Search NASA⌕ Search

SEARCH · Search NASA

Results for “parametric analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

A Pilot-Scale Evaluation of Natural Gas-Based Foam at Elevated Pressure and Temperature Conditions

Abstract Nitrogen (N2) and Carbon Dioxide (CO2) foams have been used as hydraulic fracturing fluids for several decades to reduce water usage and minimize damage in water-sensitive reservoirs. These foam treatments require gases to be liquefied and transported to site. An alternative approach would be to use natural gas (NG) that is readily available from nearby wells, pipelines, and processing facilities as the internal, gaseous phase to create a NG-based foam. Hydraulic fracturing with NG foam is a relatively inexpensive option, makes use of an abundant and often wasted resource, and may even provide production benefits in certain reservoirs. As part of an ongoing development project sponsored by the Department of Energy (DOE), the surface process to create NG foam is being developed and the properties of NG foam are being explored. This paper presents recent results from a rigorous pilot-scale demonstration of NG foam over a range of operating scenarios relevant to surface and bottomhole conditions with a variety of base-fluid mixtures. The Pilot-scale Foam Test Facility (PFTF) used in these investigations is first described. The PFTF is capable of generating foamed fluids at pressures up to 7,500 psig and at temperatures in excess of 300°F. Then, results from several investigations aimed at proving NG foam at conditions relevant to the field are presented. NG foam was characterized using rheology measurements and flow visualization techniques. Experiments were performed to investigate the texture and stability of NG foam generated by two different mixing methods: one using a custom designed tee to match mixing velocities in the field where the gas phase is jetted into the aqueous stream, and another to ensure comprehensive mixing for laboratory analysis. Parametric studies were conducted to explore the effects of flow rate, foam quality, and temperature on the stability of NG foam. Moreover, different fluid preparations were used to investigate the effect of base fluid and additive concentrations on the stability of NG foams. Additional laboratory studies that investigated foam stability with produced water and multicomponent NG mixtures are also reported. The NG foams explored in these investigations exhibited typical, shear-thinning behavior observed in rheological studies of N2- and CO2-based foams. The measured viscosity and observed stability indicate that NG foams are well suited for fracturing applications. Like other foams, NG foam exhibits sensitivity to operating temperature characterized by a decrease in apparent viscosity as temperature increases. Rapid foam breakdown was observed at significantly elevated temperatures exceeding 290°F. In addition to fluid characterization, these investigations also yielded several key lessons that should be applied to future field demonstrations of NG foam.

Beck, Griffin↗

Development of Seismic Isolation Systems Using Periodic Materials

Advanced fast nuclear power plants and small modular fast reactors are composed of thin-walled structures such as pipes; as a result, they do not have sufficient inherent strength to resist seismic loads. Seismic isolation, therefore, is an effective solution for mitigating earthquake hazards for these types of structures. Base isolation, on which numerous studies have been conducted, is a well-defined structure protection system against earthquakes. In conventional isolators, such as high-damping rubber bearings, lead-rubber bearings, and friction pendulum bearings, large relative displacements occur between upper structures and foundations. Only isolation in a horizontal direction is provided; these features are not desirable for the piping systems. The concept of periodic materials, based on the theory of solid-state physics, can be applied to earthquake engineering. The periodic material is a material that possesses distinct characteristics that prevent waves with certain frequencies from being transmitted through it; therefore, this material can be used in structural foundations to block unwanted seismic waves with certain frequencies. The frequency band of periodic material that can filter out waves is called the band gap, and the structural foundation made of periodic material is referred to as the periodic foundation. The design of a nuclear power plant, therefore, can be unified around the desirable feature of a periodic foundation, while the continuous maintenance of the structure is not needed. In this research project, three different types of periodic foundations were studied: one-dimensional, two-dimensional, and three-dimensional. The basic theories of periodic foundations are introduced first to find the band gaps; then the finite element methods are used, to perform parametric analysis, and obtain attenuation zones; finally, experimental programs are conducted, and the test data are analyzed to verify the theory. This procedure shows that the periodic foundation is a promising and effective way to mitigate structural damage caused by earthquake excitation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Method for Calculating Delayed Gamma-Ray Response in the ACRR Central Cavity and FREC-II Cavity Using MCNP

This document presents the process for a new method developed for the characterization of the delayed gamma-ray radiation fields in pulse reactors like the Annular Core Research Reactor (ACRR) and the Fueled Ring External Cavity (FREC-II). The environments used to test this method in the ACRR were FF, LB44, PLG and CdPoly, and the environments used in the FREC-II were FF with rods-down, FF with rods-up, CdPoly with rods-down and CdPoly with rods-up. All environment configurations used the same fission product gamma-ray source energy spectrum. This method required the fission sites located in the MCNP KCODE source tapes. A FORTRAN script was written to translate and extract the coordinates for the fission sites. The 10K fission sites were then input it into an MCNP SOURCE mode script. Using a MATLAB script, a parametric analysis was done, and it helped determine that 10K fission sites are an appropriate number of coordinates to converge to the correct answer. The method gave excellent results and was tested in the ACRR, FREC-II and White Sands Missile Range (WSMR). This method can be applied to other pulse research reactors as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Phenomenological Model for the Transport and Plugging of Aerosol through Stress Corrosion Cracks

Recent experimental evidence from Sandia (2018) demonstrated partial microchannel plugging due to particulate deposition. A direct consequence is that the accuracy of consequence assessments can be improved by accounting for the leak path deposition of aerosol in the source term. The filtration effect of microchannels, such as cracks, is relevant to the source term assessments. An important side effect of aerosol deposition in leak paths could be the plugging of the leak path. This report summarizes current progress (as of end of FY19) on the development of a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose is to introduce a generic, reliable numerical model for prediction of aerosol transport, deposition, and plugging in leak paths that are similar to stress corrosion cracks while accounting for potential plugging formation. This effort includes (i) development of a numerical model to analyze the various deposition processes in leak paths and provide quantitative estimates of penetration factors, as well as an understanding of the variables that affect them, (ii) confirmation of model validity with theoretical and experimental data, and (iii) parametric analysis for different scenarios including various particle sizes, pressures, and crack dimensions. Such a model could be used to improve the accuracy of consequence assessments and reduce the uncertainty of radiological consequence predictive analyses by taking the filtering effect of leak path aerosol deposition and plugging into account in the source term. This report includes: (i) an overview of main stress corrosion cracking characteristics, (ii) an overview of the developed numerical model to analyze the various deposition processes in leak paths, to provide quantitative estimates of penetration factors, and to gain an understanding of the variables that affect them, (iii) a summary of validation results and verification of the model’s validity with recent experimental results from Sandia and others, and (iv) a model application example.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Powdermet CRADA for VELOCITI Voucher (CRADA Final Report)

NLR shall develop a model of an electric thermal energy storage (ETES) system in the System Advisor Model (SAM) framework that uses a salt and particle slurry developed by PowderMet as the thermal energy storage medium. The ETES shall consist of a recuperated sCO 2 Brayton cycle using 2-tank indirect thermal energy storage and an electric heater for heat input. The salt slurry uses chloride salt and operates at a maximum temperature of 500-720°C. The ETES uses dry air cooling. The salt slurry will be modeled as a sensible heat storage medium and as a latent heat storage medium. NLR will use the model to do parametric analysis of the factors affecting the performance (ex., round trip efficiency) of the ETES system. NLR will work with PowderMet to estimate the costs of system components and total system costs, with the levelized cost of electricity (LCOE) as the primary cost metric.

14 SOLAR ENERGY↗

The ITPA disruption database

A multi-device database of disruption characteristics has been developed under the auspices of the International Tokamak Physics Activity magneto-hydrodynamics topical group. The purpose of this ITPA disruption database (IDDB) is to find the commonalities between the disruption and disruption mitigation characteristics in a wide variety of tokamaks in order to elucidate the physics underlying tokamak disruptions and to extrapolate toward much larger devices, such as ITER and future burning plasma devices. In contrast to previous smaller disruption data collation efforts, the IDDB aims to provide significant context for each shot provided, allowing exploration of a wide array of relationships between pre-disruption and disruption parameters. The IDDB presently includes contributions from nine tokamaks, including both conventional aspect ratio and spherical tokamaks. An initial parametric analysis of the available data is presented. This analysis includes current quench rates, halo current fraction and peaking, and the effectiveness of massive impurity injection. The IDDB is publicly available, with instruction for access provided herein.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of hydrogen slush-hydrogen gel utilization

Study of hydrogen slush-hydrogen gel utilization is presented in two volume publication. The first volume contains the physical and thermal property data for hydrogen used in the study. In the second volume, details of the technical effort are presented including parametric analysis of effects on vehicle systems.

Keller, C. W.↗