Search NASA⌕ Search

SEARCH · Search NASA

Results for “position measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

VLBI measurements of radio source positions at the Jet Propulsion Laboratory

The results of approximately 1300 observations of 67 radio sources are presented. Most of the measurements were made at the stations of the Deep Space Network in California, Spain, and Australia at wavelengths of 13.1 and 3.6 cm, between 1971 and 1978. The formal errors in the derived source positions are generally in the neighborhood of 0.01 seconds of arc and the positions agree fairly well with those previously published.

Purcell, G. H., Jr.↗

Flowmeter measures flow rates of high temperature fluids

Flowmeter in which flow rate is determined by measuring the position and thus the displacement of an internal float acted upon by the flowing fluid determines the flow rates of various liquid metals at elevated temperatures. Viscous forces cause the float to move from its mounted position, affording several means for measuring this motion and the flow rate.

Vary, A.↗

Robotic Target-Tracking Subsystem

Position and orientation of target measured in six degrees of freedom. Robotic vision subsystem measures relative position and orientation of specially designed target. Uses standard image-processing algorithms implemented directly in circuitry instead of computer programs. This feature makes it possible to extract complete sets of target-tracking data from successive image frames at rate of 30 frames per second. Five bright circles of target positioned in such way that video images of them processed into data on position and orientation of target relative to camera. Subsystem useful in industrial assembly operation requiring automatic joining of parts initially oriented and moving randomly.

Shawaga, Lawrence M.↗

JOVE Pilot Research Study in Astronomy and Microgravity Sciences

The purpose of this project was to develop hardware and software facilities for evaluating the biomechanical interactions between human hands and space suit gloves. The first task was to measure finger joint angles inside space suit gloves. A preliminary survey identified three potential systems which could be used in the proposed study. In response to the current market situation, a glove for measuring the positions of the hand inside a space suit has been developed. A prototype of the glove has been constructed to demonstrate its sensing technologies. There are two types of sensors in the glove. The positions of the fingers are measured using bend sensors based on the CyberGlove design. This sensor consists of two strain gages mounted to a 0.003 inch thick mylar sheet. The sensor is encapsulated using 0.001 inch kapton film to give it sufficient rigidity. Along gage is used to average the strain generated in the sensor due to bending This average strain produces an output signal proportional to the angle of the bend. The force sensor consists of conductive ink sandwiched between two plastic sheets. An electrode is printed on one of the plastic sheets using silver ink. The resistance of the ink is sensitive to pressure.

Strauss, Alvin M.↗

Determination of an Infrared Reference Frame

The mission of the European Space Agency's Hipparcos satellite was to provide high precision astrometric and photometric data for over 100,000 stars and somewhat lower precision data on over a million additional stars. These observations were made in the optical band (340 - 850 nm) and resulted in median precisions of better than 1 milli-arcsec (mas) in position and parallax and I mas/yr in proper motion. The Hipparcos frame is inertial within an estimated uncertainty of +/- 0.25 mas/yr. The other important wavelength band for astrometry has been the radio band. A reference frame has been defined based on absolute Very Long Baseline Interferometry (VLBI) positions of several hundreds of radio sources. There have been a number of projects to refine the link between the optical and radio reference frames. In recent years there has been increasing interest in the astrometry of infrared sources. For example, stars with circumstellar shells can be observed in both the optical and radio (e.g. SiO maser emission). The infrared emission from such sources is dominated by thermal dust emission. The spatial distribution of radiation in the three bands is expected to be quite different. In 1982 we proposed a number of infrared-selected sources (S(sub 10 micron) greater than or approx. equal to 100 J(sub y)) for inclusion in the Hipparcos Input Catalog. Most of those sources were observed, and in Sutton (1997) we report the optical astrometric results (position, proper motion, and parallax) for 87 such sources. These sources were selected to have reasonable agreement between infrared and optical positions, and so may be used as primary standards for future infrared astrometry. They are well distributed across the sky, but exhibit some bias towards the galactic plane and the northern hemisphere. We have also obtained a set of 1480 secondary standards (unpublished) A comparison between optical positions and 86 GHz SiO maser positions for 10 sources indicates coincidence at the 0.15 arcsec level, consistent with current uncertainties in the SiO positions. Improved measurements of the SiO maser positions are needed. VLBI data show that SiO maser spots can be distributed in broken rings of radii 10 - 30 mas, presumably centered on the stellar position. However the SiO flux may be distributed asymmetrically, in which case the flux-weighted center of the SiO emission can be different from the stellar position. We have also published a related paper on phase fluctuations in millimeter interferometry (Sutton and Hueckstaedt 1996). Radiometric monitoring of emission from atmospheric water vapor may be a method for correcting for such fluctuations. This is relevant to positional determinations at centimeter and millimeter wavelengths. The integration of visible, infrared, and radio astrometry is one of our principal goals.

Sutton, Edmund C.↗

Lithospheric dynamics near plate boundaries

The progress report on research conducted between 15 Mar. - 14 Sep. 1992 is presented. The focus of the research during the first grant year has been on several problems broadly related to the nature and dynamics of time-dependent deformation and stress along major seismic zones, with an emphasis on western North America but with additional work on seismic zones in oceanic lithosphere as well. The principal findings of our research to date are described in the accompanying papers and abstract. Topics covered include: (1) Global Positioning System measurements of deformations associated with the 1987 Superstition Hills earthquake: evidence for conjugate faulting; (2) Global Positioning System measurements of strain accumulation across the Imperial Valley, California: 1986-1989; (3) present-day crustal deformation in the Salton Trough, southern California; (4) oceanic transform earthquakes with unusual mechanisms or locations: relation to fault geometry and state of stress in the lithosphere; and (5) crustal strain and the 1992 Mojave Desert earthquakes.

Solomon, Sean C.↗

Highly accurate positions of asteroids using astrometry

Astrometry is the precise measurement of positions in the sky of stars and other celestial bodies. In this paper, measurements of asteroids and outer planet natural satellites are discussed. We used the Astro Mechanics, Ritchey-Chrétien reflecting, 0.6m telescope at Table Mountain Observatory (TMO) located in Wrightwood, CA. Equipped with a 4k CCD camera (the ProLine4096x4096 imaging array with 9μm pixels), using 180 second exposures, we imaged the asteroids and outer satellites. We calculated two to three different positions of the asteroids, with different star fields, to best obtain positions. We obtained many different accurate positions of asteroids and the observing conditions, which were noted, inputted, then reduced with other data. We submit our data to the Minor Planet Center, and by the Solar System Dynamics (SSD) group at JPL. The data are also used for predicting occulting events. Through the execution of several Linux reduction programs and scripts, we reduce the data for the most accurate orbital positions.

Carr, Alexander G.↗

Wavefront Sensing With Switched Lenses for Defocus Diversity

In an alternative hardware design for an apparatus used in image-based wavefront sensing, defocus diversity is introduced by means of fixed lenses that are mounted in a filter wheel (see figure) so that they can be alternately switched into a position in front of the focal plane of an electronic camera recording the image formed by the optical system under test. [The terms image-based, wavefront sensing, and defocus diversity are defined in the first of the three immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] Each lens in the filter wheel is designed so that the optical effect of placing it at the assigned position is equivalent to the optical effect of translating the camera a specified defocus distance along the optical axis. Heretofore, defocus diversity has been obtained by translating the imaging camera along the optical axis to various defocus positions. Because data must be taken at multiple, accurately measured defocus positions, it is necessary to mount the camera on a precise translation stage that must be calibrated for each defocus position and/or to use an optical encoder for measurement and feedback control of the defocus positions. Additional latency is introduced into the wavefront sensing process as the camera is translated to the various defocus positions. Moreover, if the optical system under test has a large focal length, the required defocus values are large, making it necessary to use a correspondingly bulky translation stage. By eliminating the need for translation of the camera, the alternative design simplifies and accelerates the wavefront-sensing process. This design is cost-effective in that the filterwheel/lens mechanism can be built from commercial catalog components. After initial calibration of the defocus value of each lens, a selected defocus value is introduced by simply rotating the filter wheel to place the corresponding lens in front of the camera. The rotation of the wheel can be automated by use of a motor drive, and further calibration is not necessary. Because a camera-translation stage is no longer needed, the size of the overall apparatus can be correspondingly reduced.

Dean, Bruce H.↗

Plate measurement techniques and reduction methods used by the West German satellite observers, and resulting consequences for the observation

The West German tracking stations are equipped with ballistic cameras. Plate measurement and plate reduction must therefore follow photogrammetric methods. Approximately 100 star positions and 200 satellite positions are measured on each plate. The mathematical model for spatial rotation of the bundle of rays is extended by including terms for distortion and internal orientation of the camera as well as by providing terms for refraction which are computed for the measured coordinates of the star positions on the plate. From the measuring accuracy of the plate coordinates it follows that the timing accuracy for the exposures has to be about one millisecond, in order to obtain a homogeneous system.

Deker, H.↗

Supersonic and subsonic measurements of mesospheric ionization.

An Arcas rocket-parachute system was used at night to compare supersonic and subsonic ionization measurements below 75 km. A hemispherical nose-tip probe was used on ascent and a parachute-borne blunt probe on descent to measure polar conductivities, which were due entirely to positive and negative ions. The velocity of the supersonic probe was Mach 2.5 at 50 km and 1.75 at 70 km; the blunt probe was subsonic below 71 km. Between 65 and 75 km the ratio of negative to positive conductivities (and thus of mobilities) determined by the blunt probe was about 1.2, and it approached 1 below this altitude range. The ratio obtained by the nose-tip probe varied from 1.5 at 75 km to .6 at 65 km, thus indicating a rapid variation of the effects of the shock wave on the sampled ions. The absolute values of positive conductivity measured subsonically and supersonically were essentially identical from 60 to 75 km, indicating that the sampled ions were unchanged by the shock. However, below 60 km the shock apparently 'broke up' the positive ions, as indicated by higher measured conductivities.

Hale, L. C.↗

Positive and Negative Ion CIMS Measurements, SGP, May-June 2024

The negative ion measurements were taken using two LTOF-CIMS with two different nitrate inlets. The data labeled Aerodyne_Inlet used an Aerodyne nitrate inlet. Data labeled PCC used a custom transverse inlet. The positive ion measurements were taken using one LTOF-CIMS with hydronium as an ionization reagent using a custom transverse inlet with an inlet voltage difference of 700 V. See https://doi.org/10.1021/acs.jpca.2c01672 for more information. Peaks were autofit using tofware. Positive ion data is published in the form of peak signal/reagent signal. Data files of peak signal/reagent signal for the two mass spectrometers for the negative ion measurements are separate. Concentrations of H2SO4 are combined into one file. When measurements were overlapping, measurements from the Aerodyne nitrate inlet were used.

54 ENVIRONMENTAL SCIENCES↗

Mutants of Arabidopsis thaliana with altered phototropism

Thirty five strains of Arabidopsis thaliana (L.) Heynh. have been identified with altered phototropic responses to 450-nm light. Four of these mutants have been more thoroughly characterized. Strain JK224 shows normal gravitropism and "second positive" phototropism. However, while the amplitude for "first positive" phototropism is the same as that in the wild-type, the threshold and fluence for the maximum response in "first positive" phototropism are shifted to higher fluence by a factor of 20-30. This mutant may represent an alteration in the photoreceptor pigment for phototropism. Strain JK218 exhibits no curvature to light at any fluence from 1 micromole m-2 to 2700 micromoles m-2, but shows normal gravitropism. Strain JK345 shows no "first positive" phototropism, and reduced gravitropism and "second positive" phototropism. Strain JK229 shows no measurable "first positive" phototropism, but normal gravitropism and "second positive" phototropism. Based on these data, it is suggested that: 1. gravitropism and phototropism contain at least one common element; 2. "first positive" and "second positive" phototropism contain at least one common element; and 3. "first positive" phototropism can be substantially altered without any apparent alteration of "second positive" phototropism.

NASA Discipline Plant Biology↗

Resolving the Issues with Flywheel Position Sensors

For the past few years, the Advanced Electrical Systems Branch here at NASA Glenn has been pursuing research in the area of flywheels. The purpose of these pursuits has been t o explore the potential for flywheels to replace current battery-powered systems in space. So far it has been learned that flywheels offer large momentum storage capacity, comparatively small volume, high durability, and near- complete discharge capabilities, all of which are advancements over the existing nickel hydrogen and nickel cadmium batteries. Another significant advantage of flywheels is the potential they offer for combining the function of attitude control with energy storage. During the summer of 2004, I worked with Dr. Barbara Kenny in the Advanced Electrical Systems Branch, supporting the work she is doing by analyzing and testing some new components for the new Generation-2 flywheel. To monitor the speed and angular position of the flywheel rotor, a once-around (OAR) signal along with a sensorless algorithm is used. The OAR signal is used for the magnetic bearings that keep the flywheel suspended for frictionless operation. The sensorless algorithm is used for the flywheel motor/generator control. The OAR is generated from position sensors that monitor a circular plate. The plate has a cut down the middle such that one half of the circle is on a slightly lower level than the other. Every half-turn, or 180, the sensors detect the "cut" on the plate, and trigger the OAR, telling the computer that the rotor has made half a revolution. This, however, doesn't provide needed detailed information about the angular position of the rotor, since it only provides a signal alert every half- revolution. This is enough information for the magnetic bearing control but is insufficient for the motor/generator control. A new resolver was designed such that it would give continuous angle information rather than the 180 degree information of the OAR. The new resolver has two separate observable pieces: a flat middle section to monitor vertical motion, and an angled section around the circumference, which, when observed from above, produces a sine-wave displacement through the entire 360" revolution. My first job when I arrived this summer was to calibrate the sensors that would be mounted on the inside of the flywheel casing to monitor the position (angular and vertical) of the shaft. After calibration, I used the sensors to evaluate voltage outputs created by position differences between two pairs of sensors on the angled portion of the resolver for eight different angular positions, moving the resolver vertically and laterally through its entire potential range of motion. The results of these tests will be used to determine the rotor angular (and axial) position from the sensor readings once the new flywheel unit is assembled. The sensorless algorighm mentioned above consists of two operations: the signal injection method and the back electro-motive force (EMF). The signal injection is meant to work at low speeds, while the back EMF algorithm is meant to work at higher speeds. Both work together to determine the correct estimate of rotor position and speed based on the measured motor/generator current. It was determined that we wanted to know exactly how accurate our estimation methods were, and so a resolver (a commercially available mechanical sensor mounted to the motor/generator shaft to measure rotor position and speed) and a "Resolver to Digital" (R2D) circuit board was purchased to make the comparison to the existing estimation. My work related to the R2D board has included the following: creating two connector cables (one to power the circuit and one to get readable output off the board), writing Simulink code to process the board's output, and building a dSpace panel to control and monitor the circuit. The next step in the process will be to perform tests to compare the estimated rotor position and speed from the sensorless algorithm to the actual rotor and speed from the resolver signal.

Fehrmann, Elizabeth A.↗

Permanent GPS Geodetic Array in Southern California

The southern California Permanent GPS Geodetic Array (PGGA) was established in the spring of 1990 to evaluate continuous Global Positioning System (GPS) measurements as a new too] for monitoring crustal deformation. Southern California is an ideal location because of the relatively high rate of tectonic deformation, the high probability of intense seismicity, the long history of conventional and space geodetic measurements, and the availability of a well developed infrastructure to support continuous operations. Within several months of the start of regular operations, the PGGA recorded far-field coseismic displacements induced by the June 28, 1992 (M(sub w)=7.3), Landers earthquake, the largest magnitude earthquake in California in the past 40 years and the first one to be recorded by a continuous GPS array. Only nineteen months later, on 17 January 1994, the PGGA recorded coseismic displacements for the strongest earthquake to strike the Los Angeles basin in two decades, the (M(sub e)=6.7) Northridge earthquake. At the time of the Landers earthquake, only seven continuous GPS sites were operating in southern California; by the beginning of 1994, three more sites had been added to the array. However, only a pair of sites were situated in the Los Angeles basin. The destruction caused by the Northridge earthquake spurred a fourfold increase in the number of continuous GPS sites in southern California within 2 years of this event. The PGGA is now the regional component of the Southern California Integrated GPS Network (SCIGN), a major ongoing densification of continuous GPS sites, with a concentration in the Los Angeles metropolitan region. Continuous GPS provides temporally dense measurements of surface displacements induced by crustal deformation processes including interseismic, coseismic, postseismic, and aseismic deformation and the potential for detecting anomalous events such as preseismic deformation and interseismic strain variations. Although strain meters yield much higher short-term resolution to a period of about 1 year, a single continuous GPS site is significantly less expensive than a single strain meter and probably has better long-term stability beyond a 1-year period. Compared to less frequent field measurements, continuous GPS provides the means to better characterize the errors in GPS position measurements and thereby obtain more realistic estimates of derived parameters such as site velocities.

Green, Cecil H.↗

Completing the forward kinematic calibration of open loop manipulators when single point position sensors are used

Single-point sensors can measure the position of one point fixed to a manipulator's end effector. When single-point sensors have been used for calibration, it has not been possible to calibrate the orientation of the tool. Furthermore, it can be difficult to calibrate the sensor system. Results in the literature seldom provide a complete kinematic calibration of the manipulator. Presented here is a technique that enables single-point sensors to gather sufficient information to complete kinematic calibration. In addition, the method can reduce the burden of calibrating the sensor system.

Everett, Louis J.↗

Deriving a unique reference frame for GPS measurements

Two strategies for deriving a unique reference frame for GPS (Global Positioning System) measurements are discussed. The first strategy utilizes the precise relative positions which have been predetermined by VLBI (very long baseline interferometry) to fix the frame orientation and the absolute scaling, while the offset from the geocenter is determined from GPS measurements. Three different cases are presented under this strategy. The second strategy establishes a reference frame by holding only the longitudinal of one of the tracking sites fixed. The absolute scaling is determined by the adopted gravitational constant (GM) of the earth; and the latitude is inferred from the time signature of the earth's rotation in the GPS measurements. The coordinate system thus defined will be a geocentric earth fixed coordinate system. A covariance analysis shows that geometric positioning to an accuracy of a few centimeters can be achieved with just one day of precise GPS pseudorange and carrier phase data.

Malla, Rajendra P.↗

Direct plasma measurements in the Io torus and inner magnetosphere of Jupiter

The details of positive ion measurements made in the inner magnetosphere are discussed. Attention is also given to an analysis of these measurements to obtain plasma composition, flow speeds, and temperatures and to the assumptions made in the analysis. These results for the positive ions are then combined with the direct measurements of plasma electrons between 5.7 and 9 Jupiter radii and with a theoretical distribution of plasma along dipolar magnetic field lines to build a two-dimensional model of the plasma torus.

Bagenal, F.↗