Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Improvements in optical metrology for high-performance variable-line-spacing x-ray gratings

Here, we discuss a project to develop a precision metrology system for variable-line-spacing x-ray gratings using interferometric microscopes. We are developing test standards and calibration techniques to measure and correct for geometrical distortion and blur, and data processing techniques to combine multiple measurements and measure line spacing with high accuracy.

Calibration methods↗

On the resolution of lenses made of a negative-index material

Resolution of the lenses made of a negative-index material is considered. It is shown that the super-resolution concept is untenable and the possibility of obtaining a perfect image on its own eventually contradicts Maxwell's equations in vacuum. It is also shown that known limitations of the diffraction theory on resolution of optical instruments hold true for the resolution of lenses of a negative-index material, in particular, the resolution of a Veselago lens. (nanogradient dielectric coatings and metamaterials)

36 MATERIALS SCIENCE↗

THE OPTIMAL GRAVITATIONAL LENS TELESCOPE

Given an observed gravitational lens mirage produced by a foreground deflector (cf. galaxy, quasar, cluster, ...), it is possible via numerical lens inversion to retrieve the real source image, taking full advantage of the magnifying power of the cosmic lens. This has been achieved in the past for several remarkable gravitational lens systems. Instead, we propose here to invert an observed multiply imaged source directly at the telescope using an ad hoc optical instrument which is described in the present paper. Compared to the previous method, this should allow one to detect fainter source features as well as to use such an optimal gravitational lens telescope to explore even fainter objects located behind and near the lens. Laboratory and numerical experiments illustrate this new approach.

79 ASTRONOMY AND ASTROPHYSICS↗

SUBSYSTEMS IN NEARBY SOLAR-TYPE WIDE BINARIES

We conducted a deep survey of resolved subsystems among wide binaries with solar-type components within 67 pc of the Sun. Images of 61 stars in the K and H bands were obtained with the Near-Infrared Coronagraphic Imager adaptive-optics instrument on the 8 m Gemini-South telescope. Our maximum detectable magnitude difference is about 5 mag and 7.8 mag at 0.''15 and 0.''9 separations, respectively. This enables a complete census of subsystems with stellar companions in the projected separation range from 5 to 100 AU. Out of seven such companions found in our sample, only one was previously known. We determine that the fraction of subsystems with projected separations above 5 AU is 0.12 {+-} 0.04 and that the distribution of their mass ratio is flat, with a power-law index of 0.2 {+-} 0.5. Comparing this with the properties of closer spectroscopic subsystems (separations below 1 AU), it appears that the mass-ratio distribution does not depend on the separation. The frequency of subsystems in the separation ranges below 1 AU and between 5 and 100 AU is similar, about 0.15. Unbiased statistics of multiplicity higher than 2, advanced by this work, provide constraints on star formation theory.

79 ASTRONOMY AND ASTROPHYSICS↗

The Gemini NICI planet-finding campaign: The companion detection pipeline

We present high-contrast image processing techniques used by the Gemini NICI Planet-Finding Campaign to detect faint companions to bright stars. The Near-Infrared Coronographic Imager (NICI) is an adaptive optics instrument installed on the 8 m Gemini South telescope, capable of angular and spectral difference imaging and specifically designed to image exoplanets. The Campaign data pipeline achieves median contrasts of 12.6 mag at 0.''5 and 14.4 mag at 1'' separation, for a sample of 45 stars (V = 4.3-13.9 mag) from the early phase of the campaign. We also present a novel approach to calculating contrast curves for companion detection based on 95% completeness in the recovery of artificial companions injected into the raw data, while accounting for the false-positive rate. We use this technique to select the image processing algorithms that are more successful at recovering faint simulated point sources. We compare our pipeline to the performance of the Locally Optimized Combination of Images (LOCI) algorithm for NICI data and do not find significant improvement with LOCI.

79 ASTRONOMY AND ASTROPHYSICS↗

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences↗

Need for LWR metrology standardization: the imec roughness protocol

© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). As semiconductor technology keeps moving forward, undeterred by the many challenges ahead, one specific deliverable is capturing the attention of many experts in the field: line width roughness (LWR) specifications are expected to be <2 nm in the near term, and to drop below 1 nm in just a few years. This is a daunting challenge and engineers throughout the industry are trying to meet these targets using every means at their disposal. However, although current efforts are surely admirable, we believe they are not enough. The fact is that a specification has a meaning only if there is an agreed methodology to verify if the criterion is met or not. Such standardization is critical in any field of science and technology and the question that we need to ask ourselves today is whether we have a standardized LWR metrology or not. In other words, if a single reference sample were provided, would everyone measuring it get reasonably comparable results? We came to realize that this is not the case and that the observed spread in the results throughout the industry is quite large. In our opinion, this makes the comparison of LWR data among institutions, or to a specification, very difficult. We report the spread of measured LWR data across the semiconductor industry. We investigate the impact of image acquisition, measurement algorithm, and frequency analysis parameters on LWR metrology. We review critically some of the International Technology Roadmap for Semiconductors (ITRS) metrology guidelines [such as measurement box length >2 μm and the need to correct for scanning electron microscope (SEM) noise]. We compare the SEM roughness results to AFM measurements. Finally, we propose a standardized LWR measurement protocol - the imec roughness protocol - intended to ensure that every time LWR measurements are compared (from various sources or to specifications), the comparison is sensible and sound. We deeply believe that the industry is at a point where it is imperative to guarantee that when talking about a critical parameter such as LWR, everyone speaks the same language, which is not currently the case.

Lorusso, Gian Francesco↗

Relative importance of various stochastic terms and EUV patterning

© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). An error propagation stochastic model is described and used to study the impact of both photon and photoresist material sources of line-width roughness (LWR). Based on typical chemically amplified resist parameters, material sources of LWR are shown to be of equal importance to photon sources. Of the material sources, quencher is shown to be the most important input noise term. The results show that it is not the relative quencher noise that ultimately matters but rather the absolute quencher noise relative to the mean produced acid count. The results also show that chemical yield is critical and that benefiting from increased absorptivity also requires the chemical yield to be maintained.

Naulleau, Patrick↗

Reconstructing the three-dimensional latent image of extreme ultraviolet resists with resonant soft x-ray scattering

© 2019 Society of Photo-Optical Instrumentation Engineers (SPIE). Extreme ultraviolet (EUV) lithography is one of the most promising printing techniques for high-volume semiconductor manufacturing at the 14-nm half-pitch device node and beyond. However, key challenges around EUV photoresist materials, such as the exposure-dose sensitivity or the line-width roughness, continue to impede its full adoption into industrial nanofab facilities. Metrology tools are required to address these challenges by helping to assess the impact of the EUV materials' properties and processing conditions along different steps of the nanofabrication process. We apply the resonant soft x-ray scattering (RSoXS) technique to gain insights into the structure of patterned EUV resists before the development step takes place. By using energies around the carbon K-edge to take advantage of small differences in chemistry, the electronic density contrast between the exposed and unexposed regions of the resists could be enhanced in order to image the patterns with subnanometer precision. Critical-dimension grazing-incidence small-angle x-ray scattering is then performed at energies where the contrast is maximized, enabling the reconstruction of the three-dimensional shape of the latent image. We demonstrate the potential of RSoXS to provide a high-resolution height-sensitive profile of patterned EUV resists, which will help in quantifying the evolution of critical features, such as the line-edge roughness, at a key step of the nanofabrication process.

Freychet, Guillaume↗

Quantum-engineered interband cascade photovoltaic devices

Quantum-engineered multiple stage photovoltaic (PV) devices are explored based on InAs/GaSb/AlSb interband cascade (IC) structures. These ICPV devices employ multiple discrete absorbers that are connected in series by widebandgap unipolar barriers using type-II heterostructure interfaces for facilitating carrier transport between cascade stages similar to IC lasers. The discrete architecture is beneficial for improving the collection efficiency and for spectral splitting by utilizing absorbers with different bandgaps. As such, the photo-voltages from each individual cascade stage in an ICPV device add together, creating a high overall open-circuit voltage, similar to conventional multi-junction tandem solar cells. Furthermore, photo-generated carriers can be collected with nearly 100% efficiency in each stage. This is because the carriers travel over only a single cascade stage, designed to be shorter than a typical diffusion length. The approach is of significant importance for operation at high temperatures where the diffusion length is reduced. Here, we will present our recent progress in the study of ICPV devices, which includes the demonstration of ICPV devices at room temperature and above with narrow bandgaps (e.g. 0.23 eV) and high open-circuit voltages. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

14 SOLAR ENERGY↗

Reliable automatic alignment of tomographic projection data by passive auto-focus

Purpose: The authors present a robust algorithm that removes the blurring and double-edge artifacts in high-resolution computed tomography (CT) images that are caused by misaligned scanner components. This alleviates the time-consuming process of physically aligning hardware, which is of particular benefit if components are moved or swapped frequently. Methods: The proposed method uses the experimental data itself for calibration. A parameterized model of the scanner geometry is constructed and the parameters are varied until the sharpest 3D reconstruction is found. The concept is similar to passive auto-focus algorithms of digital optical instruments. The parameters are used to remap the projection data from the physical detector to a virtual aligned detector. This is followed by a standard reconstruction algorithm, namely the Feldkamp algorithm. Feldkamp et al.[J. Opt. Soc. Am. A 1, 612-619 (1984)]. Results: An example implementation is given for a rabbit liver specimen that was collected with a circular trajectory. The optimal parameters were determined in less computation time than that for a full reconstruction. The example serves to demonstrate that (a) sharpness is an appropriate measure for projection alignment, (b) our parameterization is sufficient to characterize misalignments for cone-beam CT, and (c) the procedure determines parameter values with sufficient precision to remove the associated artifacts. Conclusions: The algorithm is fully tested and implemented for regular use at The Australian National University micro-CT facility for both circular and helical trajectories. It can in principle be applied to more general imaging geometries and modalities. It is as robust as manual alignment but more precise since we have quantified the effect of misalignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smoothing tool design and performance during subaperture glass polishing

During subaperture tool grinding and polishing, overlaps of the tool influence function can result in undesirable mid-spatial frequency (MSF) errors in the form of surface ripples, which are often corrected using a smoothing polishing step. Here, in this study, flat multi-layer smoothing polishing tools are designed and tested to simultaneously (1) reduce or remove MSF errors, (2) minimize surface figure degradation, and (3) maximize the material removal rate. A time-dependent convergence model in which spatial material removal varies with a workpiece-tool height mismatch, combined with a finite element mechanical analysis to determine the interface contact pressure distribution, was developed to evaluate various smoothing tool designs as a function of tool material properties, thicknesses, pad textures, and displacements. An improvement in smoothing tool performance is achieved when the gap pressure constant, $\overline{h}$ (which describes the inverse rate at which the pressure drops with a workpiece-tool height mismatch), is minimized for smaller spatial scale length surface features (namely, MSF errors) and maximized for large spatial scale length features (i.e., surface figure). Five specific smoothing tool designs were experimentally evaluated. A two-layer smoothing tool using a thin, grooved IC1000 polyurethane pad (with a high elastic modulus, E pad =360 MPa ), thicker blue foam (with an intermediate modulus, E foam =5.3 MPa ) underlayer, and an optimized displacement (d t =1 mm ) provided the best overall performance (namely, high MSF error convergence, minimal surface figure degradation, and high material removal rate).

47 OTHER INSTRUMENTATION↗

X-ray diffraction effect from surface acoustic waves traveling on a deposited multilayer

We investigate the x-ray diffraction effects from surface acoustic waves (SAW) traveling along a multilayer. The diffraction intensity distribution depends on the incidence angle and the multilayer SAW (MLSAW) amplitude. Particularly, a small departure deviating from the Bragg incidence angle at a certain amplitude will produce a larger variation of the intensity distribution. This shows that the diffraction intensity from MLSAW has an extremely high sensitivity to the Bragg incidence angle, which is different from a SAW traveling along a solid surface without deposited layers. By carefully analyzing the relationship between the intensity distribution I and the incidence angle {theta}, the corresponding analytic expression of the intensity distribution is theoretically derived. Our theoretical prediction is in great agreement with the experimental results previously obtained. A theoretical model that can be applied to study the x-ray diffraction effect from MLSAW is developed. The extremely high sensitivity to the Bragg angle will help us in acousto-optic instrument research with MLSAW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New method for the determination of photoabsorption from transmittance measurements in the extreme ultraviolet

We have developed a new method for the determination of photoabsorption at extreme ultraviolet wavelengths longer than 20 nm, where reliable refractive index values are sparse or non-existent. Our method overcomes the obstacle of multiple reflections that occur inside thin films in this spectral range, which up until now has prevented the accurate determination of photoabsorption from transmittance measurements. We have derived a mathematical expression that is independent of internal reflection amplitudes, while taking advantage of the transmittance oscillations stemming from such reflections. The method is validated on measurements of aluminum thin films. This advance will enable accurate refractive index values for many important materials for optical instrumentation, thus facilitating high-priority research on topics including coherent light sources, planetary and solar physics, and semiconductor manufacturing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Computer Vision Techniques Used to Monitor the Alignment of Cavities and Solenoids in the PIP-II Prototype SSR1 Cryomodule

The alignment of the SRF PIP-II string components is studied as the acceptable beam deflection, offset and defocusing, which may otherwise cause beam loss. Simulations and measurements established that the maximum deviation of the beam pipe from the reference orbit should not exceed a small fraction of the beam aperture. To observe the translations and rotations of each single component within the cryomodule, optical instruments (H-BCAM) surveying highly reflective targets, installed in the internal assembly of the module were used. The alignment monitoring concept for the PIP II SSR1 prototype cryomodule, along with relevant measurements of the components’ position monitoring during coldmass cooldown is presented in this contribution. This development paves the way to new computer vision applications in the field of cryomodule assemblies in cleanroom environment, in which robotically-assisted operations have the potential to dramatically reduce the risk of chemical and particulate contamination.

43 PARTICLE ACCELERATORS↗

Hyperspectral Raman imaging using a spatial heterodyne spectrometer (SHS)

Savannah River National Laboratory, and the larger community, has limited chemical-specific imaging capabilities, which would be beneficial for remote detection of threat chemicals or use in inaccessible and harsh environments, as well as in-line process monitoring. Chemical imaging technology would support multiple directorates through stand-off detection of chemicals (National Security), and imaging of chemical distributions in a process (Nuclear Materials Management, Clean Energy) and in waste tanks (Environmental Stewardship). Chemical-specific imaging is underdeveloped due to issues of sensitivity, stable alignment and calibration, and ease of operation associated with most optical instruments. The project objective is to develop a novel, rugged, highly sensitive spectrometer to support real-time, chemically specific imaging using hyperspectral Raman spectroscopy. Raman spectroscopic analysis will provide chemical specificity and using a spatial heterodyne spectrometer (SHS) will increase the sensitivity due to the high light throughput design. The SHS design does not require moving parts allowing for a very stable system, reducing alignment and calibration issues. The instrument will be assembled and initially applied to Raman gas detection of the Saltstone disposal unit headspace gas concentrations. Raman gas analysis is the most impacted by sensitivity issues and will be used to demonstrate the increased light collection capability of the SHS over a conventional dispersive spectrometer. The system will be later modified to image spectral information in a spatial domain to provide information on the spatial distribution of a sample scene.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expanded Capabilities and Opportunities for Virtual Beamline Code

In the 25 years since LLNL broke ground on the National Ignition Facility (NIF) - a cornerstone of the National Nuclear Security Administration’s Stockpile Stewardship Program - the NIF and Photon Science (NIF&PS) Directorate has steadily pushed the boundaries of laser physics, nonlinear optics, and photonics in service of inertial confinement fusion experiments, and advanced photon sources development. Beyond the 192 beamlines of the primary laser facility with its world-record energy and fusion yields, NIF&PS capabilities have expanded to include chirped-pulse amplification, kilojoule petawatt-class short-pulse systems to generate hard x-ray radiographic probes, high-average power lasers as secondary sources for generation or wake field particle acceleration along directed energy applications, and other scientific pursuits. The Computing Directorate partners with NIF&PS on numerous projects and technologies from diagnostic measurements and high performance control systems to data analysis, information technology infrastructure, and scientific simulation code development. “This strong collaboration enables cutting-edge science, particularly with regard to physics-based modeling and simulation,” says physicist Jean-Michel Di Nicola. One crucial capability for NIF&PS is the Virtual Beamline (VBL) laser simulation code. It can model all the major laser physics and technology involved in the design optimization, commissioning, and operations of advanced laser architectures from tabletop to NIF-scale. VBL provides researchers with high-fidelity models and high-resolution calculations of laser performance predictions—including for the entire NIF laser system, the Advanced Radiographic Capability, parts of the High Repetition-Rate Advanced Petawatt Laser System laser delivered to the Czech Republic, and the Optical Science Laser. After more than two decades of experimentally verified physics and computing enhancements, this unique workhorse code is wrapping up another major milestone: migration from Java to C++ with a flurry of user interface and optimization features, as well as laser physics and high-resolution enhancements thanks to parallel execution on Livermore Computing platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗