Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Profile Images and Annotations for Vehicle Re-identification Algorithms (PRIMAVERA)

This dataset contains 636,246 profile images of vehicles representing 13,963 unique vehicles. The data was collected by a set of roadside sensors over the course of three years. Each time a vehicle passed by one of the sensors, a series of images was collected. The images were processed to detect and localize each vehicle, and a license plate reader collocated with the sensor was used to provide a unique ID for the vehicle. Actual license plate numbers have been obfuscated by replacing with an arbitrary numerical ID for each vehicle. After localizing the vehicle in each image, the original RGB image was rotated, scaled, and shifted to produce a new RGB image of size 234x234 pixels such that the outermost two wheels are located at predetermined pixel locations in the image. In this way, all vehicle images are aligned to one another. This registration process occasionally results in a portion of certain vehicles being cutoff at the edges of the image. The dataset has been partitioned into two sets called training and validation. The two partitions no common vehicles, i.e., a vehicle present in one partition is guaranteed not to be present in the other. In this way, an algorithm can be validated against a set of new vehicles that were not seen during the training process. The training set contains 543,926 images from 64,440 vehicle passes representing 11,918 unique vehicles, while the validation set contains 92,320 images from 10,991 vehicle passes representing 2,045 unique vehicles. Vehicle images are organized by directories corresponding to unique vehicles. The file naming scheme is as follows: veh_{vehID}_tr_{passID}_{frameID}_{elevation}_{timeofday}.jpg where {vehID} is the vehicle ID (unique across the entire dataset), {passID} is an identifier for each tracked vehicle pass (unique across the entire dataset), {frameID} is the index of the frame within the given vehicle pass starting at 0, {elevation} is a two-letter string indicating whether the sensor was elevated (el) or at ground-level (gl), and {timeofday} is a two-letter string indicating whether the image was captured during daytime (dt) or nighttime (nt).

image↗

The SiD Digital ECal Based on Monolithic Active Pixel Sensors

The SiD detector concept capitalizes on high granularity in its tracker and calorimeter to achieve the momentum resolution and particle flow calorimetry physics goals in a compact design. The collaboration has had a long interest in the potential for improved granularity in both the tracker and ECal with an application of monolithic active pixel sensors (MAPS) and a study of MAPS in the SiD ECal was described in the ILC TDR. Work is progressing on the MAPS application in an upgraded SiD design with a prototyping design effort for a common SiD tracker/ECal design based on stitched reticules to achieve 10 × 10 cm2 sensors with 25 × 100 micron2 pixels. Application of large area MAPS in these systems would limit delicate and expensive bump-bonding, provide possibilities for better timing, and should be significantly cheaper than the TDR concept due to being a more conventional CMOS foundry process. The small pixels significantly improve shower separation. Recent simulation studies confirm previous performance projections, indicating electromagnetic energy resolution based on digital hit cluster counting provides better performance than the SiD TDR analog design based on 13 mm2 pixels. Furthermore, the two shower separation is excellent down to the millimeter scale. Geant4 simulation results demonstrate these expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Delineation of soil temperature regimes from HCMM data

Supplementary data including photographs as well as topographic, geologic, and soil maps were obtained and evaluated for ground truth purposes and control point selection. A study area (approximately 450 by 450 pixels) was subset from LANDSAT scene No. 2477-17142. Geometric corrections and scaling were performed. Initial enhancement techniques were initiated to aid control point selection and soils interpretation. The SUBSET program was modified to read HCMM tapes and HCMM data were reformated so that they are compatible with the ORSER system. Initial NMAP products of geometrically corrected and scaled raw data tapes (unregistered) of the study were produced.

Day, R. L.↗

A CCD System for Photometry of Direct and Spectroscopic Images

A charge-coupled device (CCD) for direct imagery at the focus of a ground-based telescope and for high dispersion spectroscopy of stars is evaluated. The CCD is an RCA SID 53612 thinned, buried channel array of 512x320 30-micron square pixels that are back-illuminated and refrigerated to about -60 C in a rugged, RF-shielded vacuum housing. The double-correlated sampling (integrator) readout system, the Z80 microprocessor readout control system, and the data collection system are described. The readout noise is 120 electron-hole pairs (ehp) per pixel per readout, the thermal dark current is 50 ehp/pixel/sec, and the scale of the 12-bit analog-to-digital converter is 25 ehp/AD unit. Unique features of this system are compared to other astronomical implementations of the same model of CCD.

Frecker, J. E.↗

The Extended Range X-Ray Telescope center director's discretionary fund report

An Extended Range X-Ray Telescope (ERXRT) of high sensitivity and spatial resolution capable of functioning over a broad region of the X-ray/XUV portion of the spectrum has been designed and analyzed. This system has been configured around the glancing-incidence Wolter Type I X-ray mirror system which was flown on the Skylab Apollo Telescope Mount as ATM Experiment S-056. Enhanced sensitivity over a vastly broader spectral range can be realized by the utilization of a thinned, back-illuminated, buried-channel Charge Coupled Device (CCD) as the X-ray/XUV detector rather than photographic film. However, to maintain the high spatial resolution inherent in the X-ray optics when a CCD of 30 micron pixel size is used, it is necessary to increase the telescope plate scale. This can be accomplished by use of a glancing-incidence X-ray microscope to enlarge and re-focus the primary image onto the focal surface of the CCD.

Hoover, R. B.↗

An IDL-based analysis package for COBE and other skycube-formatted astronomical data

UIMAGE is a data analysis package written in IDL for the Cosmic Background Explorer (COBE) project. COBE has extraordinarily stringent accuracy requirements: 1 percent mid-infrared absolute photometry, 0.01 percent submillimeter absolute spectrometry, and 0.0001 percent submillimeter relative photometry. Thus, many of the transformations and image enhancements common to analysis of large data sets must be done with special care. UIMAGE is unusual in this sense in that it performs as many of its operations as possible on the data in its native format and projection, which in the case of COBE is the quadrilateralized sphereical cube ('skycube'). That is, after reprojecting the data, e.g., onto an Aitoff map, the user who performs an operation such as taking a crosscut or extracting data from a pixel is transparently acting upon the skycube data from which the projection was made, thereby preserving the accuracy of the result. Current plans call for formatting external data bases such as CO maps into the skycube format with a high-accuracy transformation, thereby allowing Guest Investigators to use UIMAGE for direct comparison of the COBE maps with those at other wavelengths from other instruments. It is completely menu-driven so that its use requires no knowledge of IDL. Its functionality includes I/O from the COBE archives, FITS files, and IDL save sets as well as standard analysis operations such as smoothing, reprojection, zooming, statistics of areas, spectral analysis, etc. One of UIMAGE's more advanced and attractive features is its terminal independence. Most of the operations (e.g., menu-item selection or pixel selection) that are driven by the mouse on an X-windows terminal are also available using arrow keys and keyboard entry (e.g., pixel coordinates) on VT200 and Tektronix-class terminals. Even limited grey scales of images are available this way. Obviously, image processing is very limited on this type of terminal, but it is nonetheless surprising how much analysis can be done on that medium. Such flexibility has the virtue of expanding the user community to those who must work remotely on non-image terminals, e.g., via modem.

Ewing, J. A.↗

Image quality measures and their performance

A number of quality measures are evaluated for gray scale image compression. They are all bivariate exploiting the differences between corresponding pixels in the original and degraded images. It is shown that although some numerical measures correlate well with the observers' response for a given compression technique, they are not reliable for an evaluation across different techniques. The two graphical measures (histograms and Hosaka plots), however, can be used to appropriately specify not only the amount, but also the type of degradation in reconstructed images.

Eskicioglu, Ahmet M.↗

A CCD offset guider for the KAO

We describe a focal plane guider for the Kuiper Airborne Observatory which consists of a CCD camera interfaced to an AMIGA personal computer. The camera is made by Photometrics Ltd. and utilizes a Thomson 576 x 384 pixel CCD chip operated in Frame Transfer mode. Custom optics produce a scale of 2.4 arc-sec/pixel, yielding an approx. 12 ft. diameter field of view. Chopped images of stars with HST Guide Star Catalog magnitudes fainter than 14 have been used for guiding at readout rates greater than or equal to 0.5 Hz. The software includes automatic map generation, subframing and zooming, and correction for field rotation when two stars are in the field of view.

Colgan, Sean W. J.↗

In Situ Identification of Mineral Resources with an X-Ray-Optical "Hands-Lens" Instrument

The recognition of material resources on a planetary surface requires exploration strategies not dissimilar to those employed by early field geologists who searched for ore deposits primarily from surface clues. In order to determine the location of mineral ores or other materials, it will be necessary to characterize host terranes at regional or subregional scales. This requires geographically broad surveys in which statistically significant numbers of samples are rapidly scanned from a roving platform. To enable broad-scale, yet power-conservative planetary-surface exploration, we are developing an instrument that combines x-ray diffractometry (XRD), x-ray fluorescence spectrometry (XRF), and optical capabilities; the instrument can be deployed at the end of a rover's robotic arm, without the need for sample capture or preparation. The instrument provides XRD data for identification of mineral species and lithological types; diffractometry of minerals is conducted by ascertaining the characteristic lattice parameters or "d-spacings" of mineral compounds. D-spacings of 1.4 to 25 angstroms can be determined to include the large molecular structures of hydrated minerals such as clays. The XRF data will identify elements ranging from carbon (Atomic Number = 6) to elements as heavy as barium (Atomic Number = 56). While a sample is being x-rayed, the instrument simultaneously acquires an optical image of the sample surface at magnifications from lx to at least 50x (200x being feasible, depending on the sample surface). We believe that imaging the sample is extremely important as corroborative sample-identification data (the need for this capability having been illustrated by the experience of the Pathfinder rover). Very few geologists would rely on instrument data for sample identification without having seen the sample. Visual inspection provides critical recognition data such as texture, crystallinity, granularity, porosity, vesicularity, color, lustre, opacity, and so forth. These data can immediately distinguish sedimentary from igneous rocks, for example, and can thus eliminate geochemical or mineral ambiguities arising, say between arkose and granite. It would be important to know if the clay being analyzed was part of a uniform varve deposit laid down in a quiescent lake, or the matrix of a megabreccia diamictite deposited as a catastrophic impact ejecta blanket. The unique design of the instrument, which combines Debye-Scherrer geometry with elements of standard goniometry, negates the need for sample preparation of any kind, and thus negates the need for power-hungry and mechanically-complex sampling systems that would have to chip, crush, sieve, and mount the sample for x-ray analysis. Instead, the instrument is simply rested on the sample surface of interest (like a hand lens); the device can interrogate rough rock surfaces, coarse granular material, or fine rock flour. A breadboard version of the instrument has been deployed from the robotic arm of the Marsokhod rover in field trials at NASA Ames, where large vesicular boulders were x-rayed to demonstrate the functionality of the instrument design, and the ability of such a device to comply with constraints imposed by a roving platform. Currently under development is a flight prototype concept of this instrument that will weigh 0.3 kg, using about 4500 J of energy per sample analysis. It requires about 5 min. for XRD analysis, and about 30 min. for XRF interrogation. Its small mass and rugged design make it ideal for deployment on small rovers of the type currently envisaged for the exploration of Mars (e.g., Sojourner-scale platforms). The design utilizes a monolithic P-N junction photodiode pixel array for XRD, a Si PIN photodiode/avalanche photodiode system for XRF, and an endoscopic imaging camera system unobtrusively embedded between the detectors and the x-ray source (the endoscope with its board-mounted camera can be adapted for IR light in addition to visible wavelenths. A rugged, miniature (7 cu cm) x-ray source for the instrument has already been breadboarded.

Marshall, J.↗

On-Orbit Calibration of ADEOS OCTS with an AVIRIS Underflight

The Ocean Color Temperature Scanner (OCTS) onboard the Advanced Earth Observation Satellite (ADEOS) was launched on August 17, 1996. Calibration of OCTS is required for use of the on-orbit measured data for retrieval of physical properties of the ocean. In the solar reflected portion of the electromagnetic spectrum, OCTS measures images with nominally 700-m spatial resolution through eight multispectral bands. The objective of this research was to establish the absolute radiometric calibration of OCTS on orbit through an underflight by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS is a NASA earth-observing imaging spectrometer designed, built and operated by the Jet Propulsion Laboratory (JPL). AVIRIS acquires data from 20-km altitude on a NASA ER-2 aircraft, above most of the Earth's atmosphere. AVIRIS measures the solar reflected spectrum from 370 nm to 2500 nm through 224 contiguous spectral channels. The full width at half maximum (FWHM) of the spectral channels is nominally 10-nm. AVIRIS spectra are acquired as images of 11 km by up to 800 km extent with 20-m spatial resolution. The high spectral resolution of AVIRIS data allows direct convolution to the spectral response functions of the eight multispectral bands of OCTS. The high spatial resolution of AVIRIS data allows for spatial re-sampling of the data to match the ADEOS sensors spatial resolution. In addition, the AVIRIS high spatial resolution allows assessment of the scaling effects due to environmental factors of thin cirrus clouds, sub-pixel cloud cover, white caps, ocean foam, sun-glint, and bright-target adjacency. The platform navigation information recorded by AVIRIS allows calculation of the position and observation geometry of each spectrum for matching to the OCTS measurement. AVIRIS is rigorously characterized and calibrated in the laboratory prior to and following the flight season. The stability and repeatability of AVIRIS calibration have been validated through an extensive series of inflight calibration experiments. In the OCTS portion of the spectrum, using pre-and post-flight runway calibrations of AVIRIS coupled with the on-board calibrator an absolute calibration accuracy of better than 3% spectral, 2% radiometric and 5% spatial has been achieved. An analogous satellite underflight calibration experiment was performed with AVIRIS and the Optical Sensor (OPS) onboard the Japanese Earth Resources Satellite (JERS).

Green, Robert O.↗

On-Orbit Calibration of ADEOS OCTS with an AVIRIS Underflight

The Ocean Color Temperature Scanner (OCTS) onboard the Advanced Earth Observation Satellite (ADEOS) was launched on August 17, 1996. Calibration of OCTS is required for use of the on-orbit measured data for retrieval of physical properties of the ocean. In the solar reflected portion of the electromagnetic spectrum, OCTS measures images with nominally 700-m spatial resolution through eight multispectral bands. The objective of this research was to establish the absolute radiometric calibration of OCTS on orbit through an underflight by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS is a NASA Earth-observing imaging spectrometer designed, built and operated by the Jet Propulsion Laboratory (JPL). AVIRIS acquires data from 20-km altitude on a NASA ER-2 aircraft, above most of the Earth's atmosphere. AVIRIS measures the solar reflected spectrum from 370 nm to 2500 nm through 224 contiguous spectral channels. The full width at half maximum (FWHM) of the spectral channels is nominally 10-nm. AVIRIS spectra are acquired as images of 11 km by up to 800 km extent with 20-m spatial resolution. The high spectral resolution of AVIRIS data allows direct convolution to the spectral response functions of the eight multispectral bands of OCTS. The high spatial resolution of AVIRIS data allows for spatial re-sampling of the data to match the ADEOS sensors spatial resolution. In addition, the AVIRIS high spatial resolution allows assessment of the scaling effects due to environmental factors of thin cirrus clouds, sub-pixel cloud cover, white caps, ocean foam, sun-glint, and bright-target adjacency. The platform navigation information recorded by AVIRIS allows calculation of the position and observation geometry of each spectrum for matching to the OCTS measurement. AVIRIS is rigorously characterized and calibrated in the laboratory prior to and following the flight season. The stability and repeatability of AVIRIS calibration have been validated through an extensive series of inflight calibration experiments. In the OCTS portion of the spectrum, using pre- and post-flight runway calibrations of AVIRIS coupled with the on-board calibrator an absolute calibration accuracy of better than 3% spectral, 2% radiometric, and 5% spatial, has been achieved. An analogous satellite underflight calibration experiment was performed with AVIRIS and the Optical Sensor (OPS) onboard the Japanese Earth Resources Satellite (JERS).

Green, Robert O.↗

Recent Developments in Transition-Edge Strip Detectors for Solar X-Rays

LMSAL and NIST are developing position-sensitive x-ray strip detectors based on Transition Edge Sensor (TES) microcalorimeters optimized for solar physics. By combining high spectral (E/ delta E approximately equals 1600) and temporal (single photon delta t approximately equals 10 micro s) resolutions with imaging capabilities, these devices will be able to study high-temperature (>l0 MK) x-ray lines as never before. Diagnostics from these lines should provide significant new insight into the physics of both microflares and the early stages of flares. Previously, the large size of traditional TESs, along with the heat loads associated with wiring large arrays, presented obstacles to using these cryogenic detectors for solar missions. Implementing strip detector technology at small scales, however, addresses both issues: here, a line of substantially smaller effective pixels requires only two TESs, decreasing both the total array size and the wiring requirements for the same spatial resolution. Early results show energy resolutions of delta E(sub fwhm) approximately equals 30 eV and spatial resolutions of approximately 10-15 micron, suggesting the strip-detector concept is viable.

Rausch, Adam J.↗

Object-Based Mapping of the Circumpolar Taiga-Tundra Ecotone with MODIS Tree Cover

The circumpolar taiga tundra ecotone was delineated using an image-segmentation-based mapping approach with multi-annual MODIS Vegetation Continuous Fields (VCF) tree cover data. Circumpolar tree canopy cover (TCC) throughout the ecotone was derived by averaging MODIS VCF data from 2000 to 2005 and adjusting the averaged values using linear equations relating MODIS TCC to Quickbird-derived tree cover estimates. The adjustment helped mitigate VCF's overestimation of tree cover in lightly forested regions. An image segmentation procedure was used to group pixels representing similar tree cover into polygonal features (segmentation objects) that form the map of the transition zone. Each polygon represents an area much larger than the 500 m MODIS pixel and characterizes the patterns of sparse forest patches on a regional scale. Those polygons near the boreal/tundra interface with either (1) mean adjusted TCC values from5 to 20%, or (2) mean adjusted TCC values greater than 5% but with a standard deviation less than 5% were used to identify the ecotone. Comparisons of the adjusted average tree cover data were made with (1) two existing tree line definitions aggregated for each 1 degree longitudinal interval in North America and Eurasia, (2) Landsat-derived Canadian proportion of forest cover for Canada, and (3) with canopy cover estimates extracted from airborne profiling lidar data that transected 1238 of the TCC polygons. The adjusted TCC from MODIS VCF shows, on average, less than 12% TCC for all but one regional zone at the intersection with independently delineated tree lines. Adjusted values track closely with Canadian proportion of forest cover data in areas of low tree cover. A comparison of the 1238 TCC polygons with profiling lidar measurements yielded an overall accuracy of 67.7%.

Ranson, K. J.↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Distributed Automatic Differentiation for Ptychography

Synchrotron radiation light source facilities are leading the way to ultrahigh resolution X-ray imaging. High resolution imaging is essential to understanding the fundamental structure and interaction of materials at the smallest length scale possible. Diffraction based methods achieve nanoscale imaging by replacing traditional objective lenses by pixelated area detectors and computational image reconstruction. Among these methods, ptychography is quickly becoming the standard for sub-30 nanometer imaging of extended samples, but at the expense of increasingly high data rates and volumes. This paper presents a new distributed algorithm for solving the ptychographic image reconstruction problem based on automatic differentiation. Input datasets are subdivided between multiple graphics processing units (GPUs); each subset of the problem is then solved either entirely independent of other subsets (asynchronously) or through sharing gradient information with other GPUs (synchronously). The algorithm was evaluated on simulated and real data acquired at the Advanced Photon Source, scaling up to 192 GPUs. The synchronous variant of our method outperformed an existing multi-GPU implementation in terms of accuracy while running at a comparable execution time.

distributed algorithms↗

Conversion of a Micro-CT Scanned Rock Fracture Into a Useful Model

Within geologic reservoirs the flow of fluids through fractures is often orders of magnitude greater than through the surrounding, low-permeability rock. Because of the number and size of fractures in geological fields, reservoir-scale discrete-fracture simulators often model fluid motion through fractures as flow through narrow, parallel plates. In reality fractures within rock are narrow openings between two rough rock surfaces. In order to model the geometry of an actual fracture in rock, a ~9 cm by 2.5 cm fracture within Berea sandstone was created and the aperture distribution was obtained with micro-Computed Tomography (CT) scans by Karpyn et al. [1]. The original scans had a volume-pixel (voxel) resolution of 27 by 27 by 32 microns. This data was up-scaled to voxels with 120 microns to a side to facilitate data transfer and for practicality of use. Using three separate reconstruction techniques, six different fracture meshes were created from this up-scaled data set, each with slightly different final geometries. Flow through each of these fracture meshes was evaluated using the finite-volume simulator FLUENT. While certain features of the fracture meshes, such as the shape of the fracture aperture distributions and overall volume of the void, remained similar between the different geometric reconstructions, the flow in different models was observed to vary dramatically. Rough fracture walls induced more tortuous flow paths and a higher resistance to flow. Natural fractures do vary in-situ, due to sidewall dissolution and mineral precipitation, smoothing and coarsening fracture walls respectively. Thus for our study the range of fracture properties was actually beneficial, allowing us to describe the flow through a range of fracture types. A compromise between capturing the geometric details within a domain of interest and a tractable computational mesh must always be addressed when flow through a physical geometry is modeled. The fine level of detail that is currently available from micro-CT scanning equipment can compound this problem. This study evaluates several methods of obtaining rational CFD meshes from a complex physical geometry, and discusses the benefits and disadvantages of the different procedures as they pertain to flow through a natural fracture in rock.

54 ENVIRONMENTAL SCIENCES↗

Landscape-scale characterization of Arctic tundra vegetation composition, structure, and function with a multi-sensor unoccupied aerial system

The Arctic is experiencing some of the most rapid climate change on Earth, with strong impacts on tundra ecosystems that are characterized by high land-surface and vegetation heterogeneity. Previous studies have explored this complexity using satellite remote sensing, however these typically coarse spatial resolution data have generally missed sub-pixel heterogeneity, leaving critical gaps in our understanding of tundra vegetation dynamics from the community to landscape scales. To address these gaps, we collected very high-resolution (1-5 cm) optical, structural, and thermal data at three low-Arctic tundra sites on the Seward Peninsula, Alaska, using a multi-sensor unoccupied aerial system (UAS). We examined the application of these data to studying tundra vegetation dynamics, by quantifying (1) canopy height and thermoregulation (leaf-air temperature) of representative plant functional types (PFTs), (2) fine-scale patterns of vegetation composition across landscapes, and (3) impacts of fine-scale vegetation composition on landscape-scale variation of canopy height and thermoregulation. Our results show that deciduous tall shrubs (those that can potentially grow >2 m) had a strong cooling effect, with canopy temperatures significantly lower than local air temperatures and other PFTs. Increased cover of tall shrubs also had the potential to reduce the cover of low-stature PFTs across the landscape, potentially associated with their closed canopy (i.e., increased light competition) and strong thermoregulation. To understand the connections between fine-scale vegetation composition and large-scale ecosystem processes, we produced a random forest model which showed that fine-scale PFT composition accounted for 86.8% and 74.2% of the landscape-scale variation in canopy height and thermoregulation, respectively. These findings highlight the importance of spatially detailed characterization of tundra PFTs to improve our ecological understanding and model representation of tundra vegetation, also transcend our study to show the need for continued collection of similar datasets to better understand the impacts of surface heterogeneity on the mapping and modeling of tundra ecosystem dynamics, as well as assist with conservation management and biodiversity monitoring strategies.

54 ENVIRONMENTAL SCIENCES↗

What lies beneath: Vertical temperature heterogeneity in a Mediterranean woodland savanna

As the availability of satellite and airborne thermal infrared remote sensing (TIR-RS) data increases and their spatial, temporal, and spectral resolutions improve, researchers are finding diverse applications for TIR-RS measurements. TIR-RS is now commonly applied in regional- and continental-scale analyses, such as those focused on fire and surface energy balance. However, its application lags in plant physiology and ecology, for which a finer-scale understanding of plant canopy temperatures would be useful to elucidate plant water dynamics, for example. In particular, while methods to disaggregate TIR-RS pixels in horizontal space have advanced, possible vertical stratification of plant canopy temperature and its implications for understanding the correspondence between TIR-RS and finer-scale, field-based thermal measurements (e.g. made with a thermal camera) remain unexplored. Here, we use data from a thermal camera deployed concurrently with the recent ECOSTRESS mission to quantify vertical temperature gradients within tree canopies and temperatures of over- vs. under-story plants in a Mediterranean woodland savanna. We then leverage diverse ancillary data to maximize the geometric comparability of ECOSTRESS and thermal camera measurements, in order to assess the extent to which the two forms of thermal measurements correspond. Specifically, we ask: (1) What are the patterns of intra-canopy and over- vs. under-story vertical temperature in a Mediterranean woodland savanna?, and (2) How can vertically-resolved, but spatially-limited field-based temperature measurements be reconciled with spatially-extensive, but surface-only, temperature measurements of a space-borne remote sensor? Further, we found consistent patterns of vertical thermal heterogeneity both within tree canopies and between ecosystem over- and under-stories. The daytime difference between the top and bottom thirds of blue oak canopies was, on average, 0.48 ° C – and sometimes several times larger. Notably, canopy tops are cooler, likely associated with the under-story grass reaching daytime temperatures often exceeding over-story temperatures by 10° C. Given the consistency of the intra-canopy temperature gradients, we expected the ECOSTRESS sensor would be in better agreement with camera measurements of canopy tops than bulk canopies or canopy bottoms. However, within-canopy gradients were overwhelmed by other sources of disagreement between the measurements, in part associated with upscaling camera measurements across space. Overall, thermal camera and ECOSTRESS measurements were largely in agreement at night (pixel RMSE = 1.1°C), but they were more divergent during times of low (but >0 W/m2) and high incoming solar radiation (daytime pixel RMSE = 3.5°C).

54 ENVIRONMENTAL SCIENCES↗