Search NASA⌕ Search

SEARCH · Search NASA

Results for “packaging materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-00600

The Savannah River Site (SRS) stores packages containing plutonium (Pu) materials in the K-Area Complex (KAC). The Pu materials are packaged per the DOE 3013 Standard and stored within Model 9975 shipping packages in KAC. The KAC facility DSA (Document Safety Analysis) [1] credits the Model 9975 package to perform several safety functions, including criticality, impact resistance, containment, and fire resistance to ensure the plutonium materials remain in a safe configuration during normal and accident conditions. The Model 9975 package is expected to perform its safety function for at least 12 years from initial packaging. The DSA recognizes the degradation potential for the materials of package construction over time in the KAC storage environment and requires an assessment of materials performance to validate the assumptions of the analysis and ultimately predict service life. As part of the comprehensive Model 9975 package surveillance program [2-3], destructive examination of package 9975-00600 was performed following field surveillance in accordance with Reference [4]. Field surveillance of the Model 9975 package in KAC included nondestructive examination of the drum, fiberboard, lead shield and containment vessels [5]. Results of the field surveillance are provided in Attachment 1. Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-00600. For those attributes that were also measured during the field surveillance, no significant changes were observed. Three conditions were identified that do not meet inspection criteria. These conditions are subject to additional investigation and disposition by the Surveillance Program Authority. The conditions include: (1) The lead shield was covered with a white corrosion layer; (2) The lead shield height dimension exceeded drawing requirements; and (3) Fiberboard thermal conductivity in the axial direction exceeded the specified range. The Surveillance Program Authority was notified of these conditions. All other observations and test results met identified criteria, or were collected for information and trending purposes.

42 ENGINEERING↗

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-02168

The Savannah River Site (SRS) stores packages containing plutonium (Pu) materials in the K-Area Complex (KAC). The Pu materials are packaged per the DOE 3013 Standard and stored within Model 9975 shipping packages in KAC. The KAC facility DSA (Document Safety Analysis) credits the Model 9975 package to perform several safety functions, including criticality prevention, impact resistance, containment, and fire resistance to ensure the plutonium materials remain in a safe configuration during normal and accident conditions. The Model 9975 package is expected to perform its safety function for at least 12 years from initial packaging. The DSA recognizes the degradation potential for the materials of package construction over time in the KAC storage environment and requires an assessment of materials performance to validate the assumptions of the analysis and ultimately predict service life. As part of the comprehensive Model 9975 package surveillance program, destructive examination of package 9975-02028 was performed following field surveillance in accordance with Reference. Field surveillance of the Model 9975 package in KAC included nondestructive examination of the drum, fiberboard, lead shield and containment vessels. Results of the field surveillance are provided in Attachment 1. Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-02168. For those attributes that were also measured during the field surveillance, no significant changes were observed. Two conditions were identified that do not meet inspection criteria. These conditions are subject to additional investigation and disposition by the Surveillance Program Authority. The conditions include: (1) The lead shield was covered with a white corrosion layer, and (2) Fiberboard thermal conductivity in the axial direction exceeded the specified range. The Surveillance Program Authority was notified of these conditions and will document the findings by surveillance report. All other observations and test results met identified criteria, or were collected for information and trending purposes.

42 ENGINEERING↗

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-02028

Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-02028. For those attributes that were also measured during the field surveillance, no significant changes were observed. Four conditions were identified that do not meet inspection criteria. These conditions are subject to additional investigation and disposition by the Surveillance Program Authority. The conditions include: (1) The lead shield was covered with a white corrosion layer; (2) The lead shield height exceeds drawing requirements; (3) Mold was observed on the lower fiberboard subassembly; and (4) Fiberboard thermal conductivity in the axial direction exceeded the specified range. The Surveillance Program Authority was notified of these conditions and will document the disposition by surveillance report. All other observations and test results met identified criteria, or were collected for information and trending purposes. The Savannah River Site (SRS) stores packages containing plutonium (Pu) materials in the K-Area Complex (KAC). The Pu materials are packaged per the DOE 3013 Standard and stored within Model 9975 shipping packages in KAC. The KAC facility DSA (Document Safety Analysis) credits the Model 9975 package to perform several safety functions, including criticality prevention, impact resistance, containment, and fire resistance to ensure the plutonium materials remain in a safe configuration during normal and accident conditions. The Model 9975 package is expected to perform its safety function for at least 12 years from initial packaging. The DSA recognizes the degradation potential for the materials of package construction over time in the KAC storage environment and requires an assessment of materials performance to validate the assumptions of the analysis and ultimately predict service life. As part of the comprehensive Model 9975 package surveillance program, destructive examination of package 9975-02028 was performed following field surveillance in accordance with Reference. Field surveillance of the Model 9975 package in KAC included nondestructive examination of the drum, fiberboard, lead shield and containment vessels. Results of the field surveillance are provided in Attachment 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Materials Assessment of Insulating Foam in the 9977 Shipping Package for Long-Term Storage - Annual Report

The 9977 shipping package is being evaluated for long-term storage applications in the K-Area Complex (KAC) with specific focus on the packaging foam material. A rigid closed cell polyurethane foam, LAST-A-FOAM® FR-3716, produced by General Plastics Manufacturing Company is sprayed and expands to fill the void between the inner container and the outer shell of the package. The foam is sealed in this annular space and is not accessible. During shipping and storage, the foam experiences higher than ambient temperatures from the heat generated by nuclear material within the package creating the potential for degradation of the foam. A series of experiments is underway to determine the extent of foam degradation. Foam samples of three densities have been aging at elevated temperatures 160 °F, 160 °F + 50% relative humidity (RH), 185 °F, 215 °F, and 250 °F since 2014. Samples were periodically removed and tested. After approximately 80 weeks, samples conditioned at 160 °F, 160 °F + 50% RH, and 185 °F have retained initial property values while samples conditioned at 215 °F have reduced intumescence. Samples conditioned at 250 °F have shown the most degradation, loss of volume, mass, absorbed energy under compression, intumescence, and increased flammability. Based on the initial data, temperatures up to 185 °F have not yet shown an adverse effect on the foam properties and it is recommended that exposure of FR-3716 foam to temperatures in excess of 250 °F be avoided or minimized. Testing will continue beyond the 96 week mark. This will provide additional data to help define the long-term behavior for the lower temperature conditions. Additional testing will be pursued in an attempt to identify transition points (threshold times and temperatures) at the higher temperatures of interest, as well as possible benefits of aging within the relatively oxygen-free environment the foam experiences inside the 9977 shipping package.

36 MATERIALS SCIENCE↗

9975 SHIPPING PACKAGE PERFORMANCE OF ALTERNATE MATERIALS FOR LONG-TERM STORAGE APPLICATION

The Model 9975 shipping package specifies the materials of construction for its various components. With the loss of availability of material for two components (cane fiberboard overpack and Viton{reg_sign} GLT O-rings), alternate materials of construction were identified and approved for use for transport (softwood fiberboard and Viton{reg_sign} GLT-S O-rings). As these shipping packages are part of a long-term storage configuration at the Savannah River Site, additional testing is in progress to verify satisfactory long-term performance of the alternate materials under storage conditions. The test results to date can be compared to comparable results on the original materials of construction to draw preliminary conclusions on the performance of the replacement materials.

42 ENGINEERING↗

PRECEDENTS FOR AUTHORIZATION OF CONTENTS USING DOSE RATE MEASUREMENTS

For the transportation of Radioactive Material (RAM) packages, the requirements for the maximum allowed dose rate at the package surface and in its vicinity are given in Title 10 of the Code of Federal Regulations, Section 71.47. The regulations are based on the acceptable dose rates to which the public, workers, and the environment may be exposed. As such, the regulations specify dose rates, rather than quantity of radioactive isotopes and require monitoring to confirm the requirements are met. 10CFR71.47 requires that each package of radioactive materials offered for transportation must be designed and prepared for shipment so that under conditions normally incident to transportation the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external Surface of the package, and the transport index does not exceed 10. Before shipment, the dose rate of the package is determined by measurement, ensuring that it conforms to the regulatory limits, regardless of any analyses. This is the requirement for all certified packagings. This paper discusses the requirements for establishing the dose rates when shipping RAM packages and the precedents for meeting these requirements by measurement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

COMBIgor: Data-Analysis Package for Combinatorial Materials Science

Combinatorial experiments involve synthesis of sample libraries with lateral composition gradients requiring spatially-resolved characterization of structure and properties. Here, due to maturation of combinatorial methods and their successful application in many fields, the modern combinatorial laboratory produces diverse and complex data sets requiring advanced analysis and visualization techniques. In order to utilize these large data sets to uncover new knowledge, the combinatorial scientist must engage in data science. For data science tasks, most laboratories adopt common-purpose data management and visualization software. However, processing and cross-correlating data from various measurement tools is no small task for such generic programs. Here we describe COMBIgor, a purpose-built open-source software package written in the commercial Igor Pro environment, designed to offer a systematic approach to loading, storing, processing, and visualizing combinatorial data sets. It includes (1) methods for loading and storing data sets from combinatorial libraries, (2) routines for streamlined data processing, and (3) data analysis and visualization features to construct figures. Most importantly, COMBIgor is designed to be easily customized by a laboratory, group, or individual in order to integrate additional instruments and data-processing algorithms. Utilizing the capabilities of COMBIgor can significantly reduce the burden of data management on the combinatorial scientist.

97 MATHEMATICS AND COMPUTING↗

Risk-Informed Approach for Regulatory Approval of Microreactor Transport

Pacific Northwest National Laboratory (PNNL) is addressing the challenges associated with safe transport of microreactors including the development and evaluation of regulatory options. PNNL developed a risk-informed regulatory framework for the licensing of the transportation of microreactors in which irradiated nuclear fuel is part microreactor transportation package. The framework lays out a viable regulatory pathway, including decision points for regulatory options and the supporting technical evaluations for those options in phases from near to long term. A microreactor and its contents will likely not be able to meet all the federal regulatory requirements as a Type B or fissile material transportation package under 10 CFR Part 71 (“Packaging and Transportation of Radioactive Material”). However, the regulatory framework developed by PNNL lays out a viable risk-informed licensing options that are safe and feasible. Risk assessment such as probabilistic risk assessment (PRA) can be used to show comparable safety to that provided by a Type B or fissile material package for surface transport. The framework includes guidance on applicable regulations and discusses historical precedence in using risk information for transportation licensing. The framework includes guidance for performing a microreactor transportation PRA, use and development of risk evaluation criteria, and factors such of defense-in-depth and safety margin concepts. Key advantages of using the approach are (1) increasing the likelihood of successfully obtaining regulatory transportation package approval, (2) informing the design on the relative risk significance of microreactor containment and shielding, and (3) informing the need for transportation compensatory measures. This paper focuses on two primary elements of the framework which are development of a transportation PRA for microreactor packages and development of the risk acceptance guidelines to assess the results of the PRA for regulatory decision-making.

microreactor, micro nuclear power plant, MNPP, ris↗

Destructive Examination Protocol for 3013-Container-Package Storing Plutonium-Bearing Materials

The 3013-container-package consists of a convenience, inner and outer container and is used for long-term storage of plutonium-bearing materials. A destructive examination (DE) protocol has been developed to examine the container package visually and with microscopic aid to find any corrosion conditions that could result in the loss of the integrity of the container package over its lifetime. The DE protocol contains three main steps: initial container examination, helium (He) leak testing, and detailed imaging and analysis of the inner container closure weld region (ICCWR). The ICCWR has been determined to be bounding, defined as exhibiting worst case conditions for stress corrosion cracking (SCC) of the inner container. To assess SCC in the ICCWR, the inner container lid is cut into quarters and the weld and He-leak testing gasket are removed. Then a citric acid wash is performed to remove adherent chlorides from the ICCWR. The wash is then sent for analysis to determine the concentration of chlorides in the ICCWR. While the analysis for chloride concentration is being performed, the quarter sections are further sectioned into 1/8th subsections by cutting each section in half. These subsections are washed using nitric acid to remove corrosion products. Then each subsection is imaged using a Wide Angle 3-D Measurement System (WAMS). After analysis of microscope images for potential SCC, additional imaging can be performed, including subsurface imaging. After review, a determination is made of whether the container integrity may potentially affect the safe storage of the material.

container↗

HMPT: Basic Radioactive Material Transportation

Hazardous Materials and Packaging and Transportation (HMPT): Basic Radioactive Material Transportation Live (#30462, suggested one time) and Test (#30463, required initially and every 36 months) address the Department of Transportation’s (DOT’s) function-specific [required for hazardous material (HAZMAT) handlers, packagers, and shippers] training requirements of the HMPT Los Alamos National Laboratory (LANL) Labwide training. This course meets the requirements of 49 CFR 172, Subpart H, Section 172.704(a)(ii), Function-Specific Training.

42 ENGINEERING↗

Life and stability testing of packaged low-cost energy storage materials

Thermal cycling and performance tests, performed to verify the package integrity, life, and stability of the chub packaged materials system for storage coolness with application to residential air conditioning, are described. The moisture vapor retention characteristics of the laminate film for long term chub performance was determined. The stability, mechanical integrity, and thermal performance of chubs following mechanical shock, vibration, and temperature extremes is reported.

Frysinger, G. R.↗