Search NASA⌕ Search

SEARCH · Search NASA

Results for “microchannels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Advancements in Heat Transfer and Fluid Mechanics (Fundamentals and Applications)

Thermo-fluid science is a foundational discipline for numerous mechanical systems, particularly in energy production and building equipment, where thermal and mechanical energy transfer play critical roles. Advancements in heat transfer and fluid mechanics have significantly enhanced these systems, driving progress in associated market sectors. For instance, evaporator and condenser coils are essential for optimizing vapor compression cycles in building equipment. Heat pumps used for space and water heating constitute a major share of building systems, with microchannel heat exchanger technology at the forefront of these innovations. It is worth mentioning that advancements in heat transfer and fluid mechanics significantly alleviate the challenge of designing energy-efficient building equipment. The development of research techniques has contributed significantly to the advancement of science; for example, in the experimental field, non-intrusive measurement techniques such as Particle Image Velocimetry (PIV) are now capable of resolving flow behavior in a 3D format for different length and time scales.

42 ENGINEERING↗

Novel Ultrafast Lu2O3:Yb Ceramics for Future HEP Applications

Inorganic scintillators activated by charge transfer luminescence Yb3+ are considered promising ultrafast material to break the ps timing barrier for future high energy physics applications. Inorganic scintillators in ceramic form are potentially more cost-effective than crystals because of their lower fabrication temperature and no need for aftergrowth mechanical processing. This paper reports an investigation on Lu2O3:Yb and Lu2xY2(1−x)O3:Yb scintillating ceramic samples fabricated by Radiation Monitoring Devices Inc. All samples show X-ray excited luminescence peaked at 370 nm. Ultrafast decay time of 1.1 ns was observed by using a microchannel plate-photomultiplier tube-based test bench at Caltech. Considering its intrinsic high density (9.4 g/cm3), Lu2O3:Yb ceramics are promising for future time of fight application for high energy physics experiments.

47 OTHER INSTRUMENTATION↗

A Novel Laser 3D Printing Method for the Advanced Manufacturing of Protonic Ceramics

Protonic ceramics (PCs) with high proton conductivity at intermediate temperatures (300–600 °C) have attracted many applications in energy conversion and storage devices such as PC fuel/electrolysis cells, PC membrane reactors, hydrogen pump, hydrogen or water-permeable membranes, and gas sensors. One of the essential steps for fulfilling the practical utilization of these intermediate-temperature PC energy devices is the successful development of advanced manufacturing methods for cost-effectively and rapidly fabricating them with high energy density and efficiency in a customized demand. In this work, we developed a new laser 3D printing (L3DP) technique by integrating digital microextrusion-based 3D printing and precise and rapid laser processing (sintering, drying, cutting, and polishing), which showed the capability of manufacturing PCs with desired complex geometries, crystal structures, and microstructures. The L3DP method allowed the fabrication of PC parts such as pellets, cylinders, cones, films, straight/lobed tubes with sealed endings, microchannel membranes, and half cells for assembling PC energy devices. The preliminary measurement of the L3DP electrolyte film showed a high proton conductivity of ≈7 × 10−3 S/cm. This L3DP technique not only demonstrated the potential to bring the PCs into practical use but also made it possible for the rapid direct digital manufacturing of ceramic-based devices.

08 HYDROGEN↗

Viscoelastic Particle Focusing and Separation in a Spiral Channel

As one type of non-Newtonian fluid, viscoelastic fluids exhibit unique properties that contribute to particle lateral migration in confined microfluidic channels, leading to opportunities for particle manipulation and separation. In this paper, particle focusing in viscoelastic flow is studied in a wide range of polyethylene glycol (PEO) concentrations in aqueous solutions. Polystyrene beads with diameters from 3 to 20 μm are tested, and the variation of particle focusing position is explained by the coeffects of inertial flow, viscoelastic flow, and Dean flow. We showed that particle focusing position can be predicted by analyzing the force balance in the microchannel, and that particle separation resolution can be improved in viscoelastic flows.

42 ENGINEERING↗

Effect of Preparation Conditions of Fe@SiO2 Catalyst on Its Structure Using High-Pressure Activity Studies in a 3D-Printed SS Microreactor

Fischer–Tropsch synthesis (FTS) in a 3D-printed stainless steel (SS) microchannel microreactor was investigated using Fe@SiO2 catalysts. The catalysts were prepared by two different techniques: one pot (OP) and autoclave (AC). The mesoporous structure of the two catalysts, Fe@SiO2 (OP) and Fe@SiO2 (AC), ensured a large contact area between the reactants and the catalyst. They were characterized by N2 physisorption, H2 temperature-programmed reduction (H2-TPR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), X-ray photoelectron microscopy (XPS), and thermogravimetric analysis–differential scanning calorimetry (TGA-DSC) techniques. The AC catalyst had a clear core–shell structure and showed a much greater surface area than that prepared by the OP method. The activities of the catalysts in terms of FTS were studied in the 200–350 °C temperature range at 20-bar pressure with a H2/CO molar ratio of 2:1. The Fe@SiO2 (AC) catalyst showed higher selectivity and higher CO conversion to olefins than Fe@SiO2 (OP). Stability studies of both catalysts were carried out for 30 h at 320 °C at 20 bar with a feed gas molar ratio of 2:1. The Fe@SiO2 (AC) catalyst showed higher stability and yielded consistent CO conversion compared to the Fe@SiO2 (OP) catalyst.

Biochemistry & Molecular Biology↗

Microfluidic Fabrication Techniques for High-Pressure Testing of Microscale Supercritical CO 2 Foam Transport in Fractured Unconventional Reservoirs

Pressure limitations of many microfluidic platforms have been a significant challenge in microfluidic experimental studies of fractured media. As a result, these platforms have not been fully exploited for direct observation of high-pressure transport in fractures. This work introduces microfluidic platforms that enable direct observation of multiphase flow in devices featuring surrogate permeable media and fractured systems. Such platforms provide a pathway to address important and timely questions such as those related to CO 2 capture, utilization and storage. This work provides a detailed description of the fabrication techniques and an experimental setup that may serve to analyze the behavior of supercritical CO 2 (scCO 2 ) foam, its structure and stability. Such studies provide important insights regarding enhanced oil recovery processes and the role of hydraulic fractures in resource recovery from unconventional reservoirs. This work presents a comparative study of microfluidic devices developed using two different techniques: photolithography/wet-etching/ thermal-bonding versus Selective Laser-induced Etching. Both techniques result in devices that are chemically and physically resistant and tolerant of high pressure and temperature conditions that correspond to subsurface systems of interest. Both techniques provide pathways to high-precision etched microchannels and capable lab-on-chip devices. Photolithography/wet-etching, however, enables fabrication of complex channel networks with complex geometries, which would be a challenging task for laser etching techniques. This work summarizes a step-by-step photolithography, wet-etching and glass thermal-bonding protocol and, presents representative observations of foam transport with relevance to oil recovery from unconventional tight and shale formations. In conclusion, this work describes the use of a high resolution monochromatic sensor to observe scCO 2 foam behavior where the entirety of the permeable medium is observed simultaneously while preserving the resolution needed to resolve features as small as 10 μm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Negative affinity X-ray photocathodes

A new X-ray image intensifier is described. The device should eventually have a quantum efficiency which is an order of magnitude greater than that of presently available high spatial resolution X-ray detectors, such as microchannel plates. The new intesifier is based upon a GaAs crystal photocathode which is activated to achieve negative electron affinity. Details concerning the detector concept are discussed together with the theoretical relations involved, X-ray data, and optical data.

Vanspeybroeck, L.↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Two-dimensional photon detector

Device incorporates set of cascaded microchannel-array plates in proximity focus with two sets of mutually-orthogonal linear anodes. Technique allows data from N x M picture elements to be recorded with only N + M amplifiers.

Timothy, J. G.↗

Resistive anode image converter

The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.

Lampton, M. L.↗

Spectroscopic survey of the far-ultraviolet /1160-1700 A/ emissions of Capella

A far-ultraviolet spectral survey of Capella (Alpha Aur, G5 III + G0 III) has been obtained using a highly sensitive rocketborne spectrograph with a microchannel plate detector. The spectral distribution is very similar to that of the sun; however, if the line surface fluxes are due to the primary (G5 III), then, except for Ly-alpha, they are about an order of magnitude greater than those of the quiet sun

Vitz, R. C.↗

The Photicon

The Photicon is a novel imaging optical detector utilizing a conventional semitransparent photocathode, imaging electrostatic optics, microchannel plates, and a crossed-wire-grid position-sensitive charge detector. Its sensitivity to single optical photons over a two-dimensional area, high-resolution imaging, and timing capability render it useful for recording scintillations from X-ray image converters in X-ray astronomy. A digital word indicating the position of a single photon event is produced; the image can be stored in an array or serially. Spatial resolution to 20 microns in a 25 mm diam active area detector is reported, and modifications to achieve a spectral range of 120-730 nm are mentioned.

Kellogg, E.↗

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

A rocket observation of the far-ultraviolet spectrum of Saturn

Far-ultraviolet (1160-1750 A) spectra of the Saturnian disk and the ring system have been obtained by using a very sensitive rocket-borne spectrograph with a microchannel plate detector. The use of two apertures of different diameter in the telescope focal plane permitted the separation of the contribution of the planetary disk from that of the rings. H I lambda 1216 was the only atomic spectral line emission detected in the planet and the rings. A weak signal from the disk between 1300 A and 1500 A was observed. Geometric disk albedos, averaged over 50 A, were determined from 1500 A to 1700 A. Measurements of the ring reflectivity longward of 1650 A are compatible with H2O frost but not NH3 frost.

Weiser, H.↗

Crossed grid anode and its image partitioning

Measurements on an imaging crossed grid anode following a pair of microchannel plates indicate fast charge propagation via wire-to-wire capacitances, suggesting a temporal resolution of 100 ns. A figure of merit for partitioned systems has been suggested that provides an estimate of the position uncertainty of photoelectrons in the image plane of an anode. Solutions for two-, three-, and four-amplifier position algorithms are given, and basic system requirements are discussed.

Knapp, G.↗

Time-of-flight technique for particle identification at energies from 2 to 400 keV/nucleon

The time of flight technique for particle identification was extended to 2 keV/nucleon and the size of the start-time detector was reduced considerably by the use of carbon foils of few micrograms/cm square in thickness combined with microchannel plates for detecting secondary electrons. Time of flight telescopes incorporating this start-time device were used to measure the stopping power of a number of low energy heavy ions in thin carbon foils and the charge states of these ions emerging from such foils. Applications for the detection and identification of low energy interplanetary and magnetospheric particles are suggested.

Gloeckler, G.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗