Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

HEU Removal from MNSR Reactors

This artifact is a slide presentation about spent HEU core removal of a Chinese-built Miniature Neutron Source Reactor (MNSR). The presentation describes the Skoda VPVR/M cask in detail and the auxiliary equipment needed to safely remove the spent HEU and transport it. Removal activities of MNSR spent HEU from Ghana and Nigeria MNSRs, and air transport from these countries to China are discussed. The International MNSR Training Facility in Ghana is also mentioned.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Disposition of Newly Generated Transuranic Waste at ORNL - 20107

ORNL operates the High Flux Isotope Reactor, which provides a high neutron source for production of isotopes for medical, industrial, and nuclear research programs and is the US DoE's center for production, storage, and distribution for TRU isotopes (plutonium through californium). Operation of these facilities results in the generation of CH-TRU and RH-TRU waste for disposal at the WIPP. This paper describes the program ORNL is implementing in collaboration with the Carlsbad Field Office National TRU Program Difficult Waste Team to disposition newly generated TRU waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of neutron radiation-induced nucleation of supercooled water

In this study, we present direct evidence for neutrons causing nucleation of supercooled water. Highly purified water (20 nm filtration) is cooled to well below freezing (as low as −20 °C) with a radioactive calibration source of neutrons/gamma-rays either present or removed during each of many control cooling runs for the same volume of water. When it is primarily neutrons irradiating the sample bulk, the non-equilibrium freezing point (also known as the “supercooling point”) is, on average, +0.7 °C warmer than the control equivalent, with a statistical significance of greater than 5 Sigma, with systematic uncertainty included. This effect is not observed with water in the presence of gamma-rays instead of neutrons. While these neutrons should have theoretically had sufficient energy to mount the energy barrier, corroborating our results, their raising of supercooling temperature has never been reported experimentally to the best of our knowledge. The potential to use deeply supercooled solutions, not only water, as metastable detectors for radiation and perhaps dark matter or neutrino physics presents now a new avenue for exploration.

Szydagis, Matthew↗

Particle physics at the European Spallation Source

Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world’s brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. Furthermore, these encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TORONE: Total Characterisation by Remote Observation of Nuclear Environments - 20591

This paper describes the autonomous robotic systems developed in the TORONE project (Total Characterisation by Remote Observation of Nuclear Environments) for combined characterisation by remote techniques in nuclear environments. There are four main components to the system. Firstly, robot operation which uses a Robot Operating System (ROS) allowing ease of communication between hardware and software alongside robot vision systems such as Lidar and/or photogrammetry. Secondly, radiation detection instrumentation for gamma and neutron sources which is also collimated for spatial resolution. Thirdly, photonic characterisation instrumentation for remote material identification by means of Raman spectroscopy and Laser induced breakdown spectroscopy (LIBS). Finally, a data management system is described which contains the TORONE characterisation data with the ability to overlay material characterisation information onto 3D maps of the nuclear environment. Preliminary results are described alongside discussion of some of the synergies of the combined approach. There are many applications of such an autonomous system in nuclear decommissioning, waste management and asset management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plasma pressure profiles in a sheared-flow-stabilized Z-pinch

We report the plasma pressure reached inside the central plasma column of a sheared-flow-stabilized Z-pinch using Thomson scattering measurements. Building on previously reported experimental results and the analysis methods established for the high temperature and moderate density plasmas generated on the FuZE device, we show evidence of a central plasma region with higher electron temperature and density, which is consistent with a pinch behavior. Elevated electron temperatures up to 2.25 ± 0.8 keV and densities up to (4.9±0.2)×1017 cm−3 are observed to temporally coincide with the fusion neutron production from the plasma. Reconstructed plasma pressure profiles highlight the presence of a several millimeter-wide column with elevated pressure whose location varies shot-to-shot. The plasma pressure rises as neutron production from the deuterium plasma increases, reaching a peak value of 2.6 kBar. This peak value is consistent with a radially force-balanced pinch equilibrium model based on the measured ∼320 kA pinch current. Complete datasets were obtained at two axial locations, 10 and 20 cm axial position from the tip of the central electrode, which corroborate the estimated neutron source axial lengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CHESS: The future direct geometry spectrometer at the second target station

CHESS, chopper spectrometer examining small samples, is a planned direct geometry neutron chopper spectrometer designed to detect and analyze weak signals intrinsic to small cross sections (e.g., small mass, small magnetic moments, or neutron absorbing materials) in powders, liquids, and crystals. CHESS is optimized to enable transformative investigations of quantum materials, spin liquids, thermoelectrics, battery materials, and liquids. The broad dynamic range of the instrument is also well suited to study relaxation processes and excitations in soft and biological matter. The 15 Hz repetition rate of the Second Target Station at the Spallation Neutron Source enables the use of multiple incident energies within a single source pulse, greatly expanding the information gained in a single measurement. Furthermore, the high flux grants an enhanced capability for polarization analysis. This enables the separation of nuclear from magnetic scattering or coherent from incoherent scattering in hydrogenous materials over a large range of energy and momentum transfer. This paper presents optimizations and technical solutions to address the key requirements envisioned in the science case and the anticipated uses of this instrument.

47 OTHER INSTRUMENTATION↗

Management of Fissionable Equivalent Mass Materials at ORNL - 20146

The US DOE manages an inventory of materials that contains a range of long-lived radioactive isotopes that were produced from the 1960's through the 1980's by irradiating targets in production reactors to produce special heavy isotopes for US DOE programmatic use, scientific research, and industrial and medical applications. Since the production reactors and enrichment facilities that produced many of these materials have been shut down, they are considered unique materials that are not likely to be produced again. ORNL uses these materials in US DoE's center for production, storage, and distribution of TRU isotopes (plutonium through californium) and other related nuclear research programs. ORNL also operates the High Flux Isotope Reactor, which provides a high neutron source for production of isotopes for medical, industrial, and nuclear research programs. As a result, ORNL has an inventory of radioisotopes that are being managed for ongoing research programs and being held for reuse because they have potential intrinsic value to US DOE. An initiative is underway at ORNL to better manage these materials, particularly focusing on those with high fissionable equivalent mass that could impact the ability to perform ongoing or new research projects. This paper describes the actions ORNL is taking to manage these inventories, many of which consist of TRU materials, through reuse and disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EWALD: A macromolecular diffractometer for the second target station

Revealing the positions of all the atoms in large macromolecules is powerful but only possible with neutron macromolecular crystallography (NMC). Neutrons provide a sensitive and gentle probe for the direct detection of protonation states at near-physiological temperatures and clean of artifacts caused by x rays or electrons. Currently, NMC use is restricted by the requirement for large crystal volumes even at state-of-the-art instruments such as the macromolecular neutron diffractometer at the Spallation Neutron Source. EWALD’s design will break the crystal volume barrier and, thus, open the door for new types of experiments, the study of grand challenge systems, and the more routine use of NMC in biology. EWALD is a single crystal diffractometer capable of collecting data from macromolecular crystals on orders of magnitude smaller than what is currently feasible. The construction of EWALD at the Second Target Station will cause a revolution in NMC by enabling key discoveries in the biological, biomedical, and bioenergy sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Virtual to Physical: Reinforcement Learning to Optimize SNS Particle Accelerator Controls

Complex accelerators must have control systems that can handle dynamic nonlinear environments. This makes traditional control methods unsuitable as they can struggle to adapt to these uncertainties. This provides an ideal environment for reinforcement learning algorithms as they are adaptable and generalizable. We present a reinforcement learning pipeline that can effectively handle the dynamics of a complex accelerator. We test and prove our pipelines capabilities on multiple environments including the Spallation Neutron Source (SNS) and the Beam Test Facility (BTF) at Oakridge National Lab (ORNL). Due to the limited time available to train an online algorithm like reinforcement learning on a real accelerator, we utilize a virtual twin accelerator (VIRAC) developed by ORNL to pretrain the policy and show its ability to converge in the virtual environment. We then test the adaptability of the pretrained RL model by applying it on the real accelerator and comparing the results. Utilizing our Scientific Optimization and Controls Toolkit (SOCT) and open-source standards such as Gymnasium we create and solve for a MEBT orbit correction problem in the SNS and an emittance maximization problem in the BTF. We show how Twin Delayed Deep Deterministic Policy Gradient (TD3) can solve this optimization environment in the virtual accelerator and transfer this policy onto the real accelerator for inference and model retraining. We show how reinforcement learning can be utilized as a control system for complex accelerators and provide a model pipeline for how an implementation performs and can be adapted to new accelerator control problems.

Kasparian, Armen [Thomas Jefferson National Accele↗

Origin, parameters, and underlying deformation mechanisms of propagating deformation bands in irradiated 316L stainless steel

Lüders-type propagating deformation bands were observed in specimens of irradiated 316L stainless steel samples removed from Spallation Neutron Source target vessels after service. Mechanical testing with digital image correlation (DIC) and in-situ tensile testing with scanning electron microscopy electron backscatter diffraction showed that the observed Lüders-type behavior was not related to the known transformation-induced plasticity or twinning-induced plasticity behavior. Instead, the phenomenon occurs at small local strain values before a significant amount of martensite or deformation twins appear in the microstructure. Microstructural analysis and in-situ mechanical test results suggest Lüders-type band formation and propagation were related to the appearance and evolution of defect-free channels—analogous to slip bands. A modified Swift equation with a Ludwigson-like component was offered to rationalize the phenomenon and model the strain-softening processes at small strain values. Finally, the results indicate complex microstructural processes and deformation mechanisms were active at small strain values and underline the benefits of advanced mechanical test approaches such as DIC.

36 MATERIALS SCIENCE↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

Impact of post-irradiation annealing on mechanical performance of irradiated 718 alloy

Here, the effect of post-irradiation annealing on solution-annealed 718 alloy was investigated using advanced mechanical testing, fractography, scanning electron microscopy, and transmission electron microscopy. Specimens were extracted from a proton beam window operated at the Spallation Neutron Source, irradiated with 940 MeV protons to a maximum dose of approximately 9.7 displacements per atom (dpa) at a calculated temperature not exceeding 110 °C while in service. Helium and hydrogen concentrations reached about 1700 and 6900 atomic parts per million (appm), respectively. Despite irradiation and high tensile strength (yield stress over 1 GPa), the material exhibited significant ductility. Annealing at 500 °C, 700 °C, and 900 °C for 30 min resulted in an appreciable decrease in yield strength and an increase in ductility for annealing treatments at 500 °C and 900 °C relative to the strength and ductility of the as-irradiated material. The presence of helium and hydrogen led to cavity formation and cleavage-like brittle features on fractured surfaces; however, high-magnification imaging revealed the presence of small-scale ductile dimples, indicating that the fracture mechanism remained mixed. The annealed specimens retained total elongation levels of 14–33 %, and there was no sudden drop in ductility after heat treatments. The ductility level in the irradiated and annealed material is notable despite the presence of helium and hydrogen.

36 MATERIALS SCIENCE↗

Early Fault Detection in Particle Accelerator Power Electronics Using Ensemble Learning

Early fault detection and fault prognosis are crucial to ensure efficient and safe operations of complex engineering systems such as the Spallation Neutron Source (SNS) and its power electronics (high voltage converter modulators). Following an advanced experimental facility setup that mimics SNS operating conditions, the authors successfully conducted 21 early fault detection experiments, where fault precursors are introduced in the system to a degree enough to cause degradation in the waveform signals, but not enough to reach a real fault. Nine different machine learning techniques based on ensemble trees, convolutional neural networks, support vector machines, and hierarchical voting ensembles are proposed to detect the fault precursors. Although all 9 models have shown a perfect and identical performance during the training and testing phase, the performance of most models has decreased in the next test phase once they got exposed to realworld data from the 21 experiments. The hierarchical voting ensemble, which features multiple layers of diverse models, maintains a distinguished performance in early detection of the fault precursors with 95% success rate (20/21 tests), followed by adaboost and extremely randomized trees with 52% and 48% success rates, respectively. The support vector machine models were the worst with only 24% success rate (5/21 tests). The study concluded that a successful implementation of machine learning in the SNS or particle accelerator power systems would require a major upgrade in the controller and the data acquisition system to facilitate streaming and handling big data for the machine learning models. In addition, this study shows that the best performing models were diverse and based on the ensemble concept to reduce the bias and hyperparameter sensitivity of individual models.

43 PARTICLE ACCELERATORS↗

High Flux Isotope Reactor (HFIR)

Oak Ridge National Laboratory’s High Flux Isotope Reactor (HFIR) is the highest-flux reactor-based neutron source in the United States. HFIR’s intense neutron flux and state-of-the-art facilities result in world-class capabilities, including neutron scattering, radioisotope production, materials irradiation, and neutron activation analysis. HFIR’s multimission capabilities are attributed to its versatile high-power-density core design consisting of a series of concentric regions, including a flux trap target region, an inner fuel element, an outer fuel element, a control element region, and a beryllium reflector. The pressurized, light-water-cooled research reactor operates at 85 MW and is fueled by 9.4 kg 235U.

Chandler, David↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Dataset for First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics

The Nab apparatus at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was designed to measure key observations in neutron beta decay, test the Standard Model's description of the weak interaction, and search for new physics. This data was collected using the Nab apparatus and are presented in the article "First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics." This data publication includes CSV (comma-separated values) files which are used to generate Figures 3 - 11 in the linked journal article.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Second Target Station Project (STS) Steerable Optic Design & Testing Report

Multiple neutron scattering instrument concepts for the Spallation Neutron Source's Second Target Station (STS) incorporate advanced neutron optic designs which incorporate discrete mirrors rather than continuous neutron guides that were the standard for instruments in the First Target Station. These mirrors can be a few to several meters in length and must be stably supported and aligned as a single optic. In addition, due to the length of the STS instruments and the small size of the STS neutron beams, installation and alignment at the micron level of precision will be required, which is beyond the ability of today's survey & alignment technology. Thus, a means of remotely adjusting these mirrors with single digit micron resolution is needed. A Steerable Optic System was designed to provide the precision and resolution required to support and manipulate these large, heavy optics under beamline shielding. A mockup was developed to demonstrate and validate this system for use in neutron optic applications, and this document describes the design and testing results of that mockup.

43 PARTICLE ACCELERATORS↗