Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Analytical and EZmock covariance validation for the DESI 2024 results

The estimation of uncertainties in cosmological parameters is an important challenge in Large-Scale-Structure (LSS) analyses. For standard analyses such as Baryon Acoustic Oscillations (BAO) and Full-Shape two approaches are usually considered. First: analytical estimates of the covariance matrix use Gaussian approximations and (nonlinear) clustering measurements to estimate the matrix, which allows a relatively fast and computationally cheap way to generate matrices that adapt to an arbitrary clustering measurement. On the other hand, sample covariances are an empirical estimate of the matrix based on an ensemble of clustering measurements from fast and approximate simulations. While more computationally expensive due to the large amount of simulations and volume required, these allow us to take into account systematics that are impossible to model analytically. In this work we compare these two approaches in order to enable DESI's key analyses. We find that the configuration space analytical estimate performs satisfactorily in BAO analyses and its flexibility in terms of input clustering makes it the fiducial choice for DESI's 2024 BAO analysis. On the contrary, the analytical computation of the covariance matrix in Fourier space does not reproduce the expected measurements in terms of Full-Shape analyses, which motivates the use of a corrected mock covariance for DESI's 2024 Full Shape analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

A hybrid machine-learning approach for analysis of methane hydrate formation dynamics in porous media with synchrotron CT imaging

Fast multi-phase processes in methane hydrate bearing samples pose a challenge for quantitative micro-computed tomography study and experiment steering due to complex tomographic data analysis involving time-consuming segmentation procedures. This is because of the sample's multi-scale structure, which changes over time, low contrast between solid and fluid materials, and the large amount of data acquired during dynamic processes. Here, a hybrid approach is proposed for the automatic segmentation of tomographic data from time-resolved imaging of methane gas-hydrate formation in sandy granular media, which includes a deep-learning 3D U-Net model. To prepare a training dataset for the 3D U-Net, a technique to automate data labeling based on sample-specific information about the mineral matrix immobility and occasional fluid movement in pores is proposed. Automatic segmentation allowed for studying properties of the hydrate growth in pores, as well as dynamic processes such as incremental flow and redistribution of pore brine. Results of the quantitative analysis showed that for typical gas-hydrate stability parameters (100 bar methane pressure, 7°C temperature) the rate of formation is slow (less than 1% per hour), after which the surface area of contact between brine and gas increases, resulting in faster formation (2.5% per hour). Hydrate growth reaches the saturation point after 11 h of the experiment. Finally, the efficacy of the proposed segmentation scheme in on-the-fly automatic data analysis and experiment steering with zooming to regions of interest is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status Summary of FY16 Atom Probe Tomography Studies on UCSB ATR-2 Irradiated RPV Steels

The University of California Santa Barbara-2 RPV Steel Irradiation experiment was awarded in 2010 by the Nuclear Science User Facility (formerly ATR NSUF) through a competitive peer review proposal process. The experiment involved irradiation of nearly 1300 samples distributed over 13 capsules. The major objective of this experiment was to better understand embrittlement behavior of reactor pressure steels at doses beyond which available data exists yet may be achieved if reactor operating licenses are extended beyond 60 years. The experiment was instrumented during irradiation and active temperature control was used to maintain the temperature at the design temperature. Six samples were selected from a large matrix of materials to perform atom probe tomography (APT) to look at formation of high dose phases. The nature and formation behavior of these phases is discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Classification of subsurface objects using singular values derived from signal frames

The classification system represents a detected object with a feature vector derived from the return signals acquired by an array of N transceivers operating in multistatic mode. The classification system generates the feature vector by transforming the real-valued return signals into complex-valued spectra, using, for example, a Fast Fourier Transform. The classification system then generates a feature vector of singular values for each user-designated spectral sub-band by applying a singular value decomposition (SVD) to the N.times.N square complex-valued matrix formed from sub-band samples associated with all possible transmitter-receiver pairs. The resulting feature vector of singular values may be transformed into a feature vector of singular value likelihoods and then subjected to a multi-category linear or neural network classifier for object classification.

97 MATHEMATICS AND COMPUTING↗

MEASUREMENTS OF BLACK CARBON PARTICLES CHEMICAL, PHYSICAL, AND OPTICAL PROPERTIES

Accurate measurements of the chemical, physical, and optical properties of aerosol particles containing black carbon are necessary to improve current estimates of the radiative forcing in the atmosphere. A collaborative research effort between Aerodyne Research, Inc. and Boston College has focused on conducting field and laboratory experiments on carbonaceous particles and the development and characterization of new particulate instrumentation. This presentation will focus on the chemical, physical, and optical properties of black carbon particles measured in the laboratory in order to understand the effects of atmospheric processing on black carbon particles. Results from a three-week study during July 2008 of mass- and optical-based black carbon measurements will be presented. The project utilized the Boston College laboratory flame apparatus and aerosol conditioning and characterization equipment. A pre-mixed flat flame burner operating at controlled fuel-to-air ratios produced stable and reproducible concentrations of soot particles with known sizes, morphologies, and chemical compositions. In addition, other black carbon particle types, including fullerene soot, glassy carbon spheres, oxidized flame soot, Regal black, and Aquadag, were also atomized, size selected, and sampled. The study covered an experimental matrix that systematically selected particle mobility size (30 to 300 nm) and black carbon particle mass, particle number concentration, particle shape (dynamic shape factor and fractal dimension), and particle chemistry and density (changed via coatings). Particles were coated with a measured thickness (few nm to {approx}150 nm) of sulfuric acid or bis (2-ethylhexyl) sebacate and passed through a thermal denuder to remove the coatings. Highlights of the study to be presented include: (1) Characterization of the chemical and physical properties of various types of black carbon particles, (2) Mass specific absorption measurements as a function of fuel-to-air ratio and carbon particle type, (3) Optical absorption nhancement measurements as a function of coatings, and (4) Particle shape determination as a function of fuel-to-air ratio and collapse observed due to coatings.

54 ENVIRONMENTAL SCIENCES↗

Modifications of local structures of Gd{sub 2}O{sub 3} on incorporation of SiO{sub 2}

In the present work we have reported the results of investigations on local structures of e-beam evaporated (Gd{sub 2}O{sub 3}-SiO{sub 2}) composite thin films by synchrotron based EXAFS measurements. The evolution of local structure in the case of the Gd{sub 2}O{sub 3}-SiO{sub 2} system is found to be different from the HfO{sub 2}-SiO{sub 2} system reported by us earlier. The EXAFS analysis has shown that the Gd-O bond length decreases monotonically as SiO{sub 2} content in the films increases. Also the amplitudes of the peaks in the FT-EXAFS spectra of the samples, which depend jointly on the coordination numbers as well as the Debye-Waller factors (measure of disorder) are found to decrease monotonically with increase in SiO{sub 2} contents in the Gd{sub 2}O{sub 3} matrix. Atomic force microscopy (AFM) measurements of the samples also show continuous evolution of amorphous-like denser microstructure with increase in SiO{sub 2} content in the films. Hence incorporation of SiO{sub 2} in the Gd{sub 2}O{sub 3} matrix, results in a continuous change in oxygen coordination yielding a change in the Gd-O bond length and also results in a continuous increase in amorphousness and a smoother morphology of the samples and, unlike the HfO{sub 2}-SiO{sub 2} system, does not show any maximum for a particular SiO{sub 2} concentration.

36 MATERIALS SCIENCE↗

Italian WEEE management system and treatment of end-of-life cooling and freezing equipments for CFCs removal

Highlights: • Italian data about WEEE management in the period 2005–2010 have been reported. • In 2001–2004 CFC release was monitored and Po Valley resulted as main source region. • The Italian directive on WEEE management was enacted in 2005 but took effect in 2008. • The CFC analytic procedures of the audit assessments have been discussed. - Abstract: This study presents and analyzes the data of the Italian system for take-back and recovery of waste electrical and electronic equipments (WEEEs) in the start-up period 2008–2010. The analysis was focused particularly on the data about the treatment of end-of-life cooling and freezing equipments. In fact, the wastes of cooling and freezing equipments have a high environmental impact. Indeed, in their compressor oil and insulation polyurethane (PU) foams chlorofluorocarbon (CFC) ozone-depleting gases are still present. In the period 2001–2004 Northern Italy resulted the main source in Europe of CFCs. The European Directive on WEEE management was enacted in 2002, but in Italy it was implemented by the legislative Decree in 2005 and it became operational in 2008. Actually, in 2008 the national WEEE Coordination Centre was founded in order to organize the WEEE pick-up process and to control collection, recovery and recycling targets. As a result, in 2010 the average WEEE collection per capita exceeded the threshold of more than 4 kg per inhabitant, as well as cooling and freezing appliances represented more than one fourth of the Italian WEEE collection stream. During the treatment of end-of-life cooling and freezing equipments, CFCs were recovered and disposed principally by burner methods. The analyses of defined specimens collected in the treatment facilities were standardized to reliably determine the amount of recovered CFCs. Samples of alkaline solid salt, alkaline saline solution, polyurethane matrix and compressor oil collected during the audit assessment procedure were analyzed and the results were discussed. In particular, the analysis of PU samples after the shredding and the warm pressing procedures measured a residual CFCs content around 500–1300 mg/kg of CFCs within the foam matrix.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DNA Sequencing Using capillary Electrophoresis

The overall goal of this program was to develop capillary electrophoresis as the tool to be used to sequence for the first time the Human Genome. Our program was part of the Human Genome Project. In this work, we were highly successful and the replaceable polymer we developed, linear polyacrylamide, was used by the DOE sequencing lab in California to sequence a significant portion of the human genome using the MegaBase multiple capillary array electrophoresis instrument. In this final report, we summarize our efforts and success. We began our work by separating by capillary electrophoresis double strand oligonucleotides using cross-linked polyacrylamide gels in fused silica capillaries. This work showed the potential of the methodology. However, preparation of such cross-linked gel capillaries was difficult with poor reproducibility, and even more important, the columns were not very stable. We improved stability by using non-cross linked linear polyacrylamide. Here, the entangled linear chains could move when osmotic pressure (e.g. sample injection) was imposed on the polymer matrix. This relaxation of the polymer dissipated the stress in the column. Our next advance was to use significantly lower concentrations of the linear polyacrylamide that the polymer could be automatically blown out after each run and replaced with fresh linear polymer solution. In this way, a new column was available for each analytical run. Finally, while testing many linear polymers, we selected linear polyacrylamide as the best matrix as it was the most hydrophilic polymer available. Under our DOE program, we demonstrated initially the success of the linear polyacrylamide to separate double strand DNA. We note that the method is used even today to assay purity of double stranded DNA fragments. Our focus, of course, was on the separation of single stranded DNA for sequencing purposes. In one paper, we demonstrated the success of our approach in sequencing up to 500 bases. Other application papers of sequencing up to this level were also published in the mid 1990's. A major interest of the sequencing community has always been read length. The longer the sequence read per run the more efficient the process as well as the ability to read repeat sequences. We therefore devoted a great deal of time to studying the factors influencing read length in capillary electrophoresis, including polymer type and molecule weight, capillary column temperature, applied electric field, etc. In our initial optimization, we were able to demonstrate, for the first time, the sequencing of over 1000 bases with 90% accuracy. The run required 80 minutes for separation. Sequencing of 1000 bases per column was next demonstrated on a multiple capillary instrument. Our studies revealed that linear polyacrylamide produced the longest read lengths because the hydrophilic single strand DNA had minimal interaction with the very hydrophilic linear polyacrylamide. Any interaction of the DNA with the polymer would lead to broader peaks and lower read length. Another important parameter was the molecular weight of the linear chains. High molecular weight (> 1 MDA) was important to allow the long single strand DNA to reptate through the entangled polymer matrix. In an important paper, we showed an inverse emulsion method to prepare reproducibility linear polyacrylamide polymer with an average MWT of 9MDa. This approach was used in the polymer for sequencing the human genome. Another critical factor in the successful use of capillary electrophoresis for sequencing was the sample preparation method. In the Sanger sequencing reaction, high concentration of salts and dideoxynucleotide remained. Since the sample was introduced to the capillary column by electrokinetic injection, these salt ions would be favorably injected into the column over the sequencing fragments, thus reducing the signal for longer fragments and hence reading read length. In two papers, we examined the role of individual components from the sequencing reaction and then developed a protocol to reduce the deleterious salts. We demonstrated a robust method for achieving long read length DNA sequencing. Continuing our advances, we next demonstrated the achievement of over 1000 bases in less than one hour with a base calling accuracy of between 98 and 99%. In this work, we implemented energy transfer dyes which allowed for cleaner differentiation of the 4 dye labeled terminal nucleotides. In addition, we developed improved base calling software to help read sequencing when the separation was only minimal as occurs at long read lengths. Another critical parameter we studied was column temperature. We demonstrated that read lengths improved as the column temperature was increased from room temperature to 60 C or 70 C. The higher temperature relaxed the DNA chains under the influence of the high electric field.

59 BASIC BIOLOGICAL SCIENCES↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The plug-based nanovolume Microcapillary Protein Crystallization System (MPCS)

The Microcapillary Protein Crystallization System (MPCS) embodies a new semi-automated plug-based crystallization technology which enables nanolitre-volume screening of crystallization conditions in a plasticware format that allows crystals to be easily removed for traditional cryoprotection and X-ray diffraction data collection. Protein crystals grown in these plastic devices can be directly subjected to in situ X-ray diffraction studies. The MPCS integrates the formulation of crystallization cocktails with the preparation of the crystallization experiments. Within microfluidic Teflon tubing or the microfluidic circuitry of a plastic CrystalCard, {approx}10-20 nl volume droplets are generated, each representing a microbatch-style crystallization experiment with a different chemical composition. The entire protein sample is utilized in crystallization experiments. Sparse-matrix screening and chemical gradient screening can be combined in one comprehensive 'hybrid' crystallization trial. The technology lends itself well to optimization by high-granularity gradient screening using optimization reagents such as precipitation agents, ligands or cryoprotectants.

59 BASIC BIOLOGICAL SCIENCES↗

Flow annealed importance sampling bootstrap meets differentiable particle physics

High-energy physics requires the generation of large numbers of simulated data samples from complex but analytically tractable distributions called matrix elements. Surrogate models, such as normalizing flows, are gaining popularity for this task due to their computational efficiency. We adopt an approach based on flow annealed importance sampling bootstrap (FAB) that evaluates the differentiable target density during training and helps avoid the costly generation of training data in advance. We show that FAB reaches higher sampling efficiency with fewer target evaluations in high dimensions in comparison to other methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suppression of unimolecular decay of laser desorbed peptide and protein ions by entrainment in rarefied supersonic gas jets under weak electric fields

Unimolecular decay of sample ions imposes a limit on the usable laser fluence in matrix-assisted laser desorption/ionization (MALDI) ion sources. Traditionally, some modest degree of collisional sample ion cooling has been achieved by connecting MALDI ion sources directly to gas-filled radio frequency (RF) multipoles. It was also discovered in the early 1990s that gas-filled RF multipoles exhibit increased ion transmission efficiency due to collisional ion focusing effects. This unexpected experimental finding was later supported by elementary Monte Carlo simulations. Both experiments and simulations assumed a resting background gas with typical pressures of the order of 1 Pa. However, considerable additional improvements can be achieved if laser desorbed sample ions are introduced immediately after desorption, still within the ion source, in an axisymmetric rarefied supersonic gas jet with peak pressure of the order of 100 Pa and flow velocities >300 m/s, and under weak electric fields. We describe here the design principle and report performance data of an ion source coined “MALDI-2,” which incorporates elements of both rarefied aerodynamics and particle optics. Such a design allows superb suppression of metastable fragmentation due to rapid collisional cooling in <10 μs and nearly perfect injection efficiency into the attached RF ion guide, as numerous experiments have confirmed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and structure of undoped and indium-doped thermoelectric lead telluride nanoparticles

Undoped and indium (In)-doped lead telluride (PbTe) nanostructures were synthesized via solvothermal/hydrothermal route. The crystalline structure of the as-prepared undoped and In-doped PbTe samples was examined by X-ray diffraction (XRD) which indicated the formation of face-centered single-phase cubic crystal. A first principle calculation on indium doping shows that the indium atoms are more likely to replace lead (Pb) rather than to take the interstitial sites. Laser-induced breakdown spectroscopy (LIBS) analysis confirms that indium is incorporated into the PbTe matrix of the indium-doped PbTe samples. The effects of surfactant and synthesis temperature on the structure and morphology of the undoped PbTe were also investigated; it was found that PbTe nanostructures synthesized with the addition of surfactants exhibited uniform shapes and their size increased with the synthesis temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retention of Cr in Meta-kaolin-based geo-polymeric Materials under Oxidation and Carbonation - 17453

Alkali activated alumino-silicates, often referred to as geo-polymers, are considered promising immobilization matrices for contaminants due to their high sorption capacity, durability and low leachability. For some contaminants they may prove superior to cement pastes that are conventional immobilization materials in waste management applications. However, estimating the retention capacity of some contaminants under environmental conditions that include oxidation and carbonation and may induce a valance change, is complicated. These contaminants tend to be soluble under oxidizing condition and form precipitates under reducing conditions. Thus, contaminant retention is highly dependent on the initial oxidation state at which the metal was introduced, as well as the matrix sorption ability, ability to resist oxidation and carbonation, and the contaminant leachability. Moreover, carbonation in considered one of the most important degradation mechanisms in cementitious material, causing porosity reduction and significant changes in contaminant leachability, however, geo-polymers have considerably lower Ca content relative to cements, or none, and the effect of carbonation on these pastes is less clear. Thus, contaminant release mechanisms and rates must be estimated based upon exposure to various atmospheres appropriate to waste management applications. In this study we aim to estimate the sorption capacity, and leachability of Cr from a meta-kaolin based geo-polymer, doped with Cr, as a function of its oxidation state and carbonation. Cr has a high valance range from +6 to 0 similar to Tc, and is used as its simulant in the current study. Sodium dichromate was used as an oxidized source metal material. To induce reducing conditions, ascorbic acid was added except for experimental control cases. The samples were aged under N{sub 2}, 98% N{sub 2} + 2% CO{sub 2}, CO{sub 2} deficient air and air environments under constant relative humidity. Following aging, samples were subject to equilibrium leaching as a function of pH (EPA Method 1313) and monolith mass transport rate testing (EPA Method 1315). Mass balance calculations, based on the results of a pH dependent leaching test, have shown that oxidized Cr samples lost 85-95% of their Cr content, whereas, the reduced Cr samples lost only 20% of their Cr content. On the other hand, the leachability of Si and Al is much higher in the reduced-Cr samples then in the samples with oxidized Cr, and their natural pH is up to 2.5 pH units lower than that of the oxidizing cases. Thus, we conclude that the combination of the reducing agent and the spike chemistry influence the matrix formation. Sample aging have not resulted in any significant change in the Cr-leaching behavior of the oxidizing matrices in the pH dependent leaching test, although a significant decrease in the natural pH, of 1.5 pH unit, was observed upon exposure to elevated CO{sub 2} levels (2%), probably due to the formation of Na-carbonate species. The pH and leaching behavior of the reduced Cr samples under the various aging conditions have not yielded significant variation either in their natural pH or in their leaching behavior. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory-based characterization of plutonium in soil particles using micro-XRF and 3D confocal XRF

The investigation of plutonium (Pu) in a soil matrix is of interest in safeguards, nuclear forensics, and environmental remediation activities. The elemental composition of two plutonium contaminated soil particles was characterized nondestructively using a pair of micro X-ray fluorescence spectrometry (micro-XRF) techniques including high resolution X-ray (hiRX) and 3D confocal XRF. The three dimensional elemental imaging capability of confocal XRF permitted the identification two distinct Pu particles within the samples: one external to the Ferich soil matrix and another co-located with Cu within the soil matrix. The size and morphology of the particles was assessed with X-ray transmission microscopy and micro X-ray computed tomography (micro-CT) providing complementary morphological information. Limits of detection for a 30 μm Pu particle are <10 ng for each of the XRF techniques. Ultimately, this study highlights the capability for lab-based, nondestructive, spatially resolved characterization of heterogeneous matrices on the micrometer scale with nanogram sensitivity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Development of small particle speciation for nuclear forensics by soft X-ray scanning transmission spectromicroscopy

Synchrotron radiation spectromicroscopy provides a combination of submicron spatial resolution and chemical sensitivity that is well-suited to analysis of heterogeneous nuclear materials. The chemical and physical characteristics determined by scanning transmission X-ray microscopy (STXM) are complementary to information obtained from standard radiochemical analysis methods. In addition, microscopic quantities of radioactive material can be characterized rapidly by STXM with minimal sample handling and intrusion, especially in the case of particulate materials. The STXM can accommodate a diverse range of samples including wet materials, complex mixtures, and small quantities of material contained in a larger matrix. In these cases, the inventory of species present in a sample is likely to carry information on its process history; STXM has the demonstrated capability to identify contaminants and sample matrices. Operating in the soft X-ray regime provides particular sensitivity to the chemical state of specimens containing low-Z materials, via the K-edges of light elements. In this paper, recent developments in forensics-themed spectromicroscopy, sample preparation, and data acquisition methods at the Molecular Environmental Science Beamline 11.0.2 of the Advanced Light Source are described. Results from several initial studies are presented, demonstrating the capability to identify the distribution of the species present in heterogeneous uranium-bearing materials. Finally, future opportunities for STXM forensic studies and potential methodology development are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quickest Detection for Changes in Maximal kNN Coherence of Random Matrices

This paper addresses the problem of quickest detection of a change in the maximal coherence between columns of a n p random matrix based on a sequence of matrix observations having a single unknown change point. The random matrix is assumed to have identically distributed rows and the maximal coherence is defined as the largest of the ( 2 p) correlation coefficients associated with any row. Likewise the κ nearest neighbor (kNN) coherence is defined as the κ-th largest of these correlation coefficients. The forms of the preand postchange distributions of the observed matrices are assumed to belong to the family of elliptically contoured densities with sparse dispersion matrices but are otherwise unknown. A nonparametric stopping rule is proposed that is based on the maximal kNN sample coherence between columns of each observed random matrix. This is a summary statistic that is related to a test of existence of a hub vertex in a sample correlation graph having degree at least κ. Performance bounds on the delay and false alarm performance of the proposed stopping rule are obtained in the purely high-dimensional regime where p → ∞ and n is fixed. When the prechange dispersion matrix is diagonal it is shown that, among all functions of the proposed summary statistic, the proposed stopping rule is asymptotically optimal under a minimax quickest change detection model as the stopping threshold approaches infinity. Furthermore, the theory developed also applies to sequential hypothesis testing and fixed sample size tests.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗