Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Properties of the large- and small-scale flow patterns in and around AR 19824

A series of magnetograms spanning just over 5 days and covering about 4 x 5 arcmin has been used to trace the photospheric motions of 170 concentrations of magnetic flux tubes in and around the decaying active region 19824. A persistent large-scale flow pattern superposed on small-scale random motions of both polarities is noted whose overall pattern resembles the flow of a river around a sand bar, and whose long-term evolution suggests a persistence of several months. The observed motions of concentrations of flux tubes are corrected for the large-scale flow in order to study their random motions.

Schrijver, C. J.↗

Potential benefits of dosimetric VMAT tracking verified with 3D film measurements

Purpose: To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. Methods: A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3 films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Results: Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution’s position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously irradiated prostate. A drawback of both the geometric and dosimetric tracking was a reduced MLC blocking caused by the rotational component of the MLC aperture corrections. Because of the used CTV to PTV margins and the high doses in the considered fractionation schemes, the TCP differed less than 0.02 from the planned value for all targets and all correction methods. The rectal NTCP constraints, however, could not be realized using any of these methods. Conclusions: The geometric and dosimetric tracking use only a limited input, but they deposit the dose distribution with higher geometric accuracy than the clinical practice. The latter case has boost dose errors up to 10%. The increased accuracy has a modest impact [Δ(NT)CP < 0.02] because of the applied margins and the high dose levels used. To allow further margin reduction tracking methods are vital. The proposed methodology could further be improved by implementing a rotational correction using collimator rotations.

60 APPLIED LIFE SCIENCES↗

The Pantheon+ Analysis: Evaluating Peculiar Velocity Corrections in Cosmological Analyses with Nearby Type Ia Supernovae

Separating the components of redshift due to expansion and peculiar motion in the nearby universe (z < 0.1) is critical for using Type Ia Supernovae (SNe Ia) to measure the Hubble constant (H 0 ) and the equation-of-state parameter of dark energy (w). Here, we study the two dominant "motions" contributing to nearby peculiar velocities: large-scale, coherent-flow (CF) motions and small-scale motions due to gravitationally associated galaxies deemed to be in a galaxy group. We use a set of 584 low-z SNe from the Pantheon+ sample, and evaluate the efficacy of corrections to these motions by measuring the improvement of SN distance residuals. We study multiple methods for modeling the large and small-scale motions and show that, while group assignments and CF corrections individually contribute to small improvements in Hubble residual scatter, the greatest improvement comes from the combination of the two (relative standard deviation of the Hubble residuals, Rel. SD, improves from 0.167 to 0.157 mag). We find the optimal flow corrections derived from various local density maps significantly reduce Hubble residuals while raising H 0 by ~0.4 km s -1 Mpc -1 as compared to using CMB redshifts, disfavoring the hypothesis that unrecognized local structure could resolve the Hubble tension. We estimate that the systematic uncertainties in cosmological parameters after optimally correcting redshifts are 0.06–0.11 km s -1 Mpc -1 in H 0 and 0.02–0.03 in w which are smaller than the statistical uncertainties for these measurements: 1.5 km s -1 Mpc -1 for H 0 and 0.04 for w.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization-based mesh correction with volume and convexity constraints

Here, we consider the problem of finding a mesh such that 1) it is the closest, with respect to a suitable metric, to a given source mesh having the same connectivity, and 2) the volumes of its cells match a set of prescribed positive values that are not necessarily equal to the cell volumes in the source mesh. Also, this volume correction problem arises in important simulation contexts, such as satisfying a discrete geometric conservation law and solving transport equations by incremental remapping or similar semi-Lagrangian transport schemes. In this paper we formulate volume correction as a constrained optimization problem in which the distance to the source mesh defines an optimization objective, while the prescribed cell volumes, mesh validity and/or cell convexity specify the constraints. We solve this problem numerically using a sequential quadratic programming (SQP) method whose performance scales with the mesh size. To achieve scalable performance we develop a specialized multigrid-based preconditioner for optimality systems that arise in the application of the SQP method to the volume correction problem. Numerical examples illustrate the importance of volume correction, and showcase the accuracy, robustness and scalability of our approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

4D in-beam positron emission tomography for verification of motion-compensated ion beam therapy

Purpose: Clinically safe and effective treatment of intrafractionally moving targets with scanned ion beams requires dedicated delivery techniques such as beam tracking. Apart from treatment delivery, also appropriate methods for validation of the actual tumor irradiation are highly desirable. In this contribution the feasibility of four-dimensionally (space and time) resolved, motion-compensated in-beam positron emission tomography (4DibPET) was addressed in experimental studies with scanned carbon ion beams. Methods: A polymethyl methracrylate block sinusoidally moving left-right in beam's eye view was used as target. Radiological depth changes were introduced by placing a stationary ramp-shaped absorber proximal of the moving target. Treatment delivery was compensated for motion by beam tracking. Time-resolved, motion-correlated in-beam PET data acquisition was performed during beam delivery with tracking the moving target and prolonged after beam delivery first with the activated target still in motion and, finally, with the target at rest. Motion-compensated 4DibPET imaging was implemented and the results were compared to a stationary reference irradiation of the same treatment field. Data were used to determine feasibility of 4DibPET but also to evaluate offline in comparison to in-beam PET acquisition. Results: 4D in-beam as well as offline PET imaging was found to be feasible and offers the possibility to verify the correct functioning of beam tracking. Motion compensation of the imaged {beta}{sup +}-activity distribution allows recovery of the volumetric extension of the delivered field for direct comparison with the reference stationary condition. Observed differences in terms of lateral field extension and penumbra in the direction of motion were typically less than 1 mm for both imaging strategies in comparison to the corresponding reference distributions. However, in-beam imaging retained a better spatial correlation of the measured activity with the delivered dose. Conclusions: 4DibPET is a feasible and promising method to validate treatment delivery of scanned ion beams to moving targets. Further investigations will focus on more complex geometries and treatment planning studies with clinical data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correction And Use Of Jitter In Television Images

Proposed system stabilizes jittering television image and/or measures jitter to extract information on motions of objects in image. Alternative version, system controls lateral motion on camera to generate stereoscopic views to measure distances to objects. In another version, motion of camera controlled to keep object in view. Heart of system is digital image-data processor called "jitter-miser", which includes frame buffer and logic circuits to correct for jitter in image. Signals from motion sensors on camera sent to logic circuits and processed into corrections for motion along and across line of sight.

Diner, Daniel B.↗

Internal motion and its pressure dependence in FeSiF6+6/H2O/.

Both wideline and pulsed NMR techniques were used to examine the internal motion in FeSiF6+6(H2O). Corrections of second moments for bulk paramagnetic effects were essential. At room temperature and pressure, the fluorine-fluorine contribution to the 19F second moment is 0.38 (plus or minus 0.06) G2, and indicates rapid orientation of the SiF6(--) group. Analysis of the second moment within the transition region allows calculation of an activation volume which is 2.4 (plus or minus 0.4) % of the molar volume. The application of pressure slows the internal motion such that the rigid lattice values of the 19F second moment are obtained above 50 kbar.

Vaughan, R. W.↗

Quantification of the Variability of Diaphragm Motion and Implications for Treatment Margin Construction

Purpose: To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. Methods and Materials: Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. Results: The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin{sup 4} function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. Conclusion: The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamics of a vertical flight in the stationary gravitational field of a celestial body: Post-newtonian corrections and gravitational redshift

The standard problem of a radial motion of test particles in the stationary gravitational field of a spherically symmetric celestial body is solved and is used to determine the time features of this motion. The problem is solved for the equations of motion of general relativity (GR), and the time features are obtained in the post-Newtonian approximation, with linear GR corrections proportional to r{sub g}/r and {beta}{sup 2} (in the solution being considered, they are of the same order of smallness) being taken rigorously into account. Total times obtained by integrating the time differentials along the trajectories of motion are considered as the time features in question. It is shown that, for any parameters of the motion, the proper time (which corresponds to watches comoving with a test particle) exceeds the time of watches at rest (watches at the surface of the celestial body being considered). The mass and the radius of the celestial body, as well as the initial velocity of the test particle, serve as arbitrary parameters of the motion. The time difference indicated above implies a leading role of the gravitational redshift, which decreases somewhat because of the opposite effect of the Doppler shift. The results are estimated quantitatively for the important (from the experimental point of view) case of vertical flights of rockets starting from the Earth's surface. In this case, the GR corrections, albeit being extremely small (a few microseconds for several hours of the flight), aremeasurable with atomic (quantum) watches.

79 ASTRONOMY AND ASTROPHYSICS↗

THE TRANSVERSE PECULIAR VELOCITY OF THE Q2237+0305 LENS GALAXY AND THE MEAN MASS OF ITS STARS

Using 11 years of OGLE V-band photometry of Q2237+0305, we measure the transverse velocity of the lens galaxy and the mean mass of its stars. We can do so because, for the first time, we fully include the random motions of the stars in the lens galaxy in the analysis of the light curves. In doing so, we are also able to correctly account for Earth's parallax motion and the rotation of the lens galaxy, further reducing systematic errors. We measure a lower limit on the transverse speed of the lens galaxy, v{sub t} > 338 km s{sup -1} (68% confidence) and find a preferred direction to the east. The mean stellar mass estimate, including a well-defined velocity prior, is 0.12 <= (M/M{sub sun}) <= 1.94 at 68% confidence, with a median of 0.52 M{sub sun}. We also show for the first time that analyzing subsets of a microlensing light curve, in this case the first and second halves of the OGLE V-band light curve, gives mutually consistent physical results.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-EF-304-03: 4D Monte Carlo Robustness Test for Proton Therapy

Purpose: Breathing motion and approximate dose calculation engines may increase proton range uncertainties. We address these two issues using a comprehensive 4D robustness evaluation tool based on an efficient Monte Carlo (MC) engine, which can simulate breathing with no significant increase in computation time. Methods: To assess the robustness of the treatment plan, multiple scenarios of uncertainties are simulated, taking into account the systematic and random setup errors, range uncertainties, and organ motion. Our fast MC dose engine, called MCsquare, implements optimized models on a massively-parallel computation architecture and allows us to accurately simulate a scenario in less than one minute. The deviations of the uncertainty scenarios are then reported on a DVH-band and compared to the nominal plan.The robustness evaluation tool is illustrated in a lung case by comparing three 60Gy treatment plans. First, a plan is optimized on a PTV obtained by extending the CTV with an 8mm margin, in order to take into account systematic geometrical uncertainties, like in our current practice in radiotherapy. No specific strategy is employed to correct for tumor and organ motions. The second plan involves a PTV generated from the ITV, which encompasses the tumor volume in all breathing phases. The last plan results from robust optimization performed on the ITV, with robustness parameters of 3% for tissue density and 8 mm for positioning errors. Results: The robustness test revealed that the first two plans could not properly cover the target in the presence of uncertainties. CTV-coverage (D95) in the three plans ranged respectively between 39.4–55.5Gy, 50.2–57.5Gy, and 55.1–58.6Gy. Conclusion: A realistic robustness verification tool based on a fast MC dose engine has been developed. This test is essential to assess the quality of proton therapy plan and very useful to study various planning strategies for mobile tumors. This work is partly funded by IBA (Louvain-la-Neuve, Belgium)

60 APPLIED LIFE SCIENCES↗

DARK AND LUMINOUS MATTER IN THINGS DWARF GALAXIES

We present mass models for the dark matter component of seven dwarf galaxies taken from 'The H I Nearby Galaxy Survey' (THINGS) and compare these with those taken from numerical {Lambda} cold dark matter ({Lambda}CDM) simulations. The THINGS high-resolution data significantly reduce observational uncertainties and thus allow us to derive accurate dark matter distributions in these systems. We here use the bulk velocity fields when deriving the rotation curves of the galaxies. Compared to other types of velocity fields, the bulk velocity field minimizes the effect of small-scale random motions more effectively and traces the underlying kinematics of a galaxy more properly. The 'Spitzer Infrared Nearby Galaxies Survey' 3.6 {mu}m and ancillary optical data are used for separating the baryons from their total matter content in the galaxies. The sample dwarf galaxies are found to be dark matter dominated over most radii. The relation between total baryonic (stars + gas) mass and maximum rotation velocity of the galaxies is roughly consistent with the baryonic Tully-Fisher relation calibrated from a larger sample of gas-dominated low-mass galaxies. We find discrepancies between the derived dark matter distributions of the galaxies and those of {Lambda}CDM simulations, even after corrections for non-circular motions have been applied. The observed solid body-like rotation curves of the galaxies rise too slowly to reflect the cusp-like dark matter distribution in cold dark matter halos. Instead, they are better described by core-like models such as pseudo-isothermal halo models dominated by a central constant-density core. The mean value of the logarithmic inner slopes of the mass density profiles is {alpha} = -0.29 {+-} 0.07. They are significantly different from the steep slope of {approx} - 1.0 inferred from previous dark-matter-only simulations, and are more consistent with shallower slopes found in recent {Lambda}CDM simulations of dwarf galaxies in which the effects of baryonic feedback processes are included.

79 ASTRONOMY AND ASTROPHYSICS↗

E-PVT: enhanced position-velocity-time scheduler for computer-controlled optical finishing with comprehensive considerations of dynamics constraints, continuity and efficiency

Deterministic computer-controlled optical finishing is an essential approach for achieving high-quality optical surfaces. Its determinism and convergence rely heavily on precise and smooth motion control to guide the machine tool over an optical surface to correct residual errors. One widely supported and smooth motion control model is position-velocity-time (PVT), which employs piecewise cubic polynomials to describe positions. Our prior research introduced a PVT-based velocity scheduling method, demonstrating sub-nanometer level convergence in ion beam figuring (IBF) processes. However, three challenges remained. Firstly, this method relies on quadratic programming, resulting in computational intensiveness for dense tool paths. Secondly, the dynamics constraints and velocity and acceleration continuities are not comprehensively considered, limiting the full potential of PVT-based control. Thirdly, no compensation mechanism existed when dynamics constraints are exceeded. In this study, in response to these challenges, we proposed the Enhanced PVT (E-PVT) method, reducing the time complexity from O ( n 3 ) to O ( n ) while fully addressing dynamics constraints and continuities. A novel compensation method utilizing particle swarm optimization was proposed to address situations where dynamics constraints might be exceeded while maintaining the overall processing efficiency. Validation through simulation and experimentation confirmed the improved performance of E-PVT.

36 MATERIALS SCIENCE↗

Searches for millisecond pulsations in low-mass X-ray binaries, 2

Coherent millisecond X-ray pulsations are expected from low-mass X-ray binaries (LMXBs), but remain undetected. Using the single-parameter Quadratic Coherence Recovery Technique (QCRT) to correct for unknown binary orbit motion, we have performed Fourier transform searches for coherent oscillations in all long, continuous segments of data obtained at 1 ms time resolution during Ginga observations of LMXB. We have searched the six known Z sources (GX 5-1, Cyg X-2, Sco X-1, GX 17+2, GX 340+0, and GX 349+2), seven of the 14 known atoll sources (GX 3+1. GX 9+1, GX 9+9, 1728-33. 1820-30, 1636-53 and 1608-52), the 'peculiar' source Cir X-1, and the high-mass binary Cyg X-3. We find no evidence for coherent pulsations in any of these sources, with 99% confidence limits on the pulsed fraction between 0.3% and 5.0% at frequencies below the Nyquist frequency of 512 Hz. A key assumption made in determining upper limits in previous searches is shown to be incorrect. We provide a recipe for correctly setting upper limits and detection thresholds. Finally we discuss and apply two strategies to improve sensitivity by utilizing multiple, independent, continuous segments of data with comparable count rates.

Vaughan, B. A.↗

Kasner solutions, climbing scalars and big-bang singularity

We elaborate on a recently discovered phenomenon where a scalar field close to big-bang is forced to climb a steep potential by its dynamics. We analyze the phenomenon in more general terms by writing the leading order equations of motion near the singularity. We formulate the conditions for climbing to exist in the case of several scalars and after inclusion of higher-derivative corrections and we apply our results to some models of moduli stabilization. We analyze an example with steep stabilizing potential and notice again a related critical behavior: for a potential steepness above a critical value, going backwards towards big-bang, the scalar undergoes wilder oscillations, with the steep potential pushing it back at every passage and not allowing the scalar to escape to infinity. Whereas it was pointed out earlier that there are possible implications of the climbing phase to CMB, we point out here another potential application, to the issue of initial conditions in inflation.

79 ASTRONOMY AND ASTROPHYSICS↗

Horizon radiation reaction forces

Using Effective Field Theory (EFT) methods, we compute the effects of horizon dissipation on the gravitational interactions of relativistic binary black hole systems. We assume that the dynamics is perturbative, i.e it admits an expansion in powers of Newton’s constant (post-Minkowskian, or PM, approximation). As applications, we compute corrections to the scattering angle in a black hole collision due to dissipative effects to leading PM order, as well as the post-Newtonian (PN) corrections to the equations of motion of binary black holes in non-relativistic orbits, which represents the leading order finite size effect in the equations of motion. The methods developed here are also applicable to the case of more general compact objects, eg. neutron stars, where the magnitude of the dissipative effects depends on non-gravitational physics (e.g, the equation of state for nuclear matter).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Libration of hydroxyl groups in layered aluminum (oxy)hydroxides and other material analogs: insights from inelastic neutron scattering and theory

We analyzed the hydroxyl librational signatures of five structurally related aluminum (oxy)hydroxides, using inelastic neutron scattering (INS) and plane-wave lattice dynamics simulations. A clear trend across these aluminum-containing phases illustrates the relationship between hydrogen bonding, local atomic structure, and the spectral location and profile of the librational bands. The INS spectra have been compared to previous optical spectroscopy and computational studies, highlighting the complementary nature of the INS technique. Taking into account other structurally or chemically related material analogs, we have identified a correlation between a blueshift (to higher energy) of the upper librational band edge and the geometry of the hydrogen bond interactions, mirroring (with opposite correlation) the well-known redshift in the intramolecular O–H stretching energy with increasing hydrogen bond strength. For hydroxyl groups that do not participate in hydrogen bonding effectively, the bending librations occur at lower energies and hybridize with metal–oxygen lattice modes. Standard density functional theory approximations, including dispersion corrections, struggle to correctly predict vibrational frequencies of motions dominated by H but perform well for metal–oxygen modes, allowing us to make detailed mode assignments in several cases, including a demonstration of how layer-to-layer disorder in boehmite hydrogen bond orientations is reflected in the sharp but minor low energy peaks (at ∼70–80 meV) of the INS spectrum.

Wang, Hsiu-Wen [Oak Ridge National Laboratory (ORN↗

Recent results on nuclear structure functions for light nuclei

We discuss the nuclear EMC effect with particular emphasis on recent data for light nuclei including {sup 2}H, {sup 3}He, {sup 4}He, {sup 9}Be, {sup 12}C and {sup 14}N. In order to verify the consistency of available data, we calculate the {chi}{sup 2} deviation between different data sets. We find a good agreement between the results from the NMC, SLAC E139, and HERMES experiments. However, our analysis indicates an overall normalization offset of about 2% in the data from the recent JLab E03-103 experiment with respect to previous data for nuclei heavier than {sup 3}He. We also discuss the extraction of the neutron/proton structure function ratio F{sub 2}{sup n}/F{sub 2}{sup p} from the nuclear ratios {sup 3}He/{sup 2}H and {sup 2}H/{sup 1}H. Our analysis shows that the E03-103 data on {sup 3}He/{sup 2}H require a renormalization of about 3% in order to be consistent with the F{sub 2}{sup n}/F{sub 2}{sup p} ratio obtained from the NMC experiment. After such a renormalization, the {sup 3}He data from the E03-103 data and HERMES experiments are in a good agreement. We also present a detailed comparison between data and model calculations, which include a description of the nuclear binding, Fermi motion and off-shell corrections to the structure functions of bound proton and neutron, as well as the nuclear pion and shadowing corrections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗