber, permitting maintenance or replacement of the lamps without breaking vacuum in the main chamber where the samples are located. A view of two of the four interior VUV-exposure compartments, including the moveable sample stages and detector holders is also shown. Glenn is using this facility to support testing of Next Generation Space Telescope sunshield materials that is being led by the NASA Goddard Space Flight Center and to develop an understanding of the wavelength, intensity, and temperature dependence of VUV-induced polymer degradation.

Dever, Joyce A.↗

Simulated Space Vacuum Ultraviolet (VUV) Exposure Testing for Polymer Films

Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the sun in the space environment can cause degradation to polymer films producing changes in optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultra-lightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of sequential simulated space environmental exposures to determine combined damaging effects. This paper will describe the effects of VUV on polymer films and the necessity for ground testing. Testing practices used at Glenn Research Center for VUV exposure testing will be described including characterization of the VUV radiation source used, calibration procedures traceable to the National Institute of Standards and Technology (NIST), and testing techniques for VUV exposure of polymer surfaces.

Dever, Joyce A.↗

Large area vertical Ga 2 O 3 Schottky diodes for X-ray detection

In this work, the Schottky barrier diodes were fabricated from a bulk Sn-doped (001) n-type Ga 2 O 3 substrate with a Si-doped epitaxial layer grown by hydride vapor phase epitaxy (HVPE), which demonstrate a good response to X-rays. Circular metal contacts with diameters ranging from 50 to 1500 um and square metal contacts ranging from 100 X 100 to 1600 X 1600 um 2 were deposited on the wafer. The devices were characterized for their electrical performance including forward current–voltage (FIV), reverse current–voltage (RIV), and capacitance-voltage (CV) measurements. The best device showed a breakdown voltage of –804 V and the devices tested had an average ideality of 1.12. The devices exhibited a clear response to X-rays even at zero bias with an experimentally observed response time 1.03 s and a linear response of detector signal to the X-ray dose rate. The experimentally observed device response time improved to 0.25 s when bias voltage is applied. The device also survived a long-term stability test of over 2 h under a constant X-ray irradiation. The sensitivity and the lower limit of detection for X-ray by Ga2O3 epitaxial Schottky detectors were discussed and determined as 43.5 C/mGy cm –2 at –200 V and 8.31 nGy Air /s, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prediction of Creep-Induced Strain Using a Symbolic Regression-Based Model

Material creep under high-temperature conditions limits the lifetime and safety of structural systems such as advanced nuclear reactors. Conventional creep testing is slow and often produces inconsistent results across nominally identical experiments, making lifetime prediction uncertain. Here, to address these challenges, this work develops a data-driven symbolic regression (SR) model that consolidates results from duplicate creep tests and predicts the remaining strain-time curve of an ongoing experiment. The method uses piece-wise multi-objective SR with physical constraints to generate analytic, interpretable functions describing transient creep strain. Applied to Inconel Alloy 617 data, the approach achieved relative mean absolute errors of 1.0–9.5%, providing closed-form predictions of strain evolution. These results demonstrate a first step toward reducing the duration and cost of long-term creep testing while retaining physically interpretable model forms.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

OECD MCCI project long-term 2-D molten core concrete interaction test design report, Rev. 0. September 30, 2002.

The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. As a follow-on program to MACE, The Melt Coolability and Concrete Interaction Experiments (MCCI) project is conducting reactor material experiments and associated analysis to achieve the following two technical objectives: (1) resolve the ex-vessel debris coolability issue through a program that focuses on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term two-dimensional molten core-concrete interactions under both wet and dry cavity conditions. Achievement of these two objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs for future plants. In terms of the first program objective, the Small-Scale Water Ingression and Crust Strength (SSWICS) test series has been initiated to provide fundamental information on the ability of water to ingress into cracks and fissures that form in the debris during quench, thereby augmenting the otherwise conduction-limited heat transfer process. A test plan for Melt Eruption Separate Effects Tests (MESET) has also been developed to provide information on the extent of crust growth and melt eruptions as a function of gas sparging rate under well-controlled experiment conditions. In terms of the second program objective, the project Management Board (MB) has approved startup activities required to carry out experiments to address remaining uncertainties related to long-term two-dimensional molten core-concrete interaction. In particular, for both wet and dry cavity conditions, there is uncertainty insofar as evaluating the lateral vs. axial power split during a core-concrete interaction due to a lack of experiment data. As a result, there are differences in the 2-D cavity erosion predicted by codes such as MELCOR, WECHSL, and COSACO. The first step towards generating this data is to produce a test plan for review by the Project Review Group (PRG). The purpose of this document is to provide this plan.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of an Embedded Fracture and Borehole Modeling Approach to the Understanding of EGS Collab Experiment 1

EGS Collab is a series of meso-scale experiments and associated numerical simulation activities being funded by the United States Department of Energy, Geothermal Technologies Office (GTO) to investigate enhanced geothermal system processes under in-situ stress and slightly elevated temperature conditions. This project is designed to provide scientists and engineers with immediate access to impermeable rock at scales larger than possible in the laboratory, but generally smaller than those for commercial production. Immediate access to rock is provided via the existing drifts of the former Homestake Gold Mine, now operated as the Sanford Underground Research Facility in Lead, South Dakota. The objectives of the EGS Collab project are to develop well controlled fracture networks between injector and producer boreholes using normal and shear stimulation for permeability enhancement. The first experimental site was located off the West Access drift on the 4850 Level (4850 feet below ground surface) in phyllite of the Precambrian Poorman formation, and involved the creation of a fracture network comprising a combination of hydraulic and natural fractures. A second experimental site is now being considered near the battery alcove on the 4100 Level in amphibolite and rhyolite of the Yates Unit. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO’s flagship EGS research effort. Experiment 1 has comprised a series of successful tests, including a long-term chilled-water circulation test, but the testbed has two atypical EGS elements. Active ventilation in the adjacent drift over a 50-year period cooled the testbed rock mass and hydraulic fracturing intersected monitoring boreholes making them conduits for fluid flow. Numerical simulations executed in support of the design of the EGS Collab Experiment 1, computed a radial temperature distribution and stress gradient orthogonal to the drift axis, resulting in the forecast of an oblong hydraulic fracture geometry, extended in the direction of the drift from the stimulation borehole. This paper describes the numerical simulation of long-term chilled-water circulation test with an embedded fracture and borehole modeling approach. The principal objective of the simulation work is show agreement between experimental observations in terms of production fluid temperatures, monitoring borehole temperatures, injection and production pressures, and tracer recoveries using a single conceptual model for the fracture network, using characterization and monitoring data generally available for EGS. A secondary objective is to improve the numerical simulation result comparisons with additional data available from the broader monitoring equipment within the testbed versus deeper, hotter, and more remote EGS. One complicating factor for comparisons between the numerical simulation results and experimental observations, is the Joule-Thomson heating associated with large pressure drops across the fracture network.

numerical simulation, embedded fractures and boreh↗

Fabrication of Pd/Pd-Alloy Films by Surfactant Induced Electroless Plating for Hydrogen Separation from Advanced Coal Gasification Processes

Dense Pd, Pd-Cu and Pd-Ag composite membranes on microporous stainless steel substrate (MPSS) were fabricated by a novel electroless plating (EP) process. In the conventional Pd-EP process, the oxidation-reduction reactions between Pd-complex and hydrazine result in an evolution of NH 3 and N 2 gas bubbles. When adhered to the substrate surface and in the pores, these gas bubbles hinder uniform Pd-film deposition which results in dendrite growth leading to poor film formation. This problem was addressed by introducing cationic surfactant in the electroless plating process known as surfactant induced electroless plating (SIEP). The unique features of this innovation provide control of Pd-deposition rate, and Pd-grain size distribution. The surfactant molecules play an important role in the EP process by tailoring grain size and the process of agglomeration by removing tiny gas bubbles through adsorption at the gas-liquid interface. As a result surfactant can tailor a nanocrystalline Pd, Cu and Ag deposition in the film resulting in reduced membrane film thickness. Also, it produces a uniform, agglomerated film structure. The Pd-Cu and Pd-Ag membranes on MPSS support were fabricated by sequential deposition using SIEP method. The pre- and post-annealing characterizations of these membranes (Pd, Pd-Cu and Pd-Ag on MPSS substrate) were carried out by SEM, EDX, XRD, and AFM studies. The SEM images show significant improvement of the membrane surface morphology, in terms of metal grain structures and grain agglomeration compared to the membranes fabricated by conventional EP process. The SEM images and helium gas-tightness studies indicate that dense and thinner films of Pd, Pd-Cu and Pd-Ag membranes can be produced with shorter deposition time using surfactant. H 2 Flux through the membranes fabricated by SIEP shows large improvement compared to those by CEP with comparable permselectivity. Pd-MPSS composite membrane was subjected to test for long term performance and thermal cycling (573 - 723 - 573 K) at 15 psi pressure drop for 1200 hours. Pd membranes showed excellent hydrogen permeability and thermal stability during the operational period. Under thermal cycling (573 K - 873 K - 573 K), Pd-Cu-MPSS membrane was stable and retained hydrogen permeation characteristics for over three months of operation. From this limited study, we conclude that SIEP is viable method for fabrication of defect-free, robust Pd-alloy membranes for high-temperature H 2 -separation applications.

08 HYDROGEN↗

Gas Production From a Cold, Stratigraphically Bounded Hydrate Deposit at the Mount Elbert Site, North Slope, Alaska

As part of an effort to identify suitable targets for a planned long-term field test, we investigate by means of numerical simulation the gas production potential from unit D, a stratigraphically bounded (Class 3) permafrost-associated hydrate occurrence penetrated in the ount Elbert well on North Slope, Alaska. This shallow, low-pressure deposit has high porosities, high intrinsic permeabilities and high hydrate saturations. It has a low temperature because of its proximity to the overlying permafrost. The simulation results indicate that vertical ells operating at a constant bottomhole pressure would produce at very low rates for a very long period. Horizontal wells increase gas production by almost two orders of magnitude, but production remains low. Sensitivity analysis indicates that the initial deposit temperature is y the far the most important factor determining production performance (and the most effective criterion for target selection) because it controls the sensible heat available to fuel dissociation.

54 ENVIRONMENTAL SCIENCES↗