Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Numerical investigation of inertial sphere impaction on a cylinder in subcritical flow

We investigated the accuracy of a Lagrangian scheme for simulating both the motion and wall impaction of neutrally buoyant inertial spheres (8.85 ≤ St ≤ 18.04) moving in the subcritical regime (Re = 10,972 and 22,366) of flows past a circular cylinder. The accuracy of the eddy-resolving simulations of the flow field was verified based on available data at nearly comparable flow conditions. The accuracy of the eddy-resolving simulations of the flow field was verified based on available data at nearly comparable flow conditions. The accuracy of the particle tracking scheme was verified with respect to corresponding experimental data in a laboratory flume. Particle dispersion en route to the circular cylinder is mostly driven by the flow disturbance from the particle injector tube. The trends in collision rates are largely explained by the rate of particle entertainment into the boundary layer around the cylinder and the inertial condition of the spheres in this proximity region—both of which can be better assessed by post-processing of the numerical outcomes. Here, the primary incentive to undertake this work was the need for validating a particle-based method for quantifying the hydraulic stressors leading to bodily damage of fish passing flows influenced by hydraulic infrastructure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetric evaluations of the interplay effect in respiratory-gated intensity-modulated radiation therapy

The interplay between a mobile target and a dynamic multileaf collimator can compromise the accuracy of intensity-modulated radiation therapy (IMRT). Our goal in this study is to investigate the dosimetric effects caused by the respiratory motion during IMRT. A moving phantom was built to simulate the typical breathing motion. Different sizes of the gating windows were selected for gated deliveries. The residual motions during the beam-on period ranged from 0.5 to 3 cm. An IMRT plan with five treatment fields from different gantry angles were delivered to the moving phantom for three irradiation conditions: Stationary condition, moving with the use of gating system, and moving without the use of gating system. When the residual motion was 3 cm, the results showed significant differences in dose distributions between the stationary condition and the moving phantom without gating beam control. The overdosed or underdosed areas enclosed about 33% of the treatment area. In contrast, the dose distribution on the moving phantom with gating window set to 0.5 cm showed no significant differences from the stationary phantom. With the appropriate setting of the gating window, the deviation of dose from the respiratory motion can be minimized. It appeals that limiting the residual motion to less than 0.5 cm is critical for the treatments of mobile structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

SIMULATING ASTRO-H OBSERVATIONS OF SLOSHING GAS MOTIONS IN THE CORES OF GALAXY CLUSTERS

Astro-H will be the first X-ray observatory to employ a high-resolution microcalorimeter, capable of measuring the shift and width of individual spectral lines to the precision necessary for estimating the velocity of the diffuse plasma in galaxy clusters. This new capability is expected to bring significant progress in understanding the dynamics, and therefore the physics, of the intracluster medium. However, because this plasma is optically thin, projection effects will be an important complicating factor in interpreting future Astro-H measurements. To study these effects in detail, we performed an analysis of the velocity field from simulations of a galaxy cluster experiencing gas sloshing and generated synthetic X-ray spectra, convolved with model Astro-H Soft X-ray Spectrometer (SXS) responses. We find that the sloshing motions produce velocity signatures that will be observable by Astro-H in nearby clusters: the shifting of the line centroid produced by the fast-moving cold gas underneath the front surface, and line broadening produced by the smooth variation of this motion along the line of sight. The line shapes arising from inviscid or strongly viscous simulations are very similar, indicating that placing constraints on the gas viscosity from these measurements will be difficult. Our spectroscopic analysis demonstrates that, for adequate exposures, Astro-H will be able to recover the first two moments of the velocity distribution of these motions accurately, and in some cases multiple velocity components may be discerned. The simulations also confirm the importance of accurate treatment of point-spread function scattering in the interpretation of Astro-H/SXS spectra of cluster plasmas.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of point defects on grain boundary motion.

This work addresses the influence of point defects, in particular vacancies, on the motion of grain boundaries. If there is a non-equilibrium concentration of point defects in the vicinity of an interface, such as due to displacement cascades in a radiation environment, motion of the interface to sweep up the defects will lower the energy and provide a driving force for interface motion. Molecular dynamics simulations are employed to examine the process for the case of excess vacancy concentrations in the vicinity of two grain boundaries. It is observed that the efficacy of the presence of the point defects in inducing boundary motion depends on the balance of the mobility of the defects with the mobility of the interfaces. In addition, the extent to which grain boundaries are ideal sinks for vacancies is evaluated by considering the energy of boundaries before and after vacancy absorption.

36 MATERIALS SCIENCE↗

Modeling Solids in Nuclear Astrophysics with Smoothed Particle Hydrodynamics

Abstract Smoothed particle hydrodynamics (SPH) is a frequently applied tool in computational astrophysics to solve the fluid dynamics equations governing the systems under study. For some problems, for example when involving asteroids and asteroid impacts, the additional inclusion of material strength is necessary in order to accurately describe the dynamics. In compact stars, that is white dwarfs and neutron stars, solid components are also present. Neutron stars have a solid crust, which is the strongest material known in nature. However, their dynamical evolution, when modeled via SPH or other computational fluid dynamics codes, is usually described as a purely fluid dynamics problem. Here, we present the first 3D simulations of neutron star crustal toroidal oscillations including material strength with the Los Alamos National Laboratory SPH code FleCSPH. In the first half of the paper, we present the numerical implementation of solid material modeling together with standard tests. The second half is on the simulation of crustal oscillations in the fundamental toroidal mode. Here, we dedicate a large fraction of the paper to approaches that can suppress numerical noise in the solid. If not minimized, the latter can dominate the crustal motion in the simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-J-211: Design and Study of In-House Software Based Respiratory Motion Monitoring, Controlling and Breath-Hold Device for Gated Radiotherapy

Purpose: The purpose of this present work was to fabricate an in-house software based respiratory monitoring, controlling and breath-hold device using computer software programme which guides the patient to have uniform breath hold in response to request during the gated radiotherapy. Methods: The respiratory controlling device consists of a computer, inhouse software, video goggles, a highly sensitive sensor for measurement of distance, mounting systems, a camera, a respiratory signal device, a speaker and a visual indicator. The computer is used to display the respiratory movements of the patient with digital as well as analogue respiration indicators during the respiration cycle, to control, breath-hold and analyze the respiratory movement using indigenously developed software. Results: Studies were conducted with anthropomophic phantoms by simulating the respiratory motion on phantoms and recording the respective movements using the respiratory monitoring device. The results show good agreement between the simulated and measured movements. Further studies were conducted for 60 cancer patients with several types of cancers in the thoracic region. The respiratory movement cycles for each fraction of radiotherapy treatment were recorded and compared. Alarm indications are provided in the system to indicate when the patient breathing movement exceeds the threshold level. This will help the patient to maintain uniform breath hold during the radiotherapy treatment. Our preliminary clinical test results indicate that our device is highly reliable and able to maintain the uniform respiratory motion and breathe hold during the entire course of gated radiotherapy treatment. Conclusion: An indigenous respiratory monitoring device to guide the patient to have uniform breath hold device was fabricated. The alarm feature and the visual waveform indicator in the system guide the patient to have normal respiration. The signal from the device can be connected to the radiation unit in near future to carry out the gated radiotherapy treatment.

60 APPLIED LIFE SCIENCES↗

(Invited) Comprehensive Assessment of Oxide Memristors As Post-CMOS Memory and Logic Devices

As CMOS technology approaches the end of its scaling, oxide-based memristors have become one of the leading candidates for post-CMOS memory and logic devices. In orderTo facilitate the understanding of physical switching mechanisms and accelerate experimental development of memristors, we have developed a three-dimensional fully-coupled electrical and thermal transport model, which captures all the important processes that drive memristive switching and is applicable for simulating a wide range of memristors. Moreover, the model is applied to simulate the RESET and SET switching in a 3D filamentary TaOx memristor. Extensive simulations show that the switching dynamics of the bipolar device is determined by thermally-activated field-dominant processes: with Joule heating, the raised temperature enables the movement of oxygen vacancies, and the field drift dominates the overall motion of vacancies. Simulated current-voltage hysteresis and device resistance profiles as a function of time and voltage during RESET and SET switching show good agreement with experimental measurement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Finite Element Modeling of Spent Nuclear Fuel in Dry Storage under Seismic Excitation

Spent nuclear fuel (SNF) is currently stored at independent spent fuel storage installations (ISFSIs) at nuclear power plant sites across the US. The US Department of Energy (DOE) Spent Fuel and Waste Science and Technology (SFWST) program is currently working to understand the response of SNF during a seismic event. This investigation is part of a long-term effort by DOE to quantify the external mechanical loads on SNF. The SFWST program has recently completed campaigns evaluating SNF behavior during normal conditions of transport and in 30 cm package drop scenarios; both campaigns included a combination of testing and modeling. Likewise, the investigation into seismic response of SNF will include full-size shake table tests of a vertical storage overpack containing instrumented surrogate fuel assemblies, as well as pre- and post-test finite element modeling. This work focuses on the development of finite element models simulating the planned test configuration. The seismic response is calculated at two scales: at the package level, and at the fuel level. The package level model evaluates the behavior of the storage overpack and its contents in response to the ground motions of a representative earthquake. The motion of the package is input to the fuel level model, which consists of a detailed finite element model of a 17x17 or 16x16 pressurized water reactor (PWR) fuel assembly or of a 10x10 boiling water reactor (BWR) fuel assembly. The stress and strain on individual components such as fuel rods and guide tubes are extracted from this model. This work details the SNF response to various input ground motions, considering representative earthquakes in the Central and Eastern US under various site conditions. Also discussed is the development of a “reduced scope” finite element model of the SNF, which consists of a single fuel rod while retaining the dynamic response of the entire fuel assembly. This reduced scope model addresses the significant computational expense of modeling the SNF under long-duration input ground motions and facilitates simulating additional parameter variations of the model beyond the as-tested configuration. The modeling results provide important insight that will help to inform future testing and modeling efforts by the SFWST program to close the knowledge gap related to external loads on SNF.

Kadooka, Kevin↗

GROWTH OF MAGNETIC FIELDS INDUCED BY TURBULENT MOTIONS

We present numerical simulations of driven magnetohydrodynamic (MHD) turbulence with weak/moderate imposed magnetic fields. The main goal is to clarify dynamics of magnetic field growth. We also investigate the effects of the imposed magnetic fields on the MHD turbulence, including, as a limit, the case of zero external field. Our findings are as follows. First, when we start off simulations with weak mean magnetic field only (or with small scale random field with zero imposed field), we observe that there is a stage at which magnetic energy density grows linearly with time. Runs with different numerical resolutions and/or different simulation parameters show consistent results for the growth rate at the linear stage. Second, we find that, when the strength of the external field increases, the equilibrium kinetic energy density drops by roughly the product of the rms velocity and the strength of the external field. The equilibrium magnetic energy density rises by roughly the same amount. Third, when the external magnetic field is not very strong (say, less than {approx}0.2 times the rms velocity when measured in the units of Alfven speed), the turbulence at large scales remains statistically isotropic, i.e., there is no apparent global anisotropy of order B {sub 0}/v. We discuss implications of our results on astrophysical fluids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-31: Monitor Interfractional Variation of Tumor Respiratory Motion Using 4D KV Conebeam Computed Tomography for Stereotactic Body Radiation Therapy of Lung Cancer

Purpose: 4DCT has been widely used to generate internal tumor volume (ITV) for a lung tumor for treatment planning. However, lung tumors may show different respiratory motion on the treatment day. The purpose of this study is to evaluate 4D KV conebeam computed tomography (CBCT) for monitoring tumor interfractional motion variation between simulation and each fraction of stereotactic body radiation therapy (SBRT) for lung cancer. Methods: 4D KV CBCT was acquired with the Elekta XVI system. The accuracy of 4D KV CBCT for image-guided radiation therapy (IGRT) was tested with a dynamic thorax motion phantom (CIRS, Virginia) with a linear amplitude of 2 cm. In addition, an adult anthropomorphic phantom (Alderson, Rando) with optically stimulated luminescence (OSL) dosimeters embedded at the center and periphery of a slab of solid water was used to measure the dose of 4D KV CBCT and to compare it with the dose with 3D KV CBCT. The image registration was performed by aligning\ each phase images of 4D KV CBCT to the planning images and the final couch shifts were calculated as a mean of all these individual shifts along each direction.A workflow was established based on these quality assurance tests for lung cancer patients. Results: 4D KV CBCT does not increase imaging dose in comparison to 3D KV CBCT. Acquisition of 4D KV CBCT is 4 minutes as compared to 2 minutes for 3D KV CBCT. Most of patients showed a small daily variation of tumor respiratory motion about 2 mm. However, some patients may have more than 5 mm variations of tumor respiratory motion. Conclusion: The radiation dose does not increase with 4D KV CBCT. 4D KV CBCT is a useful tool for monitoring interfractional variations of tumor respiratory motion before SBRT of lung cancer patients.

60 APPLIED LIFE SCIENCES↗

Role of Vibrational Dynamics on Excited-State Electronic Coherence in a Binuclear Platinum Complex

Long-lived quantum coherence between excited electronic states can enable highly efficient energy and charge transport processes in chemical systems. Recent pump-probe experiments on binuclear platinum complexes identified persistent, periodic beating of transient absorption anisotropy signals, indicating long excited-state coherence lifetimes. Our previous simulations of the electronic dynamics of these complexes indicate that coherence lifetimes are sensitive to the balance between competitive electronic couplings. The complexes with shorter Pt-Pt distances underwent no appreciable dephasing in the limit of static nuclei, motivating the inclusion of nuclear motion into our simulations. The tert-butyl-substituted complex is studied in this work using the Ehrenfest method for mixed quantum classical dynamics to investigate the role of vibrational dynamics on a complex shown to support coherence lifetimes. Results indicate that the inclusion of excited-state vibrations drives a rapid collapse of the two-state coherence prior to the experimentally determined intersystem crossing. This further suggests singlet excited-state coherences may not be prerequisites for long-lived triplet coherences.

Radler, Joseph J.↗

Finite element formulation of fluctuating hydrodynamics for fluids filled with rigid particles using boundary fitted meshes

In this paper, we present a finite element implementation of fluctuating hydrodynamics with a moving boundary fitted mesh for treating the suspended particles. The thermal fluctuations are incorporated into the continuum equations using the Landau and Lifshitz approach [1]. The proposed implementation fulfills the fluctuation–dissipation theorem exactly at the discrete level. Since we restrict the equations to the creeping flow case, this takes the form of a relation between the diffusion coefficient matrix and friction matrix both at the particle and nodal level of the finite elements. Brownian motion of arbitrarily shaped particles in complex confinements can be considered within the present formulation. A multi-step time integration scheme is developed to correctly capture the drift term required in the stochastic differential equation (SDE) describing the evolution of the positions of the particles. The proposed approach is validated by simulating the Brownian motion of a sphere between two parallel plates and the motion of a spherical particle in a cylindrical cavity. The time integration algorithm and the fluctuating hydrodynamics implementation are then applied to study the diffusion and the equilibrium probability distribution of a confined circle under an external harmonic potential.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of wrap mode impact on Pseudomonas aeruginosa motion in the chemotactic field of fungi

An agent-based discrete computational model biologically calibrated to Pseudomonas aeruginosa migration is used to explore the impacts of bacterial reversals and wrap mode on the efficiency of motion in different environments, both with and without chemotaxis. It is first shown that wrap mode increases the exploration of continuous multimodal chemotactic profiles such as those produced by biologically relevant fungal networks. For cells undergoing a run-reverse pattern, it is shown that the bacteria are likely to remain at the first local chemoattractant maximal production site on a hypha they find. However, with wrap mode, the bacteria can more easily escape these local sites to further explore their neighboring environment along the fungi, suggesting that wrap mode may be beneficial for migration along the fungi in liquid. In a different set of simulations of bacterial motion close to an isolated chemotactic source, wrap mode is shown to increase the ability of a bacterium to reorient toward the source while reducing the overall motion required for similar chemotactic efficiency as a run-reverse strategy, suggesting a potential metabolic benefit. In contrast, model simulations show that wrap mode can increase the rate of dispersal of P. aeruginosa in a nonchemotactic environment.

Hansen, Austin [University of California, Riversid↗

A practical perspective on the implementation of hyperdynamics for accelerated simulation

Consideration is given to several practical issues arising during the implementation of hyperdynamics, a methodology that extends the time scale of the conventional molecular dynamics simulation potentially by orders of magnitude. First, the methodology is reformulated in terms of the transition rate based on the buffer region approach (buffer rate), which can describe transitions in more general contexts than the transition state theory (TST). It will be shown that hyperdynamics can exactly preserve the buffer rate as well as the TST rate, which broadens the scope of the method. Next, the originally proposed scheme to compute the boost factor on-the-fly is reviewed and some alternative methods, one of which uses the umbrella sampling method, are presented. Finally, the methodology is validated in the context of a 1-dimensional example potential and a 3-dimensional simulation of the motion of an atomic force microscope tip moving along a surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗