Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Quasilinear Analysis in the Source Region of Jovian Hectometric Emission Associated With Upward Electron Beams

Abstract Intense upward electron beams were measured by the Juno JADE instrument in the northern hemisphere, low‐latitude auroral zone source region. In this study we report on how these electron beams interact with plasma near and within the Jovian hectometric (HOM) emission (1 MHz 5 MHz) source region. Within the source region large upward loss cones are observed in the northern polar region at radial distances of 2Rj, magnetic latitude of . Intense, narrow electron beams ( 3 keV) are then observed, but within one second wave‐particle scattering is observed, filling the loss cone to energies 50 keV. These energies persist for several seconds before fading, leaving an empty loss cone again. The loss cone provides a free‐energy source for HOM emission resulting from the cyclotron maser instability. We use quasilinear analysis to examine the generation of HOM and the dynamics of wave‐particle interaction of the electron beams with HOM, and the generation via Landau interaction of whistler mode emission. The dynamic spectrum of the HOM emission generated by the loss‐cone electrons as well as that of the low‐frequency whistler‐mode waves generated by the up‐going electron beam can be constructed by quasilinear theory, which compare well with observation. The saturated state of the energetic electron velocity distribution function constructed via quasilinear theory also compare reasonably with observation.

Yoon, P. H. [Institute for Physical Science and Te↗

A Large Bore Conduction Cooled Superconducting Magnet for the Princeton Axion Search

Princeton University (PU) is designing and building a new experiment, called the Princeton Axion Search (PXS), that aims to discover (or exclude) Quantum Chromodynamics (QCD) axions in the 0.8–2 μeV mass range that are the cosmological dark matter. Core elements of the experiment are new, and in particular new to the search for axion dark matter. An essential component of the experiment is a 5 T superconducting magnet with a total bore volume of ~500 L. The Princeton Plasma Physics Laboratory (PPPL), a Department of Energy (DOE) Laboratory managed by Princeton University, has the unique expertise and experimental facilities to design and construct such a solenoid magnet assembled with the cavity resonator for PXS. To support this, PPPL utilizes legacy ITER-Nb3Sn conductors, along with its experimental facilities and expertises to design, build and test low-cost conduction-cooled superconducting solenoid magnets to be integrated into the axion detector. This paper discusses the various coil design and integration challenges in the large bore conduction cooled magnet in support of PXS. In conclusion, the proposed instrumental methods will help optimize the path to future and more ambitious axion searches at lower masses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diagnosing an IFE Power Plant

This white paper for the Basic Research Needs for Plasma Diagnostics workshop lists a selected set of measurements required for normal and off-normal operation of an Inertial Fusion Energy power plant. An Inertial Fusion Energy (IFE) power plant will require instruments that record how well it is performing and, more importantly, sufficient instruments to diagnose failures during routine operation. It is assumed in this white paper that operating specifications and tolerances have been established before the plant begins operation so that only a minimal set of instruments is required. A pilot plant (a DEMO) would require more instrumentation in order to set those requirements and tolerances. This white paper assumes a laser-based IFE plant that operates at up to 20 Hz. Two scenarios are considered below. One is for routine, nominal operation and the other is when an implosion fails to produce energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Highly ionized iron absorption structures

We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Laser-Plasma Spectroscopy of Hydroxyl with Applications

This article discusses laser-induced laboratory-air plasma measurements and analysis of hydroxyl (OH) ultraviolet spectra. The computations of the OH spectra utilize line strength data that were developed previously and that are now communicated for the first time. The line strengths have been utilized extensively in interpretation of recorded molecular emission spectra and have been well-tested in laser-induced fluorescence applications for the purpose of temperature inferences from recorded data. Moreover, new experiments with Q-switched laser pulses illustrate occurrence of molecular recombination spectra for time delays of the order of several dozen of microseconds after plasma initiation. The OH signals occur due to the natural humidity in laboratory air. Centrifugal stretching of the Franck-Condon factors and r-centroids are included in the process of determining the line strengths that are communicated as a Supplementary File. Laser spectroscopy applications of detailed OH computations include laser-induced plasma and combustion analyses, to name but two applications. This work also includes literature references that address various diagnosis applications.

47 OTHER INSTRUMENTATION↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Characterization of AGFA D4 and D3sc X-ray films in the 0.7 to 4.6 keV energy range

2020 High Temperature Plasma Diagnostic conference in Los Alamos, NM at LANL (Virtual conference) 12/14/2020-12/17/2020 web link: http://www.cvent.com/events/2020-high-temperatures-conference/event-summary-316fe078c3894ef5ab725d6bbdf69334.aspx This manuscript will appear in Review of Scientific Instruments part of the conference proceeding to the above conference

X-ray, Film, Characterization↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of On-Line Monitoring and Real-Time Characterization of Low Level Waste Samples from Hanford Tanks - 20380

Waste and treatment stream characterization is an essential part of safe, efficient, and cost-effective processing of Hanford materials. The demand for materials characterization, including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms, is expected to significantly increase as the U.S. Department of Energy Office of River Protection (ORP) progresses toward Hanford waste treatment and immobilization. The application of on-line monitoring can greatly improve operation time frames and reduce costs by providing real-time data and supporting the reduction of necessary grab sample collection. Recently, our team applied Raman online monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105, and demonstrated the quantitative measurement of nine analytes within this waste. Application of this method has been expanded to additional Hanford tank wastes, AW-102 and AP-107. The performance of the process monitoring instruments and the accuracy of the chemometric models will be assessed. On-line monitoring results will be compared to anion results determined from the current standard, ion-chromatographic and inductively coupled plasma mass spectrometry methods. Comparisons of both determined values and uncertainties of results will be presented. Results will be shared with personnel working on flowsheet interfaces for the Direct-Feed Low Activity Waste mission at Hanford. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid Cherenkov detector for studying nucleosynthesis in inertial confinement fusion

Measuring gamma rays emitted from nuclear reactions gives insight into their nuclear structure. Notably, there are several nuclear reactions that produce gamma rays at ~1 MeV–3 MeV energies such as T( 4 He, γ) 7 Li, 4 He( 3 He, γ) 7 Be, and 12 C(p, γ) 13 N, which may solve questions lingering about big-bang nucleosynthesis and stellar nucleosynthesis. To observe 1 MeV–3 MeV gamma rays in an inertial confinement fusion system, a new style of the Cherenkov detector was developed using aerogel and fused silica as a Cherenkov medium. Utilizing the OMEGA laser facility, both aerogel and fused silica media were compared with the existing gas-medium Cherenkov detector to validate the concept. Furthermore, gamma ray measurements from high yield inertial confinement fusion implosions (deuterium–tritium and deuterium– 3 He) demonstrated that aerogel and fused silica were viable Cherenkov media, paving the way for a potential optimized detector to make these cross section measurements on OMEGA or the National Ignition Facility.

47 OTHER INSTRUMENTATION↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using a cylindrical-harmonics expansion

Inertial confinement fusion capsule implosions produce neutron, gamma-ray, and x-ray emission, which are recorded by a variety of detectors, both time integrated and time resolved, to determine the performance of the implosion. Further, two-dimensional emission images from multiple directions can now be combined to infer three-dimensional structures in the implosion, such as the distribution of thermonuclear fuel density, carbon ablator, and impurities. Because of the cost and complexity of the imaging systems, however, only a few measurements can be made, so reconstructions of the source must be made from a limited number of views. Here, a cylindrical-harmonics decomposition technique to reconstruct the three-dimensional object from two views in the same symmetry plane is presented. In the limit of zero order, this method recovers the Abel inversion method. The detailed algorithms used for this characterization and the resulting reconstructed neutron source from an experiment collected at the National Ignition Facility are presented.

47 OTHER INSTRUMENTATION↗

Detector thickness effects on nanosecond-gated imager response

Hybrid CMOS multi-frame imagers with exposure times down to ~2 ns have made significant impacts in high energy density physics and inertial confinement fusion research. The detector thickness is a key parameter in both detector quantum efficiency and temporal response. The Icarus hybrid CMOS imager has been fabricated with Si detector thicknesses of 8, 25, and 100 µm. The temporal response of imaging sensors with exposure time down to 2 ns has been examined and compared to directly measured photodiode current. The 100-μm thick variant displays extended features related to charge carrier collection and is more susceptible to field collapse. Here, we also demonstrate charge collection time effects on spatial response.

47 OTHER INSTRUMENTATION↗