Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Hiding the Higgs boson with multiple scalars

We consider models with multiple Higgs scalar gauge singlets and the resulting restrictions on the parameters from precision electroweak measurements. In these models, the scalar singlets mix with the SU(2){sub L} Higgs doublet, potentially leading to reduced couplings of the scalars to fermions and gauge bosons relative to the standard model Higgs boson couplings. Such models can make the Higgs sector difficult to explore at the LHC. We emphasize the new physics resulting from the addition of at least two scalar Higgs singlets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near-term measurements with 21 cm intensity mapping: Neutral hydrogen fraction and BAO at z<2

It is shown that 21 cm intensity mapping could be used in the near term to make cosmologically useful measurements. Large scale structure could be detected using existing radio telescopes, or using prototypes for dedicated redshift survey telescopes. This would provide a measure of the mean neutral hydrogen density, using redshift space distortions to break the degeneracy with the linear bias. We find that with only 200 hours of observing time on the Green Bank Telescope, the neutral hydrogen density could be measured to 25% precision at redshift 0.54<z<1.09. This compares favorably to current measurements, uses independent techniques, and would settle the controversy over an important parameter that impacts galaxy formation studies. In addition, a 4000 hour survey would allow for the detection of baryon acoustic oscillations, giving a cosmological distance measure at 3.5% precision. These observation time requirements could be greatly reduced with the construction of multiple pixel receivers. Similar results are possible using prototypes for dedicated cylindrical telescopes on month time scales, or Square Kilometre Array pathfinder aperture arrays on day time scales. Such measurements promise to improve our understanding of these quantities while beating a path for future generations of hydrogen surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Cellulose assembles into helical bundles of uniform handedness in cell walls with abnormal pectin composition

Plant cells and organs grow into a remarkable diversity of shapes, as directed by cell walls composed primarily of polysaccharides such as cellulose and multiple structurally distinct pectins. The properties of the cell wall that allow for precise control of morphogenesis are distinct from those of the individual polysaccharide components. For example, cellulose, the primary determinant of cell morphology, is a chiral macromolecule that can self-assemble in vitro into larger-scale structures of consistent chirality, and yet most plant cells do not display consistent chirality in their growth. One interesting exception is the Arabidopsis thaliana rhm1 mutant, which has decreased levels of the pectin rhamnogalacturonan-I and causes conical petal epidermal cells to grow with a left-handed helical twist. Here, we show that in rhm1 the cellulose is bundled into large macrofibrils, unlike the evenly distributed microfibrils of the wild type. This cellulose bundling becomes increasingly severe over time, consistent with cellulose being synthesized normally and then self-associating into macrofibrils. We also show that in the wild type, cellulose is oriented transversely, whereas in rhm1 mutants, the cellulose forms right-handed helices that can account for the helical morphology of the petal cells. Furthermore, our results indicate that when the composition of pectin is altered, cellulose can form cellular-scale chiral structures in vivo, analogous to the helicoids formed in vitro by cellulose nano-crystals. We propose that an important emergent property of the interplay between rhamnogalacturonan-I and cellulose is to permit the assembly of nonbundled cellulose structures, providing plants flexibility to orient cellulose and direct morphogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Super-swelling behavior of stacked lipid bilayer systems

Bilayer systems comprising lipid mixtures are the most well-studied model of biological membranes. While the plasma membrane of the cell is a single bilayer, many intra- and extra-cellular biomembranes comprise stacks of bilayers. Most bilayer stacks in nature are periodic, maintaining a precise water layer separation between bilayers. That equilibrium water separation is governed by multiple inter-bilayer forces and is highly responsive. Biomembranes re-configure inter-bilayer spacing in response to temperature, composition, or mass transport cues. In synthetic bilayer systems for applications in cosmetics or topical treatments, control of the hydration level is a critical design handle. Herein we investigate a binary lipid system that leverages key inter-bilayer forces leading to unprecedented levels of aqueous swelling while maintaining a coherent multilamellar form. We found that combining cationic lipids with bicontinuous cubic phase-forming lipids (lipids with positive Gaussian modulus), results in the stabilization of multilamellar phases against repulsive steric forces that typically lead to bilayer delamination at high degrees of swelling. Using ultra-small-angle X-ray scattering alongside confocal laser scanning microscopy, we characterized various super-swelled states of 1,2-dioleoyl-3-trimethylammonium-propane (DOTAP) and glycerol monooleate (GMO) lipids, as well as other analogous systems, at varied concentration and molar ratios. Through these experiments we established swelling profiles of various binary lipid systems that were near-linear with decreasing lipid volume fraction, showing maximum swelling with periodicity well above 200 nanometers.

42 ENGINEERING↗

The COHERENT Experiment at the Spallation Neutron Source

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino- nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the N=2 dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New Reflected Target Optical Assessment System: Stage 1 Development Results

NREL has completed stage 1 development of an indoor optical measurement tool for fully assembled heliostats and single facets. This tool began as an indoor version of NREL’s outdoor Non-Intrusive Optical (NIO) measurement technique [1]. It uses similar techniques to other available tools (deflectometry, photogrammetry, etc.), but is designed to require very little infrastructure, labor, and time to set up and collect surface slope and canting measurements, making it a valuable tool for quality assurance and laboratory measurement of heliostat optics. It accomplishes this by using computer vision, photogrammetry, and multiple images stitched together to minimize the printed target size and required setup precision. This adaptable setup is useful for taking measurements at a variety of heliostat pointing angles, and for measuring fully assembled heliostats on the assembly line. In this paper, we describe the methodology behind the measurement system, present an initial analysis of its uncertainty and sensitivity, and compare it with established optical measurement systems.

Kesseli, Devon (ORCID:0000000193113036)↗

The Meson Spectrum From Lattice QCD

I will report on recent progress in extracting the spectrum of excited mesons from lattice QCD computations. Spectra of mesons across all $J^{PC}$ with $J \le 4$ are now accessible with multiple excited states in each channel. Exotic hybrid meson results of unprecedented statistical precision suggest that these enigmatic states should indeed be within the energy reach of the GlueX experiment at JLab 12 GeV. I will also discuss current attempts being made to study the decay of resonances within QCD and how lattice QCD results can be used to build phenomenological models constrained by non- perturbative QCD.

Dudek, Jozef↗

A New Reflected Target Optical Assessment System - Stage 1 Development Results: Preprint

NREL has completed stage 1 development of an indoor optical measurement tool for fully assembled heliostats and single facets. This tool began as an indoor version of NREL's NIO technique. It uses similar techniques to other available tools (deflectometry, photogrammetry, etc.), but is designed require very little infrastructure, labor, and time to set up and collect surface slope and canting measurements on fully assembled heliostats and parabolic trough facets, making it a valuable tool for quality assurance and laboratory measurement of helio-stat optics. It accomplishes this by using computer vision, photogrammetry, and multiple images stitched together to minimize the printed target size and required setup precision. This adaptable setup is useful for taking measurements at a variety of heliostat pointing angles, and for measuring fully assembled heliostats on the assembly line. The measurement system's methodology and an analysis of its uncertainty, sensitivity and comparison with established optical measurement systems is described below.

canting↗

High throughput single cell multiomics platform [Abstract]

In this collaborative project, PNNL and Scienion will co-develop an integrated microfluidic technology to co-measure the transcriptome and proteome in single cells. The technology will enable us to efficiently separate proteins from mRNA transcripts between two microchips, barcode the molecules, and measure them separately with next-generation sequencing and mass spectrometry, respectively. Multicellular organisms contain diverse cell types and tremendous cell-to-cell heterogeneity that dictates a multitude of biological functions in both physiological and pathological environments. Even in the case of microbes, these genetically identical organisms can randomly differentiate into many subpopulations that assume different roles for the survival of the community. Bulk-scale measurements are insufficient to resolve such complexities. The development and applications of high throughput single-cell omics technologies have transformed our understanding of cellular heterogeneities and their differential responses to internal signaling events or external stimulations. Despite these advances, most current single-cell omic technologies provide information on only one type of biomolecule. Perse, such measurements provide incomplete information because the cell phenotype is determined by multiple layers of biomolecules and the interplay between genome, epigenome, transcriptome, and proteome. For example, mRNA abundance in one cell can not be precisely referred to the corresponding DNA and protein in other cells because of the potential subtle difference in genotype (e.g., somatic mutation or copy number variation) or phenotype (external microenvironment and cell-cell interactions). As such, parallel measurement of multiple biomolecules in the same single cells can offer unique advantages compared with measuring them separately in different single cells. Scienion is a world-leading biotech company focusing on precision liquid handling and its application in single-cell whole-genome sequencing and RNA sequencing. PNNL is the leading institution in ultrasensitive mass spectrometry, microfluidics, and untargeted single-cell proteomics (scProteomics). This collaboration will facilitate a unique fusion between scTranscriptomics capability at Scienion and scProteomics capabilities at PNNL to, for the first time, perform both untargeted transcriptomics and proteomics from the same single cells.

59 BASIC BIOLOGICAL SCIENCES↗

The Nab experiment: A precision measurement of unpolarized neutron beta decay

Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, λ = gA/gV, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter a with a precision of δa/a = 10 -3 and the Fierz interference term b to δb = 3 × 10 -3 in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio λ with a precision of δλ/λ = 0.03% that will allow an evaluation of Vud and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.

Fry, Jason↗

Simulation of the Nondestructive Assay of 237 Np Using Active Neutron Multiplicity Counting

In this work, the epithermal neutron multiplicity counter (ENMC) and an organic scintillator mul- tiplicity counter (OSMC) are compared in the assay of 237 Np, a potentially weapons-usable isotope, using active neutron multiplicity counting. In active neutron multiplicity counting, the neutron doubles and triples multiplicity rates are used to analytically calculate sample mass. To distinguish the masses of two different samples, the measured triples and doubles rates of each sample must be separated by one standard deviation. Here, the time it takes each system to separate the measured triples multiplicity rates was compared using 20 metal samples of 237 Np with masses logarithmi- cally distributed between 10 and 1000 g. The results show that the OSMC can distinguish the smallest masses (10.0 and 12.7 g) beyond one standard deviation in 20 minutes, and the ENMC requires more than 400 times the measurement time to obtain the same precision. Similarly, the OSMC is at least 4.5 times faster than the ENMC in separating the doubles multiplicity rates.

42 ENGINEERING↗

A Load-Based Multiple-Partial Unloading Micro-Indentation Technique for Mechanical Property Evaluation

A load-based multiple-partial unloading microindentation technique has been developed for evaluating mechanical properties of materials. Comparing to the current prevailing nano/micro-indentation methods, which require precise measurements of the indentation depth and load, the proposed technique only measures indentation load and the overall indentation displacement (i.e. including displacement of the loading apparatus). Coupled with a multiple-partial unloading procedure during the indentation process, this technique results in a load-depth sensing indentation system capable of determining Young’s modulus of metallic alloys with flat, tubular, or curved architectures. Test results show consistent and correct elastic modulus values when performing indentation tests on standard alloys such as steel, aluminum, bronze, and single crystal superalloys. The proposed micro-indentation technique has led to the development of a portable loaddepth sensing indentation system capable of on-site, in-situ material property measurement.

36 MATERIALS SCIENCE↗

Design of Flexure-based Precision Transmission Mechanisms using Screw Theory

This paper enables the synthesis of flexure-based transmission mechanisms that possess multiple decoupled inputs and outputs of any type (e.g. rotations, translations, and/or screw motions), which are linked by designer-specified transmission ratios. A comprehensive library of geometric shapes is utilized from which every feasible concept that possesses the desired transmission characteristics may be rapidly conceptualized and compared before an optimal concept is selected. These geometric shapes represent the rigorous mathematics of screw theory and uniquely link a body's desired motions to the flexible constraints that enable those motions. This paper's impact is most significant to the design of nano-positioners, microscopy stages, optical mounts, and sensors. A flexure-based microscopy stage was designed, fabricated, and tested to demonstrate the utility of the theory.

42 ENGINEERING↗

In situ tuning of optomechanical crystals with nano-oxidation

Optomechanical crystals are a promising device platform for quantum transduction and sensing. Precise targeting of the optical and acoustic resonance frequencies of these devices is crucial for future advances on these fronts. However, fabrication disorder in these wavelength-scale nanoscale devices typically leads to inhomogeneous resonance frequencies. Here we achieve in situ , selective frequency tuning of optical and acoustic resonances in silicon optomechanical crystals via electric field-induced nano-oxidation using an atomic-force microscope. Our method can achieve a tuning range >2nm (0.13%) for the optical resonance wavelength in the telecom C-band, and >60MHz (1.2%) for the acoustic resonance frequency at 5 GHz. The tuning resolution of 1.1 pm for the optical wavelength and 150 kHz for the acoustic frequency allows us to spectrally align multiple optomechanical crystal resonators using a pattern generation algorithm. Our results establish a method for precise post-fabrication tuning of optomechanical crystals. This technique can enable coupled optomechanical resonator arrays, scalable resonant optomechanical circuits, and frequency matching of microwave-optical quantum transducers.

Hatipoglu, Utku (ORCID:0000000205119196)↗

Micromachined Silicon Platform for Precise Assembly of 2D Multilayer Laue Lenses for High-Resolution X-ray Microscopy

We report on a developed micromachined silicon platform for the precise assembly of 2D multilayer Laue lenses (MLLs) for high-resolution X-ray microscopy. The platform is 10 × 10 mm2 and is fabricated on ~500 µm thick silicon wafers through multiple steps of photolithography and deep reactive-ion etching. The platform accommodates two linear MLLs in a pre-defined configuration with precise angular and lateral position control. In this work, we discuss the design and microfabrication of the platform, and characterization regarding MLLs assembly, position control, repeatability, and stability. The results demonstrate that a micromachined platform can be used for the assembly of a variety of MLLs with different dimensions and optical parameters. The angular misalignment of 2D MLLs is well controlled in the range of the designed accuracy, down to a few millidegrees. The separation distance between MLLs is adjustable from hundreds to more than one thousand micrometers. The use of the developed platform greatly simplifies the alignment procedure of the MLL optics and reduces the complexity of the X-ray microscope. It is a significant step forward for the development of monolithic 2D MLL nanofocusing optics for high-resolution X-ray microscopy.

36 MATERIALS SCIENCE↗

Fission Spectrum Covariance Matrix and Sensitivity Coefficients for Response Parameter Uncertainty Estimation

This paper discusses the consistent usage of fission spectrum covariance matrices and sensitivity coefficients for response parameter uncertainty estimation. The effects of covariance matrix normalization on response parameter uncertainties are described from a mathematical point of view, along with their inter-relation with the constrained sensitivity coefficients. The numerical precision for practical renormalization of covariance matrices and the impact of the constrained sensitivity coefficients are also discussed by estimating the multiplication factor uncertainties due to fission spectrum uncertainties for a sodium-cooled fast burner core concept.

99 GENERAL AND MISCELLANEOUS↗

Oxalyl chloride, ClC(O)C(O)Cl: UV/vis spectrum and Cl atom photolysis quantum yields at 193, 248, and 351 nm

Oxalyl chloride, (ClCO){sub 2}, has been used as a Cl atom photolytic precursor in numerous laboratory kinetic and photochemical studies. In this study, the UV/vis absorption spectrum of (ClCO){sub 2} and the Cl atom quantum yields in its photolysis at 193, 248, and 351 nm are reported. The UV/vis spectrum was measured between 200 and 450 nm at 296 K using diode array spectroscopy in conjunction with an absolute cross section obtained at 213.9 nm. Our results are in agreement with the spectrum reported by Baklanov and Krasnoperov [J. Phys. Chem. A 105, 97-103 (2001)], which was obtained at 11 discrete wavelengths between 193.3 and 390 nm. Cl atom quantum yields, {Phi}({lambda}), were measured using pulsed laser photolysis coupled with time resolved atomic resonance fluorescence detection of Cl. The UV photolysis of (ClCO){sub 2} has been shown in previous studies to occur via an impulsive three-body dissociation mechanism, (COCl){sub 2}+ hv{yields} ClCO*+ Cl + CO (2), where the excited ClCO radical, ClCO*, either dissociates or stabilizes ClCO*{yields} Cl + CO (3a), {yields} ClCO (3b). ClCO is thermally unstable at the temperatures (253-298 K) and total pressures (13-128 Torr) used in our experiments ClCO + M {yields} Cl + CO + M (4) leading to the formation of a secondary Cl atom that was resolvable in the Cl atom temporal profiles obtained in the 248 and 351 nm photolysis of (ClCO){sub 2}. {Phi}(193 nm) was found to be 2.07 {+-} 0.37 independent of bath gas pressure (25.8-105.7 Torr, N{sub 2}), i.e., the branching ratio for channel 2a or the direct formation of 2Cl + 2CO in the photolysis of (ClCO){sub 2} is >0.95. At 248 nm, the branching ratio for channel 2a was determined to be 0.79 {+-} 0.15, while the total Cl atom yield, i.e., following the completion of reaction (4), was found to be 1.98 {+-} 0.26 independent of bath gas pressure (15-70 Torr, N{sub 2}). {Phi}(351 nm) was found to be pressure dependent between 7.8 and 122.4 Torr (He, N{sub 2}). The low-pressure limit of the total Cl atom quantum yield, {Phi}{sub 0}(351 nm), was 2.05 {+-} 0.24. As part of this work, rate coefficients for the thermal decomposition of ClCO were measured between 253 and 298 K at total pressures between 13 and 128 Torr (He and N{sub 2} bath gases). The N{sub 2} bath gas results were combined with the data reported in Nicovich et al. [J. Chem. Phys. 92, 3539-3544 (1990)] to yield k{sub 4}(T, N{sub 2}) = (4.7 {+-} 0.7) Multiplication-Sign 10{sup -10} exp [-(2987 {+-} 16)/T] cm{sup 3} molecule{sup -1} s{sup -1}, while the He bath gas data fit yielded k{sub 4}(T, He) = (2.3 {+-} 2.1) Multiplication-Sign 10{sup -10} exp [-(2886 {+-} 218)/T] cm{sup 3} molecule{sup -1} s{sup -1}. The quoted uncertainties are at the 2{sigma} level from the precision of the fit. In addition, the room temperature rate coefficient for the Cl + ClNO reaction was measured in this work to be (1.03 {+-} 0.10) Multiplication-Sign 10{sup -10} cm{sup 3} molecule{sup -1} s{sup -1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗