Search NASA⌕ Search

SEARCH · Search NASA

Results for “monitored quantum systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Comparison and validation of acoustic response models for wind noise reduction pipe arrays

The detection capability of the infrasound component of the International Monitoring System (IMS) is tightly linked to the performance of its wind noise reduction systems. The wind noise reduction solution implemented at all IMS infrasound measurement systems consists of a spatial distribution of air inlets connected to the infrasound sensor through a network of pipes. This system, usually referred to as “pipe array,” has proven its efficiency in operational conditions. The objective of this paper is to present the results of the comparison and validation of three distinct acoustic response models for pipe arrays. The characteristics of the models and the results obtained for a defined set of pipe array configurations are described. A field experiment using a newly developed infrasound generator, dedicated to the validation of these models, is then presented. The comparison between the modeled and empirical acoustic responses shows that two of the three models can be confidently used to estimate pipe array acoustic responses. Lastly, this study paves the way to the deconvolution of IMS infrasound data from pipe array responses and to the optimization of pipe array design to IMS applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA Tech Briefs, January 2005

Topics covered include: Fiber-Optic Sensor Would Monitor Growth of Polymer Film; Sensors for Pointing Moving Instruments Toward Each Other; Pd/CeO2/SiC Chemical Sensors; Microparticle Flow Sensor; Scattering-Type Surface-Plasmon-Resonance Biosensors; Diode-Laser-Based Spectrometer for Sensing Gases; Improved Cathode Structure for a Direct Methanol Fuel Cell; X-Band, 17-Watt Solid-State Power Amplifier; Improved Anode for a Direct Methanol Fuel Cell; Tools for Designing and Analyzing Structures; Interactive Display of Scenes with Annotations; Solving Common Mathematical Problems; Tools for Basic Statistical Analysis; Program Calculates Forces in Bolted Structural Joints; Integrated Structural Analysis and Test Program; Molybdate Coatings for Protecting Aluminum Against Corrosion; Synthesizing Diamond from Liquid Feedstock; Modifying Silicates for Better Dispersion in Nanocomposites; Powder-Collection System for Ultrasonic/Sonic Drill/Corer; Semiautomated, Reproducible Batch Processing of Soy; Hydrogen Peroxide Enhances Removal of NOx from Flue Gases; Subsurface Ice Probe; Real-Time Simulation of Aeroheating of the Hyper-X Airplane; Using Laser-Induced Incandescence To Measure Soot in Exhaust; Method of Real-Time Principal-Component Analysis; Insect-Inspired Flight Control for Unmanned Aerial Vehicles; Domain Compilation for Embedded Real-Time Planning; Semantic Metrics for Analysis of Software; Simulation of Laser Cooling and Trapping in Engineering Applications; Large Fluvial Fans and Exploration for Hydrocarbons; Doping-Induced Interband Gain in InAs/AlSb Quantum Wells; Development of Software for a Lidar-Altimeter Processor; Upgrading the Space Shuttle Caution and Warning System; and Fractal Reference Signals in Pulse-Width Modulation.

Source record↗

Interaction-Controlled Transport of an Ultracold Fermi Gas

We explore the transport properties of an interacting Fermi gas in a three-dimensional optical lattice. The center of mass dynamics of the atoms after a sudden displacement of the trap minimum is monitored for different interaction strengths and lattice fillings. With increasingly strong attractive interactions the weakly damped oscillation, observed for the noninteracting case, turns into a slow relaxational drift. Tuning the interaction strength during the evolution allows us to dynamically control the transport behavior. Strong attraction between the atoms leads to the formation of local pairs with a reduced tunneling rate. The interpretation in terms of pair formation is supported by a measurement of the number of doubly occupied lattice sites. This quantity also allows us to determine the temperature of the noninteracting gas in the lattice to be as low as (27{+-}2)% of the Fermi temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of nutritional status on metabolic rate, exercise and recovery in a freshwater fish

The influence of feeding on swimming performance and exercise recovery in fish is poorly understood. Examining swimming behavior and physiological status following periods of feeding and fasting is important because wild fish often face periods of starvation. In the current study, researchers force fed and fasted groups of largemouth bass (Micropterus salmoides) of similar sizes for a period of 16 days. Following this feeding and fasting period, fish were exercised for 60 s and monitored for swimming performance and physiological recovery. Resting metabolic rates were also determined. Fasted fish lost an average of 16 g (nearly 12%) of body mass, while force fed fish maintained body mass. Force fed fish swam 28% further and required nearly 14 s longer to tire during exercise. However, only some physiological conditions differed between feeding groups. Resting muscle glycogen concentrations was twofold greater in force fed fish, at rest and throughout recovery, although it decreased in both feeding treatments following exercise. Liver mass was nearly three times greater in force fed fish, and fasted fish had an average of 65% more cortisol throughout recovery. Similar recovery rates of most physiological responses were observed despite force fed fish having a metabolic rate 75% greater than fasted fish. Results are discussed as they relate to largemouth bass starvation in wild systems and how these physiological differences might be important in an evolutionary context.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Facile and high spatial resolution ratio-metric luminescence thermal mapping in microfluidics by near infrared excited upconversion nanoparticles

A local area temperature monitor is important for precise control of chemical and biological processes in microfluidics. In this work, we developed a facile method to realize micron spatial resolution of temperature mapping in a microfluidic channel quickly and cost effectively. Based on the temperature dependent fluorescence emission of NaYF{sub 4}:Yb{sup 3+}, Er{sup 3+} upconversion nanoparticles (UCNPs) under near-infrared irradiation, ratio-metric imaging of UCNPs doped polydimethylsiloxane can map detailed temperature distribution in the channel. Unlike some reported strategies that utilize temperature sensitive organic dye (such as Rhodamine) to achieve thermal sensing, our method is highly chemically inert and physically stable without any performance degradation in long term operation. Moreover, this method can be easily scaled up or down, since the spatial and temperature resolution is determined by an optical imaging system. Our method supplied a simple and efficient solution for temperature mapping on a heterogeneous surface where usage of an infrared thermal camera was limited.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimum current principle and variational method in theory of space charge limited flow

In spirit of the principle of least action, which means that when a perturbation is applied to a physical system, its reaction is such that it modifies its state to “agree” with the perturbation by “minimal” change of its initial state. In particular, the electron field emission should produce the minimum current consistent with boundary conditions. It can be found theoretically by solving corresponding equations using different techniques. We apply here the variational method for the current calculation, which can be quite effective even when involving a short set of trial functions. The approach to a better result can be monitored by the total current that should decrease when we on the right track. Here, we present only an illustration for simple geometries of devices with the electron flow. The development of these methods can be useful when the emitter and/or anode shapes make difficult the use of standard approaches. Though direct numerical calculations including particle-in-cell technique are very effective, but theoretical calculations can provide an important insight for understanding general features of flow formation and even sometimes be realized by simpler routines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Doppler sensor employing a single fan-shaped interference fringe system for distance and shape measurement of laterally moving objects

For monitoring the position and shape of fast moving and, especially, rotating objects such as turbo machine rotors, contactless and compact sensors with a high measurement rate as well as high precision are required. We present for the first time, to the best of our knowledge, a novel laser Doppler sensor employing a single fan-shaped interference fringe system, which allows measuring for the position and shape of fast moving solid bodies with known tangential velocity. It is shown theoretically as well as experimentally that this sensor offers concurrently high position resolution and high temporal resolution in contrast to conventional measurement techniques, since its measurement uncertainty is, in principle, independent of the object velocity. Moreover, it can be built very compact, because it features low complexity. To prove its operational capability and its potential for practical applications, radial and axial shape measurements of rotating bodies are demonstrated in comparison with triangulation. An average position resolution of about 2 {mu}m could be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent operations of the camera over 10 days is tested. Results: The PET camera maintains a temperature of 18.00 ± 0.05 °C over the course of 12 h while the ambient temperature varied 0.61 °C, from 22.83 to 23.44 °C. The 511 keV photopeak energy resolution over a period of 8.66 h is measured to be 11.3% FWHM with a maximum photopeak fluctuation of 4 keV. Between measurements of PSAPD gain separated by at least 2 day, the maximum photopeak shift was 6 keV. Conclusions: The proposed thermal regulation scheme for tightly packed silicon photodetectors provides for stable operation of the constructed subsection of a PET camera over long durations of time. The energy resolution of the system is not degraded despite shifts in ambient temperature and photodetector heat generation. The thermal regulation scheme also provides a consistent operating environment between separate runs of the camera over different days. Inter-run consistency allows for reuse of system calibration parameters from study to study, reducing the time required to calibrate the system and hence to obtain a reconstructed image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor-Equipped Unmanned Surface Vehicle for High-Resolution Mapping of Water Quality in Low- to Mid-Order Streams

Longitudinal profiling of water quality via the deployment of sensors from watercraft has advanced the understanding of spatial patterns in large rivers and lakes; however, a similar approach in low- to mid-order streams is lacking. To fill this gap, we developed an unmanned surface vehicle (USV)-water quality measurement platform (the “AquaBOT”). The components of the AquaBOT included a nitrate sensor, multiparameter sonde (temperature, conductivity, turbidity, dissolved oxygen, chlorophyll), quantum sensor, and global positioning system (GPS) mounted to a small pontoon-style USV. The AquaBOT was tested in four streams and rivers in Iowa and Tennessee. All measured water quality parameters varied longitudinally, and greater ranges were generally observed along the low-order, agriculturally influenced streams in Iowa. Nitrate, in particular, was spatially heterogeneous. For example, during one run in early June, concentrations ranged from 10.5 to 12.5 mg N L –1 along a 2.3 km reach and hotspots were observed directly downstream of some tile drains. The spatial resolution of AquaBOT data collected in June was 10× higher than grab sampling data, and measurements were collected in less time and at a comparable cost. Here, the AquaBOT can complement existing measurement approaches and will lead to advancements in understanding the processes driving water quality along the stream-to-river continuum.

47 OTHER INSTRUMENTATION↗

Development of long pulse RF heating and current drive for H-mode scenarios with metallic walls in WEST

The longstanding expertise of the Tore Supra team in long pulse heating and current drive with radiofrequency (RF) systems will now be exploited in the WEST device (tungsten-W Environment in Steady-state Tokamak) [1]. WEST will allow an integrated long pulse tokamak programme for testing W-divertor components at ITER-relevant heat flux (10-20 MW/m{sup 2}), while treating crucial aspects for ITER-operation, such as avoidance of W-accumulation in long discharges, monitoring and control of heat fluxes on the metallic plasma facing components (PFCs) and coupling of RF waves in H-mode plasmas. Scenario modelling using the METIS-code shows that ITER-relevant heat fluxes are compatible with the sustainment of long pulse H-mode discharges, at high power (up to 15 MW / 30 s at I{sub P} = 0.8 MA) or high fluence (up to 10 MW / 1000 s at I{sub P} = 0.6 MA) [2], all based on RF heating and current drive using Ion Cyclotron Resonance Heating (ICRH) and Lower Hybrid Current Drive (LHCD). This paper gives a description of the ICRH and LHCD systems in WEST, together with the modelling of the power deposition of the RF waves in the WEST-scenarios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrazine Detection with a Tunable Diode Laser Spectrometer

Several instruments have been developed to measure low concentrations of hydrazine but none completely meet the sensitivity requirements while satisfying additional criteria such as quick response, stable calibration, interference free operation, online operation, reasonable cost, etc. A brief review is presented of the current technology including the electrochemical cell, the ion mobility spectrometer, the mass spectrometer, and the gas chromatograph. A review of the advantages and disadvantages of these instruments are presented here. The review also includes commercially unavailable technology such as the electronic nose and the Tunable Diode Laser (TDL) IR Spectrometer. It was found that the TDL could meet the majority of these criteria including fast response, minimum maintenance, portability, and reasonable cost. An experiment was conducted to demonstrate the feasibility of such a system using an existing (non-portable) instrument. A lead-salt tunable diode laser, cooled to 85 degrees Kelvin was used to record direct absorption and second-derivative spectra of Hydrazine at several pressures to study the sensitivity to low levels of Hydrazine. Spectra of NH3 and CO2 were used for wavelength identification of the scanned region. With a pathlength of 80 m, detection sensitivities of about 1 ppb were achieved for hydrazine in dry nitrogen at a cell pressure of 100 mbar. For spectroscopic detection of Hydrazine, spectral regions including strong Ammonia or Carbon Dioxide lines must be avoided. Strong Hydrazine absorption features were identified at 940/cm showing minimal contribution from Ammonia interferences as suitable candidates for Hydrazine gas detection. For the studies reported here, the particular laser diode could only cover the narrow regions near 962/cm and 965/cm where strong Ammonia interferences were expected. However, the high resolution (0.001/cm) of the TDL spectrometer allowed individual lines of Hydrazine to be identified away from interferences from either Ammonia or Carbon Dioxide, especially at lower pressures. A Hydrazine line was identified at 961.75/cm which was free from Ammonia absorption and would be suitable to monitor hydrazine levels. This paper also shows data on the degradation of the detectivity of Hydrazine with increasing pressure. Several design options for a portable unit are presented, including designs with near IR and Quantum Cascade laser components which do not require liquid nitrogen cooling.

Houseman, John↗

Features of Construction of the Fluorescent Microscope for the Study of Epithelial-Mesenchymal Transition of Cells in Vitro

An optical luminescent microscope has been developed to monitor the behavior of tumor cells that were modified by GFP and RFP fluorescent proteins and to monitor the formation of metastases in biochips. Images of cells in the light of GFP and RFP fluorescence proteins, as well as in the photography mode, are recorded in the microscope by an noncooled CMOS matrix at the excitation of luminescence by blue and green LEDs and illumination of cells with white LEDs, respectively. The obtained fluorescent images and photos in white light are recorded by the matrix in the same coordinate system and do not require additional processing for combination. The power of irradiation of cells with LEDs does not exceed 50 μW/mm{sup 2} at an exposure time of 1 s, which is an order of magnitude lower than the radiation power causing photodestruction and phototoxicity of cells during long-term studies. Relative parameters of the optical channel of the luminescent microscope have been introduced that allow comparing the sensitivity of the recording system and the minimum power level of the radiation that excites luminescence for optical elements with different spectral characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D model generation using an airborne swarm

Using an artificial kinematic field to provide co-ordination between multiple inspection UAVs, the authors herein demonstrate full 3D modelling capability based on a photogrammetric system. The operation of the system is demonstrated by generating a full 3D surface model of an intermediate level nuclear waste storage drum. Such drums require periodic inspection to ensure that drum distortion or corrosion is carefully monitored. Performing this inspection with multiple airborne platforms enables rapid inspection of structures that are inaccessible to on-surface remote vehicles and are in human-hazardous environments. A three-dimensional surface-meshed model of the target can then be constructed in post-processing through photogrammetry analysis of the visual inspection data. The inspection environment uses a tracking system to precisely monitor the position of each aerial vehicle within the enclosure. The vehicles used are commercially available Parrot AR. Drone quadcopters, controlled through a computer interface connected over an IEEE 802.11n (WiFi) network, implementing a distributed controller for each vehicle. This enables the autonomous and distributed elements of the control scheme to be retained, while alleviating the vehicles of the control algorithm’s computational load. The control scheme relies on a kinematic field defined with the target at its centre. This field defines the trajectory for all the drones in the volume relative to the central target, enabling the drones to circle the target at a set radius while avoiding drone collisions. This function enables complete coverage along the height of the object, which is assured by transitioning to another inspection band only after completing circumferential coverage. Using a swarm of vehicles, the time until complete coverage can be significantly reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 34.5 kPa, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.114 m{sup 3}/hr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis and properties of ZnTe and Eu{sup 3+} ion co-doped glass nanocomposites

In this study, ZnTe (II-VI) semiconductor and Eu{sup +3}-ion co-doped borosilicate glass has been prepared in the SiO{sub 2}-K{sub 2}O-CaO-BaO-B{sub 2}O{sub 3} glass system followed by controlled heat-treatment to produce glass nanocomposites. Glass transition temperature and crystallization peak temperature have been evaluated using DSC analysis. Dilatometric studies were carried out to evaluate thermal expansion co-efficient, glass transition temperature, and dilatometric softening temperature and found to be 10.7 × 10{sup −6}/K, 580° C and 628° C, respectively. TEM micrographs demonstrate formation of nano sized crystallites of less than 50 nm. The ZnTe crystal formation also established through selected area electron diffraction (SAED) analysis and high resolution images obtained through TEM studies. With increasing heat treatment time, optical transmission cut-off wavelength (λ{sub cut-off}) shifted towards higher wavelength. Excitation spectra were recorded by monitoring emission at 613 nm corresponding to the {sup 5}D{sub 0} → {sup 7}F{sub 2} transition. An intense 394 nm excitation band corresponding to the {sup 7}F{sub 0} → {sup 5}L{sub 6} transition was observed. Emission spectra were then recorded by exciting the glass samples at 394 nm. When the glass is heat-treated for 30 min at 610° C, a 6-fold increase in the intensity of the red emission at 612 nm has been observed, which is attributed to the segregation of Eu{sup 3+} ions into the low phonon energy ZnTe crystallites and as the size of the nanocrystals is smaller than the size of the exciton, quantum confinement effect is visible. Further increase in heat-treatment duration led to decrease in luminescence intensity due to the growth of larger size crystals. {sup 5}D{sub 1} → {sup 7}F{sub 0} transition is visible only in the samples heat-treated for 30 min and 1 h, which is a characteristic of presence of Eu{sup 3+} ions in the low phonon energy ZnTe crystal sites. The micro hardness of the precursor glass and glass nanocomposites was evaluated; base glass shows hardness of 6.7 GPa and hardness of heat-treated glass nanocomposites has been found to decrease with increase in heat-treatment duration (5.5-5.3 GPa). However, mechanical properties are found to be suitable for device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Baylor University Campus-Wide Deep Dive

In January 2020, staff members from the Engagement and Performance Operations Center (EPOC) and the Lonestar Education And Research Network (LEARN) met with researchers and staff at Baylor University for the purpose of a Campus-Wide Deep Dive into research drivers. The goal of this meeting was to help characterize the requirements for five campus research use cases and to enable cyberinfrastructure support staff to better understand the needs of the researchers they support. Profiled scientific use cases included: - Experimental High Energy Physics (HEP) - Proton Computed Tomography (pCT) - Nutrition and Relation to Digestive Microbiome - Baylor University Core Research Facilities - Molecular Quantum-dot Cellular Automata (QCA), and Material Science of Quantum Computing - Modeling and Simulation of Low-Dimensional and Nano-Structured Materials - Computational Fluid Dynamics Material for this event included the written documentation from each of the research areas at Baylor University, documentation about the current state of technology support, and a write-up of the discussion that took place in person. The Case Studies highlighted the ongoing challenges that Baylor University has in supporting a cross-section of established and emerging research use cases. Each Case Study mentioned unique challenges which were summarized into common needs. These included: - Tradeoffs for network/software security, and usability of the resulting infrastructure. Better communication to set expectations and understand realities is required. - Computation use on campus is widespread and healthy. While no major problems were uncovered, upgrades to maintain current usage patterns and encourage growth will be required. - Storage is a critical need for enterprise use cases and research. In particular, a campus wide ‘storage architecture’ to support research use cases (e.g. instruments, data sharing) is required in the 2-5 year time window. - Instrumentation on campus is healthy and expanding. Technology must scale with this in the form of computation and storage. - Working with LEARN to upgrade network capacity (in multiples of 10G, or upgrades to 100G) will be required in the 1-3 year time frame. - Network monitoring and visibility will help to establish external science use cases. - Data sharing via portal systems is not currently a critical need, but growing in scope. EPOC can assist Baylor with options.

99 GENERAL AND MISCELLANEOUS↗

Fatigue of extracted lead zirconate titanate multilayer actuators under unipolar high field electric cycling

Testing of large prototype lead zirconate titanate (PZT) stacks presents substantial technical challenges to electronic testing systems, so an alternative approach that uses subunits extracted from prototypes has been pursued. Extracted 10-layer and 20-layer plate specimens were subjected to an electric cycle test under an electric field of 3.0/0.0 kV/mm, 100 Hz to 10{sup 8} cycles. The effects of measurement field level and stack size (number of PZT layers) on the fatigue responses of piezoelectric and dielectric coefficients were observed. On-line monitoring permitted examination of the fatigue response of the PZT stacks. The fatigue rate (based on on-line monitoring) and the fatigue index (based on the conductance spectrum from impedance measurement or small signal measurement) were developed to quantify the fatigue status of the PZT stacks. The controlling fatigue mechanism was analyzed against the fatigue observations. The data presented can serve as input to design optimization of PZT stacks and to operation optimization in critical applications, such as piezoelectric fuel injectors in heavy-duty diesel engines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗