Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Texas Instruments' virtual phase charge-coupled device (CCD) imager operated in the frontside electron-bombarded mode

The present investigation is concerned with the suitability of the virtual phase CCD imager for frontside detection of electrons up to 25 keV. The investigation has the objective to determine if the imager can be used in the frontside mode with a photocathode to detect very low light levels in astronomical applications, the ultimate goal being individual photon detection. It is found that the standard virtual phase imager will function properly over an extended period at low levels of 20 kV electron irradiation consistent with photon counting applications. The imager can detect individual primary electrons with nearly 100 percent efficiency. However, further studies are needed to determine the mechanisms for the flat band shifts so that the imager design may be modified to eliminate or at least reduce them.

Everett, P.↗

The High Spectral Resolution Lidar

The High Spectral Resolution Lidar (HSRL) system was developed for the remote measurement of atmospheric optical properties. Measurements are obtained by the separation of the backscattered signal into aerosol and molecular channels using a high spectral resolution Fabry-Perot optical interferometer to separate the aerosol contributions to backscatter near the laser wavelength from the Doppler-shifted molecular component of the backscatter. The transmitter consists of an optically pumped pulsed dye laser of the oscillator-amplifier design which emits at 467.88 nm, with a bandwidth of less than 0.3 pm. The transmitter and receiver share a common Schmidt-Cassegrain telescope, although they do not share the same field stop, but rather two conjugate stops. The HSRL system uses a computer-controlled dual-channel photon-counting data acquisition system providing for stable measurements at very low power levels and an excellent dynamic range. The system has been used to obtain airborne measurements of height profiles of aerosol and molecular backscatter cross sections.

Eloranta, E. W.↗

Image plane detector for the dynamics explorer Fabry-Perot interferometer

A compact twelve-channel photon-counting device based on existing Generation II imaging technology has been developed for use as the image-plane detector of the Dynamics Explorer Fabry-Perot interferometer. The device has an S-20 photocathode, three-microchannel plate electron multiplication stages, and an equal-area concentric-ring segmented anode whose geometry mimics that of the interference ring pattern produced by a plane etalon. The twelve channels sample equal and contiguous intervals in the spectrum. The purpose of the delopment has been to utilize the signal multiplex advantage of a multichannel detector in the measurement of Doppler shifts and line-broadening effects for naturally occurring atmospheric emission features of low intensity. The design, testing, calibration, and flight performance of the novel detector system are presented. In addition, measured emission line profiles at high resolution from the satellite instrument are presented to illustrate the operation of the device.

Killeen, T. L.↗

Detailed Performance Calculations: Portland State Group, Appendix F

For the Portland State University FAGE instrument, laser induced OH is calculated from (OH) laser = Cl(03)amb(H2O)amb. The dominant noise sources are the photon-counting fluctuations associated with the OH signal and the fluorescence background as well as concentration fluctuations in OH and in the species causing the background. Baric filtering and temporal filtering suppress the background by factors of 10 each.

Source record↗

Photon Detection with Cooled Avalanche Photodiodes: Theory and Preliminary Experimental Results

Avalanche photodiodes (APDs) can be operated in a geiger-tube mode so that they can respond to single electron events and thus be used as photon counting detectors. Operational characteristics and theory of APDs while used in this mode are analyzed and assessed. Preliminary experimental investigation of several commercially available APDs has commenced, and initial results for dark count statistics are presented.

Robinson, D. L.↗

Search for optical bursts from the gamma ray burst source GBS 0526-66

Attempts were made to detect optical bursts from the gamma-ray burst source GBS 0526-66 during Dec. 31, 1984 to Jan. 2, 1985 and Feb. 23 to Feb. 24, 1985, using the one meter reflector of the Kavalur Observatory. Jan. 1, 1985 coincided with the zero phase of the predicted 164 day period of burst activity from the source (Rothschild and Lingenfelter, 1984). A new optical burst photon counting system with adjustable trigger threshold was used in parallel with a high speed photometer for the observations. The best time resolution was 1 ms and maximum count rate capability was 255,000 counts s(-1). Details of the instrumentation and observational results are presented.

Seetha, S.↗

MOSAIC

The Mosaicked Optical Self-scanned Array Imaging Camera (MOSAIC), is a 50 sq cm active area detector system encompassing 5.76 million picture elements. This camera is being developed for use in astronomical instrumentation requiring the use of large area imaging detectors with high resolution photon counting capability in the space ultraviolet. This paper gives a descriptive outline of the MOSAIC camera system including: the 100 mm diameter microchannel plate intensifier, the 3 x 3 array of 800 x 800 pixel charge coupled devices, the signal processing and buffer storage subsystem, the electronic support and control subsystem, and the data processing subsystem. Performance characteristics of the camera and its subsystems are presented, based on system analysis.

Williams, J. T.↗

Nondispersive X-ray spectroscopy and imaging of plasmas using a charge-coupled device

A virtual-phase charge-coupled device (CCD) was used to obtain pinhole images and X-ray spectra of laser-produced, solid target plasmas. With the CCD used in the single-photon counting mode, the spectrum in the energy range 2-10 keV was obtained without a dispersive element. Typical spectra reveal two distinct temperatures: a cold component of approximately 200 eV and a hot component of approximately 5 keV. Also, multiline spectra comprising characteristic line emission (K alpha, K beta) from a multilayer target bombarded by beta-rays were recorded using a three-phase CCD. The results demonstrate the potential of CCDs as imaging spectrometers with application in space, laboratory, and fusion-plasma research.

Marsh, K.↗

Spectrophotometric and model-atmosphere analyses of the hot DO and DAO white dwarfs from the Palomar-Green survey

Recent optical and spectrophotometric observations of all currently known DAO and DO hot white dwarf candidates from the Palomar-Green Survey are presented. The optical observations were carried out using the Kitt Peak National Observatory Intensified Image Dissector Scanner (IIDS) system, the Multiple Mirror Telescope (MMT), and two photon-counting Reticon systems. Ultraviolet spectrophotometry was obtained using the International Ultraviolet Explorer (IUE) short-wavelength and long-wavelength cameras. The following spectroscopic subgroups were identified in the observations: the cool DO stars with spectra showing H I features together with He II + H blends; the hot DO stars, with spectra exhibiting weak He II (+H) lines; and hydrogen-rich DAO stars with broad H lines and sharp H II lines at 4686 A. A fourth subgroup of stars resembling PG 1159 with He at He II lines at 4686, and a C, N ion blend in the optical spectrum were also found. The spectroscopic data were analyzed in terms of a grid of hot, high-gravity LTE model atmospheres composed of a mixture of hydrogen and helium, and atmospheric parameters are deduced for each class of objects. On the basis of the model atmosphere analysis, the local space density of the DO stars is estimated to be 1.9-3.0 x 10 to the -7th per cubic pc, depending on the scale height.

Wesemael, F.↗

Astronomical research at the Hopkins Phoenix Observatory

After trying astrophotography and radio astronomy it was decided that the best way to do meaningful astronomical research at a small private observatory was by doing photoelectric photometry. Having the observatory located in the back yard of a private residence affors the luxury of observing any time the sky conditions permit. Also modest equipment is all that is needed to do accurate UBV photometry of stars 8th magnitude and brighter. Since beginning in 1980 the Hopkins Phoenix Observatory has published papers on several RS CVn star systems, 31 Cygni, 22 Vul, 18 Tau Per, and has followed the 1982-1984 eclipse of Epsilon Aurigae from its start to the present with over 1000 UBV measurements. In addition the Hopkins Phoenix Observatory has developed several pieces of photometry equipment including the HPO PEPH-101 photometer head and photon counting electronics.

Hopkins, J. L.↗

Interstellar Medium Absorption Profile Spectrograph (IMAPS)

The design and fabrication of an objective-grating echelle spectrograph to fly on sounding rockets and record spectra of stars from approximately 920 to 1120A with a resolving power lambda/delta lambda = 200,000 is discussed. The scientific purpose of the program is to observe, with ten times better velocity resolution than before, the plentiful absorption lines in this spectral region produced by atoms, ions and molecules in the interstellar medium. In addition, an important technical goal is to develop and flight-quality a new ultraviolet, photon-counting image sensor which has a windowless, opaque photocathode and a CCD bombarded directly by the accelerated photoelectrons. Except for some initial difficulties with the performance of CCDs, the development of the payload instrument is relatively straightforward and our overall design goals are satisfied. The first flight occurred in late 1984, but no data were obtained because of an inrush of air degraded the instrument's vacuum and caused the detector's high voltage to arc. A second flight in early 1985 was a complete success and obtained a spectrum of pi Sco. Data from this mission are currently being reduced; quick-look versions of the spectra indicate that excellent results will be obtained. Currently, the payload is being reconfigured to fly on a Spartan mission in 1988.

Jenkins, E. B.↗

The prototype MOSAIC detector

The prototype of the MOSAIC (Mosaicked Optical Self-scanned Array Imaging Camera) system, a photon-counting detector designed for use in the far ultraviolet, is described. MOSAIC has a two-dimensional format of 2400 x 2400 pixels, and is easily expandable. Readout is accomplished electronically via charge-coupled devices, making possible remote observations. Preliminary results of computer simulations of the system are presented.

Weistrop, D.↗

Dual-Energy X-Radiography With Gadolinium Filter

Image resolution increased, and cost reduced. Proposed dual-energy x-ray imaging system, continuous bremsstrahlung spectrum from x-ray tube filtered by foil of nonradioactive gadolinium or another rare-earth metal to form two-peaked energy spectrum. After passing through patient or object under examination, filtered radiation detected by array of energy-discriminating, photon-counting detectors. Detector outputs processed to form x-ray image for each peak and possibly enhanced image based on data taken at both peaks.

Rutt, Brian↗

Lower atmospheric temperature profile measurements using a Raman lidar

A Raman lidar system was used to measure the temperature profile of the upper troposphere and lower stratosphere. The system consists of a tripled Nd-YAG laser and a 1.5 meter diameter telescope. Two photomultipliers are used at the output of the telescope to allow for measurements at both the laser wavelength and at the Raman shifted wavelength due to atmospheric nitrogen. The signal from the photomultipliers is recorded as photon counts in 1 microsec bins. The results of a number of laser shots are summed together to provide atmospheric returns which have acceptable signal to noise characteristics. Measurements of the Raman nitrogen return were acquired up to an altitude in excess of 20 km. Temperature profiles were retrieved from the attenuation corrected Raman nitrogen return assuming the atmosphere to be in hydrostatic equilibrium and using the ideal gas law. Retrieved temperature profiles are shown compared with independent temperature measurements.

Melfi, S. H.↗

Observations of stratospheric aerosols associated with the El Chichon eruption

Lidar observations of aerosols were carried out at Aberystwyth between Nov. 1982 and Dec. 1985 using a frequency doubled and frequency tripled Nd/Yag laser and a receiver incorporating a 1 m diameter in a Newtonian telescope configuration. In analyses of the experimental data attention is paid to the magnitude of the coefficient relating extinction and backscatter, the choice being related to the possible presence of aerosols in the upper troposphere and the atmospheric densities employed in the normalisation procedure. The aerosol loading showed marked day to day changes in early months and an overall decay was apparent only after April 1983, this decay being consistent with an e sup -1 time of about 7 months. The general decay was accompanied by a lowering of the layer but layers of aerosols were shown intermittently at heights above the main layer in winter months. The height variations of photon counts corrected for range, or of aerosol backscatter ratio, showed clear signatures of the tropopause. A strong correlation was found between the heights of the tropopause identified from the lidar measurements and from radiosonde-borne temperature measurements. A notable feature of the observations is the appearance of very sharp height gradients of backscatter ratio which seem to be produced by differential advection.

Thomas, L.↗

Research relative to high resolution camera on the advanced X-ray astrophysics facility

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Source record↗

A cooled avalanche photodiode with high photon detection probability

An avalanche photodiode has been operated as a photon-counting detector with 2 to 3 times the sensitivity of currently-available photomultiplier tubes. APD (avalanche photodiodes) detection probabilities that exceed 27% and approach 50% have been measured at an optimum operating temperature which minimizes noise. The sources of noise and their dependence on operating temperature and bias voltage are discussed.

Robinson, D. L.↗

The Advanced X-ray Astrophysics Facility high resolution camera

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the X-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft X-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15th ergs/sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Murray, Stephen S.↗