Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple views”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Single-Objective Airy Light-Sheet Imaging

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. Here, we demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

airy beam↗

SPECTROPOLARIMETRY OF C-CLASS FLARE FOOTPOINTS

We investigate the decay phase of a C-class flare in full-Stokes imaging spectropolarimetry with quasi-simultaneous measurements in the photosphere (6302.5 A line) and in the chromosphere (8542 A line) with the IBIS instrument. We analyze data from two fields of view, each spanning about 40'' Multiplication-Sign 80'' and targeting the two footpoints of the flare. A region of interest is identified from V/I images: a patch of opposite polarity in the smaller sunspot's penumbra. We find unusual flows in this patch at photospheric levels: a Doppler shift of -4 km s{sup -1}, but also a possible radial inflow into the sunspot of 4 km s{sup -1}. Such patches seem to be common during flares, but only high-resolution observations allowed us to see the inflow, which may be related to future flares observed in this region. Chromospheric images show variable overlying emission and flows and unusual Stokes profiles. We also investigate the irregular penumbra, whose formation may be blocked by the opposite polarity patch and flux emergence. The 40 minute temporal evolution depicts the larger of the flare ribbons becoming fainter and changing its shape. Measurable photospheric magnetic fields remain constant and we do not detect flare energy transport down from the chromosphere. We find no clear indications of impact polarization in the 8542 A line. We cannot exclude the possibility of impact polarization, because weaker signals may be buried in the prominent Zeeman signatures or it may have been present earlier during the flare.

79 ASTRONOMY AND ASTROPHYSICS↗

THE GALACTIC PLANE INFRARED POLARIZATION SURVEY (GPIPS)

The scientific motivation, data collection strategy, data reduction, and analysis methods are presented for the Galactic Plane Infrared Polarization Survey (GPIPS). The chief goal for the Survey was to reveal the nature of the magnetic field threading the Galactic disk, in particular through regions of low to moderate extinction (1-20 mag of A{sub V} ) and star formation in the cool interstellar medium. The Survey region spans 76 deg{sup 2} of the northern Milky Way disk, from l = 18 Degree-Sign to 56 Degree-Sign and b =-1 Degree-Sign to +1 Degree-Sign . Linear polarimetric imaging observations began in 2006 in the near-infrared H band (1.6 {mu}m) using the Mimir instrument on the 1.8 m Perkins telescope, located outside Flagstaff, AZ. Mimir used a cold, fixed wire grid and a rotateable cold, compound half-wave plate to obtain 'step-and-integrate' polarimetry over its full 10 Multiplication-Sign 10 arcmin field of view. The GPIPS bright and faint polarimetric limits are approximately 7th and 15th mag, respectively, set by saturation and photon noise. Polarimetric uncertainties track with stellar magnitude, from about 0.1% to 25%, on average, from the brightest to faintest stars. Across the 3237 field GPIPS region, approximately 0.5 million stars are estimated to show detectable linear polarization (P/{sigma}{sub P} > 3); most of these have m{sub H} < 12. This represents many orders of magnitude improvement in the number of polarization measurements across this region. GPIPS observations are more than 90% complete and should finish in 2012.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of a cable-free system based on p-type MOSFET detectors for 'in vivo' entrance skin dose measurements in interventional radiology

Purpose: During radiological interventional procedures (RIP) the skin of a patient under examination may undergo a prolonged x-ray exposure, receiving a dose as high as 5 Gy in a single session. This paper describes the use of the OneDose{sup TM} cable-free system based on p-type MOSFET detectors to determine the entrance skin dose (ESD) at selected points during RIP. Methods: At first, some dosimetric characteristics of the detector, such as reproducibility, linearity, and fading, have been investigated using a C-arc as a source of radiation. The reference setting (RS) was: 80 kV energy, 40 cm Multiplication-Sign 40 cm field of view (FOV), current-time product of 50 mAs and source to skin distance (SSD) of 50 cm. A calibrated PMX III solid state detector was used as the reference detector and Gafchromic{sup Registered-Sign} films have been used as an independent dosimetric system to test the entire procedure. A calibration factor for the RS and correction factors as functions of tube voltage and FOV size have been determined. Results: Reproducibility ranged from 4% at low doses (around 10 cGy as measured by the reference detector) to about 1% for high doses (around 2 Gy). The system response was found to be linear with respect to both dose measured with the PMX III and tube voltage. The fading test has shown that the maximum deviation from the optimal reading conditions (3 min after a single irradiation) was 9.1% corresponding to four irradiations in one hour read 3 min after the last exposure. The calibration factor in the RS has shown that the system response at the kV energy range is about four times larger than in the MV energy range. A fifth order and fourth order polynomial functions were found to provide correction factors for tube voltage and FOV size, respectively, in measurement settings different than the RS. ESDs measured with the system after applying the proper correction factors agreed within one standard deviation (SD) with the corresponding ESDs measured with the reference detector. The ESDs measured with Gafchromic{sup Registered-Sign} films were in agreement within one SD compared to the ESDs measured using the OneDose{sup TM} system, as well. The global uncertainty associated to the OneDose{sup TM} system established in our experiments, ranged from 7% to 10%, depending on the duration of the RIP due to fading. These values are much lower than the uncertainty commonly accepted for general diagnostic practices (20%) and of about the same size of the uncertainty recommended for practices with high risk of deterministic side effects (7%). Conclusions: The OneDose{sup TM} system has shown a high sensitivity in the kV energy range and has been found capable of measuring the entrance skin dose in RIP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations of two new dose metrics proposed by AAPM Task Group 111 using the measurements with standard CT dosimetry phantoms

Purpose: AAPM Task Group 111 proposed to measure the equilibrium dose-pitch product D-caret{sub eq} for scan modes involving table translation and the midpoint dose D{sub L}(0) for stationary-table modes on the central and peripheral axes of sufficiently long (e.g., at least 40 cm) phantoms. This paper presents an alternative approach to calculate both metrics using the measurements of scanning the standard computed tomographic (CT) dosimetry phantoms on CT scanners.Methods: D-caret{sub eq} was calculated from CTDI{sub 100} and ε(CTDI{sub 100}) (CTDI{sub 100} efficiency), and D{sub L}(0) was calculated from D-caret{sub eq} and the approach to equilibrium function H(L) =D{sub L}(0)/D{sub eq}, where D{sub eq} was the equilibrium dose. CTDI{sub 100} may be directly obtained from several sources (such as medical physicist's CT scanner performance evaluation or the IMPACT CT patient dosimetry calculator), or be derived from CTDI{sub Vol} using the central to peripheral CTDI{sub 100} ratio (R{sub 100}). The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers [X. Li, D. Zhang, and B. Liu, Med. Phys. 39, 901–905 (2012); and ibid. 40, 031903 (10pp.) (2013)]. R{sub 100} was assessed for a series of GE, Siemens, Philips, and Toshiba CT scanners with multiple settings of scan field of view, tube voltage, and bowtie filter.Results: The calculated D{sub L}(0) and D{sub L}(0)/D{sub eq} in PMMA and water cylinders were consistent with the measurements on two GE CT scanners (LightSpeed 16 and VCT) by Dixon and Ballard [Med. Phys. 34, 3399–3413 (2007)], the measurements on a Siemens CT scanner (SOMATOM Spirit Power) by Descamps et al. [J. Appl. Clin. Med. Phys. 13, 293–302 (2012)], and the Monte Carlo simulations by Boone [Med. Phys. 36, 4547–4554 (2009)].Conclusions: D-caret{sub eq} and D{sub L}(0) can be calculated using the alternative approach. The authors have provided the required ε(CTDI{sub 100}) and H(L) data in two previous papers. R{sub 100} is presented for a majority of multidetector CT scanners currently on the market, and can be easily assessed for other CT scanners or operating conditions not covered in this study. The central to peripheral D{sub eq} ratio is about 1.50 and 1.12 times of R{sub 100} for the 32- and 16-cm diameter PMMA phantom, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

SOCRATES

SOCRATES is a Suite Of Comprehensive Rapid Analysis Tools for Environmental Sites. It provides tools to retrieve, filter, select, and view Hanford data and to perform multiple types of data analyses. SOCRATES currently includes four data analytics modules

Royer, Patrick↗

Utah FORGE Well 16A(78)-32 Core Photos

Images of core samples collected from Utah FORGE well 16A(78)-32. These images were created by stitching together multiple photographs resulting in a circumferential view of the cores exterior in two dimensions. Core footages (measured depths) are indicated in the file names, and are annotated on each image. The images, of which there are 30 in the .zip file, are in a .jpg format.

15 GEOTHERMAL ENERGY↗

Extensions of algebraic image operators: An approach to model-based vision

Researchers extend their previous research on a highly structured and compact algebraic representation of grey-level images which can be viewed as fuzzy sets. Addition and multiplication are defined for the set of all grey-level images, which can then be described as polynomials of two variables. Utilizing this new algebraic structure, researchers devised an innovative, efficient edge detection scheme. An accurate method for deriving gradient component information from this edge detector is presented. Based upon this new edge detection system researchers developed a robust method for linear feature extraction by combining the techniques of a Hough transform and a line follower. The major advantage of this feature extractor is its general, object-independent nature. Target attributes, such as line segment lengths, intersections, angles of intersection, and endpoints are derived by the feature extraction algorithm and employed during model matching. The algebraic operators are global operations which are easily reconfigured to operate on any size or shape region. This provides a natural platform from which to pursue dynamic scene analysis. A method for optimizing the linear feature extractor which capitalizes on the spatially reconfiguration nature of the edge detector/gradient component operator is discussed.

Lerner, Bao-Ting↗

Application of optical distributed sensing and computation to control of a large flexible spacecraft

Advances in real-time holography make possible the development of new distributed optical sensors and processors that may have application to the control of flexible structures. This paper presents the analytic evaluation of control system concepts utilizing this new technology on realistic spacecraft. The design of a distributed estimator based on this new optical sensing technique is targeted to vibration control of a complex spacecraft with multiple optical sensors, each of which views a portion of the spacecraft. A simulation of a complex truss structure that was flown in the Solar Array Flight Experiment is utilized to evaluate the performance of the estimator. It is shown that good performance can be obtained from a distributed estimator even in the presence of significant sensor noise.

Montgomery, R. C.↗

Plant Chlorophyll Content Imager with Reference Detection Signals

A portable plant chlorophyll imaging system is described which collects light reflected from a target plant and separates the collected light into two different wavelength bands. These wavelength bands, or channels, are described as having center wavelengths of 700 nm and 840 nm. The light collected in these two channels is processed using synchronized video cameras. A controller provided in the system compares the level of light of video images reflected from a target plant with a reference level of light from a source illuminating the plant. The percent of reflection in the two separate wavelength bands from a target plant are compared to provide a ratio video image which indicates a relative level of plant chlorophyll content and physiological stress. Multiple display modes are described for viewing the video images.

Spiering, Bruce A.↗

Conceptual Design and Dynamics Testing and Modeling of a Mars Tumbleweed Rover

The NASA Langley Research Center has been developing a novel concept for a Mars planetary rover called the Mars Tumbleweed. This concept utilizes the wind to propel the rover along the Mars surface, bringing it the potential to cover vast distances not possible with current Mars rover technology. This vehicle, in its deployed configuration, must be large and lightweight to provide the ratio of drag force to rolling resistance necessary to initiate motion from rest on the Mars surface. One Tumbleweed design concept that satisfies these considerations is called the Eggbeater-Dandelion. This paper describes the basic design considerations and a proposed dynamics model of the concept for use in simulation studies. It includes a summary of rolling/bouncing dynamics tests that used videogrammetry to better understand, characterize, and validate the dynamics model assumptions, especially the effective rolling resistance in bouncing/rolling dynamic conditions. The dynamics test used cameras to capture the motion of 32 targets affixed to a test article s outer structure. Proper placement of the cameras and alignment of their respective fields of view provided adequate image resolution of multiple targets along the trajectory as the test article proceeded down the ramp. Image processing of the frames from multiple cameras was used to determine the target positions. Position data from a set of these test runs was compared with results of a three dimensional, flexible dynamics model. Model input parameters were adjusted to match the test data for runs conducted. This process presented herein provided the means to characterize the dynamics and validate the simulation of the Eggbeater-Dandelion concept. The simulation model was used to demonstrate full scale Tumbleweed motion from a stationary condition on a flat-sloped terrain using representative Mars environment parameters.

Calhoun Philip C.↗

Using a Low Cost Flight Simulation Environment for Interdisciplinary Education

A multi-disciplinary and inter-disciplinary education is increasingly being emphasized for engineering undergraduates. However, often the focus is on interaction between engineering disciplines. This paper discusses the experience at Tuskegee University in providing interdisciplinary research experiences for undergraduate students in both Aerospace Engineering and Psychology through the utilization of a low cost flight simulation environment. The environment, which is pc-based, runs a low-cost of-the-shelf software and is configured for multiple out-of-the-window views and a synthetic heads down display with joystick, rudder and throttle controls. While the environment is being utilized to investigate and evaluate various strategies for training novice pilots, students were involved to provide them with experience in conducting such interdisciplinary research. On the global inter-disciplinary level these experiences included developing experimental designs and research protocols, consideration of human participant ethical issues, and planning and executing the research studies. During the planning phase students were apprised of the limitations of the software in its basic form and the enhancements desired to investigate human factors issues. A number of enhancements to the flight environment were then undertaken, from creating Excel macros for determining the performance of the 'pilots', to interacting with the software to provide various audio/video cues based on the experimental protocol. These enhancements involved understanding the flight model and performance, stability & control issues. Throughout this process, discussions of data analysis included a focus from a human factors perspective as well as an engineering point of view.

Khan, M. Javed↗

Development, Verification and Validation of Enclosure Radiation Capabilities in the CHarring Ablator Response (CHAR) Code

With the recent development of multi-dimensional thermal protection system (TPS) material response codes including the capabilities to account for radiative heating is a requirement. This paper presents the recent efforts to implement such capabilities in the CHarring Ablator Response (CHAR) code developed at NASA's Johnson Space Center. This work also describes the different numerical methods implemented in the code to compute view factors for radiation problems involving multiple surfaces. Furthermore, verification and validation of the code's radiation capabilities are demonstrated by comparing solutions to analytical results, to other codes, and to radiant test data.

Salazar, Giovanni↗

Development and Verification of Enclosure Radiation Capabilities in the CHarring Ablator Response (CHAR) Code

With the recent development of multi-dimensional thermal protection system (TPS) material response codes, the capability to account for surface-to-surface radiation exchange in complex geometries is critical. This paper presents recent efforts to implement such capabilities in the CHarring Ablator Response (CHAR) code developed at NASA's Johnson Space Center. This work also describes the different numerical methods implemented in the code to compute geometric view factors for radiation problems involving multiple surfaces. Verification of the code's radiation capabilities and results of a code-to-code comparison are presented. Finally, a demonstration case of a two-dimensional ablating cavity with enclosure radiation accounting for a changing geometry is shown.

Salazar, Giovanni↗

In-Flight Performance of the Ozone Monitoring Instrument

The Dutch-Finnish Ozone Monitoring Instrument (OMI) is an imaging spectrograph flying on NASA's EOS Aura satellite since 15 July 2004. OMI is primarily used to map trace-gas concentrations in the Earth's atmosphere, obtaining mid-resolution (0.4-0.6 nm) ultraviolet-visible (UV- VIS; 264-504 nm) spectra at multiple (30-60) simultaneous fields of view. Assessed via various approaches that include monitoring of radiances from selected ocean, land ice and cloud areas, as well as measurements of line profiles in the solar spectra, the instrument shows low optical degradation and high wavelength stability over the mission lifetime. In the regions relatively free from the slowly unraveling "row anomaly" (RA) the OMI irradiances have degraded by 3- 8 %, while radiances have changed by 1-2 %. The long-term wavelength calibration of the instrument remains stable to 0.005-0.020 nm.

ultraviolet↗

Using ADOPT Algorithm and Operational Data to Discover Precursors to Aviation Adverse Events

The US National Airspace System (NAS) is making its transition to the NextGen system and assuring safety is one of the top priorities in NextGen. At present, safety is managed reactively (correct after occurrence of an unsafe event). While this strategy works for current operations, it may soon become ineffective for future airspace designs and high density operations. There is a need for proactive management of safety risks by identifying hidden and "unknown" risks and evaluating the impacts on future operations. To this end, NASA Ames has developed data mining algorithms that finds anomalies and precursors (high-risk states) to safety issues in the NAS. In this paper, we describe a recently developed algorithm called ADOPT that analyzes large volumes of data and automatically identifies precursors from real world data. Precursors help in detecting safety risks early so that the operator can mitigate the risk in time. In addition, precursors also help identify causal factors and help predict the safety incident. The ADOPT algorithm scales well to large data sets and to multidimensional time series, reduce analyst time significantly, quantify multiple safety risks giving a holistic view of safety among other benefits. This paper details the algorithm and includes several case studies to demonstrate its application to discover the "known" and "unknown" safety precursors in aviation operation.

aviation safet↗

The Tiny Triplet Finder as a Versatile Track Segment Seeding Engine for Trigger Systems

In high energy physics experiment trigger systems, track segment seeding is a resource consuming function and the primary reason is the computing complexity of the segment finding process. As the Moore's Law is reaching its physical limit, reducing computing complexity should be carefully considered, rather than keep piling up silicon resources. The Tiny Triplet Finder is a scheme that reduces the computing complexity of the segment seeding. As a proof of concept, a 3D track segment seeding engine core based on the Tiny Triplet Finder has been implemented and tested in a low-cost FPGA device. The seeding engine is designed to preselect and group hits (stubs) from detector layers to feed subsequent track fitting stage. The seeding engine consists of a Hough transform space for r-z view and a Tiny Triplet Finder for r-phi view to implement 3D constraints. The seeding engine is organized as a pipeline so that each hit is processed in a single clock cycle. Taking advantage of the register-like storage block scheme which enables effectively resetting of a block RAM within a single clock cycle, clearing or refreshing the seeding engine takes only one clock cycles between two events. The Tiny Triplet Finder is also a generic coincidence finding scheme that can be used for many tasks. As a versatility demonstration, track segment finding performances for two distinctive detector geometries are tested in our seeding engine. In a collider barrel-layer geometry, the fake segment rates are studied for 3D (i.e., both r-phi and r-z views) and 2D (i.e., r-phi or r-z view only) configurations for high hit multiplicity events (>4000 hits/layer in the barrel region). Another detector geometry contains strip plane layers with timing information. The numbers of coincidences, both real or fake, with or without timing ("3D" or "2D") information at various hit multiplicities are studied.

43 PARTICLE ACCELERATORS↗