Search NASA⌕ Search

SEARCH · Search NASA

Results for “operational controller loops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Control Strategy for Improving Resiliency of an DC Fast Charging EV System

As DC fast charging electric vehicle (EV) infrastructure continues to expand, potential challenges loom. One issue is the potential for EV charger outages due to electrical grid voltage transients. Today, EV chargers are expected to disconnect under a severe voltage sag (below 70%) which reduces electric vehicle charging infrastructure resilience. This work proposes a droop-control solution to ride-through voltage sags and maintain operation. The control solution is presented in a controller hardware in the loop platform.

Starke, Michael↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transmission Data-Driven User-Defined Model for Inverter-based and Conventional Power Plants

Recent events in Odessa [1], [2] have shed light on the complexities of integrating large Inverter-Based Resource (IBR) plants with the transmission system, prompting NERC to stress continuous performance monitoring by transmission operators. Challenges such as plant control updates, IBR model revisions, Phase-locked loop loss of synchronism, and protection events have been identified, underscoring the need for enhanced monitoring protocols by regulatory bodies. The recent FERC 901 order underscores the importance of accurate data exchange regarding IBRs for reliability studies. However, limited access to IBR plant-related data hampers effective decision-making for transmission operators (TOP). This paper proposes a method for constructing data-driven User-Defined dynamic Models (UDM) for power plants for validating multiple-event data using field measurements from interconnection bus locations. The problem is formulated as a power plant model identification problem and a multi-task learning approach under partial input observability assumptions is proposed in this work. This approach aims to predict aggregated responses of conventional and IBR power plants during various dynamic physical events which is useful for planning studies under diverse disturbance conditions. Ultimately, this methodology emphasizes the importance of plant visibility to operators in addressing power system challenges, facilitating improved planning and operational studies.

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

National Security Programs - Cyber: MMAREJBLIGE – Modular Multi Agent Grid Emulation for Joined Breakdowns in Linked Generative Emulations - 23-0644

Modular Multi Agent Grid Emulations for Joined Breakdowns in Linked Generative Emulations (MMAREJBLIGE) introduces an agent-based modeling framework into real-time cyber-physical emulation to achieve a context-aware environment that introduces operator/attacker/external-condition variability to improve emulation fidelity and testing rigor. We detail our agent framework design, internal communication via message passing, and time synchronization, as well as the individual components of the system. We include a brief analysis of several scenarios run on a real-time, hardware-in-the-loop, Industrial Control Systems (ICS) test-bed which include normal operation, physical disruption, disruption with mitigation, and disruption with mitigation during a cyber denial-of-service (DOS) attack.

42 ENGINEERING↗

Stellar interferometer for figure sensing of orbiting astronomical telescopes

An interferometric device designed to be located in the focal plane of a large astronomical telescope is presented. The prime application is for the forthcoming large space telescope. The device is to perform interferometry on the optical wavefront arising from a single star after it has propagated through the telescope. The concept of a focal plane figure sensor has been experimentally verified by fabricating and testing an operating laboratory breadboard figure sensor. A set of linear independent control equations are derived that define the operations for utilizing a focal plane figure sensor in the control loops for the positioning of the secondary mirror and for the active control of the primary mirror optical figure. A number of scientific experiments that could be performed with the interferometer are also briefly discussed.

Peters, W. N.↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high-definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit of the ammonia leak were the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Darnell Cowan↗

Implementation of Field-Oriented Control in Joint Actuator Electronics for Satellite-Servicing Robotics

NASA’s OSAM-1 (On-orbit Servicing, Assembly, and Manufacturing 1) is a robotic spacecraft designed to extend the life of a satellite. Launching in 2026, the OSAM-1 servicer will use a robotic arm to grasp, refuel, and relocate Landsat 7. In order to accomplish the various servicing operations, including the critical auto-grapple capturing operation, the robot arm uses active compliance and visual servo control loops. These sophisticated control algorithms are enabled by the high performance Joint Control Boards (JCBs). At the core of the robot arm control architecture, the JCBs employ field-oriented control (FOC) to accurately commutate and efficiently control joint actuator torque. FOC offers numerous benefits over other current control methods, allowing the JCBs to achieve the high bandwidth and performance required by the outer control loops. As an added benefit, a torque feed-forward term allows the FOC loop to simulate microgravity actuator performance during ground testing. In this paper, a FOC implementation for space robotics applications and an end-to-end actuator calibration process are discussed.

Sam Zhao↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters: Preprint

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetrations of grid-forming inverters has not been thoroughly studied to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with grid-forming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the micro-WECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with grid-forming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL CGI and PHIL Platform for Validation of Multi-Technology Energy Systems at Scale

The presentation is an update on National Renewable Energy Laboratory Flatirons Campus' capabilities around multi-megawatt grid simulation and power hardware-in-the-loop. Recent improvements in operational and dynamic range of existing 7MVA Controllable Grid Interface (CGI) are described together with improvements in site-wide automation and data acquisition systems. In later part of presentation, a second 19.9MVA CGI that is currently under development is introduced. Its features are described further explaining future site's capabilities.

acquisition↗

Understanding the Space Shuttle Main Engine Hydraulic Actuation System and Reviewing Its Evolution

The complex engine start and thrust control requirements of the Space Shuttle Main Engine (SSME) require unique valve, actuator and control system hardware. The Hydraulic Actuation System (HAS) was designed, developed, and now operates to meet tight engine control requirement limits to assure safe, reliable and correct engine thrust at all times. The actuator is designed to be fail safe and fail operate in the areas where redundancy is important. The HAS has an additional pneumatic operating capability that insures a safe sequential closure of all actuators and propellant valves in the event of the loss of hydraulic system pressure or loss of electrical closed loop control of the actuator. The objective of this paper is to provide a complete description of the actuator s internal operating system, along with its interaction with all SSME system interfaces. Additionally the paper addresses the challenges, problems identified, and corrected, and lessons learned, during the course of the almost 35 years of engine operation.

McWade, Robert J.↗

An Object-Oriented Graphical User Interface for a Reusable Rocket Engine Intelligent Control System

An intelligent control system for reusable rocket engines under development at NASA Lewis Research Center requires a graphical user interface to allow observation of the closed-loop system in operation. The simulation testbed consists of a real-time engine simulation computer, a controls computer, and several auxiliary computers for diagnostics and coordination. The system is set up so that the simulation computer could be replaced by the real engine and the change would be transparent to the control system. Because of the hard real-time requirement of the control computer, putting a graphical user interface on it was not an option. Thus, a separate computer used strictly for the graphical user interface was warranted. An object-oriented LISP-based graphical user interface has been developed on a Texas Instruments Explorer 2+ to indicate the condition of the engine to the observer through plots, animation, interactive graphics, and text.

Litt, Jonathan S.↗

Telerobotic research for in-space structural assembly and servicing

The paper reviews Langley's Telerobotic Technology Program and the recent and planned research in automated space assembly. Research areas include multiple manipulator coordination and control, automatic modes, evaluation of control modalities for teleoperated tasks, active sensing for world modeling and control, and architectures for distributed telerobotic systems. Studies of master/slave teleoperators performing representative space tasks showed that current teleoperator systems can be used to accomplish remote space operations. These studies also identified that research is required to improve the systems to reduce operator workload and task completion time. Closed-loop noncontact and contact sensor based control for automatic acquisition, positioning, and active compliance have been developed. A control structure for multiple manipulator coordination and control with manual, shared, and automatic modes performing space type tasks is being evaluated.

Meintel, Alfred J., Jr.↗

Building ControlScore: Research Laboratory Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore tool which captures operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trajectory Assessment and Modification Tools for Next Generation Air Traffic Management Operations

This paper reviews three Next Generation Air Transportation System (NextGen) based high fidelity air traffic control human-in-the-loop (HITL) simulations, with a focus on the expected requirement of enhanced automated trajectory assessment and modification tools to support future air traffic flow management (ATFM) planning positions. The simulations were conducted at the National Aeronautics and Space Administration (NASA) Ames Research Centers Airspace Operations Laboratory (AOL) in 2009 and 2010. The test airspace for all three simulations assumed the mid-term NextGenEn-Route high altitude environment utilizing high altitude sectors from the Kansas City and Memphis Air Route Traffic Control Centers. Trajectory assessment, modification and coordination decision support tools were developed at the AOL in order to perform future ATFM tasks. Overall tool usage results and user acceptability ratings were collected across three areas of NextGen operatoins to evaluate the tools. In addition to the usefulness and usability feedback, feasibility issues, benefits, and future requirements were also addressed. Overall, the tool sets were rated very useful and usable, and many elements of the tools received high scores and were used frequently and successfully. Tool utilization results in all three HITLs showed both user and system benefits including better airspace throughput, reduced controller workload, and highly effective communication protocols in both full Data Comm and mixed-equipage environments.

Brasil, Connie↗

Thermal Energy Distribution System (TEDS) Operating Modes and Control Strategies

A Thermal Energy Delivery System was constructed at the Idaho National Laboratory for demonstrating distribution of thermal energy to and from co-located systems sited in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL). DETAIL includes a flow loop simulating a pressurized water reactor, a high-temperature steam electrolysis unit and a thermal energy storage system. This report discusses the various operating modes and control strategies for enabling simultaneous, flexible and efficient transfer of heat from thermal energy sources to end users.

25 ENERGY STORAGE↗

Control Performance of General Electric Fuel and Torque Regulator Operating on T31-3 Turbine-Propeller Engine in Sea-Level Test Stand

A .General Electric fuel and torque regulator was tested in conjunction with a T31-3 turbine-propeller engine in the sea-level static test stand at the NACA Lewis laboratory. The engine and control were operated over the entire speed range: 11,000 rpm, nominal flight idle, to 13,000 rpm, full power. Steady-state and transient data were recorded and are presented with a description of the four control loops being used in the system. Results of this investigation indicated that single-lever control operation was satisfactory under conditions of test. Transient data presented showed that turbine-outlet temperature did overshoot maximum operating value on acceleration but that the time duration of overshoot did not exceed approximately 1 second. This temperature limiting resulted from a control on fuel flow as a function of engine speed. Speed and torque first reached their desired values 0.4 second from the time of change in power-setting lever position. Maximum speed overshoot was 3 percent.

Oppenheimer, Frank L.↗

Cooling system with automated seasonal freeze protection

An automated multi-fluid cooling system and method are provided for cooling an electronic component(s). The cooling system includes a coolant loop, a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling method with automated seasonal freeze protection

An automated multi-fluid cooling method is provided for cooling an electronic component(s). The method includes obtaining a coolant loop, and providing a coolant tank, multiple valves, and a controller. The coolant loop is at least partially exposed to outdoor ambient air temperature(s) during normal operation, and the coolant tank includes first and second reservoirs containing first and second fluids, respectively. The first fluid freezes at a lower temperature than the second, the second fluid has superior cooling properties compared with the first, and the two fluids are soluble. The multiple valves are controllable to selectively couple the first or second fluid into the coolant in the coolant loop, wherein the coolant includes at least the second fluid. The controller automatically controls the valves to vary first fluid concentration level in the coolant loop based on historical, current, or anticipated outdoor air ambient temperature(s) for a time of year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗