Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopy analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

ECE 4396 (Final Report)

In the summer of 2025, I was fortunate enough intern at Sandia National Laboratories in Albuquerque, New Mexico. I was hired into the Southwest Analysis Laboratories for Semiconductor Advancement (SALSA) intern program. In this internship, I applied my knowledge and skills in electrical engineering to conduct hardware failure analysis. I utilized various failure analyze techniques involving the use of Infrared Thermography (IRT) and Laser Scanning Microscopy (LSM) to test different Application-Specific Integrated Circuits (ASIC) chips that are available in the public market.

42 ENGINEERING↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Towards Mitigating Electron Beam-Induced Damage in MOFs Using Low Dose Electron Microscopy for In-Situ Room-Temperature Measurements

Metal-Organic Frameworks (MOFs) have emerged as a versatile class of materials with applications in gas storage and separation, catalysis, and drug delivery [1]. Understanding their damage mechanisms in under various environmental conditions is crucial for optimizing performance and stability [2]. This study employs a combination of Length Structural Coherence (LSC) analysis in electron scattering and Electron Energy Loss Spectroscopy (EELS) to elucidate the damage mechanisms in two representative MOFs. MIL101(Fe), and MIL101(Cr). Here, the primary objective is to reveal structural and chemical changes that occur under electron beam irradiation in Scanning Transmission Electron Microscopy (STEM), both in the pristine state and during in-situ CO and CO 2 adsorption. By combining LSC in Radial Distribution Function (RDF) analysis with EELS, comprehensive insights into the nanoscale alterations are obtained and correlated to the electron dose rate.

dos Santos, Gabriel T. [Northwestern University, E↗

Development and Application of In Situ Nanocharacterization to Photocatalytic Materials for Solar Fuel Generation

Photocatalytic materials offer an attractive approach for converting solar energy into chemical energy but the performance of the current generation of materials is insufficient to make a technology viable. To address this deficiency, it is necessary to develop a fundamental atomic level understanding of the functioning of such materials so that strategies can be developed to improve performance. This project was undertaken to explore the fundamental structure and properties of photocatalytic materials using atomic resolution imaging and spectroscopy techniques available on advanced transmission electron microscopy. Specifically, there is a need to develop an understanding of how atomic structures/defects and nanoparticle configurations regulate electronic, optical, and catalytic properties to facilitate the design of next generation photocatalysts for solar fuel production. The work focused on fundamental materials information that can be gained from advanced transmission electron microscopy study on novel and existing photocatalytic systems with an emphasis on the hydrogen evolution reaction (HER). Throughout the project, new instrumentation and microscopy characterization tools were developed. Two focus areas were: developing in situ TEM methods and advanced electron energy-loss spectroscopic for nanoscale analysis of catalysts. The work spanned a period of 12 years and for convenience, the report is divided into four phases, approximately corresponding to the four funding periods of the program. Most of the significant results are reported in archival journal publications.

36 MATERIALS SCIENCE↗

Probing the role of local tunnel variations in early-stage lithiation of α-MnO₂ nanowires via in situ TEM

Understanding lithium-ion transport in tunnel-structured manganese oxides is essential for designing high-performance lithium-ion battery electrode materials. Here, we elucidate the early-stage lithiation mechanism of potassium-stabilized α-MnO 2 nanowires using in situ transmission electron microscopy (TEM) coupled with electron energy-loss spectroscopy (EELS), high-resolution TEM (HRTEM), and geometric phase analysis (GPA). Real-time TEM imaging reveals clear volume expansion at the reaction front, while EELS analysis uncovers lithium-ion diffusion far beyond this region, where no visible expansion is observed, indicating fast, defect-assisted transport. GPA and HRTEM analyses show that localized tensile and compressive strain fields, originating from pre-existing local tunnel structural variations, persist after lithiation. The tensile-strained regions enable lithium-ion insertion with minimal lattice distortion, offering additional free volume that facilitates rapid lithium-ion accommodation ahead of the structural transformation. Our results demonstrate a local tunnel variation-mediated fast diffusion pathway that precedes bulk reaction, underscoring the critical role of local strain in enabling early-stage lithium transport. Given the structural versatility of MnO 2 and its ability to accommodate diverse atomic arrangements beyond the well-known tunnel phases (β-, γ-, δ-, λ-, R-phases), our findings highlight the importance of understanding and engineering local structural environments. This work provides fundamental insights into the interplay between defects, strain, and ion dynamics, and presents defect engineering as a promising approach to enhance both rate performance and structural stability in manganese-based cathodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atom Identification in Bilayer Moiré Materials with Gomb-Net

Moiré patterns in van der Waals bilayer materials complicate the analysis of atomic-resolution images, hindering the atomic-scale insight typically attainable with scanning transmission electron microscopy. Here, we report a method to detect the positions and identities of atoms in each of the individual layers that compose twisted bilayer heterostructures. We developed a deep learning model, Gomb-Net, which identifies the coordinates and atomic species in each layer, deconvoluting the moiré pattern. This enables layer-specific mapping of atomic positions and dopant distributions, unlike other commonly used segmentation models which struggle with moiré-induced complexity. Using this approach, we explored the Se atom substitutional site distribution in a twisted fractional Janus WS 2 -WS 2(1–x) Se 2x heterostructure and found that layer-specific implantation sites are unaffected by the moiré pattern’s local energetic or electronic modulation. In conclusion, this advancement enables atom identification within material regimes where it was not possible before, opening new insights into previously inaccessible material physics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties of different LLM-105 preparations

LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide) has been prepared at several different size quantities (~10–70 Kg) and not subjected to further purification, such as recrystallization. Chemical and physical properties were compared—small-scale safety testing (impact, friction, ESD), thermal (chemical reactivity, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), one-dimensional time-to-explosion (ODTX)), morphological (particle-size distribution (PSD), scanning electron microscopy (SEM), powder x-ray diffraction (PXRD), skeletal density). Each preparation had similar properties to the other preparations except for PSD and PXRD. For PSD, all preparations exhibited a mono-modal distribution with a variation in median values from ~ 40 μm to over 80 μm. All PXRD values indicated the same morphology with minor variations in crystal orientations. Possible polymorphism was also observed in a few cases. SEM images and PXRD indicate all preparations to be diamond-type and X-type crystals with some twinning. Impact, friction, and ESD and thermal sensitivities values are consistent with these type of crystal habits as seen in vast literature studies.

Explosive characterization↗

Cryo-EM sample preparation for high-resolution structure studies

High-resolution structures of biomolecules can be obtained using single-particle cryo-electron microscopy (SPA cryo-EM), and the rapidly growing number of structures solved by this method is encouraging more researchers to utilize this technique. As with other structural biology methods, sample preparation for an SPA cryo-EM data collection requires some expertise and an understanding of the strengths and limitations of the technique in order to make sensible decisions in the sample-preparation process. Here, in this article, common strategies and pitfalls are described and practical advice is given to increase the chances of success when starting an SPA cryo-EM project.

36 MATERIALS SCIENCE↗

Oxygen Reduction on Platinum-Nickel and Platinum-Cobalt Alloy Based Catalysts for High Temperature Proton Exchange Membrane Fuel Cells

Catalyst layers, with commercial PtNi/TKK (TECNiE52; platinum 46.5 wt%), PtCo/TKK (TEC36E52; platinum 45.8 wt%) catalysts, and an in-house catalyst PtNi-NC (platinum 38.4 wt%), synthesised using acoustic mixer and a tube furnace, are prepared using three different ionomers: 20 wt% Nafion®, 60 wt% polytetrafluoroethylene (PTFE), and an in-house 5 wt% ionomer (‘Ionomer X’). These inks are bar-coated onto carbon paper gas diffusion layers (GDLs), which are cut into 3 cm × 5 cm pieces. The coated layers are tested for oxygen reduction in a commercial gas diffusion electrode (GDE) test cell, FlexCell® (Gaskatel GmbH, Germany), using 85 wt% phosphoric acid at both room temperature and at 155°C. This study evaluates the polynorbornene (PNB)-based in-house ionomer performance as binder and in-house catalyst oxygen reduction reaction (ORR) activity in comparison to commercial products. The catalyst layers are characterised using X-ray diffraction (XRD) analysis, X-ray photoelectron spectroscopy (XPS), and high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM). Among the catalyst layers prepared with PTFE ionomer and tested at 155°C, the in-house catalyst demonstrates the highest ORR activity. Ionomer X proves to be a good candidate to be used as a per- and polyfluoroalkyl-free binder for high-temperature (HT) proton exchange membrane fuel cell (PEMFC) applications.

85 wt% phosphoric acid↗

Measuring 3D Profilometry of SAVY-4000 Nuclear Material Storage Containers: Novacam TubeInspect Capabilities Report

The SAVY-4000 container series is a general-purpose interim storage container for nuclear materials, developed and maintained by Los Alamos National Laboratory (LANL). It is the first vented, general-use nuclear material container to be demonstrated as meeting the requirements outlined in DOE M 441.1-1, the Nuclear Material Packaging Manual. Due to the challenging radiation, thermal, and corrosive storage conditions that the SAVY containers must endure, continuous surveillance techniques are employed to ensure the containers meet all safety standards and specifications. These inspections are typically performed by human operators, who check for issues such as corrosion, O-ring deterioration, corrosion, filter integrity, and potential manufacturing defects. However, human inspections alone are not sufficient, and automated inspection technologies, such as the ATIS system, as well as other automated systems are also utilized. The MicroCam TubeInspect, developed by Novacam Technologies Inc., is designed to address the challenges of understanding how manufacturing variations in the SAVY-4000 container series may affect performance. It is a 3D profilometry measurement system that enables detailed analysis of surface features, including defects, surface roughness, and manufacturing variations. This advanced tool significantly enhances rapid surveillance techniques for both pristine and used containers. In this study, container properties such as surface roughness, thickness, and geometric attributes like circularity are measured for SAVY-4000 containers. Artificially corroded or dented containers are examined to demonstrate the MicroCam's ability to quantify defects. A sensitivity analysis is also conducted, comparing the MicroCam results to those obtained using more precise instruments such as confocal microscopy. This comparison aims to provide valuable insights into container quality, durability, and potential improvements in manufacturing processes.

42 ENGINEERING↗

Illuminating the Material World: Autonomous Microscopy to Understand Order, Disorder, and Everything In Between

Artificial intelligence (AI) holds immense promise for revolutionizing microscopy, yet its widespread adoption has been hindered by challenges ranging from user inexperience to limited model transferability and difficulties in operationalizing machine learning. This presentation showcases our approach to developing practical autonomy for materials discovery, aiming to accelerate the integration of AI into everyday microscopy workflows. As shown in Fig. 1, I will focus on three key areas: understanding order-disorder transitions, quantifying point defects, and achieving truly device-scale microscopy. First, I will demonstrate the power of multi-modal knowledge graphs for integrating diverse microscopy data. By combining imaging, spectroscopy, and diffraction data, these graphs provide a holistic view of material behavior, capturing the intricate relationships between different modalities [1,2]. I will present a case study on how these models illuminate the structural and chemical changes associated with irradiation in oxide thin films, revealing critical insights for designing materials for extreme environments like spaceflight and nuclear energy. Specifically, I will show how multi-modal analysis clarifies the evolution of order-disorder transitions under irradiation, a key factor influencing material performance in these applications. Next, I will address the challenge of quantifying point defects in 2D materials. We demonstrate the application of computer vision and transfer learning to accurately identify and classify various defect types, such as vacancies and substitutional atoms, and to quantify their concentrations. This information is crucial for understanding and tailoring the properties of 2D materials for applications in electronics, optoelectronics, and catalysis. For example, I will show how our models can characterize the topological distribution of point defects in MXene transition metal carbides, providing valuable insights for optimizing their performance in energy storage and separation science. Finally, I will discuss our progress toward autonomous device-scale microscopy [3,4]. We are fundamentally redesigning electron microscopes around the principles of machine reasoning, enabling automation beyond basic tasks like sample navigation and data acquisition to include sophisticated experimental design. This approach paves the way for truly reproducible and massively scaled analysis campaigns. I will emphasize the importance of autonomous microscopy platforms for high-throughput materials discovery and characterization, facilitating the rapid screening of materials for a broad range of applications and accelerating the development of next-generation technologies.

36 MATERIALS SCIENCE↗

Nanometer Resolution Structure‐Emission Correlation of Individual Quantum Emitters via Enhanced Cathodoluminescence in Twisted Hexagonal Boron Nitride

Understanding the atomic structure of quantum emitters, often originating from point defects or impuritie, is essential for designing and optimizing materials for quantum technologies such as quantum computing, communication, and sensing. Despite the availability of atomic-resolution scanning transmission electron microscopy and nanoscale cathodoluminescence microscopy, experimentally determining the atomic structure of individual emitters is challenging due to the conflicting needs for thick samples to generate strong cathodoluminescence signals and thin samples for structural analysis. To overcome this challenge, significantly enhanced cathodoluminescence at twisted interfaces is leveraged to achieve sub-nanometer localization precision for the first time in mapping individual quantum emitters in carbon-implanted hexagonal boron nitride. This unprecedent spatial sensitivity, together with correlative electron energy loss spectroscopy quantitative scanning transmission electron microscopy imaging, and first principles density functional theory calculations, enables the identification of the atomic structure of the 440 nm blue emitter in hexagonal boron nitride as a substituted vertical carbon dimer. Building on the atomic structure insights, nanoscale spatially precise creation of blue emitters is demonstrated by electron beam irradiation of carbon-coated hexagonal boron nitride. This advancement in correlating atomic structures with optical properties lays the foundation for a deeper understanding and precise engineering of quantum emitters, significantly advancing the development of cutting-edge quantum information technologies.

2D material↗

Correlated 4D-STEM and EDS for the classification of fine Beta-precipitates in aluminum alloy AA 6063-T6

Tuning the properties of aluminum alloys AA 6063-T6 involves artificial aging to induce precipitate formation, particularly β’’ and β’ phases. Previous characterization challenges due to their similar appearance are addressed here by correlating 4D scanning transmission electron microscopy (4DSTEM) and energy-dispersive spectroscopy (EDS) mapping. This approach allows us to analyze the structure and composition of precipitates individually, overcoming limitations of conventional imaging and structural analysis techniques when the precipitates appear simultaneously, as is often the case. We present detailed characterizations of needle-shaped Beta precipitates, revealing distinct diffraction patterns (DPs) and compositional differences. The method's applicability extends beyond aluminum alloys, offering a promising strategy for complex composite material characterization with multimodal scanning transmission electron microscopy (STEM) techniques.

36 MATERIALS SCIENCE↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Electrocatalytic benchmarking of ruthenium-based bimetallic anodes for the electrocatalytic oxidation of biomass-derived wastewater

In this paper, we report on the synthesis, characterization, and use of ruthenium oxide (RuO 2 ) doped with a secondary metal (M2) to enhance electrochemical activity and stability for the electrocatalytic oxidation (ECO) of biomass-derived wastewaters. We used different electrochemical methods such as cyclic voltammetry (CV), electrochemical surface area (ECSA), and Tafel analysis as well as physical characterization such as grazing incidence X-ray diffraction, X-ray photoelectron spectroscopy, and scanning electron microscopy to understand how the introduction of M2 affects electrochemical performance. Our results show that including an M2 improves the ECO performance regardless of the composition of the electrolyte. Specifically, we saw increase in ECSA, which could be due to enhanced charge transfer for the pH ranges evaluated. Furthermore, the introduction of organic compounds in wastewater generated during the hydrothermal liquefaction of food waste affected the ECO performance differently, depending on M2, the electrolyte composition, and anodic half-cell potential, highlighting the need to properly control the reaction conditions when testing and characterizing the electrocatalysts under different reaction regimes. We developed an in situ electrocatalytic benchmarking protocol, Boruah – Lopez-Ruiz – Strange (BLoRS), to quickly assess if the presence of M2 improves the ECO performance; thus, saving time and resources in ex situ characterization, testing, and product analysis. This foundational work provides the basis for characterization and benchmarking of electrodes of the ECO of organic compounds.

Electrocatalysis↗

Enhancing low-temperature sintering in the MgO-LiF system: Mechanistic insights

In the present article, we provide compelling evidence that minor (1 wt%) additions of micron and nanometre-sized LiF particles in MgO decompose leading to free Li diffusing into MgO surfaces enhancing vacancy production during direct current sintering. The addition of nanometre-sized LiF particles leads to a > 500 °C reduction in the sintering temperature and over 99 % theoretical density of final consolidated compacts. Correlating differential scanning calorimetry with in-situ x-ray diffraction, together with Schottky calculations, post sintering electron microscopy and laser induced breakdown spectroscopy, we uncover critical insights into this impressive reduction in sintering temperature. Our quantitative analysis reveals that MgO and LiF interact at low temperatures with the diffusion of Li into the surface of MgO particles due to the intrinsic structural disorder of the LiF and MgO crystallites. Nanometre-sized LiF particles were found to react the most at low temperatures due to their increased structural disorder. Our multimodal characterization points to a Li-promoted densification and sintering mechanism. This impressive reduction in sintering temperature can be harnessed to promote low-temperature fabrication of MgO-based composites for technological applications.

36 MATERIALS SCIENCE↗

Quantitative Imaging of Cobalt Phthalocyanine Distribution on Carbon Nanotubes: A Deep Learning Approach to Catalyst Characterization

Electrochemical reduction of carbon dioxide (CO 2 ) offers a pathway to valuable products, with catalysts playing a crucial role. This study investigates the distribution of cobalt tetraaminophthalocyanine (CoPc-NH 2 ) immobilized on carbon nanotubes (CNTs), utilizing high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) to characterize CoPc-NH 2 distribution. A challenge in the quantitative HAADF-STEM analysis is the introduction of bias from manual Co atom identification. To address this, we developed and trained a convolutional neural network (CNN) using a data set generated from images of CoPc-NH 2 /CNT samples with varying Co loadings. The CNN, implemented in TensorFlow and Keras, facilitated Co atom detections. Analysis of the CNN-generated data confirmed a correlation between Co loading and surface density, consistent with findings from UV–vis spectroscopy. Furthermore, the application of Ripley’s L(d) function highlighted the presence of slight Co atom clustering. Furthermore, this work demonstrates the utility of the combined HAADF-STEM and CNN approach for providing spatially resolved information about catalyst distribution on nonplanar supports, revealing structural details that are typically lost through other characterization methods.

HAADF-STEM↗