Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

TU-EF-207-04: Advances in Detector Technology for Breast Tomosynthesis

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-05: Dedicated Cone-beam Breast CT

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

In-flight verification of the calibration and performance of the ASTRO-H (Hitomi) Soft X-ray Spectrometer

The Soft X-ray Spectrometer onboard the Astro-H (Hitomi) orbiting x-ray observatory featured an array of 36 silicon thermistor x-ray calorimeters optimized to perform high spectral resolution x-ray imaging spectroscopy of astrophysical sources in the 0.3- to 12-keV band. Extensive preflight calibration measurements are the basis for our modeling of the pulse height–energy relation and energy resolution for each pixel and event grade, telescope collecting area, detector efficiency, and pulse arrival time. Because of the early termination of mission operations, we needed to extract the maximum information from observations performed only days into the mission when the onboard calibration sources had not yet been commissioned and the dewar was still coming into thermal equilibrium, so our technique for reconstructing the per-pixel time-dependent pulse height–energy relation had to be modified. The gain scale was reconstructed using a combination of an absolute energy scale calibration at a single time using a fiducial from an onboard radioactive source and calibration of a dominant time-dependent gain drift component using a dedicated calibration pixel, as well as a residual time-dependent variation using spectra from the Perseus cluster of galaxies. The energy resolution was also measured using the onboard radioactive sources. It is consistent with instrument-level measurements accounting for the modest increase in noise due to spacecraft systems interference. We use observations of two pulsar wind nebulae to validate our models of the telescope area and detector efficiency and to derive a more accurate value for the thickness of the gate-valve Be window, which had not been opened by the time mission operations ceased. We use observations of the Crab nebula to refine the pixel-to-pixel timing and validate the absolute timing.

79 ASTRONOMY AND ASTROPHYSICS↗

Plasmonic photoconductive terahertz focal-plane array with pixel super-resolution

Abstract Imaging systems operating in the terahertz part of the electromagnetic spectrum are attractive due to their ability to penetrate many opaque materials and provide unique spectral signatures of various chemicals. However, the use of terahertz imagers in real-world applications has been limited by the slow speed, large size, high cost and complexity of present systems, largely due to the lack of suitable terahertz focal-plane array detectors. Here we report a terahertz focal-plane array that can directly provide the spatial amplitude and phase distributions, along with the ultrafast temporal and spectral information of an imaged object. It consists of a two-dimensional array of ~0.3 million plasmonic photoconductive nanoantennas optimized to rapidly detect broadband terahertz radiation with a high signal-to-noise ratio. We utilized the multispectral nature of the amplitude and phase data captured by these plasmonic nanoantennas to image different objects, including super-resolved etched patterns in a silicon substrate and defects in battery electrodes. By eliminating the need for raster scanning and spatial terahertz modulation, our terahertz focal-plane array offers more than a 1,000-fold increase in the imaging speed compared with the state of the art and potentially suits a broad range of applications in industrial inspection, security screening and medical diagnosis, among others.

Optics↗

Embedded FPGA developments in 130 nm and 28 nm CMOS for machine learning in particle detector readout

Embedded field programmable gate array (eFPGA) technology allows the implementation of reconfigurable logic within the design of an application-specific integrated circuit (ASIC). This approach offers the low power and efficiency of an ASIC along with the ease of FPGA configuration, particularly beneficial for the use case of machine learning in the data pipeline of next-generation collider experiments. An open-source framework called "FABulous" was used to design eFPGAs using 130 nm and 28 nm CMOS technology nodes, which were subsequently fabricated and verified through testing. The capability of an eFPGA to act as a front-end readout chip was assessed using simulation of high energy particles passing through a silicon pixel sensor. A machine learning-based classifier, designed for reduction of sensor data at the source, was synthesized and configured onto the eFPGA. A successful proof-of-concept was demonstrated through reproduction of the expected algorithm result on the eFPGA with perfect accuracy. Finally, further development of the eFPGA technology and its application to collider detector readout is discussed.

47 OTHER INSTRUMENTATION↗

Rapid Monte Carlo simulation of detector DQE(f)

Purpose: Performance optimization of indirect x-ray detectors requires proper characterization of both ionizing (gamma) and optical photon transport in a heterogeneous medium. As the tool of choice for modeling detector physics, Monte Carlo methods have failed to gain traction as a design utility, due mostly to excessive simulation times and a lack of convenient simulation packages. The most important figure-of-merit in assessing detector performance is the detective quantum efficiency (DQE), for which most of the computational burden has traditionally been associated with the determination of the noise power spectrum (NPS) from an ensemble of flood images, each conventionally having 10{sup 7} − 10{sup 9} detected gamma photons. In this work, the authors show that the idealized conditions inherent in a numerical simulation allow for a dramatic reduction in the number of gamma and optical photons required to accurately predict the NPS. Methods: The authors derived an expression for the mean squared error (MSE) of a simulated NPS when computed using the International Electrotechnical Commission-recommended technique based on taking the 2D Fourier transform of flood images. It is shown that the MSE is inversely proportional to the number of flood images, and is independent of the input fluence provided that the input fluence is above a minimal value that avoids biasing the estimate. The authors then propose to further lower the input fluence so that each event creates a point-spread function rather than a flood field. The authors use this finding as the foundation for a novel algorithm in which the characteristic MTF(f), NPS(f), and DQE(f) curves are simultaneously generated from the results of a single run. The authors also investigate lowering the number of optical photons used in a scintillator simulation to further increase efficiency. Simulation results are compared with measurements performed on a Varian AS1000 portal imager, and with a previously published simulation performed using clinical fluence levels. Results: On the order of only 10–100 gamma photons per flood image were required to be detected to avoid biasing the NPS estimate. This allowed for a factor of 10{sup 7} reduction in fluence compared to clinical levels with no loss of accuracy. An optimal signal-to-noise ratio (SNR) was achieved by increasing the number of flood images from a typical value of 100 up to 500, thereby illustrating the importance of flood image quantity over the number of gammas per flood. For the point-spread ensemble technique, an additional 2× reduction in the number of incident gammas was realized. As a result, when modeling gamma transport in a thick pixelated array, the simulation time was reduced from 2.5 × 10{sup 6} CPU min if using clinical fluence levels to 3.1 CPU min if using optimized fluence levels while also producing a higher SNR. The AS1000 DQE(f) simulation entailing both optical and radiative transport matched experimental results to within 11%, and required 14.5 min to complete on a single CPU. Conclusions: The authors demonstrate the feasibility of accurately modeling x-ray detector DQE(f) with completion times on the order of several minutes using a single CPU. Convenience of simulation can be achieved using GEANT4 which offers both gamma and optical photon transport capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Elemental X-ray Imaging Using the Maia Detector Array: The Benefits and Challenges of Large Solid-Angle

The fundamental parameter method for quantitative SXRF and PIXE analysis and imaging using the dynamic analysis method is extended to model the changing X-ray yields and detector sensitivity with angle across large detector arrays. The method is implemented in the GeoPIXE software and applied to cope with the large solid-angle of the new Maia 384 detector array and its 96 detector prototype developed by CSIRO and BNL for SXRF imaging applications at the Australian and NSLS synchrotrons. Peak-to-background is controlled by mitigating charge-sharing between detectors through careful optimization of a patterned molybdenum absorber mask. A geological application demonstrates the capability of the method to produce high definition elemental images up to {approx}100 M pixels in size.

43 PARTICLE ACCELERATORS↗

The SparkPix-S ASIC for the sparsified readout of 1 MHz frame-rate X-ray cameras at LCLS-II: pixel design and simulation results

Exploiting the “sparse” nature of the information in XPCS (X-ray Photon Correlation Spectroscopy) and XSVS (Speckle Visibility Spectroscopy) experiments, we present the SparkPix-S, a 3-sides buttable Application Specific Integrated Circuit (ASIC) based on a sparsified readout strategy for large-format hybrid detectors. The SparkPix-S architecture, based on the successful ePix family, will be composed as follows: a front-end 2-D matrix of 384×352 square pixels with 50 µm pitch is arranged to match the dimensions of a PIN Si-sensor matrix; charge readout, signal shaping and amplitude discrimination is performed at pixel-level, by means of a low-power (<18 µW) analog processor, which, in case of an event, negotiates access to an analog bus placed every other column; on the chip periphery (balcony), the information on each bus is digitized by an array of successive approximation analog-to-digital converters (SAR-ADCs) running at 10 Msps; on the digital back-end the global logic will generate the output data stream using low-voltage differential signalling (LVDS). A first prototype of the SparkPix-S, with a reduced matrix size of 96×96 pixels, is currently under production on a 130 nm CMOS technology. Simulated performance results show an equivalent noise charge <60 el. r.m.s. at 1 MHz repetition rate, with a maximum input energy of 60 keV and capability to discriminate charge signals with equivalent energy as low as 900 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hierarchical Phased-Array Antennas Coupled to Al KIDs: A Scalable Architecture for Multi-band Millimeter/Submillimeter Focal Planes

We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors and aluminum inductors. The incoming light is received with a hierarchical phased array of slot dipole antennas, split into 4 frequency bands (between 125 GHz and 365 GHz) with on-chip lumped-element band-pass filters, and routed to different KIDs using microstriplines. Individual pixels detect light for the 3 higher-frequency bands (190–365 GHz), and the signals from four individual pixels are coherently summed to create a larger pixel detecting light for the lowest frequency band (125–175 GHz). The spectral response of the band-pass filters was measured using Fourier transform spectroscopy (FTS), the far-field beam pattern of the phased-array antennas was obtained using an infrared source mounted on a 2-axis translating stage, and the optical efficiency of the KIDs was characterized by observing loads at 294 K and 77 K. We report on the results of these three measurements.

47 OTHER INSTRUMENTATION↗

Design Methodology: ASICs with complex in-pixel processing for Pixel Detectors

The development of Application Specific Integrated Circuits (ASIC) for pixel detectors with complex in-pixel processing using Computer Aided Design (CAD) tools that are, themselves, mainly developed for the design of conventional digital circuits requires a specialized approach. Mixed signal pixels often require parasitically aware detailed analog front-ends and extremely compact digital back-ends with more than 1000 transistors in small areas below 100μm x 100μm. These pixels are tiled to create large arrays, which have the same clock distribution and data readout speed constraints as in, for example, micro-processors. The methodology uses a modified mixed-mode on-top digital implementation flow to not only harness the tool efficiency for timing and floor-planning but also to maintain designer control over compact parasitically aware layout.

43 PARTICLE ACCELERATORS↗

Segmented Monolithic Germanium Detector Arrays for X-ray Absorption Spectroscopy

The experimental results from the Phase I effort were extremely encouraging. During Phase I PHDs Co. made the first strides toward a new detector technology that could have great impact on synchrotron x-ray absorption (XAS) measurements, and x-ray detector technology in general. Detector hardware that allowed critical demonstration measurements of our technology was designed and fabricated. This new technology allows good charge collection from many pixels on a single side of a multi-element monolithic germanium planar detector. The detector technology provides “dot-like” collection electrodes having very low capacitance. The detector technology appears to perform as anticipated in the Phase I proposal. In particular, the 7-pixel detector studied showed remarkable properties; making it an interesting example of detector physics. The technology is enabled by the use of amorphous germanium contact technology on germanium planar detectors. Because of the scalability associated with the fabrication of these technologies at PHDs Co., we anticipate being able to supply larger detector systems at significantly lower cost than systems made in the conventional manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-91: Novel Epitaxial Silicon Array for Quality Assurance in Photon and Proton Therapy

Purpose: to demonstrate suitability of a novel silicon array for measuring the dose properties of highly conformal photon and proton beams. Methods: prototype under test is a 24cm long linear array prototype, although the underlying technology is suitable to construct 2D arrays as well. It is based on a 64pixels monolithic sensor with 1mm pixel pitch, made of epitaxial ptype silicon. Thanks to design modularity, more sensors can be placed side by side without breaking pixel pitch. Flattened and unflattened photon beams, as well as proton radiation from a cyclotron in pencil beam scanning mode, were considered. Measurements of beam characteristics as percentage depth doses, dose profiles, output factors and energy response, which are necessary to deliver radiation with high precision and reliability, were performed. Results: Dose rate independence with photons was verified in the dose per pulse range 0.03 to 2mGy. Results clearly indicate nondependence of the detector sensitivity both for flattened and unflattened beams, with a variation of at most 0.5percentage. OFs were obtained for field with a lateral size ranging from 0.8cm to 16cm and the results are in good agreement with ion chamber A1SL, max difference less than 1.5percentage. Field sizes and beam penumbra were measured and compared to EBT film results. Concerning proton beams, sensitivity independence on dose rate was verified by changing the beam current in the interval 2-130Gy/s. Field sizes and beam penumbra measurements are in agreement with data taken with a scintillating 2D array with 0.5mm resolution IBA Lynx, and a better penumbra definition than an array of ionization chambers IBA MatriXX is reached. Conclusion: The device is a novel and valuable tool for QA both for photon and proton dose delivery. All measurements demonstrated its capability to measure with high spatial resolution many crucial properties of the RT beam.

07 ISOTOPE AND RADIATION SOURCES↗

Neuro-Spark: A Submicrosecond Spiking Neural Networks Architecture for In-Sensor Filtering

Neuro-Spark, which is a new neuromorphic architecture with a field-programmable gate array (FPGA) implementation for ultrafast spiking neural network (SNN) inference at the edge, facilitates smart-pixel in-sensor filtering for high-energy physics experiments at the Large Hadron Collider (LHC). Utilizing the evolutionary optimization for neuromorphic systems (EONS) training method, we generate compact SNN models with 91% signal efficiency, akin to convolutional neural networks but with half the parameters. However, deploying near the detector poses a challenge because the SNN must handle a sustained input data rate exceeding 1013 GB/s. To overcome this, we propose a novel hardware architecture that uses high-level synthesis to construct a tuned architecture for the EONS-trained SNN. In addition to the analysis and validation with an AMD Xilinx Artix-A7 FPGA, our solution consumes only ç24% of FPGA LUT and flipflops. We also introduce an innovative quantization method that reduces FPGA resource utilization by ç15% without compromising accuracy. Our FPGA implementation achieves computing latency of ç10 ns for smart-pixel application inference on an edge FPGA.

Miniskar, Narasinga Rao↗

A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science

We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.

47 OTHER INSTRUMENTATION↗

Thermal Links and Microstrip Transmission Lines in SPT-3G Bolometers

In this work, we have measured the properties of membrane-suspended bolometer thermal links and microstrip transmission lines in the transition-edge sensor arrays for the third-generation camera for South Pole Telescope (SPT-3G). A promising technique for controlling the end point of the release etch that defines the thermal link has been developed. We have also evaluated the microstrip loss in our detectors by measuring the optical efficiency of detectors with different lengths of microstrip line. The loss tangent is sufficiently low for the use in multi-chronic pixels for cosmic microwave background instruments like SPT-3G.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Even Higher-Level Synthesis: An Exploration of AI Hardware Accelerators using HLS4ML

With the rise of artificial intelligence, the popularization of deep learning, and a constantly evolving industry, the demand for flexible and efficient tools has never been greater. As algorithms grow more complex, their runtime and energy consumption increase exponentially. Customized hardware accelerators, long used for specific mathematical operations, remain essential for managing modern applications' computational and power demands. Hardware accelerators can speed up complex computations by orders of magnitude, but their manual design and verification processes are often challenging and time-consuming. High-Level Synthesis (HLS) provides a solution by transforming high-level algorithm descriptions, typically written in C++ or SystemC, into synthesizable RTL suitable for hardware implementation. This approach reduces development time for RTL engineers while offering flexibility beyond what traditional handwritten RTL can provide. We extended this capability to the machine-learning domain with the open-source framework hls4ml, which allows neural networks trained in Python frameworks like Tensorflow or PyTorch to be synthesized into efficient hardware representations for the traditional FPGA and ASIC flows. This breakthrough addresses the growing need for reduced design turnaround and easy verification of ML hardware accelerators with low latency and power efficiency constraints. During this tutorial, we will demonstrate how Python complements HLS by simplifying the ML design process, bridging the gap between software and hardware development. Attendees will explore how we translate neural networks modeled in Python into fixed-point C++ models suitable for HLS workflows. We will dive into strategies like Value-Range Analysis and Quantization-Aware Training, which optimize these designs for deployment and evaluate their accuracy, power consumption, and energy efficiency. To exemplify these concepts, experts from Fermilab will share their experiences applying this technology to high-energy physics experiments, where real-time, low-latency processing is critical. Over the years, Fermilab engineers have demonstrated how deep neural networks, optimized for hardware using hls4ml, can meet the stringent requirements of trigger systems at the CERN Large Hadron Collider. These systems rely on rapid decision-making to process immense data volumes while retaining only the most relevant events for further analysis. The application of hls4ml has also been extended to innovative technologies like smart pixel arrays. These smart pixels integrate ML inference capabilities directly into sensor devices, enabling localized data processing at the pixel level. This approach drastically reduces the need to transmit raw data to external processing units, significantly decreasing power consumption and latency. By embedding neural networks within the pixel architecture, the smart pixels can identify and prioritize relevant data in real time, providing a highly efficient solution for edge computing in scenarios such as particle detectors and imaging systems. Fermilab's work highlights the potential of hardware-accelerated ML in scenarios where both speed and power efficiency are mission-critical. Through this tutorial, attendees will gain valuable insights into the challenges and solutions of deploying ML in hardware. Understanding how HLS and hls4ml streamline the development of neural network-based hardware accelerators is fundamental for the industry's future. Participants will learn how these technologies are shaping the future of AI and scientific computing.

Di Guglielmo, Giuseppe [Fermilab]↗

Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. As a result, the completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗