Search NASA⌕ Search

SEARCH · Search NASA

Results for “recent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Metrology of Time-Domain Soft X-Ray Attosecond Pulses and Reevaluation of Pulse Durations of Three Recent Experiments

Attosecond pulses in the soft x-ray (SXR) to water-window energy region offer the tools for creating and studying target-specific localized inner-shell electrons or holes in materials, enabling monitoring or controlling charge and energy flows in a dynamic system on attosecond timescales. Recently, a number of laboratories have reported generation of continuum harmonics in the hundred-electron-volt to kilovolt region with few-cycle long-wavelength mid-infrared lasers. These harmonics have the bandwidth to support pulses with durations of a few to a few-ten attoseconds. But harmonics generated in a gas medium have attochirps that cannot be fully compensated by materials over a broad spectral range; thus, realistically what are the typical shortest attosecond pulses that one can generate? To answer this question, it is essential that the temporal attosecond pulses be accurately characterized. By reanalyzing the soft x-ray attosecond metrology reported in three recent experiments using a newly developed broadband phase retrieval algorithm, we demonstrate here that the generated attosecond pulses in the first two papers have durations of about 60 as, longer than what they have reported. Similarly, the duration from the third experiment is retrieved to be about half of the 322-as upper limit cited in that work. We also introduce the autocorrelation (AC) of the streaking spectrogram. By comparing the ACs from the experiments and from the retrieved SXR pulses, the accuracy of the retrieved results can be directly visualized. Our retrieval method is fast and accurate, and it shall provide a powerful tool for the metrology of the emerging few-ten-attosecond pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Is the thick brane model consistent with recent observations?

There exist many observational evidences implying the expansion of our Universe is undergoing a late-time acceleration; the mechanism of this acceleration is yet unknown. In the so-called thick brane model this phenomena is attributed to the thickness of the brane along the extra dimension. In this study we mainly rely on the consistency of this model with most recent observational data related to the background evolution. The new Supernova Type Ia (SNIa) Gold sample and Supernova Legacy Survey (SNLS) data, the position of the acoustic peak at the last scattering surface from the Wilkinson Microwave Anisotropy Probe (WMAP) observations and the baryon acoustic oscillation peak found in the Sloan Digital Sky Survey (SDSS) are used to constrain the free parameter of the thick codimension 1 brane model. To infer its consistency with the age of our Universe, we compare the age of old cosmological objects with what computed using the best-fit values for the model parameters. When the Universe is matter dominated, w=0, at 68% level of confidence, the combination of the Gold sample SNIa, cosmic microwave background (CMB) shift parameter and SDSS databases provide {omega}{sub m}=0.31{sub -0.02}{sup +0.02}, {omega}{sub C}=0.05{sub -0.01}{sup +0.01}, w{sub r}=-1.40{sub -0.20}{sup +0.20}, hence a spatially open universe with {omega}{sub k}=0.21{sub -0.08}{sup +0.08}. The same combination with the SNLS supernova observation gives {omega}{sub m}=0.28{sub -0.02}{sup +0.03}, {omega}{sub C}=0.037{sub -0.004}{sup +0.003}, w{sub r}=-2.05{sub -0.15}{sup +0.15} consequently provides a spatially open universe {omega}{sub k}=0.11{sub -0.07}{sup +0.10}. These results obviously seem to be in contradiction with the most recent WMAP results indicating a flat universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interpreting the recent results on direct searches for dark matter particles in terms of relic neutralinos

The most recent results from direct searches for dark matter particles in the Galactic halo are examined in terms of an effective minimal supersymmetric extension of the standard model at the electroweak scale without unification of gaugino masses. We show that the annual-modulation effect at 8.2{sigma} C.L. recently presented by the DAMA Collaboration, as the result of a combined analysis of the DAMA/NaI and the DAMA/LIBRA experiments for a total exposure of 0.82 ton yr, fits remarkably well with what is expected for relic neutralinos for a wide variety of weakly interacting massive particle distribution functions. Bounds derivable from other measurements of direct searches for dark matter particles are analyzed. We stress the role played by the uncertainties affecting the neutralino-quark couplings arising from the involved hadronic quantities. We also examine how present data on cosmic antiprotons can help in constraining the neutralino configurations selected by the DAMA effect, in connection with the values of the astrophysical parameters. Perspectives for measurements of antideuterons, possibly produced in the Galactic halo by self-annihilation of neutralinos belonging to the DAMA configurations, are examined. Finally, we discuss how findings at the LHC would impact on these issues.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lessons from recent measurements of D{sup 0}-D{sup 0} mixing

An impressive progress in measurements of the D{sup 0}-D{sup 0} mixing parameters has been made in recent years. We explore the implications of these measurements to models of new physics, especially in view of recent upper bounds on the amount of CP violation. We update the constraints on nonrenormalizable four-quark operators. We show that the experiments are close to probing minimally flavor violating models with large tan{beta}. The data challenge models with a scale of order TeV where the flavor violation in the down sector is suppressed by alignment and, in particular, certain classes of supersymmetric models and of warped extra dimension models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparing the predictions of two mixed neutralino dark matter models with the recent CDMS II candidate events

We consider two optimally mixed neutralino dark matter models, based on nonuniversal gaugino masses, which were recently proposed by us to achieve WMAP compatible relic density over a large part of the minimal supersymmetric standard model parameter space. We compare the resulting predictions for the spin-independent dark matter scattering cross section with the recent CDMS II data, assuming the possibility of the two reported candidate events being signal events. For one model the predicted cross section agrees with the putative signal over a small part of the parameter space, while for the other the agreement holds over the entire WMAP compatible parameter space of the model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implications of the recent high statistics determination of the pion electromagnetic form factor in the timelike region

The recently evaluated two-pion contribution to the muon g-2 and the phase of the pion electromagnetic form factor in the elastic region, known from {pi}{pi} scattering by Fermi-Watson theorem, are exploited by analytic techniques for finding correlations between the coefficients of the Taylor expansion at t=0 and the values of the form factor at several points in the spacelike region. We do not use specific parametrizations, and the results are fully independent of the unknown phase in the inelastic region. Using for instance, from recent determinations, <r{sub {pi}}{sup 2}>=(0.435{+-}0.005) fm{sup 2} and F(-1.6 GeV{sup 2})=0.243{sub -0.014}{sup +0.022}, we obtain the allowed ranges 3.75 GeV{sup -4} < or approx. c < or approx. 3.98 GeV{sup -4} and 9.91 GeV{sup -6} < or approx. d < or approx. 10.46 GeV{sup -6} for the curvature and the next Taylor coefficient, with a strong correlation between them. We also predict a large region in the complex plane where the form factor cannot have zeros.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pole structure of the Λ ( 1405 ) in a recent QCD simulation

The Λ(1405) baryon is difficult to detect in experiment, absent in many quark model calculations, and supposedly manifested through a two-pole structure. Its uncommon properties made it subject to numerous experimental and theoretical studies in recent years. Lattice-QCD eigenvalues for different quark masses were recently reported by the Adelaide group. We compare these eigenvalues to predictions of a model based on Unitary Chiral Perturbation Theory. The UχPT calculation predicts the quark mass dependence remarkably well. It also explains the overlap pattern with different meson-baryon components, mainly πΣ and K¯N, at different quark masses. As a result, more accurate lattice QCD data are required to draw definite conclusions on the nature of the Λ(1405).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Positrons and 511 keV Radiation as Tracers of Recent Binary Neutron Star Mergers

Neutron-rich material ejected from neutron star–neutron star (NS-NS) and neutron star–black-hole (NS-BH) binary mergers is heated by nuclear processes to temperatures of a few hundred keV, resulting in a population of electron-positron pairs. Some of the positrons escape from the outer layers of the ejecta. We show that the population of low-energy positrons produced by NS-NS and NS-BH mergers in the Milky Way can account for the observed 511-keV line from the Galactic center (GC). Moreover, we suggest how positrons and the associated 511-keV emission can be used as tracers of recent mergers. Recent discovery of 511-keV emission from the ultrafaint dwarf galaxy Reticulum II, consistent with a rare NS-NS merger event, provides a smoking-gun signature of our proposal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Psilocybin: crystal structure solutions enable phase analysis of prior art and recently patented examples

Psilocybin {systematic name: 3-[2-(dimethylamino)ethyl]-1 H -indol-4-yl dihydrogen phosphate} is a zwitterionic tryptamine natural product found in numerous species of fungi known for their psychoactive properties. Following its structural elucidation and chemical synthesis in 1959, purified synthetic psilocybin has been evaluated in clinical trials and has shown promise in the treatment of various mental health disorders. In a recent process-scale crystallization investigation, three crystalline forms of psilocybin were repeatedly observed: Hydrate A, Polymorph A, and Polymorph B. The crystal structure for Hydrate A was solved previously by single-crystal X-ray diffraction. This article presents new crystal structure solutions for the two anhydrates, Polymorphs A and B, based on Rietveld refinement using laboratory and synchrotron X-ray diffraction data, and density functional theory (DFT) calculations. Utilizing the three solved structures, an investigation was conducted via Rietveld method (RM) based quantitative phase analysis (QPA) to estimate the contribution of the three different forms in powder X-ray diffraction (PXRD) patterns provided by different sources of bulk psilocybin produced between 1963 and 2021. Over the last 57 years, each of these samples quantitatively reflect one or more of the hydrate and anhydrate polymorphs. In addition to quantitatively evaluating the composition of each sample, this article evaluates correlations between the crystal forms present, corresponding process methods, sample age, and storage conditions. Furthermore, revision is recommended on characterizations in recently granted patents that include descriptions of crystalline psilocybin inappropriately reported as a single-phase `isostructural variant.' Rietveld refinement demonstrated that the claimed material was composed of approximately 81% Polymorph A and 19% Polymorph B, both of which have been identified in historical samples. In this article, we show conclusively that all published data can be explained in terms of three well-defined forms of psilocybin and that no additional forms are needed to explain the diffraction patterns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recent Advancements in Reconfigurable mmWave Devices Based on Phase-Change and Metal Insulator Transition Materials

Chalcogenide Phase Change Materials (PCM) and metal insulator transition (MIT) materials are a group of materials that are capable of switching between low resistance and high resistance states. These emerging materials have been widely used in optical storage media and memory devices. Over the past recent years, there have been interests in exploiting the PCM and MIT materials, especially germanium antimony telluride (GST) alloys and vanadium dioxide (VO 2 ), for radio frequency (RF) applications. The PCM and MIT-based RF devices are expected to bridge the gap between semiconductor switches and microelectromechanical system (MEMS) switches as they combine the low insertion loss performance of MEMS technology and the small size and reliability performance of semiconductor technology. This article presents an overview of the PCM and MIT materials for RF circuits and discusses the recent advancements in reconfigurable millimeter-wave (mmWave) devices based on PCM and MIT materials in depth.

36 MATERIALS SCIENCE↗

Metamorphic III–V Solar Cells: Recent Progress and Potential

Inverted metamorphic multijunction solar cells have been demonstrated to be a pathway to achieve the highest photovoltaic (PV) conversion efficiencies. Attaining high-quality lattice-mismatched (metamorphic) semiconductor devices is challenging. However, recent improvements to compositionally graded buffer epitaxy and junction structures have led to the achievement of high-quality metamorphic solar cells exhibiting internal luminescence efficiencies over 90%. For this high material quality, photon recycling is significant, and therefore, the optical environment of the solar cell becomes important. In this paper, we first present recent progress and performance results for 1- and 0.7-eV GaInAs solar cells grown on GaAs substrates. Then, an electrooptical model is used to assess the potential performance improvements in current metamorphic solar cells under different realizable design scenarios. The results show that the quality of 1-eV subcells is such that further improving its electronic quality does not produce significant Voc increases in the four-junction inverted metamorphic subcells, unless a back reflector is used to enhance photon recycling, which would significantly complicate the structure. Conversely, improving the electronic quality of the 0.7-eV subcell would lead to significant Voc boosts, driving the progress of four-junction inverted metamorphic solar cells.

14 SOLAR ENERGY↗

Radiometric Standards and Best Practices: Recent Progress

International standards and best practices for solar resource assessments provide assurance for traceable measurements associated with a low uncertainty. This benefits the solar energy industry by reducing the investment risks through heightened confidence in the solar resource information. NREL, in collaboration with international organizations, such as subcommittees G03 of ASTM (Radiometry) and TC180/SC1 of ISO (Climate measurement and data), recently revised some standards that are widely used by the solar industry. These include radiometric standards that assist in (i) maintaining calibration traceability; (ii) uncertainty analysis; (iii) measurement quality assurance, and (iv) establishing reference spectral irradiance distributions. The latter are widely used by the solar community to evaluate the actual absorptance, reflectance, and transmittance of solar energy materials, or the performance of solar energy devices and systems, relative to standard conditions. This paper provides a summary of the recent changes brought to these standards as a way to better support the solar energy industry.

industries↗

High-Performance Bi-2212 Round Wires Made With Recent Powders

Multifilamentary Bi 2 Sr 2 CaCu 2 O x (Bi-2212) wire made by the powder-in-tube technique is the only high-temperature superconductor made in the round shape preferred by magnet builders. The critical current density (J C ) of Bi-2212 round wire was improved significantly by the development of overpressure heat treatment in the past few years. Bi-2212 wire is commercially available in multiple architectures and kilometer-long pieces and is a very promising conductor for very high-field NMR and accelerator magnets. Here, we studied the effects of precursor powder and heat treatment conditions on the superconducting properties and microstructure of recent Bi-2212 wires. Short samples of recent wire with optimized overpressure processing showed J C (4.2 K, 15 T) = 6640 A/mm 2 and J C (4.2 K, 30 T) = 4670 A/mm 2 , which correspond to engineering critical current densities J E (4.2 K, 15 T) = 1320 A/mm 2 and J E (4.2 K, 30 T) = 930 A/mm 2 .

36 MATERIALS SCIENCE↗

Nuclear Waste Vitrification in the U.S.: Recent Developments and Future Options

Nuclear power plays a key role in maintaining current world wide energy growth while minimizing the greenhouse gas emissions. A disposition path for used nuclear fuel (UNF) must be found for this technology to achieve its promise. One likely option is the recycling of UNF and immobilization of the high-level waste (HLW) by vitrification. Vitrification is the technology of choice for immobilizing HLW from defense and commercial fuel reprocessing around the world. Recent advances in both recycling technology and vitrification show great promise in closing the nuclear fuel cycle in an efficient and economical fashion. This article summarizes the recent trends developments and future options in waste vitrification for both defense waste cleanup and closing the nuclear fuel cycle in the U.S.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of recent studies on nanoscale electrical junctions and contacts: Quantum tunneling, current crowding, and interface engineering

The study of charge carrier transport at nanoscale electrical contacts is crucial for the development of next-generation electronics. In this study, we review recent modeling efforts on quantum tunneling, current crowding, and contact resistance across electrical interfaces with nanometer scale dimensions. A generalized self-consistent model for quantum tunneling induced electron transport in metal–insulator–metal (MIM) junctions is summarized. Rectification of a dissimilar MIM junction is reviewed. A modified two-dimensional (2D) transmission line model is used to investigate the effects of spatially varying specific contact resistivity along the contact length. The model is applied to various types of electrical contacts, including ohmic contacts, MIM junction based tunneling contacts, and 2D-material-based Schottky contacts. Roughness engineering is recently proposed to offer a possible paradigm for reducing the contact resistance of 2D-material-based electrical contacts. Contact interface engineering, which can mitigate current crowding near electrical contacts by spatially designing the interface layer thickness or properties, without requiring an additional material or component, is briefly reviewed. Tunneling engineering is suggested to eliminate severe current crowding in highly conductive ohmic contacts by introducing a thin tunneling layer or gap between the contact members. Furthermore, unsolved problems and challenges are also discussed.

2D materials↗

WE-E-18C-01: Multi-Energy CT: Current Status and Recent Innovations

Conventional computed tomography (CT) uses a single polychromatic x-ray spectrum and energy integrating detectors, and produces images whose contrast depends on the effective attenuation coefficient of the broad spectrum beam. This can introduce errors from beam hardening and does not produce the optimal contrast-to-noise ratio. In addition, multiple materials can have the same effective attenuation coefficient, causing different materials to be indistinguishable in conventional CT images. If transmission measurements at two or more energies are obtained, even with polychromatic beams, more specific information about the object can be obtained. If the object does not contain materials with k-edges in the spectrum, the x-ray attenuation can be well-approximated by a linear combination of two processes (photoelectric absorption and Compton scattering) or, equivalently, two basis materials. For such cases, two spectral measurements suffice, although additional measurements can provide higher precision. If K-edge materials are present, additional spectral measurements can allow these materials to be isolated. Current commercial implementations use varied approaches, including two sources operating a different kVp, one source whose kVp is rapidly switched in a single scan, and a dual layer detector that can provide spectral information in every reading. Processing of the spectral information can be performed in the raw data domain or in the image domain. The process of calculating the amount of the two basis functions implicitly corrects for beam hardening and therefore can lead to improvements in quantitative accuracy. Information can be extracted to provide material specific information beyond that of conventional CT. This additional information has been shown to be important in several clinical applications, and can also lead to more efficient clinical protocols. Recent innovations in x-ray sources, detectors, and systems have made multi-energy CT much more practical and improved its performance. In addition, this is a very active area of research and further improvements are expected through further technological improvements. Learning Objectives: Basic principles of multi-energy CT Current implementations of mutli-energy CT Data and image analysis methods in multi-energy CT Current clinical applications of dual energy CT5. recent innovations and anticipated advances in multi-energy CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Study of heavy-ion collisions in the PHENIX experiment: Survey of the most recent results

The first experimental results obtained at the Relativistic Heavy Ion Collider (RHIC) over the period between 2000 and 2005 are indicative of the production of dense and hot partonic matter in relativistic heavy-ion collisions. Investigations performed in recent years make it possible to extend the list of measured signatures and to study their dependence on the greater number of variables. The most recent results obtained in the PHENIX experiment by studying proton-proton and nucleus-nucleus collisions are surveyed. Particular attention is given to studying the properties of the initial state, dynamical evolution of the product medium, and its response to the propagation of high-energy partons through it. The aforementioned effects are studied via measuring the properties of identified hadrons and leptons over a broad region of transverse momenta at various rapidities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗