Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Phonons reveal coupled cholesterol-lipid dynamics in ternary membranes

Experimental studies of collective dynamics in lipid bilayers have been challenging due to the energy resolution required to observe these low-energy phonon-like modes. However, inelastic X-ray scattering (IXS) measurements — a technique for probing vibrations in soft and biological materials — are now possible with sub-meV resolution, permitting direct observation of low energy, phonon-like modes in lipid membranes. Here, in this study, IXS measurements with sub-meV energy resolution reveal a low-energy optic-like phonon mode at roughly 3 meV in the liquid-ordered (L o ) and liquid-disordered (L d ) phases of a ternary lipid mixture. This mode is only observed experimentally at momentum transfers greater than 5 nm -1 in the L o system. A similar gapped mode is also observed in all-atom molecular dynamics (MD) simulations of the same mixture, indicating that the simulations accurately represnt the fast, collective dynamics in the L o phase. It’s optical nature and the Q range of the gap together suggest that the observed mode is due to the coupled motion of cholesterol-lipid pairs, separated by several hydrocarbon chains within the membrane plane. Analysis of the simulations provide molecular insight into the origin of the mode in transient, nanoscale substructures of hexagonally packed hydrocarbon chains. This nanoscale hexagonal packing was previously reported based on molecular dynamics simulations and later by NMR measurements. Here, however, the integration of IXS and MD simulations identifies a new signature of the L o substructure in the collective lipid dynamics, thanks to the recent confluence of IXS sensitivity and MD simulation capabilities.

36 MATERIALS SCIENCE↗

Multi-species temperature and number density analysis of a laser-produced plasma using dual-comb spectroscopy

Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-beam X-ray ptychography using coded probes for rapid non-destructive high resolution imaging of extended samples

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

47 OTHER INSTRUMENTATION↗

Data Transfer for Multiple Sensor Networks Over a Broad Temperature Range

At extreme temperatures, cryogenic and over 300 C, few electronic components are available to support intelligent data transfer over a common, linear combining medium. This innovation allows many sensors to operate on the same wire bus (or on the same airwaves or optical channel: any linearly combining medium), transmitting simultaneously, but individually recoverable at a node in a cooler part of the test area. This innovation has been demonstrated using room-temperature silicon microcircuits as proxy. The microcircuits have analog functionality comparable to componentry designed using silicon carbide. Given a common, linearly combining medium, multiple sending units may transmit information simultaneously. A listening node, using various techniques, can pick out the signal from a single sender, if it has unique qualities, e.g. a voice. The problem being solved is commonly referred to as the cocktail party problem. The human brain uses the cocktail party effect when it is able to recognize and follow a single conversation in a party full of talkers and other noise sources. High-temperature sensors have been used in silicon carbide electronic oscillator circuits. The frequency of the oscillator changes as a function of the changes in the sensed parameter, such as pressure. This change is analogous to changes in the pitch of a person s voice. The output of this oscillator and many others may be superimposed onto a single medium. This medium may be the power lines supplying current to the sensors, a third wire dedicated to data transmission, the airwaves through radio transmission, an optical medium, etc. However, with nothing to distinguish the identities of each source that is, the source separation this system is useless. Using digital electronic functions, unique codes or patterns are created and used to modulate the output of the sensor.

Krasowski, Michael↗

An investigation to determine the producibility of a 3-D braider and bias direction weaving loom

The development of prototype machines for the production of generalized braid patterns is described. Mechanical operating principles and control strategies are presented for two prototype machines which were fabricated and evaluated. Both machines represent advances over current techniques for forming composite material preforms by enabling near ideal control of fiber orientation. Furthermore, they overcome both the lack of general control of produced fiber architectures and the complexity of other weaving processes that were produced for the same purpose. One prototype, the modified Farley braider, consists of an array of turntables which can be rotated 90 degrees and returned; hence, they can form tracks in the x and y axis. Yarn ends are transported about the surface formed by the turntables using motorized tractors. These tractors are controlled using an optical link with a control circuit and host computer. The tractors are powered through electrical contact with the turntables. The necessary relative motions are produced by a series of linear tractor moves combined with a sequence of turntable rotations. The movement of the tractors about the surface causes the yarns to produce the desired braiding pattern. The second device, the shuttle plate braider, consists of a braiding surface formed by an array of square elements, each separated from its neighbor by a gap. Beneath this surface lies a shuttle plate, which reciprocates first in one axis and then in the other. As this movement takes place, yarn carrying shuttles engage and disengage the plate by means of solenoid activated pins. By selective engagement and disengagement, the shuttles can move the yarn ends in any desired pattern, forming the desired braid. Control power, and control signals, are transmitted from the electronic interface circuit and host computer, via the braiding surface through electrical contact with the shuttles. Motive power is proved to the shuttles by motion of the shuttle plate, which is passively driven using pneumatic rams. Each shuttle is a simple device that uses only a solenoid to engage the plate and is a simple device that uses only a solenoid to engage the plate and is independently controllable. When compared with each other, the modified Farley braider has the advantage of speed, and the shuttle plate braider the advantage of mechanical control and simplicity.

Huey, Cecil O., Jr.↗

Curved grating fabrication techniques for concentric-circle grating, surface-emitting semiconductor lasers

We describe the fabrication and operational characteristics of a novel, surface-emitting semiconductor laser that makes use of a concentric-circle grating to both define its resonant cavity and to provide surface emission. A properly fabricated circular grating causes the laser to operate in radially inward- and outward-going circular waves in the waveguide, thus, introducing the circular symmetry needed for the laser to emit a beam with a circular cross-section. The basic circular-grating-resonator concept can be implemented in any materials system; an AlGaAs/GaAs graded-index, separate confinement heterostructure (GRINSCH), single-quantum-well (SQW) semiconductor laser, grown by molecular beam epitaxy (MBE), was used for the experiments discussed here. Each concentric-circle grating was fabricated on the surface of the AlGaAs/GaAs semiconductor laser. The circular pattern was first defined by electron-beam (e-beam) lithography in a layer of polymethylmethacrylate (PMMA) and subsequently etched into the semiconductor surface using chemically-assisted (chlorine) ion-beam etching (CAIBE). We consider issues that affect the fabrication and quality of the gratings. These issues include grating design requirements, data representation of the grating pattern, and e-beam scan method. We provide examples of how these techniques can be implemented and their impact on the resulting laser performance. A comparison is made of the results obtained using two fundamentally different electron-beam writing systems. Circular gratings with period lambda = 0.25 microns and overall diameters ranging from 80 microns to 500 microns were fabricated. We also report our successful demonstration of an optically pumped, concentric-circle grating, semiconductor laser that emits a beam with a far-field divergence angle that is less than one degree. The emission spectrum is quite narrow (less than 0.1 nm) and is centered at wavelength lambda = 0.8175 microns.

Jordan, Rebecca H.↗

Development of generalized 3-D braiding machines for composite preforms

The development of prototype braiding machines for the production of generalized braid patterns is described. Mechanical operating principles and control strategies are presented for two prototype machines which have been fabricated and evaluated. Both machines represent advances over current fabrication techniques for composite materials by enabling nearly ideal control of fiber orientations within preform structures. They permit optimum design of parts that might be subjected to complex loads or that have complex forms. Further, they overcome both the lack of general control of produced fiber architectures and the complexity of other weaving processes that have been proposed for the same purpose. One prototype, the Farley braider, consists of an array of turntables that can be made to oscillate in 90 degree steps. Yarn ends are transported about the surface formed by the turntables by motorized tractors which are controlled through an optical link with the turntables and powered through electrical contact with the turntables. The necessary relative motions are produced by a series of linear tractor moves combined with a series of turntable rotations. As the tractors move about, they weave the yarn ends into the desired pattern. The second device, the shuttle plate braider, consists of a braiding surface formed by an array of stationary square sections, each separated from its neighbors by a gap. A plate beneath this surface is caused to reciprocate in two perpendicular directions, first in one direction and then in the other. This movement is made possibly by openings in the plate that clear short columns supporting the surface segments. Yarn ends are moved about the surface and interwoven by shuttles which engage the reciprocating plate as needed to yield the desired movements. Power and control signals are transmitted to the shuttles through electrical contact with the braiding surface. The shuttle plate is a passively driven prime mover that supplies the power to move all shuttles and the shuttles are simple devices that employ only a solenoid to engage the shuttle plate on command. Each shuttle is assigned a unique identity and is controlled independently. When compared to each other, the Farley braider is felt to have the advantage of speed and the shuttle plate braider, the advantage of simplicity.

Huey, Cecil O., Jr.↗

Quantitative determination of engine water ingestion

A nonintrusive optical technique is described for determination of liquid mass flux in a droplet laden airstream. The techniques were developed for quantitative determination of engine water ingestion resulting from heavy rain or wheel spray. Independent measurements of the liquid water content (LWC) of the droplet laden airstream and of the droplet velocities were made at the stimulated nacelle inlet plane for the liquid mass flux determination. The LWC was measured by illuminating and photographing the droplets contained within a thin slice of the flow field by means of a sheet of light from a pulsed laser. A fluorescent dye introduced in the water enchanced the droplet image definition. The droplet velocities were determined from double exposed photographs of the moving droplet field. The technique was initially applied to a steady spray generated in a wind tunnel. It was found that although the spray was initially steady, the aerodynamic breakup process was inherently unsteady. This resulted in a wide variation of the instantaneous LWC of the droplet laden airstream. The standard deviation of ten separate LWC measurements was 31% of the average. However, the liquid mass flux calculated from the average LWC and droplet velocities came within 10% of the known water ingestion rate.

Parikh, P.↗

Quantitative determination of engine water ingestion

This paper describes a novel non-intrusive optical technique for determination of liquid mass flux in a droplet laden airstream. The technique was developed for quantitative determination of engine water ingestion resulting from heavy rain or wheel spray. Independent measurements of the liquid water content (LWC) of the droplet laden aircraft and of the droplet velocities were made at the simulated nacelle inlet plane for the liquid mass flux determination. The liquid water content was measured by illuminating and photographing the droplets contained within a thin slice of the flow field by means of a sheet of light from a pulsed YAG laser. A fluorescent dye introduced in the water greatly improved the droplet image definition. The droplet velocities were determined from double exposed photographs of the moving droplet field. The technique was initially applied to a steady spray generated in a wind tunnel. It was found that although the spray was initially steady, the aerodynamic breakup process was inherently unsteady. This resulted in a wide variation of the instantaneous liquid water content of the droplet laden airstream. The standard deviation of ten separate LWC measurements was 31 percent of the average. However, the liquid mass flux calculated from the average LWC and droplet velocities came within 10 percent of the known water ingestion rate.

Parikh, P.↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Dynamic Deformation Measurements of an Aeroelastic Semispan Model

The techniques used to acquire, reduce, and analyze dynamic deformation measurements of an aeroelastic semispan wind tunnel model are presented. Single-camera, single-view video photogrammetry (also referred to as videogrammetric model deformation, or VMD) was used to determine dynamic aeroelastic deformation of the semispan 'Models for Aeroelastic Validation Research Involving Computation' (MAVRIC) model in the Transonic Dynamics Tunnel at the NASA Langley Research Center. Dynamic deformation was determined from optical retroreflective tape targets at five semispan locations located on the wing from the root to the tip. Digitized video images from a charge coupled device (CCD) camera were recorded and processed to automatically determine target image plane locations that were then corrected for sensor, lens, and frame grabber spatial errors. Videogrammetric dynamic data were acquired at a 60-Hz rate for time records of up to 6 seconds during portions of this flutter/Limit Cycle Oscillation (LCO) test at Mach numbers from 0.3 to 0.96. Spectral analysis of the deformation data is used to identify dominant frequencies in the wing motion. The dynamic data will be used to separate aerodynamic and structural effects and to provide time history deflection data for Computational Aeroelasticity code evaluation and validation.

Graves, Sharon S.↗

Shear-Sensitive Liquid Crystal Coating Method: Surface-Inclination Effects on Shear Vector Measurements

The shear-sensitive liquid crystal coating (SSLCC) method is an image-based technique for both visualizing dynamic surface-flow phenomena, such as transition and separation, and for measuring the continuous shear-stress vector distribution acting on an aerodynamic surface. Under proper lighting and viewing conditions (discussed below), the coating changes color in response to an applied aerodynamic shear. This color-change response is continuous and reversible, with a response time of milliseconds, and is a function of both the shear magnitude and the shear vector orientation relative to the observer. The liquid crystal phase of matter is a weakly-ordered, viscous, non-Newtonian fluid state that exists between the nonuniform liquid phase and the ordered solid phase of certain organic compounds. Cholesteric liquid crystal compounds possess a helical molecular arrangement that selectively scatters white light, incident along the helical axis, as a three-dimensional spectrum. This property is linked to the helical pitch length, which is within the range of wavelengths in the visible spectrum. The pitch length, and hence the wavelength of the scattered light, is influenced by shear stress normal to the helical axis. This unique optical property produces a measurable color change in response to an applied shearing force. The full-surface shear stress vector measurement method, developed at NASA-Ames, is schematically illustrated. As with the visualization method, the coated test surface is illuminated from the normal direction with white light and the camera is positioned at an above-plane view angle of approximately 30 deg. Experiments have been initiated at NASA Ames to begin the process of quantifying surface-inclination (surface-curvature) effects on shear vector measurement accuracy. In preliminary experiments, surface-inclination angles theta(sub x), theta(sub y) of 0, +/-5, +/-10, and +/-15 deg were employed. In this arrangement, white-light illumination was positioned normal to the untilted test surface, and the camera above-plane view angle was set at 30 deg relative to the untilted test surface. As can be seen, vector-aligned lambda(sub d) values showed no dependence on theta(sub x) or theta(sub y) for absolute values of these tilt angles is less than or equal to 15 deg. Acquisition and analyses of full-surface color images are presently underway to definitively document the insensitivity limits of the shear vector measurement methodology to surface-slope variations.

Reda, Daniel C.↗

Qudit Designs and Where to Find Them

Unitary t-designs are some of the most versatile tools in quantum information theory. Their applications range from randomized benchmarking and shadow tomography, to more fundamental ones such as emulating quantum chaos and establishing exponential separations between classical and quantum query complexity. While unitary designs originating from a group structure, such as the Clifford group, have proven to be incredibly useful for qubit systems, unfortunately, this is no longer true for qudits. In fact, the classification of finite-group representations rules out the existence of unitary 2-designs for arbitrary qudit dimensions. This severely limits the applicability of standard quantum information primitives when it comes to qudit systems. We overcome these limitations with a three-fold contribution. First, we introduce a general technique to construct families of weighted state t-designs in arbitrary qudit dimensions. These weighted state-designs generalize classical shadow tomography protocol from qubits to qudits. Second, we introduce a Clifford character RB that allows us to benchmark the qudit Clifford group in any dimension, including non-prime-power dimensions. And third, we establish bounds on the quantum circuit complexity of generating approximate unitary-designs from native gates in existing quantum hardware such as high-spin and cavity-QED qudits. Our work further highlights the analogy between spin and optical coherent states by proving that spin-GKP codewords form a state 2-design while spin coherent states do not; in direct analogy with the optical case. This work is structured as a pedagogical and self-contained introduction to unitary designs and their applications to qudit systems.

Anand, Namit [NASA, Ames; Unlisted, US] (ORCID:000↗

Containerless, Low-Gravity Undercooling of Ti-Ce Alloys in the MSFC Drop Tube

Previous tests of the classical nucleation theory as applied to liquid-liquid gap miscibility systems found a discrepancy between experiment and theory in the ability to undercool one of the liquids before the L1-L2 separation occurs. To model the initial separation process in a two-phase liquid mixture, different theoretical approaches, such as free-energy gradient and density gradient theories, have been put forth. If there is a large enough interaction between the critical liquid and the crucible, both models predict a wetting temperature (T(sub w)) above which the minority liquid perfectly wets and layers the crucible interface, but only on one side of the immiscibility dome. Materials with compositions on the other side of the dome will have simple surface adsorption by the minority liquid before bulk separation occurs when the coexistence (i.e., binoidal) line in reached. If the interaction between the critical liquid and the crucible were to decrease, T(sub w) would increase, eventually approaching the critical consolute temperature (T(sub cc)). If this situation occurs, then there could be large regions of the miscibility gap where non-perfect wetting conditions prevail resulting in droplets of L1 liquid at the surface having a non-zero contact angle. The resulting bulk structure will then depend on what happens on the surface and the subsequent processing conditions. In the past several decades, many experiments in space have been performed on liquid metal binary immiscible systems for the purpose of determining the effects that different crucibles may have on the wetting and separation process of the liquids. Potard performed experiments that showed different crucible materials could cause the majority phase to preferentially wet the container and thus produce a dispersed microstructure of the minority phase. Several other studies have been performed on immiscibles in a semi-container environment using an emulsion technique. Only one previous study was performed using completely containerless processing of immiscible metals and the results of that investigation are similar to some of the emulsion studies. In all the studies, surface wetting was attributed as the cause for the similar microstructures or the asymmetry in the ability to undercool the liquid below the binoidal on one side of the immiscibility dome. By removing the container completely from the separation process, it was proposed that the loss of the crucible/liquid interaction would produce a large shift in T(sub w) and thus change the wetting characteristics at the surface. By investigating various compositions across the miscibility gap, a change in the type and amount of liquid wetting at the surface of a containerless droplet should change the surface nucleating behavior of the droplet - whether it be the liquid-liquid wetting or the liquid-to-solid transition. Undercooling of the liquid into the metastable region should produce significant differences in the separation process and the microstructure upon solidification. In this study, we attempt to measure these transitions by monitoring the temperature of the sample by optical pyrometry. Microstructural analysis will be made to correlate with the degree of undercooling and the separation mechanisms involved.

Robinson, M. B.↗

A Multiplicity Survey of Chromospherically Active and Inactive Stars

Surveys of the three samples of solar-type stars, segregated by chromospheric emission level, were made to determine their multiplicity fractions and to investigate the evolution of multiplicity with age. In total, 245 stars were searched for companions with DeltaV <= 3.0 and separations of 0.035" to 1.08" using optical speckle interferometry, By incorporating the visual micrometer survey for duplicity of the LamontHussey Observatory, the angular coverage was extended to 5.0" with no change in in the DeltaV limit. This magnitude difference allows mass ratios of 0.63 and larger to be detected throughout a search region of 2-127 AU for the stars observed. The 84 primaries observed in the chromospherically active sample are presumably part of a young population and are found to have a multiplicity fraction of 17.9% +/- 4.6%. The sample of 118 inactive, presumably older, primaries were selected and observed using identical methods and are found to have a multiplicity fraction of only 8.5% +/- 2.7%. Given the known link between chromospheric activity and age, these results tentatively imply a decreasing stellar multiplicity fraction from 1 to 4 Gyr, the approximate ages of the two samples. Finally, only two of the 14 very active primaries observed were found to have a companion meeting the survey detection parameters. In this case, many of the systems are either very young, or close, RS CVn type multiples that are unresolvable using techniques employed here.

Mason, Brian D.↗

Dose-Response Evaluation of Braslet-M Occlusion Cuffs

Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current non-imaging calibration techniques.

Ebert, Douglas↗

Orion Artemis I As Flown MMOD Analysis

Introduction The Lockheed Martin Orion spacecraft conducted the Artemis I flight around the Moon from November 16 through December 11, 2022. After the flight, an engineer from the NASA Johnson Space Center (JSC) Hypervelocity Impact Technology (HVIT) Group performed a Micrometeoroid and Orbital Debris MMOD analysis using the Bumper 3 risk assessment tool to predict the number of small impacts that would likely have occurred during the mission. Separately, a team from the same group inspected the Orion capsule for hypervelocity impact damage features. The results of the inspection were compared to those of the analysis to aid in improving the analysis, including the environment models. Scope of Work The spacecraft geometry model was created by Lockheed Martin during construction of the Artemis I Orion vehicle based on Computer Aided Design (CAD) models of the vehicle. New hypervelocity impact testing was performed to verify Ballistic Limit Equations (BLEs) used in the analysis to link impactor size and damage to the Thermal Protection System (TPS). The exact trajectory flown was recorded during the flight, including vehicle attitude. This data was used in conjunction with the ORDEM 3.2 and MEM 3 environment modeling tools to create models of particle flux impacting the spacecraft throughout the mission. Meteoroid shower forecast information was also included to account for additional particle flux associated with meteoroid showers. Inspection of the Orion capsule included the Backshell thermal tiles and the tape covering it, windows, fabric thermal materials, and small areas of other materials. Potential MMOD damage found was characterized using various techniques, including optical microscopy, computed tomography scanning, and X-ray spectroscopy. Findings The number of craters found in the Backshell tile, and their size distribution, matches well with the Bumper analysis prediction. Tape, window, and other material impacts recorded similarly align to Bumper analysis predictions. Conclusions and Recommendations This comparison of analysis with inspection of the hardware provides valuable insight into the MMOD environment and how accurately analysis tools assess the impact risk to spacecraft. As this was the first large, non-ablative returned surface from a lunar mission, this analysis extends the MMOD community’s insight beyond low Earth orbit into cis-lunar space.

MMOD↗