Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Microelectronics reliability : physics-of-failure based modeling and lifetime evaluation

This handbook presents a physics-of-failure approach to microelectronics reliability modeling and assessment. Knowledge of the root cause and physical behavior of key failure mechanisms in microelectronic devices has improved dramatically over recent years and has led to the development of more sophisticated reliability modeling tools and techniques...

White, Mark↗

Rotary Ultrasonic Motors Actuated by Traveling Flexural Waves

Efficient miniature actuators that are compact and consume low power are needed to drive telerobotic devices and space mechanisms in future NASA missions. Ultrasonic rotary motors have the potential to meet this NASA need and they are developed as actuators for miniature telerobotic applications.

Piezoelectric↗

Role of failure-mechanism identification in accelerated testing

Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.

Hu, J. M.↗

Comparison of Orion Flywheel to Commercially Available Flywheel Device

INTRODUCTION: The chosen exercise device for the Orion Multi-purpose Crew Vehicle (MPCV) for Artemis missions is the Orion Flywheel (OFW), which was selected in 2017 from a pool of exercise devices. The Orion Flywheel is to be installed in the MPCV for its first use during the Artemis II mission and will be utilized for subsequent Artemis missions. The OFW provides the capability to perform both resistive and aerobic exercises while taking up a small volume and not requiring power. Aerobic exercise consists of rowing while resistive exercise includes the deadlift, harness squat, and deadlift high pull among others. The efficacy of the OFW as an exercise countermeasure to spaceflight deconditioning has not yet been fully evaluated. A future HRP-funded study using head-down tilt bed rest is planned to evaluate the efficacy of the OFW to mitigate aerobic and muscular deconditioning. The OFW, made by KBR, is a specialized device that poses high costs for purchase and maintenance. The aim of the study is to determine if a commercially available alternative could be used as a backup for the OFW during the bed rest study or as an alternative in other studies. This study seeks to compare the loading profile and mechanics of a commercial flywheel device (kBox Pro) with the three resistance settings of the OFW using a controlled, instrumented setup to validate its acceptability as a backup. METHODS: An experimental setup was designed to simulate human use of the OFW. Flywheel devices can have varied actuated inertial mass and strap length. The inertial mass refers to the flywheel itself or the object that spins as the result of the movement of the strap. The OFW has three gears actuated with a lever, with the low gear used for aerobic rowing and the medium and high gears used for resistance exercises. These gears correspond to increasing flywheel inertia, which corresponds to a certain number and sizes of inertial plates on a commercial flywheel. The kBox Pro has varied sizes of inertial discs that are installed to the external shaft of the device and can be configured to roughly match the inertia seen in the OFW per gear setting. The strap length can be adjusted to allow for different ranges of motion. The experimental setup allows for the simulation of rowing, harness squats, and deadlift high pulls with corresponding exercise strap lengths. All three OFW gears are to be tested, as well as multiple combinations of kBox discs. The setup was created using a system of pulleys and cables to minimize friction loss. The system is actuated through the dropping of a connected mass which, through the pulley system, pulls the strap of the exercise device upwards as if a human was exercising. A string potentiometer and tensile force transducer are used to measure strap displacement and strap force, respectively. The masses dropped are exercise chains that simulate the decrease in force observed throughout a typical exercise. As the chains are lowered to the ground, they begin to spool and therefore are no longer subjecting the exercise device’s strap to their load. This setup was designed to provide realistic loads and protect the OFW from damage, an important precaution because it’s the only available unit for research and ground operations. Data is to be collected across simulated exercises and with different strap lengths, with the same conditions collected on both the OFW and the kBox Pro. RESULTS: Data collection is ongoing for the kBox and the Orion Flywheel. CONCLUSIONS: Study results will inform if the OFW and a kBox Pro device can be deemed mechanically similar. Depending on the results, additional data collection may be required to assess the user experience between the devices. A key result of this study is a mechanical characterization of the OFW device, demonstrating the load and force profile using a repeatable test method. This data will guide next steps on potential kBox Pro modifications needed to produce a comparable exercise experience to the OFW.

Exercise↗

Latch mechanism for the space telescope

Latch mechanisms to secure, release, and relatch deployables on the Space Telescope are described. The latch mechanisms are mechanical pre-loading devices composed of a four-bar linkage driven by an electro-mechanical rotary actuator. The latch mechanism requirements, unique design features, analytical highlights, and the development testing are discussed.

Schmidt, H. F.↗

Model of a Piezoelectric Transducer

It's difficult to control liquid and gas in propellant tanks in zero gravity. A possible a design would utilize acoustic liquid manipulation (ALM) technology which uses ultrasonic beams conducted through a liquid and solid media, to push gas bubbles in the liquid to desirable locations. We can propel and control the bubble with acoustic radiation pressure by aiming the acoustic waves on the bubble s surface. This allows us to design a so called smart tank in which the ALM devices transfer the gas to the outer wall of the tank and isolating the liquid in the center. Because the heat transfer rate of a gas is lower of that of the liquid it would substantially decrease boil off and provide of for a longer storage life. The ALM beam is composed of little wavelets which are individual waves that constructively interfere with each other to produce a single, combined acoustic wave front. This is accomplished by using a set of synchronized ultrasound transducers arranged in an array. A slight phase offset of these elements allows us to focus and steer the beam. The device that we are using to produce the acoustic beam is called the piezoelectric transducer. This device converts electrical energy to mechanical energy, which appears in the form of acoustic energy. Therefore the behavior of the device is dependent on both the mechanical characteristics, such as its density, cross-sectional area, and its electrical characteristics, such as, electric flux permittivity and coupling factor. These devices can also be set up in a number of modes which are determined by the way the piezoelectric device is arranged, and the shape of the transducer. For this application we are using the longitudinal or thickness mode for our operation. The transducer also vibrates in the lateral mode, and one of the goals of my project is to decrease the amount of energy lost to the lateral mode. To model the behavior of the transducers I will be using Pspice, electric circuit modeling tool, to determine the transducer's electrical characteristics at the frequency of interest. This will also help me determine the characteristics of an impedance matching network to operate the transducer at its optimum efficiency. For this I will use ABMs (analog behavioral modeling) to model dependent current and voltage sources that represent the transducer. I have also been working on the Labview control software for the phased array used to control the bubbles, and will begin testing on that before the end of my internship.

Goodenow, Debra↗

Methods of Soft Tissue Emulsification Using a Mechanism of Ultrasonic Atomization Inside Gas or Vapor Cavities and Associated Systems and Devices

The present technology is directed to methods of soft tissue emulsification using a mechanism of ultrasonic atomization inside gas or vapor cavities, and associated systems and devices. In several embodiments, for example, a method of non-invasively treating tissue includes pulsing ultrasound energy from the ultrasound source toward the target site in tissue. The ultrasound source is configured to emit high intensity focused ultrasound (HIFU) waves. The target site comprises a pressure-release interface of a gas or vapor cavity located within the tissue. The method continues by generating shock waves in the tissue to induce a lesion in the tissue at the target site. The method additionally includes characterizing the lesion based on a degree of at least one of a mechanical or thermal ablation of the tissue.

Sapozhnikov, Oleg A.↗

Hold Down and Release Mechanism Hardware Simulator for Ground Deployment Testing

Hold Down and Release Mechanisms (HDRMs) are a common piece of spacecraft hardware which restrain components during launch, transit, and later allow them to be extended, jettisoned, separated, etc. at the spacecraft’s destination. Due to prohibitively high cost, long lead times, and limited reset capability, testing of mechanisms that require HDRMs is often difficult. This project explored the possibility of designing HDRM-analogue devices that would replicate the function of flight HDRMs during ground-based testing for a fraction of the cost of a flight HDRM. These devices were designed with the requirements of the Spin Eject Mechanism to be used on the Mars Sample Return (MSR) Capture, Containment, and Return System (CCRS) in mind. A trade study was conducted to determine the optimal internal mechanism design of the device, comparing several mechanisms from existing HDRMs to several simpler, more novel mechanisms. CAD software was used to create a preliminary design of the device utilizing a mix of commercial off-the-shelf parts and custom-manufactured parts. Several straightforward analyses were conducted to determine the most effective models for the off-the-shelf parts. A prototype largely composed of 3D-printed components was also created to proof the design concept. Although this HDRM simulator was designed for a particular mechanism for the CCRS mission, its general design is useful for ground testing of a variety of mechanisms requiring similar HDRM simulators.

Kian Vilhauer↗

Application of copper-carbon fiber composites to power semiconductor devices

Copper-carbon composite electrodes are used in a series of power semiconductor devices, i.e., resin molded diodes, button-type diodes, stud-type diodes, power modules, and integrated circuit igniter modules. The properties of these power semiconductor devices compare favorably with those conventional devices using Mo or W electrodes. In thermal fatigue tests, no degradation in the electrical and mechanical characteristics of these devices are observed. The new composite electrode with carbon fibers satisfies all of the major requirements for the electrodes in power semiconductor devices.

Kuniya, Keiichi↗

Wearing of cryomechanisms at 4 K

Certain spaceborne optics include components that are designed to improve the instrument's performance. Where such mechanisms cannot be decoupled from the optical devices, pollution from the wear of those mechanisms must be minimized due to impossibility of inflight, or even sometimes on-ground cleaning of optical devices. Aerospatiale, who are responsible for the optical bench of the infrared camera to be flown on board the ISO spacecraft, were therefore led to develop nonpolluting mechanisms. Comparative tests were performed on several couples of materials, resulting in choice of a satisfactory solution.

Luciano, Gerard↗

Locking mechanism for orthopedic braces

An orthopedic brace locking mechanism is described which under standing or walking conditions cannot be unlocked, however under sitting conditions the mechanism can be simply unlocked so as to permit bending of the patient's knee. Other features of the device include: (1) the mechanism is rendered operable, and inoperable, dependent upon the relative inclination of the brace with respect to the ground; (2) the mechanism is automatically locked under standing or walking conditions and is manually unlocked under sitting conditions; and (3) the mechanism is light in weight and is relatively small in size.

Chao, J. I.↗

Two-Fault-Tolerant Release Mechanism

Remotely-operated, compact quick-release mechanism still functions in event that one or even two attempts to actuate it fail. Contains three independent pyrotechnic devices. Firing of any one of devices sufficient to actuate mechanism. Three pins hold toggle at its base. Retraction of any one of pins allows toggle head to rotate in spherical bearing to free itself from remaining pin or pins. Besides allowing rotation after retraction, bearing also aligns toggle during assembly.

Graves, Thomas J.↗

Noise in avalanche transit-time devices.

A survey of work performed on noise in avalanche transit-time devices is presented. Both theoretical and experimental results on noise mechanisms and performance of these devices, when they are employed as oscillators, amplifiers, and self-oscillating mixers, are reviewed. Several unexplained experimental results and points of disagreement between the experimental work results of various workers are identified. Suggestions for further studies are offered.

Gupta, M.↗