Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Focus determination for the James Webb Space Telescope Science Instruments: A Survey of Methods

The James Webb Space Telescope (JWST) is a segmented deployable telescope that will require on-orbit alignment using the Near Infrared Camera as a wavefront sensor. The telescope will be aligned by adjusting seven degrees of freedom on each of 18 primary mirror segments and five degrees of freedom on the secondary mirror to optimize the performance of the telescope and camera at a wavelength of 2 microns. With the completion of these adjustments, the telescope focus is set and the optical performance of each of the other science instruments should then be optimal without making further telescope focus adjustments for each individual instrument. This alignment approach requires confocality of the instruments after integration and alignment to the composite metering structure, which will be verified during instrument level testing at Goddard Space Flight Center with a telescope optical simulator. In this paper, we present the results from a study of several analytical approaches to determine the focus for each instrument. The goal of the study is to compare the accuracies obtained for each method, and to select the most feasible for use during optical testing.

Davila, Pamela S.↗

Hubble Space Telescope overview

A general overview of the performance and current status of the Hubble Space Telescope is presented. Most key spacecraft subsystems are operating well, equaling or exceeding specifications. Spacecraft thermal properties, power, and communications, are superb. The only spacecraft subsystem to have failed, a gyro, is briefly discussed. All science instruments are functioning extremely well and are returning valuable scientific data. The two significant problems effecting the Hubble Space Telescope science return, the pointing jitter produced by thermally induced bending of the solar array wings and the optical telescope assembly spherical aberration, are discussed and plans to repair both problems are mentioned. The possible restoration of full optical performance of the axial scientific instruments through the use of the Corrective Optics Space Telescope Axial Replacement, currently under study for the 1993 servicing mission, is discussed. In addition, an overview of the scientific performance of the Hubble Space Telescope is presented.

Polidan, Ronald S.↗

International Test Program for Synergistic Atomic Oxygen and VUV Exposure of Spacecraft Materials

Spacecraft in low Earth orbit (LEO) are subject to degradation in thermal and optical performance of components and materials through interaction with atomic oxygen and vacuum ultraviolet radiation which are predominant in LEO. Due to the importance of LEO durability and performance to manufacturers and users, an international test program for assessing the durability of spacecraft materials and components was initiated. Initial tests consisted of exposure of samples representing a variety of thermal control paints and multilayer insulation materials that have been used in space. Materials donated from various international sources were tested alongside a material whose performance is well known such as Teflon FEP or Kapton H for multilayer insulation, or Z-93-P for white thermal control paints. The optical, thermal or mass loss data generated during the test was then provided to the participating material supplier. Data was not published unless the participant donating the material consented to publication. This paper presents a description of the types of tests and facilities that have been used for the test program as well as some examples of data that have been generated. The test program is intended to give spacecraft builders and users a better understanding of degradation processes and effects to enable improved prediction of spacecraft performance.

Rutledge, Sharon↗

Optical Navigation Algorithm Performance

There is a wide variety of optical navigation (OpNav) techniques that can be used to extract observables from images of natural bodies. Each of these techniques has a number of strengths and weaknesses and domains where they are most applicable. In this paper, we compare the performance of some of the most commonly used OpNav techniques across a variety of orbital regimes and a variety of body types through the use of synthetic images. Specifically, we consider the techniques of analytic model fitting, phase corrected moment estimation, limb-scanning, ellipsoid matching, and cross correlation using synthetic images of a tri-axial ellipsoid, the asteroid Bennu, and the comet 67P/Churyumov-Gerasimenko. For each technique, regime, and body, we examine the overall accuracy and the type of information available. The resulting information provides a useful tool for understanding which techniques are best suited for a given image, as well as for understanding the relative performance of each technique.

Wright, Cinnamon A.↗

Overview of the Optomechanical Design of the LUVOIR Instruments

The Large Ultraviolet/Optical/Infrared Surveyor (LUVOIR) is a space telescope being submitted for review to the 2020 Decadal Survey in Astronomy and Astrophysics. Its science objectives include both direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of planet, star, and galaxy formation, the transfer of matter between different galaxies, and the remote sensing of objects within the Solar System. Two architectures have been designed: a 15 m diameter on-axis telescope (LUVOIR-A) and an 8 m off-axis telescope (LUVOIR-B). This paper discusses the opto-mechanical design of the three LUVOIR instruments: the High Definition Imager (HDI), the LUVOIR UV Multi-object Spectrograph (LUMOS), and the Extreme Coronagraph for Living Planetary Systems (ECLIPS). For both the LUVOIR-A and LUVOIR-B variants of each instrument, optical design specifications are presented including first-order constraints, packaging requirements, and optical performance metrics. These factors are used to illustrate the final design of each instrument and LUVOIR as a whole. In addition to the optical designs, mechanical models are presented for each instrument showing the optical mounts, mechanisms, support structure, etc.

Decadal Study↗

The Measurement of MTFs in X-ray Microscopy Using Diffractograms

A novel method to characterize the optical performance of a high-resolution transmission x-ray microscope is presented. It makes use of test patterns that consist of random arrays of sub-resolution holes in a thin metal film, and so approximate to white-noise input signals for the microscope. The test patterns have been fabricated by electron-beam lithography at length scales appropriate for the resolution available in x-ray microscopy, so that diffractograms produced from the image data can be directly interpreted in terms of the contrast transfer function of the optical system. Results of this method are shown for both brightfield and differential phase contrast imaging.

07 ISOTOPE AND RADIATION SOURCES↗

Compact Simultaneous-beam Optical Strain Measurement System, Phase 5

Recent advances on the laser speckle strain measurement system under development at NASA Lewis Research Center have resulted in a compact, easy-to-use measurement package having many performance improvements over previous systems. NASA has developed this high performance optical strain measurement system for high temperature material testing applications. The system is based on I. Yamaguchi's two-beam speckle-shift strain measurement theory, and uses a new optical design that allows simultaneous recording of laser speckle patterns. This design greatly improves system response over previous implementations of the two-beam speckle-shift technique. The degree of immunity to transient rigid body motions is no longer dependent on the data transfer rate. The system automatically calculates surface strains at a frequency of about 5 Hz using a high speed digital signal processor in a personal computer. This system is fully automated, and can be operated remotely. This report describes the designs and methods used by the system, and shows low temperature strain test results obtained from small diameter tungsten-rhenium and palladium-chrome wires.

Lant, Christian T.↗

Lightfield Directing Array use for Augmented Reality

Lawrence Livermore National Laboratory has developed the Lightfield Directing Array (LDA), a highspeed, large range, precision micromirror array intended to provide combined beam-steering and adaptive optics on a single chip. Present MEMS devices are limited by their flexure design to low range-bandwidth and offer poor stability, so have seen limited use in high performance optics. We have solved this with advanced flexure and actuator design which can offer a >10x higher range-bandwidth product with closed loop integrated sensing for precision operation. The LDA provides new levels of performance for MEMS steered Augmented Reality (AR) driven imaging systems, including stable images, repeatable scanning, faster refresh rates, adaptive resolution and adjustable depth of focus.

47 OTHER INSTRUMENTATION↗

3D and Multimodal X‐Ray Microscopy Reveals the Impact of Voids in CIGS Solar Cells

Small voids in the absorber layer of thin-film solar cells are generally suspected to impair photovoltaic performance. They have been studied on Cu(In,Ga)Se 2 cells with conventional laboratory techniques, albeit limited to surface characterization and often affected by sample-preparation artifacts. Here, synchrotron imaging is performed on a fully operational as-deposited solar cell containing a few tens of voids. By measuring operando current and X-ray excited optical luminescence, the local electrical and optical performance in the proximity of the voids are estimated, and via ptychographic tomography, the depth in the absorber of the voids is quantified. Besides, the complex network of material-deficit structures between the absorber and the top electrode is highlighted. Despite certain local impairments, the massive presence of voids in the absorber suggests they only have a limited detrimental impact on performance.

14 SOLAR ENERGY↗

Cryocooled terahertz photoconductive detector system with background-limited performance in 1.5–4 THz frequency range

We describe a 4-K-cryocooled dual-band terahertz (THz) photoconductive detector system with background-limited performance. The detector system comprises two THz photoconductive detectors covering a response in a wide frequency range from 1.5 to 4 THz, low noise amplifiers, optical low-pass filters to eliminate input radiation of higher frequencies, and a mechanical 4 K Gifford-McMahon refrigerator that provides practical and convenient operation without a liquid He container. The electrical and optical performances of the THz detector system were evaluated at a detector temperature of 4 K under 300 K background radiation. We proved that the detector system can achieve background-limited noise-equivalent-power on the order of 10{sup −14} W/Hz{sup 1/2} in the frequency range from 1.5 to 4 THz even if the vibration noise of the mechanical refrigerator is present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bright trion emission from semiconductor nanoplatelets

The trion, a quasiparticle comprising one exciton and an additional charge carrier, offers unique opportunities for generating spin-photon interfaces that can be used in developing quantum networks. Trions are also actively sought after for integrated optoelectronic devices including photovoltaics, photodetectors, and spintronics. However, formation of trions in strongly confined low-dimensional materials is often deemed detrimental. This is because trion emission in such materials is typically prohibited due to the predominant nonradiative Auger recombination processes. Semiconductor nanoplatelets with their strong confinement in the thickness direction and extended lateral geometries exhibit large exciton coherence sizes and reduced carrier-carrier interactions that may enable unprecedented trion properties. In this paper, we perform optical spectroscopic studies of individual CdSe nanoplatelets at cryogenic temperatures and observe bright trion emission with intensities comparable to that of neutral exciton emission. We perform carrier dynamics studies of the nanoplatelets and find that due to their extended lateral geometry, the fast radiative decay rate of the nanoplatelets at cryogenic temperatures is comparable to the inhibited Auger recombination rate, leading to the bright trion emission. Our tight-binding theory further reveals distinct size-tunable trion emission in the nanoplatelets that is advantageous for efficient trion emission. These properties make semiconductor nanoplatelets potential candidates as photon sources for optoelectronic and quantum logic devices.

36 MATERIALS SCIENCE↗

A New Compton-thick AGN in Our Cosmic Backyard: Unveiling the Buried Nucleus in NGC 1448 with NuSTAR

NGC 1448 is one of the nearest luminous galaxies (L {sub 8–1000μm} > 10{sup 9} L {sub ⊙}) to ours (z = 0.00390), and yet the active galactic nucleus (AGN) it hosts was only recently discovered, in 2009. In this paper, we present an analysis of the nuclear source across three wavebands: mid-infrared (MIR) continuum, optical, and X-rays. We observed the source with the Nuclear Spectroscopic Telescope Array (NuSTAR), and combined these data with archival Chandra data to perform broadband X-ray spectral fitting (≈0.5–40 keV) of the AGN for the first time. Our X-ray spectral analysis reveals that the AGN is buried under a Compton-thick (CT) column of obscuring gas along our line of sight, with a column density of N {sub H}(los) ≳ 2.5 × 10{sup 24} cm{sup −2}. The best-fitting torus models measured an intrinsic 2–10 keV luminosity of L {sub 2−10,int} = (3.5–7.6) × 10{sup 40} erg s{sup −1}, making NGC 1448 one of the lowest luminosity CTAGNs known. In addition to the NuSTAR observation, we also performed optical spectroscopy for the nucleus in this edge-on galaxy using the European Southern Observatory New Technology Telescope. We re-classify the optical nuclear spectrum as a Seyfert on the basis of the Baldwin–Philips–Terlevich diagnostic diagrams, thus identifying the AGN at optical wavelengths for the first time. We also present high spatial resolution MIR observations of NGC 1448 with Gemini/T-ReCS, in which a compact nucleus is clearly detected. The absorption-corrected 2–10 keV luminosity measured from our X-ray spectral analysis agrees with that predicted from the optical [O iii]λ5007 Å emission line and the MIR 12 μm continuum, further supporting the CT nature of the AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Pupil configurations for an interferometric TPF mission

The primary goal of the proposed Terrestrial Planet Finder mission is the direct detection of radiation from potential terrestrial planets orbiting around nearby stars. However, the faintness of the expected signals leads to very stringent technical requirements on the optical performance. As a result, both of the candidate approaches currently under active development by the TPF project, infrared nulling interferometry with separated aperture telescopes, and optical coronagraphy with a large singl aperture telescope, require complex optical systems which push the state of the art.

TPF interferometry Terrestrial Planet Finder↗

A New Compton-Thick AGN in Our Cosmic Backyard: Unveiling the Buried Nucleus in NGC 1448 with NuSTAR

NGC 1448 is one of the nearest luminous galaxies [L(sub 8) - 1000 micrometers is greater than 10(exp. 9) Solar Luminosity] to ours (z = 0.00390), and yet the active galactic nucleus (AGN) it hosts was only recently discovered, in 2009. In this paper, we present an analysis of the nuclear source across three wavebands: mid-infrared (MIR) continuum, optical, and X-rays. We observed the source with the Nuclear Spectroscopic Telescope Array (NuSTAR), and combined these data with archival Chandra data to perform broadband X-ray spectral fitting ( approx. equals 0.5 - 40 keV) of the AGN for the first time. Our X-ray spectral analysis reveals that the AGN is buried under a Compton-thick (CT) column of obscuring gas along our line of sight, with a column density of N(sub H)(los) approx. greater than 2.5 x 10(exp. 24) cm(exp. -2). The best-fitting torus models measured an intrinsic 2-10 keV luminosity of L(sub 2)-10,int = (3.5 - 7.6) x 10(exp. 40) erg s(exp. -1), making NGC 1448 one of the lowest luminosity CTAGNs known. In addition to the NuSTAR observation, we also performed optical spectroscopy for the nucleus in this edge-on galaxy using the European Southern Observatory New Technology Telescope. We reclassify the optical nuclear spectrum as a Seyfert on the basis of the Baldwin- Philips-Terlevich diagnostic diagrams, thus identifying the AGN at optical wavelengths for the first time. We also present high spatial resolution MIR observations of NGC 1448 with Gemini/T-ReCS, in which a compact nucleus is clearly detected. The absorption-corrected 2-10 keV luminosity measured from our X-ray spectral analysis agrees with that predicted from the optical [O III] Lamda 5007 A emission line and the MIR 12 micrometer continuum, further supporting the CT nature ofthe AGN.

galaxies: active – galaxies: nuclei – techniqu↗

Cryogenic Performance of a Lightweight Silicon Carbide Mirror

Low cost, high performance lightweight Silicon Carbide (SiC) mirrors provide an alternative to Beryllium mirrors. A Trex Enterprises 0.25m diameter lightweight SiC mirror using its patented Chemical Vapor Composites (CVC) technology was evaluated for its optical performance. CVC SiC is chemically pure, thermally stable, and mechanically stiff. CVC technology yields higher growth rate than that of CVD SiC. NASA has funded lightweight optical materials technology development efforts involving SiC mirrors for future space based telescope programs. As part of these efforts, a Trex SiC was measured interferometrically from room temperature to 30 degrees Kelvin. This paper will discuss the test goals, the test instrumentation, test results, and lessons learned.

Eng, Ron↗

Cryogenic Performance of Trex SiC Mirror

Low cost, high performance lightweight Silicon Carbide (Sic) mirrors provide an alternative to Beryllium mirrors. A Trex Enterprises 0.25m diameter lightweight Sic mirror using its patented Chemical Vapor Composites (CVC) technology was evaluated for its optical performance. CVC Sic is chemically pure, thermally stable, and mechanically stiff. CVC technology yields higher growth rate than that of CVD Sic. NASA has funded lightweight optical materials technology development efforts involving Sic mirrors for future space based telescope programs. As part of these efforts, a Trex Sic was measured interferometrically from room temperature to 30 degrees Kelvin. This paper will discuss the test goals, the test instrumentation, test results, and lessons learned.

Foss, Colby↗

Low-Power Ion Thruster Development Status

An effort is on-going to examine scaling relationships and design criteria for ion propulsion systems, and to address the need for a light weight, low power, high specific impulse propulsion option for small spacecraft. An element of this activity is the development of a low-power (sub-0.5 kW) ion thruster. This development effort has led to the fabrication and preliminary performance assessment of an 8 cm prototype xenon ion thruster operating over an input power envelope of 0.1-0.3 kW. Efficiencies for the thruster vary from 0.31 at 1750 seconds specific impulse at 0.1 kW, to about 0.48 at 2700 seconds specific impulse and 0.3 kW input power. Discharge losses for the thruster over this power range varied from about 320-380 W/A down to about 220-250 W/A. Ion optics performance compare favorably to that obtained with 30 cm ion optics, when scaled for the difference in beam area. The neutralizer, fabricated using 3 mm hollow cathode technology, operated at keeper currents of about 0.2-0.3 A, at a xenon flow rate of about 0.06 mg/s, over the 0.1-0.3 kW thruster input power envelope.

Patterson, Michael J.↗

Cryogenic Refractive Index of Heraeus Homosil Glass

This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.34-3.16 microns and temperature range of 120-335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASAs Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a field-widened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitivity performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dn/dT) and dispersion relation (dn/d(lamda)) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in literature.

cryogenic↗