Search NASA⌕ Search

SEARCH · Search NASA

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Photosynthetically Active Radiation (PAR) Instrument Handbook

Three photosynthetically active radiation (PAR) measurement instruments were deployed at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Bankhead National Forest (BNF) observatory, installed on three different instrument towers within the forest. Each of the three instruments comprises an enclosure at the base of the tower, containing a datalogger and internal humidity sensor, connected to external PAR sensors mounted at various heights and vertical orientations on the same tower. PAR sensors measure radiation reaching the sensor with wavelengths from 400-700 nm, per unit area, per unit time, or the photosynthetic photon flux density (PPFD, µmol photons m -2 s -1 ). On the 43-meter tower of BNF supplemental site S10, sensors are located 43 m, 22 m, 10 m, and 5 m from ground level. Downwelling radiation is measured with upward-facing sensors at all heights, and upwelling radiation is measured with downward-facing sensors at 43 m and 5 m. On the two 10-m towers of BNF supplemental sites S13 and S14, upwelling radiation is measured at 8 m and 2 m, and downwelling radiation is measured at 8 m.

54 ENVIRONMENTAL SCIENCES↗

Measuring Tension In A Tether

Proposed instrument measures tension in tether and transmits data on tension so tension monitored or adjusted as necessary. Positioned along length of tether, which measures tension only at ends. Device includes strain gauge to sense tension. Output of strain gauge controls modulation of battery- or solar-powered radio transmitter. In another version, transmitter receives radio signal on one frequency and returns signal on another frequency with modulation signifying tension. Yet another version, data on tension carried on beam of light. Laser-diode transmitter powered by battery, radio beam, beam of light, or solar energy.

Hinman, E. M.↗

Transforming Vectors Measured By Noncoaligned Instruments

Method for computing relationships between coordinate axes of two vector-measuring instruments not aligned with each other, one need only measure two nonparallel vectors u and v simultaneously in both coordinate systems. These measurements provide all data needed to compute transformation of any vector from one coordinate system to other. Particularly useful in computing alignments and transformations between accelerometers, gyroscopes, and instruments mounted on platforms subjected to vibrations, thermal strains, and other distortions causing alignments to vary unpredictably with time.

Ritter, James R.↗

Polarization Modeling of the MODIS Instrument

Sunlight reflected from the earth is, to a certain extent, polarized. Radiometers, such as the MODIS instrument on board the TERRA and AQUA spacecraft, are to a certain extent polarizers. Accurate radiometric measurements must take into account both the polarization state of the scene and the polarization sensitivity of the measuring instrument. The measured polarization characteristics of the MODIS instruments are contained in various radiometric models. Continued use of these radiometric math models, over a number of years, have shown where these models can be improved. The current MODIS polarization modeling effort is discussed in the context and limitations of past modeling efforts.

Waluschka, Eugene↗

Improved Instrument for Detecting Water and Ice in Soil

An instrument measures electrical properties of relatively dry soils to determine their liquid water and/or ice contents. Designed as a prototype of instruments for measuring the liquid-water and ice contents of lunar and planetary soils, the apparatus could also be utilized for similar purposes in research and agriculture involving terrestrial desert soils and sands, and perhaps for measuring ice buildup on aircraft surfaces. This instrument is an improved version of the apparatus described in Measuring Low Concentrations of Liquid Water and Ice in Soil (NPO-41822), NASA Tech Briefs, Vol. 33, No. 2 (February 2009), page 22. The designs of both versions are based on the fact that the electrical behavior of a typical soil sample is well approximated by a network of resistors and capacitors in which resistances decrease and capacitances increase (and the magnitude and phase angle of impedance changes accordingly) with increasing water content. The previous version included an impedance spectrometer and a jar into which a sample of soil was placed. Four stainless-steel screws at the bottom of the jar were used as electrodes of a fourpoint impedance probe connected to the spectrometer. The present instrument does not include a sample jar and can be operated without acquiring or handling samples. Its impedance probe consists of a compact assembly of electrodes housed near the tip of a cylinder. The electrodes protrude slightly from the cylinder (see Figure 1). In preparation for measurements, the cylinder is simply pushed into the ground to bring the soil into contact with the electrodes.

Buehler, Martin↗

Tracking NO2 Pollution Changes Over Texas: Synthesis of In Situ and Satellite Observations

Nitrogen oxides (NO x ) are major air pollutants that play a crucial role in atmospheric chemistry. We compare Ozone Measuring Instrument's (OMI) NO 2 records with the in situ surface measurements from the Air Quality System of the US Environmental Protection Agency and the Texas Commission on Environmental Quality network in the state of Texas with the goal of understanding the correspondence of satellite and in situ surface observations and identifying the potential synergies between the two observing systems. Our analysis of over 40 in situ daily surface site observations, mostly from urban areas, and OMI daily observed data suggests a correlation ( r ) ranging between 0.2 and 0.8. The correlation improves considerably ( r > 0.5) for monthly average data. Weekly variation of surface NO 2 with a Sunday minimum is well captured by OMI tropospheric NO 2 column observations with similar weekend reductions. NO 2 trend in Texas during 2005–2019 is characterized by significant reductions of 20%–36% in highly populated cities and urban centers. However, a significant (up to 80%) increase was observed in oil and gas producing regions of the Permian and Eagle Ford Basins over the same period. In March–April of 2020, like the other US and global cities, Texas experienced up to 60% reduction in NO 2 levels in major cities due to travel restrictions imposed at local and national levels to contain the spread of COVID-19. Though such reduction is temporary, these reductions were significantly larger than those achieved in the past 16 years of OMI record suggesting that technological advancement can curtail NO x emissions.

Nitrogen dioxide (NO2)↗

Measurement and Modeling of Solar and PV Output Variability: Preprint

This paper seeks to understand what temporal and spatial scales of variability in global horizontal radiation are important to a PV plants and what measurements are needed to be able to characterize them. As solar radiation measuring instruments are point receivers it is important to understand how those measurements translate to energy received over a larger spatial extent. Also of importance isthe temporal natural of variability over large spatial areas. In this research we use high temporal and spatial resolution measurements from multiple sensors at a site in Hawaii to create solar radiation fields at various spatial and temporal scales. Five interpolation schemes were considered and the high resolution solar fields were converted to power production for a PV power plant. It wasfound that the interpolation schemes are robust and create ramp distributions close to what would be computed if the average solar radiation field was used. We also investigated the possibility of using time averaged solar data from 1 sensor to recreate the ramp distribution from the 17 sensors. It was found that the ramping distribution from using appropriately time averaged data from 1 sensorcan reasonably match the distribution created using the 17 sensor network.

14 SOLAR ENERGY↗

Measurement and Modeling of Solar and PV Output Variability

This paper seeks to understand what temporal and spatial scales of variability in global horizontal radiation are important to a PV plants and what measurements are needed to be able to characterize them. As solar radiation measuring instruments are point receivers it is important to understand how those measurements translate to energy received over a larger spatial extent. Also of importance is the temporal natural of variability over large spatial areas. In this research we use high temporal and spatial resolution measurements from multiple sensors at a site in Hawaii to create solar radiation fields at various spatial and temporal scales. Five interpolation schemes were considered and the high resolution solar fields were converted to power production for a PV power plant. It was found that the interpolation schemes are robust and create ramp distributions close to what would be computed if the average solar radiation field was used. We also investigated the possibility of using time averaged solar data from 1 sensor to recreate the ramp distribution from the 17 sensors. It was found that the ramping distribution from using appropriately time averaged data from 1 sensor can reasonably match the distribution created using the 17 sensor network.

14 SOLAR ENERGY↗

Aerosol hygroscopic growth, contributing factors, and impact on haze events in a severely polluted region in northern China

This study investigates the impact of the aerosol hygroscopic growth effect on haze events in Xingtai, a heavily polluted city in the central part of the North China Plain (NCP), using a large array of instruments measuring aerosol optical, physical, and chemical properties. Key instruments used and measurements made include the Raman lidar for atmospheric water vapor content and aerosol optical profiles, the PC-3016A GrayWolf six-channel handheld particle and mass meter for atmospheric total particulate matter (PM) that has diameters less than 1 and 2.5 µ m (PM 1 and PM 2.5 , respectively), the aerosol chemical speciation monitor (ACSM) for chemical components in PM 1 , and the hygroscopic tandem differential mobility analyzer (H-TDMA) for aerosol hygroscopicity. The changes in PM 1 and PM 2.5 agreed well with that of the water vapor content due to the aerosol hygroscopic growth effect. Two cases were selected to further analyze the effects of aerosol hygroscopic growth on haze events. The lidar-estimated hygroscopic enhancement factor for the aerosol backscattering coefficient during a relatively clean period (Case I) was lower than that during a pollution event (Case II) with similar relative humidity (RH) levels of 80 %–91 %. The Kasten model was used to fit the aerosol optical hygroscopic growth factor (GF) whose parameter b differed considerably between the two cases, i.e., 0.1000 (Case I) versus 0.9346 (Case II). The aerosol acidity value calculated from ACSM data for Case I (1.35) was less than that for Case II (1.50) due to different amounts of inorganics such as NH 4 NO 3 , NH 4 HSO 4 , and (NH 4 ) 2 SO 4 . Model results based on H-TDMA data showed that aerosol hygroscopic growth factors in each size category (40, 80, 110, 150, and 200 nm) at different RH levels (80 %–91 %) for Case I were lower than those for Case II. For similar ambient RH levels, the high content of nitrate facilitates the hygroscopic growth of aerosols, which may be a major factor contributing to heavy haze episodes in Xingtai.

Chen, Jun↗

Instrumentation

Mass spectrometry, Mossbauer spectrometry, and radioactivity measuring instruments

Haramic, M.↗

Measuring the thickness of plastic films

Optical instrument measures thickness of translucent and transparent sheets in thickness range from 2 to 8 microns by monitoring attenuation of light as it passes through sheet.

Donohoe, K. C.↗

Measuring Contact Thermal Conductances at Low Temperatures

Instrument measures thermal conductance of pressed contacts in liquid helium. Makes measurements automatically as function of force on pairs of brass samples having various surface finishes. Developed as part of effort to determine heat-transfer characteristics of bolted joints on cryogenically cooled focal planes in infrared equipment. Cylindrical chamber hangs from cover plate in bath of liquid helium. Inside chamber rocker arm applies controlled force to samples. Upper sample made slightly wider than lower one so two samples remain in complete contact even under slight lateral misalignment.

Salerno, Louis J.↗

Finite Difference Radiative Transfer Model Calculations Compared to Measurements at the Top and Bottom of the Atmosphere

A finite difference radiative transfer program was developed to handle most anisotropic scattering and reflectance problems encountered in the Earth's atmospheric system. The model has been used to reproduce the radiance received by both satellite and ground based radiation measuring instruments. It accurately replicates the radiance measured by both narrow and wide field-of-view instruments with either narrow or broadband wavelength ranges located on the surface and at satellite altitudes. The output of the finite difference code is compared to the measurements by surface pyranometers and a spectroradiometer aboard a high flying aircraft. The program output is also compared to ERBE measurements aboard the ERBS and NOAA-9 satellites as well as the visible bands aboard the GOES-6 and GOES-7 satellites and AVHRR bands 1 and 2 of the NOAA-9 and NOAA-1 1 satellites. The model is within 0.2 % of the radiance received by pyranometers, within 0.6 % of the ERBE radiances, and within 3 % of the radiances measured by the visible bands of the GOES and NOAA AVHRR radiometers.

LeCroy, Stuart R.↗

Cyber Framework for Steering and Measurements Collection Over Instrument-Computing Ecosystems

We propose a framework to develop cyber solutions to support the remote steering of science instruments and measurements collection over instrument-computing ecosystems. It is based on provisioning separate data and control connections at the network level, and developing software modules consisting of Python wrappers for instrument commands and Pyro server-client codes that make them available across the ecosystem network. We demonstrate automated measurement transfers and remote steering operations in a microscopy use case for materials research over an ecosystem of Nion microscopes and computing platforms connected over site networks. The proposed framework is currently under further refinement and being adopted to science workflows with automated remote experiments steering for autonomous chemistry laboratories and smart energy grid simulations.

Al Najjar, Anees↗

A technique for the correcting ERTS data for solar and atmospheric effects

A technique is described by which an ERTS investigator can obtain absolute target reflectances by correcting spacecraft radiance measurements for variable target irradiance, atmospheric attenuation, and atmospheric backscatter. A simple measuring instrument and the necessary atmospheric measurements are discussed, and examples demonstrate the nature and magnitude of the atmospheric corrections.

Rogers, R. H.↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Pulse energy measurement at the SXR instrument

A gas monitor detector was implemented and characterized at the Soft X-ray Research (SXR) instrument to measure the average, absolute and pulse-resolved photon flux of the LCLS beam in the energy range between 280 and 2000 eV. The detector is placed after the monochromator and addresses the need to provide reliable absolute pulse energy as well as pulse-resolved measurements for the various experiments at this instrument. This detector provides a reliable non-invasive measurement for determining flux levels on the samples in the downstream experimental chamber and for optimizing signal levels of secondary detectors and for the essential need of data normalization. The design, integration into the instrument and operation are described, and examples of its performance are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Natural Energy Laboratory of Hawaii Authority (NELHA): Hawaii Ocean Science & Technology Park, Kailua-Kona, Hawaii

A partnership with the Natural Energy Laboratory of Hawaii Authority and U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to collect solar data to support future solar power generation in the United States. The measurement station monitors global horizontal horizontal irradiance to define the amount of solar energy that hits this particular location. The solar measurement instrumentation is also accompanied by meteorological monitoring equipment to provide scientists with a complete picture of the solar power possibilities.

14 SOLAR ENERGY↗