Search NASA⌕ Search

SEARCH · Search NASA

Results for “rejection sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A COMPREHENSIVE ANALYSIS OF FERMI GAMMA-RAY BURST DATA. III. ENERGY-DEPENDENT T {sub 90} DISTRIBUTIONS OF GBM GRBs AND INSTRUMENTAL SELECTION EFFECT ON DURATION CLASSIFICATION

The durations (T {sub 90}) of 315 gamma-ray bursts (GRBs) detected with Fermi/GBM (8-1000 keV) up to 2011 September are calculated using the Bayesian Block method. We compare the T {sub 90} distributions between this sample and those derived from previous/current GRB missions. We show that the T {sub 90} distribution of this GRB sample is bimodal, with a statistical significance level comparable to those derived from the BeppoSAX/GRBM sample and the Swift/BAT sample, but lower than that derived from the CGRO/BATSE sample. The short-to-long GRB number ratio is also much lower than that derived from the BATSE sample, i.e., 1:6.5 versus 1:3. We measure T {sub 90} in several bands, i.e., 8-15, 15-25, 25-50, 50-100, 100-350, and 350-1000 keV, to investigate the energy-dependence effect of the bimodal T {sub 90} distribution. It is found that the bimodal feature is well observed in the 50-100 and 100-350 keV bands, but is only marginally acceptable in the 25-50 keV and 350-1000 keV bands. The hypothesis of bimodality is confidently rejected in the 8-15 and 15-25 keV bands. The T {sub 90} distributions in these bands are roughly consistent with those observed by missions with similar energy bands. The parameter T {sub 90} as a function of energy follows T-bar {sub 90}{proportional_to}E{sup -0.20{+-}0.02} for long GRBs. Considering the erratic X-ray and optical flares, the duration of a burst would be even longer for most GRBs. Our results, together with the observed extended emission of some short GRBs, indicate that the central engine activity timescale would be much longer than T {sub 90} for both long and short GRBs and the observed bimodal T {sub 90} distribution may be due to an instrumental selection effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and structural analysis of Mars Rover RTG

The Mars Rover and Sample Return mission's radioisotope thermoelectric generator (RTG) is presently subjected to a structural and mass analysis in view of a reference mission scenario, an illustrative Rover design and Martian activities agenda, and RTG power system requirements and environmental constraints. The modular heat-source stack in the Rover RTG can be held together by axial load springs. The RTGs should be mounted on the Rover with a vertical orientation, in order to avoid the buildup of windborne Martian sand on its heat-rejection surfaces.

Schock, Alfred↗

{sup 6}LiF:ZnS(Ag) Neutrons Scintillator Detector Configuration for Optimal Readout

A Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is under development at the NIST Center for Neutron Research (NCNR). The CANDOR neutron sensor will rely on scintillator material for detecting the neutrons scattered by the sample under test. It consists of {sup 6}LiF:ZnS(Ag) scintillator material into which wavelength shifting (WLS) fibers have been embedded. Solid state photo-sensors (silicon photomultipliers) coupled to the WLS fibers are used to detect the light produced by the neutron capture event ({sup 6}Li (n,α) {sup 3}H reaction) and ionization of the ZnS(Ag). This detector configuration has the potential to accomplish the CANDOR performance requirements for efficiency of 90% for 5 A (3.35 meV) neutrons with high gamma rejection (10{sup 7}) along with compact design, affordable cost and materials availability. However this novel design includes challenges for precise neutron detection. The recognizing of the neutron signature versus the noise event produce by gamma event cannot be easy overcome by pulse height discrimination obstacle as can be achieved with {sup 3}He gas tube. Furthermore the selection of silicon photomultipliers (SiPM) as the light sensor maintains the obstacle of dark noise that does not exist when a photomultiplier tube is coupled to the scintillator. A proper selection of SiPM should focus on increasing the output signal and reducing the dark noise in order to optimize the detection sensitivity and to provide a clean signal pulse shape discrimination. The main parameters for evaluation are: - Quantum Efficiency (QE) - matching the SiPM peak QE with the peak transmission wavelength emission of the WLS. - Recovery time - a short recovery time is preferred to minimize the pulse width beyond the intrinsic decay time of the scintillator crystal (improves the gamma rejection based output pulse shape (time)). - Diode dimensions -The dark noise is proportional to the diode active area while the signal is provided by the WLS fibers; therefore the diode area should ideally be only minimally larger than fiber bundle area. - Low dark noise - it is desirable to minimize the dark noise during the pulse integration period so as to minimize the background for pulse shape discrimination. - Photon Detection Efficiency - it is desirable to increase the SiPM PDE in order to enhance light collection. This will increase the likelihood of detecting neutron events with lower light production and will present a cleaner raw signal for pulse shape discrimination. We will present the SiPM optimization process and studies of dark noise and gamma and neutron sensitivity as a function of bias voltage and operating temperature that have enabled us to optimize the detector sensitivity and gamma rejection. The gamma rejection performance goal requires to overcome the challenge of discriminating between the light signature accepted by neutron event to the one received by the noise. In addition there is a huge variation between the number of light photons that reaching the WLS fibers for different neutron events caused by the heavy ions energy losses prior to ionizing the ZnS(Ag) and the high light attenuation of the scintillation mixture. This variation in the light signal along with the long decay time of the ZnS(Ag) (tens of microseconds) can cause double counting of the same neutron event in the case of high light output signature or preventing the detection of low sequential light output signature neutron event. We will presents the algorithm developed for {sup 6}LiF:ZnS(Ag) sensor readout and the results achieved by an off-line analysis by Matlab software code that successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Difference Imaging of Lensed Quasar Candidates inthe SDSS Supernova Survey Region

Difference imaging provides a new way to discover gravitationally lensed quasars because few non-lensed sources will show spatially extended, time variable flux. We test the method on lens candidates in the Sloan Digital Sky Survey (SDSS) Supernova Survey region from the SDSS Quasar Lens Search (SQLS) and their surrounding fields. Starting from 20768 sources, including 49 SDSS quasars and 36 candidate lenses/lensed images, we find that 21 sources including 15 SDSS QSOs and 7 candidate lenses/lensed images are non-periodic variable sources. We can measure the spatial structure of the variable flux for 18 of these sources and identify only one as a non-point source. This source does not display the compelling spatial structure of the variable flux of known lensed quasars, so we reject it as a lens candidate. None of the lens candidates from the SQLS survive our cuts. Given our effective survey area of order 0.71 square degrees, this indicates a false positive rate of order one per square degree for the method. The fraction of quasars not found to be variable and the false positive rate should both fall if we analyze the full, later data releases for the SDSS fields. While application of the method to the SDSS is limited by the resolution, depth, and sampling of the survey, several future surveys such as Pan-STARRS, LSST, and SNAP will avoid these limitations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmogenic 137 Xe Analysis of Alternatives for nEXO

Neutrinoless double-beta decay is a hypothetical nuclear decay in which two matter particles are produced without corresponding antimatter particles. Observation of neutrinoless double-beta decay would shed light on a potential explanation of matter-antimatter observed in the universe and also indicate the Majorana nature of neutrinos, meaning that the neutrino can act as its own antiparticle. The nEXO experiment is a proposed 5-ton liquid xenon time projection chamber detector with a projected 1.35 × 10 28 yr half-life sensitivity to neutrinoless double-beta decay in 136 Xe [J. Phys. G 49, 015104 (2022)]. While nEXO has a baseline location of SNOLAB, there are several other underground facilities in the world capable of hosting the experiment. The primary change at each site will be cosmogenic 137 Xe backgrounds, caused by varied cosmogenic muon activity at each site. This study finds that while there is a negligible increase in nEXO’s half-life sensitivity at 90% C.L. from improving the cosmogenic 137 Xe veto rejection procedure for SNOLAB, much higher daily muon rates at three other sites will have an adversely negative effect on nEXO’s sensitivity and would likely require further modifications to nEXO’s baseline design to reach nEXO’s scientific goals. Monte Carlo simulations of muons inducing 137 Xe backgrounds were conducted at four underground sites, SNOLAB, SURF, LNGS, and WIPP, each with roughly a factor of 10 times higher daily muon activity than the previous site. There were two primary inputs to these simulations. The first was sample data of cosmogenic muon flight through nEXO’s outer detector, a 12.8m tall and 12.3m wide cylindrical water tank lined with photomultiplier tubes to detect Cerenkov radiation, and all of the secondary interactions produced in the detector. The second input was a parametrization of 137 Xe* production tagging when 137 Xe de-excites and release prompt gammas, as well as accidental tagging caused by neutron capture on 63 Cu, 65 Cu, 19 F, and 1 H throughout the detector. Together, the number of backgrounds relative to the previous 2021 Sensitivity Paper [J. Phys. G 49, 015104 (2022)] was found at each of these four sites across three energy windows, from 400, 1400, and 2600 keV all up to 4600 keV, just above the end point of the prompt gamma spectrum for 137 Xe*. Using level curves for the sensitivity as 137 Xe backgrounds scale relative to baseline calculations, the half-life sensitivity at 90% C.L. for each of trial was found. Even with reduced 137 Xe backgrounds, the results for SNOLAB yielded neglible improvements in nEXO’s predicted sensitivity. On the contrary, the increased backgrounds for the three other considered sites yielded sensitivity estimates below nEXO’s previous projections. This study demonstrates that the shielding from cosmogenic muons at SNOLAB makes it highly preferred even amongst other world leading underground laboratories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Opinion: Making the Most of Colour Rendition Research

After decades of debate, new methods for characterizing color rendition have been formalized, providing an improved system of tools to aid technology developers and lighting specifiers. Solid-state lighting, previously burdened by legacy measures based on outdated science, is positioned to take advantage of these new tools to provide tailored, efficient lighting that better meets the needs of specific architectural lighting applications. This transition requires new guidance, however, presenting an opportunity for researchers. There are several key methodological considerations specific to experiments investigating color rendition that will help build a base of guidance that can be widely applied. The importance of these ideas mostly stems from new knowledge gained in the last five years, but their origins date back much further. 1.The spectral power distribution must be adequately varied to stress the measure(s) of color rendition being evaluated. Often, this means varying the gamut shape—the pattern of shift across different hues—to probe weaknesses of hue-averaged characterizations, avoiding misleading conclusions resulting from limited variation in the stimuli. 2.Evaluating the role of chromaticity on color quality evaluations requires careful accommodation of chromatic adaptation to prevent a centering bias. Asking for delayed responses may be insufficient if chromaticity changes are apparent to participants, just as side-by-side viewing of different chromaticities may not produce results that can be reliably applied in the field. It is also critical that color rendition and chromaticity conditions are varied independently. 3.The stimulus being viewed is the interaction of light and objects’ spectral reflectances. This interaction should be quantified in order to assess how derived guidelines will apply measures using standardized color sample sets. Although light source characterizations are typically used to model responses, the objects and their presentation may strongly influence evaluations. 4.Context is important. Many factors—some investigated, others hypothesized—can influence subjective evaluations of color quality, including illuminance level, type of scene, object familiarity, color composition, viewing duration, and viewer traits. Although their influence on research results is unavoidable, the effects of these contextual factors must be carefully considered in developing guidance. Appropriate experimental design can often mitigate negative consequences arising from these considerations. At a minimum, it is crucial to understand how each of these considerations can influence experimental outcomes, as well as the interpretation and application of the results in practice. Consulting other experts prior to conducting an experiment can help ensure appropriate, up-to-date research methods will be used, so that the results will be novel and useful—and not rejected during peer review. There is an interesting feedback loop: technology development provides new research tools, which allow for refined research methods and new results that lead to more technology development. It is time to make a concerted, collective effort to improve color rendition research so that the full potential of solid-state lighting and new characterization methods can be realized, ensuring that high-efficiency, high-utility, high-appeal lighting systems become standard.

Royer, Michael P.↗

Dipole anisotropy of galaxy distribution: Does the CMB rest frame exist in the local universe?

The peculiar motion of the Earth causes a dipole anisotropy modulation in the distant galaxy distribution due to the aberration effect. However, the amplitude and angular direction of the effect is not necessarily the same as those of the cosmic microwave background (CMB) dipole anisotropy due to the growth of cosmic structures. In other words exploring the aberration effect may give us a clue to the horizon-scale physics perhaps related to the cosmic acceleration. In this paper we develop a method to explore the dipole angular modulation from the pixelized galaxy data on the sky, properly taking into account the covariances due to the shot noise and the intrinsic galaxy clustering contamination as well as the partial sky coverage. We applied the method to the galaxy catalogs constructed from the Sloan Digital Sky Survey Data Release 6 data. After constructing the four galaxy catalogs that are different in the ranges of magnitudes and photometric redshifts to study possible systematics, we found that the most robust sample against systematics indicates no dipole anisotropy in the galaxy distribution. This finding is consistent with the expectation from the concordance {Lambda}-dominated cold dark matter model. Finally, we argue that an almost full-sky galaxy survey such as Large Synoptic Survey Telescope may allow for a significant detection of the aberration effect of the CMB dipole having the precision of constraining the angular direction to {approx}20 deg in radius. Assuming a hypothetical Large Synoptic Survey Telescope galaxy survey, we find that this method can confirm or reject the result implied from a stacked analysis of the kinetic Sunyaev-Zel'dovich effect of X-ray luminous clusters in Kashlinsky et al. (2008, 2009) if the implied cosmic bulk flow is not extended out to the horizon.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Tolerant Electronics and Digital Processing for the Phase-1 Read-out Upgrade of the ATLAS Liquid Argon Calorimeters

The ATLAS Liquid Argon calorimeters are designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |η|<3.2, and for hadronic calorimetry in the region from |η|=1.5 to |η|=4.9. Although the nominal LHC experimental programme is still in progress, an upgrade of the read-out electronics is being launched to cope with luminosities of up to 3x10{sup 34} cm{sup -2}s{sup -1}, which are beyond the original design by a factor of 3. An improved spatial granularity of the trigger primitives is therefore proposed in order to improve the identification performance for trigger signatures, like electrons, photons, tau leptons, jets, total and missing energy, at high background rejection rates. For the upgrade Phase-1 in 2018, new LAr Trigger Digitizer Boards (LTDB) are being designed to receive higher granularity signals, digitize them on detector and send them via fast optical links to a new LAr digital processing system (LDPS). The LDPS applies a digital filtering and identifies significant energy depositions in each trigger channel. The refined trigger primitives are then transmitted to the first level trigger system to extract improved trigger signatures. The read-out of the trigger signals will process 34000 so-called Super Cells at every LHC bunch-crossing at a frequency of 40 MHz. The new LTDB on-detector electronics is designed to be radiation tolerant in order to be operated for the remaining live-time of the ATLAS detector up to a total luminosity of 3000 fb{sup -1}. For the analog-to-digital conversion (12-bit ADC at 40 MSPS), the data serialization and the fast optical link (5.44 Gb/s) custom components have been developed. They have been qualified for the expected radiation environment of a total ionization dose of 1.3 kGy and a hadron fluence of 6 x 10{sup 13} h/cm{sup 2} with energies above 20 MeV. For the digital components like the ADC, cross-sections for single event effects have been determined. This talk will present R and D results from tests of the radiation tolerant components, the fast data processing electronics and prototypes of the LTDB and LDPS boards. First experience from a Demonstrator setup will be reported, in which about 1/10 of the full Super Cell readout will be equipped with prototype versions of the LTDB and LDPS boards. The Demonstrator will be operated in parallel to the regular ATLAS trigger read-out during the upcoming LHC run. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Detection System for DUNE Low-Energy Physics Study and the Demonstration of a Timing Resolution of a Few Nanoseconds Using ProtoDUNE-SP PDS

Photon detection systems (PDS) are an integral part of liquid-argon neutrino detectors. Besides providing the timing information for an event, which is necessary for reconstructing the drift coordinates of ionizing particle tracks, photon detectors can be effectively used for other purposes, including triggering events, background rejection, and calorimetric energy estimation. PDS in particular for the DUNE Far Detector Module 2 is designed to achieve a more extended optical coverage (→4 ) with new-generation large-size PD modules based on the ARAPUCA technology. This will provide enhanced opportunities for the study of low-energy neutrino physics using PDS. The ARAPUCA technology was extensively tested within the ProtoDUNE-SP detector operated at the CERN neutrino platform. Here, we present a study of the timing resolution of ARAPUCA detectors using light emitted from a sample of energetic cosmic ray muons traveling parallel to the PDS. An intrinsic timing resolution in the order of 3 ns is observed for the ARAPUCA detectors. The excellent timing resolution ability of PDS can be exploited for further enhancing physics studies using the DUNE far detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple experiment processing furnace crystal growth facility (MEPF-CGF)

The Multiple Experiment Processing Furnace - Crystal Growth Facility (MEPF-CGF) will be an improved modular version of earlier generation directional solidification furnaces having the capability for processing larger samples, for on-orbit exchange of samples by a crew member, and for pre-mission reconfiguration to accommodate a variety of user requirements. The MEPF-CGF will provide the capability for crystal growth in the microgravity environment and will satisfy the processing requirements of the crystal growth community. The MEPF-CGF will be accommodated in the pressurized Spacelab Module (manned environment) on board the Space Shuttle Orbiter. The system will permit operation of the furnace with crew interaction and will utilize Spacelab/Shuttle resources such as experiment mounting provisions, electrical power, data, communication, heat rejection, and crew time.

Srinivas, R.↗

Adaptive Telemetry Multiplexer

Telemetry-data-acquisition unit adjusted remotely to produce changes in sampling rate, sampling channels, measurement scale, and output-bias level. Functional configuration adapted to changing conditions or new requirements by distant operator over telemetry link. Reconfiguration done in real time, without removing equipment from service. Bus-interface unit accepts reprogramming commands and translates them for low-rate adaptive multiplexer. Reprogrammable equipment reduces need for spare parts, since not necessary to stock variety of hardware with fixed characteristics. Adaptive multiplexer performs well in tests, amplitude errors less than 0.5 percent, distortion less than 0.25 percent, and crosstalk and common-mode rejection indiscernible.

Sinderson, R. L.↗

Label Free Detection of L-Glutamate Using Microfluidic Based Thermal Biosensor

A thermoelectric biosensor for the detection of L-glutamate concentration was developed. The thermoelectric sensor is integrated into a micro-calorimeter which measures the heat produced by biochemical reactions. The device contains a single flow channel that is 120 µm high and 10 mm wide with two fluid inlets and one fluid outlet. An antimony-bismuth (Sb-Bi) thermopile with high common mode rejection ratio is attached to the lower channel wall and measures the dynamic changes in the temperature when L-glutamate undergoes oxidative deamination in the presence of glutamate oxidase (GLOD). The thermopile has a Seebeck coefficient of ~7 µV·(m·K)-1 . The device geometry, together with hydrodynamic focusing, eliminates the need of extensive temperature control. Layer-by-layer assembly is used to immobilize GLOD on the surface of glass coverslips by alternate electrostatic adsorption of polyelectrolyte and GLOD. The impulse injection mode using a 6-port injection valve minimizes sample volume to 5 µL. The sensitivity of the sensor for glutamate is 17.9 nVs·mM-1 in the linear range of 0–54 mM with an R2 value of 0.9873. The lowest detection limit of the sensor for glutamate is 5.3 mM.

layer-by-layer self-assembly↗

THE COEVALITY OF YOUNG BINARY SYSTEMS

Multiple star systems are commonly assumed to form coevally; they thus provide the anchor for most calibrations of stellar evolutionary models. In this paper, we study the binary population of the Taurus-Auriga association, using the component positions in an HR diagram in order to quantify the frequency and degree of coevality in young binary systems. After identifying and rejecting the systems that are known to be affected by systematic errors (due to further multiplicity or obscuration by circumstellar material), we find that the relative binary ages, |DELTAlog tau|, have an overall dispersion sigma{sub |D}ELTA{sub logt}au{sub |}approx 0.40 dex. Random pairs of Taurus members are coeval only to within sigma{sub |D}ELTA{sub logt}au{sub |}approx 0.58 dex, indicating that Taurus binaries are indeed more coeval than the association as a whole. However, the distribution of |DELTAlog tau| suggests two populations, with approx2/3 of the sample appearing coeval to within the errors (sigma{sub |D}ELTA{sub logt}au{sub |}approx 0.16 dex) and the other approx1/3 distributed in an extended tail reaching |DELTAlog tau|approx 0.4-0.9 dex. To explain the finding of a multipeaked distribution, we suggest that the tail of the differential age distribution includes unrecognized hierarchical multiples, stars seen in scattered light, or stars with disk contamination; additional follow-up is required to rule out or correct for these explanations. The relative coevality of binary systems does not depend significantly on the system mass, mass ratio, or separation. Indeed, any pair of Taurus members wider than approx10' (approx0.7 pc) shows the full age spread of the association.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The effect of numbers of noise events on people's reactions to noise - An analysis of existing survey data

Even though there are surveys in which annoyance decreases as the number of events increases above about 150 a day, the available evidence is not considered strong enough to reject the conventional assumption that reactions are related to the logarithm of the number of events. The data do not make it possible to reject the conventional assumption that the effects of the number of events and the peak noise level are additive. It is found that even when equivalent questionnaire items and definitions of noise events could be used, differences between the surveys' estimates of the effect of the number of events remained large. Three explanations are suggested for inconsistent estimates. The first has to do with errors in specifying the values of noise parameters, the second with the effects of unmeasured acoustical and area characteristics that are correlated with noise level or number, and the third with large sampling errors deriving from community differences in response to noise. It is concluded that significant advances in the knowledge about the effects of the number of noise events can be made only if surveys include large numbers of study areas.

Fields, J. M.↗

Multi-physics melt pool modeling and process optimization for laser direct energy deposition of Nb-based refractory C103: Defect formation, geometric precision, and process mapping

Recent developments in additive manufacturing (AM) technology have reignited interest in the fabrication of the Nb-based refractory C103 alloy offering solutions to the challenges posed by traditional manufacturing methods. However, the limited numerical and experimental studies on laser direct energy deposition (DED) of C103 have hindered the understanding of the relationships between process parameters and build quality. This has made it challenging to consistently produce parts with the desired quality and microstructure suitable for critical applications. In this study, we focus on optimizing the laser DED process for C103 by employing a hybrid approach that combines experimental techniques and computational fluid dynamics (CFD). This approach facilitates the development of process maps for defect detection and geometric precision. To achieve this, multi-layer C103 samples were fabricated using laser DED under various process parameters, enabling the creation of a process map for defect detection. Additionally, a multi-physics, multiphase simulation framework was developed within a high-performance computing (HPC) environment to establish process maps for geometric precision. Using these process maps, printability windows were identified for achieving both the desired geometric accuracy and defect-free prints. It was observed that prints with a power-to-velocity (P/V) ratio close to unity resulted in defect-free outcomes. This study provides a foundation for reducing design lead time and rejected parts, ultimately optimizing the laser DED process for C103.

Defect formation and geometric precision↗

Shear horizontal surface acoustic wave microsensor for Class A viral and bacterial detection.

The rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms is critical to human health and safety. To achieve a high level of sensitivity for fluidic detection applications, we have developed a 330 MHz Love wave acoustic biosensor on 36{sup o} YX Lithium Tantalate (LTO). Each die has four delay-line detection channels, permitting simultaneous measurement of multiple analytes or for parallel detection of single analyte containing samples. Crucial to our biosensor was the development of a transducer that excites the shear horizontal (SH) mode, through optimization of the transducer, minimizing propagation losses and reducing undesirable modes. Detection was achieved by comparing the reference phase of an input signal to the phase shift from the biosensor using an integrated electronic multi-readout system connected to a laptop computer or PDA. The Love wave acoustic arrays were centered at 330 MHz, shifting to 325-328 MHz after application of the silicon dioxide waveguides. The insertion loss was -6 dB with an out-of-band rejection of 35 dB. The amplitude and phase ripple were 2.5 dB p-p and 2-3{sup o} p-p, respectively. Time-domain gating confirmed propagation of the SH mode while showing suppression of the triple transit. Antigen capture and mass detection experiments demonstrate a sensitivity of 7.19 {+-} 0.74{sup o} mm{sup 2}/ng with a detection limit of 6.7 {+-} 0.40 pg/mm{sup 2} for each channel.

60 APPLIED LIFE SCIENCES↗

Prompt Gamma Rays in {sup 77}Ge after Neutron Capture on {sup 76}Ge

The observation of neutrinoless double beta decay would be proof of the Majorana nature of the neutrino. Half-lives for these decays are very long (for {sup 76}Ge:>10{sup 25} y), so background reduction and rejection is the major task for double beta experiments. The GERDA (GERmanium Detector Array) experiment at the Gran Sasso Laboratory of the INFN (LNGS) searches for neutrinoless double beta decay of {sup 76}Ge. The isotope {sup 76}Ge is an ideal candidate because it can be used as source and detector at the same time. A large remaining contribution to the background arises from the prompt gamma cascade after neutron capture by {sup 76}Ge followed by {beta}{sup -}-decay of {sup 77}Ge. Since the prompt gamma decay scheme is poorly known, measurements with isotopically enriched Germanium samples were carried out at the PGAA facility at the research reactor FRM II (Munich). With the known prompt gamma spectrum it will be possible to improve the overall veto efficiency of the GERDA experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗