Search NASA⌕ Search

SEARCH · Search NASA

Results for “pumping test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Southwest Wind Power R&D Test Site Development at the National Wind Technology Center (CRADA CRD-12-00472 Final Report)

Southwest Windpower, Inc. (SWWP) has been designing and distributing small wind turbines for more than 22 years and is the recognized global leader in the design, manufacturing and distribution of small wind systems (400-3000 watts). The company has been a pioneer in the development of wind technology and has built and shipped more than 170,000 wind turbines to over 120 countries worldwide. Headquartered in Flagstaff AZ, SWWP has sales representatives in over 88 countries. Applications for SWWP systems include residential homes, commercial properties, micro grids, remote cabins, telecom transmitters, offshore platforms, water pumping and sailboats. In addition, U.S. Department of Defense uses SWWP’s products in Forward Operating Bases (FOB’s), USGS uses them for remote monitoring of glacier movements and the CIA uses them to provide power seismic monitoring. Today, SWWP plans development of new technologies to address distributed energy market needs and become even more aggressive in international markets. This strategy includes extensive Research, Development, Demonstration & Deployment (RDD&D) activities to improve existing production line into more simple, reliable, and cost-effective wind turbine systems. Important part of such activities is the field testing of the new systems, which should provide: (i) validation of the reliable operation of hardware and software; (ii) validation of numerical models of the system and its components; (iii) field comparison of various control and optimization strategies; (iv) customized reliability testing; (v) customized monitoring and analysis testing; and (vi) IEC certification testing (vii) filed demonstration of system performance and reliability. Such field testing facility should encompass multiple towers and appropriate data acquisition systems. SWWP is exploring to move part of the engineering department to Colorado, and execute its RDD&D strategies in this new location. Partnership with NREL will provide great insights into SWWP’s RDD&D processes and more efficient commercialization by utilizing NWTC as the field testing site, and working close with NREL personnel. NWTC is ideally suited to strain the design. NREL is very experienced with customized and IEC testing. During this project, Southwest Windpower aims to improve the value proposition of distributed renewable energy, and make it a competitive choice in the energy markets. As of today, more then 170,000 small wind turbines, manufactured in the U.S., are installed in more then 180 countries. With the improved value proposition, Southwest Windpower wants to create and address new market needs, substantially increase its sales domestically and internationally, which should have positive impact on the creation of American jobs, competitiveness of U.S. economy, export or U.S. products, and the use of renewable energy.

17 WIND ENERGY↗

A Systematic Interpretation of Subsurface Proppant Concentration from Drilling Mud Returns: Case Study from Hydraulic Fracturing Test Site (HFTS-2) in Delaware Basin

The aim of this study is generation and validation of a proppant log using analysis of drilling mud returns for child wells. Proppant log provides qualitative as well as quantitative insights into spatial distribution of proppant sand particles from prior stimulation of parent wells. While the basic methodology was developed and formalized during analysis of material collected from through fracture cores at Hydraulic Fracturing Test Site in Midland Basin (HFTS – 1), the test wells at HFTS – 2 in the neighboring Delaware Basin allowed the opportunity to validate the workflow on actual mud return samples from subsurface. As a child well is being drilled, periodic mud return samples are collected at the rig site and preserved for analysis. The workflow involves systematic cleaning of the samples including various steps such as washing, drying and segregation of samples into relevant size fractions of interest (< Mesh 20) based on specifications of pumped sand during stimulation of the parent well. Clean samples are imaged using high resolution transparency scanning. Scan images are then systematically analyzed for particles of interest using computer vision techniques. Sample counts are further validated using elemental analysis of smaller sub-samples at various depths of interest. This step is necessary to isolate proppant versus other naturally occurring minerals such as sulphates and carbonates which show similar optical properties. We successfully correlated proppant distribution against the existing parent well and validated propped versus relatively un-propped zones for a child well at the test site. The advantage of testing the proppant log concept at the HFTS – 2 site is the plethora of additional diagnostic data that is available to validate our primary observations. We can correlate spatial proppant distribution against variability in stimulation response based on independent observations such as image logs, microseismic attributes as well as DAS response, all of which tend to corroborate one another. One of our significant successes was being able to describe varying degrees of impact of the parent well along the lateral length of a stimulated child well. Our workflow represents a systematic and one-of-a-kind interpretation of spatial proppant distribution while drilling child wells. This provides unique opportunities to better understand the current state of the Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/2-21URTC/D021S031R003/2477415/urtec-2021-5189-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5189 2 reservoir being targeted including zones which are likely more drained relative to others and how the planned completion of the child well can be improved. Lastly, this log can be useful is validating optimal well spacing in relatively new fields under development.

58 GEOSCIENCES↗

Development of Methods for In-line Monitoring of Yield Stress During the Transfer of Radioactive Waste - 20435

Radioactive waste slurries at the Savannah River Site (SRS) and Hanford often behave as non-Newtonian fluids with a yield stress. The yield stress increases the size of equipment needed to transport or mix these slurries and can increase the risk of process upsets. This property is often measured by collection of samples and transportation to a laboratory, which can increase the risk of personnel exposure and even change the rheology. In addition, slurry rheology has been observed to change with time. Real-time in-line monitoring (RTIM) of rheological properties of slurries can have substantial benefits to critical processes which are currently in operation or will be part of future plans in Department of Energy (DOE) complex processes. The need for an appropriate RTIM technology that can potentially minimize or eliminate numerous sampling operations was recently identified. This research at Florida International University focuses on addressing the need for a reliable RTIM technology at US Department of Energy sites. The objective of this work is to investigate and develop appropriate and reliable technologies that can perform accurate and easy measurements of yield stress with minimal changes to the flow conditions at US Department of Energy sites. Use of ultrasound in longitudinal and shear modes was considered as a method for monitoring of yield stress variations with no disturbance to the flow. Measurement of shear wave velocity (in shear mode) and monitoring of sound velocity variations with start of flow from rest (longitudinal mode) are the underlying principles. Measurement of pressure loss and liquid rise (due to static differential pressure) during flow of slurries were two other methods that were considered and investigated. In addition, analysis of stability depth of a penetrometer in slurry medium (penetrometer method) revealed a potential suitability. This paper presents efforts associated with investigation of different methods mentioned earlier for kaolin-water mixtures at different concentrations. Theoretical analysis showed that all methods under investigation were capable of monitoring yield stress in a desirable range of 0 to 70 pascal. A bench scale test setup was constructed for investigation of pressure loss and liquid rise methods. Simulants at different concentrations were created for initial testing campaigns. For ultrasonic testing, effects of yield stress on sound propagation speed in longitudinal and shear modes were investigated for simulants placed inside PVC pipes. Parameters such as simulant concentration and pipe diameter were varied to find optimal values. It was found that spacing (or medium thickness) of 1/8 inch or less was necessary to observe echoes with sufficient strength. In addition, a significant effect of yield stress on sound propagation velocity was observed. For the liquid rise method, kaolin-water simulant at 1.17 specific gravity was pumped through a 1/4 inch pipe and liquid height was measured in a vertical riser branching off a three-way connection. Static gauge pressure was varied within [0.3 to 1.1] psi range by increase of pumping pressure and flow. Results showed consistent yield stress data within 10% deviation from values reported by a rheometer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MEASUR - Manufacturing Energy Assessment Software for Utility Reduction

MEASUR your energy savings with the free DOE MEASUR software The Department of Energy (DOE), with Oak Ridge National Laboratory (ORNL), released version 1.0 of their energy efficiency software tool MEASUR (Manufacturing Energy Assessment Software for Utility Reduction). MEASUR has been available for several years as a beta version, being tested by industry experts and real users, and will continue to be updated and improved in the coming years. It is an integrated suite of tools to aid manufacturers in improving the efficiency of energy systems and equipment within a plant, including motors, pumps, fans, process heating, steam, and compressed air. Additionally, there are modules for wastewater energy analysis and to help perform energy treasure hunts. Several calculators are also included, allowing users to independently perform smaller calculations and analyses (such as estimating pump head, performing a fan traverse analysis, estimating waste heat recovery potential, and cataloging compressed air leaks). The MEASUR modules are based on previous DOE software tools that have been used by industry since the early 2000s (such as MotorMaster, AirMaster+, PSAT, PHAST, and FSAT). The original tools only ran on Windows operating systems, and by Windows 10, most of them were inoperable. DOE started their energy efficiency software tool revitalization effort in 2016, first with PSAT (for pumps), then began to integrate the other tools and expand their functionality and utility. The new MEASUR suite provides an extensively more user-friendly, modern, and versatile set of tools. All the assessment modules and most of the calculators have several visual components and graphs and detailed help text for every user input. To help reach international users, the tool utilizes Google translate and users can easily change unit systems, even converting existing user inputs if desired. The assessment files can be organized within the internal file system and easily shared to other users, regardless of their operating system. The entire suite is free, open-source, and can be downloaded on Windows, Mac, or Linux operating systems.

Accawi, Gina [Oak Ridge National Lab. (ORNL), Oak ↗

Review of Mercury Sequestration in Cementitious Waste Forms

Decontaminated salt solution from Tank 50 at the Savannah River Site (SRS) is known to contain dissolved mercury species which are present as hydroxides and oxides. These species are reported in analytical measurements as the organic cation [CH 3 Hg] + and the inorganic cation Hg 2+ . The salt solution is mixed with cementitious reagents, blast-furnace slag (BFS) and thermally beneficiated Class F fly ash in the Saltstone Processing Facility and pumped into engineered Saltstone Disposal Units, (SDUs), to produce a solidified waste form. The solidified waste form, saltstone, encapsulates and chemically stabilizes the mercury and other contaminants, sequestering them from release into the environment. With the discovery of methylmercury in the salt solution, testing was performed to determine the extent to which saltstone prepared with methylmercury (MeHg) retains mercury in the Toxicity Characteristic Leaching Procedure (TCLP). Results from this testing indicated that the amount of mercury extracted remained below the regulatory limit, and that the saltstone formulation with a greater proportion of BFS performed slightly better at retaining Hg in the solid.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Geomechanical and Hydrogeological Evaluation of a Shallow Hydraulic Fracture at the Devine Fracture Pilot Site, Medina County, Texas

UT-Austin’s Devine Fracture Pilot Site, 50 miles southwest of San Antonio, Texas, has been targeted for a comprehensive, multidisciplinary development of fracture diagnostic techniques that are cross-validated by ground-truth data acquisition near a recently created, 175-ft-deep, horizontal hydraulic fracture (Ahmadian et al. 2018 Demonstration of proof of concept of electromagnetic geophysical methods for high resolution illumination of induced fracture networks. In Proceedings of the SPE Hydraulic Fracturing Technology Conference and Exhibition, The Woodlands, Texas, USA, 23–25 January 2018. SPE-189858-MS.). To evaluate the fracture diagnostic methods at this site, we conducted injection tests with a predefined volumetric flow-rate profile, resembling a diagnostic fracture injection test on September 2020. Subsequently, we developed hydrogeological and geomechanical models based on flow-rate and bottomhole-pressure measurements. History-matching efforts using a simplified layer-cake hydrogeological model resulted in the field-scale formation permeability of 9.87 × 10 –15 m 2 (10 mD) and Darcy-scale fracture permeability. The analysis of the bottomhole pressure and injection-rate history showed that (1) the newly created horizontal fracture was closed adjacent to the injection well pre-injection and (2) the initial pump-pressure increase at a nominal volumetric injection rate led to near-well fracture reopening, fluid conductivity increase, and abrupt injection-rate increase. To overcome hydrogeological-model limitations of predicting fracture reopening throughout injection, we extended the modeling to a finite-element, poroelastic analysis of horizontal-fracture growth using a cohesive-zone model. Using this fracture-reopening model, we improved the history match of the transient-pressure response during the experiment by adjusting the hydromechanical properties. Furthermore, post-injection pressure transient analyses helped reduce uncertainty in the overburden-stress gradient, and the initial hydraulic-fracturing simulation verified the plausibility of achieving the surveyed propped fracture area.

02 PETROLEUM↗

Superconducting-like response in driven systems near the Mott transition

Here we point out that fractionalized bosonic charge excitations can explain the recently discovered photoinduced superconducting-like response in $\kappa$-(ET) 2 Cu [N(CN) 2 ] Br, an organic metal close to the Mott transition. The pump laser exerts a periodic drive on the fractionalized field, creating a nonequilibrium condensate, which gives a Drude peak much narrower than the equilibrium scattering rate, hence a superconducting-like response. Our proposal illuminates alternative possibilities of detecting fractionalization and can be readily tested in spin liquid candidates and in cold atom systems.

36 MATERIALS SCIENCE↗

Maritime Fuel Cell Generator Project: 2018 – 2023

This report summarizes activity in the Maritime Fuel Cell (MarFC) Generator Project from 2018 – 2023. FY 2018 saw the implementation of upgrades and repairs, making the unit more reliable and operator friendly. In FY2019 the team engaged the Scripps Institution of Oceanography (SIO) to use the MarFC to provide zero-emission shore power to the research vessel R/V Robert Gordon Sproul while in port at the Nimitz Marine Facility in San Diego, CA. In FY2020, the MarFC unit was shipped to San Diego, CA. A fueling contract with IGX was established to support MarFC operations at SIO, with renewable hydrogen provided by the California State University Los Angeles (CSULA) hydrogen station. The project team (Sandia, Cummins/Hydrogenics) provided training to SIO staff on the technical details of the MarFC, the safe use of hydrogen in general and the MarFC in particular. The first fueling of the unit at the SIO pier was successfully completed by IGX. The first powering of a vessel with fuel-cell shore power was conducted with the R/V Robert Gordon Sproul. While the mechanical systems (lights, AC, ventilation, hydraulics, pumps and cranes) were powered without incident, problems arose when powering the computer systems. Inspections carried out in FY2021 revealed the MarFC needed routine maintenance. Maintenance was performed and the unit was upgraded. The MarFC was turned on after the year pause, and initial test data on power levels and stability were collected. FY2022 was a year spent repairing, upgrading and testing the MarFC unit. Spikes in power and voltage were observed above 60 kW that could potentially extend below 60 kW with time. Such spikes could cause problems with the Sproul electrical systems. These age-related problems, the extended time for the Sproul spent in dry dock for scheduled upgrades, and the associated need to reschedule the vessel’s high-priority science missions made it no longer possible to deploy the unit at SIO. After due consideration, the decision was made by DOE, MARAD and the project team to cease the deployment, remove the MarFC from SIO, and not pursue further deployment activities. On December 2, 2022, the MarFC unit was removed from the Scripps Nimitz Marine Facility and shipped to Fridley, Michigan. The Cummins/Hydrogenics plan for the unit is to assess the condition of the MarFC subcomponents, and then use it as a training/learning system for technical employees new to hydrogen fuel-cell technology. After summarizing project activity from 2018 – 2023, this report provides a review of lessons learned. This report provides next steps in contemplating a follow-on project that would further advance the use of fuel-cell-based shore power in a marine setting. A comparison is made of the project results to the original objectives. This report ends with an accounting of presentations stemming from the project, and a list of references.

08 HYDROGEN↗

Evaluating the economic impacts of using enzymatic membranes to optimize bicarbonate production and delivery to open raceway ponds

Gas sparging is the most commonly used method for delivering CO2 to algal cultures in Open Raceway Ponds (ORPs). While this method is well-tested and effective, these systems experience large amounts of outgassing to the surrounding atmosphere and often achieve carbon utilization efficiencies (CUE) lower than 30%. With such large losses, system are overdesigned to provide CO2 gas in extreme excess, resulting in increased capital and operational expenses. This research is focused on the development, testing, and implementation of a hydrogel membrane seeded with the enzyme carbonic anhydrase and designed to convert gaseous CO2 into aqueous bicarbonate and deliver this inorganic carbon (iC) directly to the algae pond. Despite increased capital expenses for the module, bicarbonate storage tank, and added pumps and infrastructure, preliminary results suggest that the membrane module has the potential to reduce the minimum biomass selling price by 35% by significantly reducing the operational expenditure for CO2.

09 BIOMASS FUELS↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Western Sector In-Situ Chemical Oxidation Project: Additional Injection Pilot Testing Supplemental Results (U)

Trichloroethylene (TCE) and tetrachloroethylene (PCE) are persistent at elevated concentrations in the Western Sector of the M-Area Hazardous Waste Management Facility (HWMF) groundwater plume. Migration of these chlorinated ethenes as Dense Non-Aqueous Phase Liquids (DNAPLs) occurred from the M-Area Settling Basin along geologic strata resulting in a high concentration groundwater plume in Western Sector. Pump-and-treat has been active for over 30 years at the M-Area HWMF to hydraulically contain the primary sources of the plume in addition to other remediation strategies throughout the contaminated zone, like soil vapor extraction, dynamic underground stripping, groundwater recirculation wells, and bioremediation. In-situ chemical oxidation (ISCO) has been identified as a viable treatment method for removal of these volatile organic compounds (VOCs) due to the complex lithology and high concentrations in this part of the aquifer. In addition to ISCO, a new recovery well (i.e., RWM018) was also installed in Western Sector to contain the high concentration VOC plume. The ISCO projects have utilized the gradient induced by RWM018 to help plan the injection and monitoring locations. The combination of ISCO and the additional pump and treat in Western Sector with the installation of RWM018 will help to control the plume and maximize remediation efforts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Analytical Functions for 200 West Pump-and-Treat SCADA Sensor Data

Historical operations at the U.S. Department of Energy’s Hanford Site included disposal of waste fluids to the subsurface in the 200 West Area on the Hanford Central Plateau. Subsequent infiltration of fluids has resulted in groundwater contamination with carbon tetrachloride, nitrate, uranium, technetium-99, and other contaminants. A pump-and-treat (P&T) system, with an extraction/injection well network and an aboveground treatment plant, was implemented as part of interim and final remedies in the 200 West area. The HYPATIA single-page web application (part of the SOCRATES suite) is being developed to provide access to and analysis of chemistry and treatment facility sensor data for this 200 West P&T system. For the web application, analytical algorithms were developed to perform summing, differencing, smoothing, outlier detection, change-point detection, mass flow rate, and injectivity calculations on the data. Candidate algorithms were identified and tested, with the best-performing algorithms then assembled for implementation in HYPATIA. Because HYPATIA is hosted on the Amazon Web Services (AWS) cloud computing platform, algorithms were implemented in a back-end AWS Lambda function that can be called by the HYPATIA front end. The Lambda function applies the requested data processing to specified data via functions written in R, Python, and JavaScript. Development, testing, and review of the data analysis algorithms was completed under an NQA-1 quality program. This new HYPATIA functionality will provide information to support site decisions regarding P&T system performance and optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2022)

This report documents the operations, testing, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) during FY2022. The METL facility had a very successful fourth year of operations and went through some new experiences such as taking the facility from its frozen state in October 2021 and thawing the facility and also recovering from an oxide plug in one of the cold trap lines. After the facility was fully thawed, the METL staff maintained the facility in a continuous molten state – either flowing sodium or a static flow condition. METL facility continued supporting the Gear Test Assembly (GTA) testing and hosted its first 28” test vessel experiment, called the Thermal Hydraulic Experimental Test Article (THETA) which was inserted into Test Vessel 4. Work to accommodate two additional experiments, a gripper test article (GrTA) and a flow sensor test article (F-STAr) continued as they are expected to make their debut in FY2023. In addition, the steam piping for the B308 scrubber unit was replaced with stainless steel piping and controls and new parts for the scrubber were purchased – such as a new pump, new storage tank, and new blower and motor. These components will ultimately replace the existing scrubber components when those 1970’s era require replacement.

42 ENGINEERING↗

Data-Driven Reduced-Order Modeling of Convective Heat Transfer in Porous Media

This work presents a data-driven Reduced-Order Model (ROM) for parametric convective heat transfer problems in porous media. The intrusive Proper Orthogonal Decomposition aided Reduced-Basis (POD-RB) technique is employed to reduce the porous medium formulation of the incompressible Reynolds-Averaged Navier–Stokes (RANS) equations coupled with heat transfer. Instead of resolving the exact flow configuration with high fidelity, the porous medium formulation solves a homogenized flow in which the fluid-structure interactions are captured via volumetric flow resistances with nonlinear, semi-empirical friction correlations. A supremizer approach is implemented for the stabilization of the reduced fluid dynamics equations. The reduced nonlinear flow resistances are treated using the Discrete Empirical Interpolation Method (DEIM), while the turbulent eddy viscosity and diffusivity are approximated by adopting a Radial Basis Function (RBF) interpolation-based approach. The proposed method is tested using a 2D numerical model of the Molten Salt Fast Reactor (MSFR), which involves the simulation of both clean and porous medium regions in the same domain. For the steady-state example, five model parameters are considered to be uncertain: the magnitude of the pumping force, the external coolant temperature, the heat transfer coefficient, the thermal expansion coefficient, and the Prandtl number. For transient scenarios, on the other hand, the coastdown-time of the pump is the only uncertain parameter. The results indicate that the POD-RB-ROMs are suitable for the reduction of similar problems. The relative L2 errors are below 3.34% for every field of interest for all cases analyzed, while the speedup factors vary between 54 (transient) and 40,000 (steady-state).

German, Péter (ORCID:0000000307285283)↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗