Search NASA⌕ Search

SEARCH · Search NASA

Results for “responsive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Response of thick, notched laminates subjected to tension-compression cyclic loads

The fatigue response of a (0/24/90/-45)s4 T300-5208 graphite-epoxy laminate with a drilled centerhole subjected to fully reversed tension-compression (R=-1, T-C) constant amplitude loading was investigated. Damage evaluation techniques such as stiffness monitoring, penetrant-enhanced X-ray radiography, C-scan, laminate deply and residual strength were used to establish the mechanisms of damage development as well as the relations between this damage and the stiffness, strength and life of the laminate. Damage initiated at the hole as matrix cracking parallel to the fibers in all plies. Matrix cracks had a significant effect on delamination initiation and growth. Delaminations initiated near the surface in the densely cracked region at the hole and grew along major matrix cracks. Compressive properties degraded more rapidly than tensile properties. At the stress levels used, residual tensile strength increased early in the fatigue life and remained approximately constant to near the end of life, when failure was precipitated by excessive laminate instability during the compressive portion of the loading.

Bakis, C. E.↗

Empirical Investigations of the Opportunity Limits of Automatic Residential Electric Load Shaping

Residential electric load shaping is often modeled as infrequent, utility-initiated, short-duration deferral of peak demand through direct load control. In contrast, modeled herein is the potential for frequent, transactive, intraday, consumer-configurable load shaping for storage-capable thermostatically controlled electric loads (TCLs), including refrigerators, freezers, and hot water heaters. Unique to this study are 28 months of 15-minute-interval observations of usage in 101 homes in the Pacific Northwest United States that specify exact start, duration, and usage patterns of approximately 25 submetered loads per home. The magnitudes of the load shift from voluntarily-participating TCL appliances are aggregated to form hourly upper and lower load-shaping limits for the coordination of electrical generation, transmission, distribution, storage, and demand. Empirical data are statistically analyzed to define metrics that help quantify load-shaping opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Proper Bonding Methods and Mechanical Characterization FPGA CQFPs

This presentation discusses fractured leads on field-programmable gate array (FPGA) during flight vibration. Actions taken to determine root cause and resolution of the failure include finite element analysis (FEA) and vibration testing and scanning electron microscopy (with X-ray microanalysis) and energy dispersive spectrometry (SEM/EDS) failure assessment. Bonding methods for surface mount parts is assessed, including critical analysis and assessment of random fatigue damage. Regarding ceramic quad flat pack (CQFP) lead fracture, after disassembling the attitude control electronics (ACE) configuration, photographs showed six leads cracked on FPGA RTSX72SU-1 CQ208B package located on the RWIC card. An identical package (FPGA RTSX32SU-1 CQ208B) mounted on the RWIC did not results in cracked pins due to vibration. FPGA lead failure theories include workmanship issues in the lead-forming, material defect in the leads of the FPGA packages, and the insecure mounting of the board in the card guides, among other theories. Studies were conducted using simple calculations to determine the response and fatigue life of the package. Shorter packages exhibited more response when loaded by out-of-plane displacement of PCB while taller packages exhibit more response when loaded by in-plane acceleration of PCB. Additionally, under-fill did not contribute to reducing stress in leads due to out-of-plane PCB loading or from component twisting, as much as corner bonding. The combination of corner bond and under-fill is best to address mechanical and thermal S/C environment. Test results of bonded parts showed reduced (dampened) amplitude and slightly shifted peaks at the un-bonded natural frequency and an additional response at the bonded frequency. Stress due to PCBB out-of-plane loading was decreased on in the corners when only a corner bond was used. Future work may address CQFP fatigue assessment, including the investigation of discrepancy in predicted fatigue damage, as well as comparing fatigue life and fatigue damage cycle ration computed using FEA and Miner's rule to results from a fatigue assessment software program.

Davis, Milton C.↗

The effects of an autopilot on airplane responses to turbulence with emphasis on tail loads

An analytical study has been made to assess the loads developed on the horizontal tail of an autopilot-controlled rigid airplane flying in one-dimensional atmospheric turbulence. The root-mean-square values of rigid-airframe responses and tail-load responses were calculated at five flight conditions, and the behavior of these responses was observed in two autopilot modes: pitch-attitude-hold mode and altitude-control mode. It was found that pitch attitude and altitude can be controlled by the simple autopilot with acceptable or no increases in tail loads.

Perry, B., III↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A method may include exciting a device coupled to a load, and capturing a response of the device. The method may further include adjusting the response based on an estimated load response of the device, and estimating an impedance of the device based on the adjusted response.

Christophersen, Jon P.↗

Demand Response Pilot Events Conducted August 25, 2011 and August 9, 2012: Summary Report (Rev.1)

Energy management in a commercial facility can be segregated into two areas: energy efficiency and demand response (DR). Energy efficiency focuses on steady-state load minimization. Demand response reduces load for event driven periods during the peak load. Demand response driven changes in electricity use are designed to be short-term in nature, centered on critical hours during the day when demand is high or, utilized when the electricity supplier's reserve margins are low. Due to the recent Federal Energy Regulatory Commission (FERC) Order 745, Demand Response Compensation in Organized Wholesale Energy Markets, the potential annual compensation to Sandia National Laboratories (SNL) from performing DR ranges from $\$$200K to $\$$1,800K. While the current energy supply contract does not offer any compensation for participating in DR, there is benefit in understanding the issues and potential value in performing a DR event. This Report will be helpful in upcoming energy supply contract negotiations to quantify the energy savings and power reduction potential from DR at SNL. On August 25, 2011 and August 9, 2012 the Facilities Management and Operations Center (FMOC) performed the first and second DR pilot events at SNL/NM. This report describes the details and results of these DR events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxygen Uptake Responses to Submaximal Exercise Loads Do Not Change During Long-Duration Space Flight

In previous publications we have reported that the heart rate (HR) responses to graded submaximal exercise tests are elevated during long-duration International Space Station (ISS) flights. Furthermore, the elevation in HR appears greater earlier, rather than later, during the missions. A potential confounder in the interpretation of HR results from graded exercise tests on ISS is that the cycle ergometer used (CEVIS) is vibration-isolated from the station structure. This feature causes the CEVIS assembly to sway slightly during its use and debriefing comments by some crewmembers indicate that there is a "learning curve" associated with CEVIS use. Therefore, one could not exclude the possibility that the elevated HRs experienced in the early stages of ISS missions were related to a lowered metabolic efficiency of CEVIS exercise that would raise the submaximal oxygen uptake (VO2) associated with graded exercise testing work rates.

Moore, Alan D., Jr.↗

A Model for Simulating the Response of Aluminum Honeycomb Structure to Transverse Loading

A 1-dimensional material model was developed for simulating the transverse (thickness-direction) loading and unloading response of aluminum honeycomb structure. The model was implemented as a user-defined material subroutine (UMAT) in the commercial finite element analysis code, ABAQUS(Registered TradeMark)/Standard. The UMAT has been applied to analyses for simulating quasi-static indentation tests on aluminum honeycomb-based sandwich plates. Comparison of analysis results with data from these experiments shows overall good agreement. Specifically, analyses of quasi-static indentation tests yielded accurate global specimen responses. Predicted residual indentation was also in reasonable agreement with measured values. Overall, this simple model does not involve a significant computational burden, which makes it more tractable to simulate other damage mechanisms in the same analysis.

Ratcliffe, James G.↗

Structural Analysis, Modeling, and Testing of Multi-nut Joint for TriTruss Structure

The Multi-nut joint, developed at NASA Langley Research Center (LaRC), was designed to assemble TriTruss modules for a doubly curved 65.6-feet telescope support structure. Axial and bending tests for a multi-nut joint in the TriTruss structure were conducted to characterize the structural performance of the multi-nut joint and to obtain the installation torque value of the attachment fastener. This paper describes the summary of the axial and bending tests of the multi-nut joint, along with the test results. The equivalent axial stiffness (EA) and equivalent bending stiffness (EI) of the multi-nut joint were characterized based on these test results and are presented in this report. Additionally, finite element models (FEMs) of the axial and bending test specimens were developed, and the predicted axial and bending responses of the multi-nut joint were compared with the test results. Test-analysis comparison results show that the predicted axial load-displacement response of the test specimen was within 5 percent of the test results, while the predicted load-bending response of the test specimen exhibited a consistent trend with the test data.

TriTruss↗

Structural Analysis, Modeling, and Testing of Multi-nut Joint for TriTruss Structure

The Multi-nut joint, developed at NASA Langley Research Center (LaRC), was designed to assemble TriTruss modules for a doubly curved 65.6-feet telescope support structure. Axial and bending tests for a multi-nut joint in the TriTruss structure were conducted to characterize the structural performance of the multi-nut joint and to obtain the installation torque value of the attachment fastener. This paper describes the summary of the axial and bending tests of the multi-nut joint, along with the test results. The equivalent axial stiffness (EA) and equivalent bending stiffness (EI) of the multi-nut joint were characterized based on these test results and are presented in this report. Additionally, finite element models (FEMs) of the axial and bending test specimens were developed, and the predicted axial and bending responses of the multi-nut joint were compared with the test results. Test-analysis comparison results show that the predicted axial load-displacement response of the test specimen was within 5 percent of the test results, while the predicted load-bending response of the test specimen exhibited a consistent trend with the test data.

Structural analysis↗

Empirical Assessment of the Appliance-Level Load Shape and Demand Response Potential in India

Over the next 15 years, electricity demand from the key residential and commercial appliances is projected to be nearly 300 GW or ~65% of India’s total peak demand. The objective of this study is to characterize appliance level demand and temporal variation, and identify the overall DR potential in India. We use Bangalore Electricity Supply Company territory (peak load of 3,505 MW in 2016) as a case study, using actual one-minute resolution load data for 2,979 distribution feeders and a detailed load survey. Our results show that agricultural pumping and space cooling (residential, commercial, and industrial) are the main contributors to the peak demand – with shares of 23-27% and 14-23%, respectively. Both sectors have about 1,000 MW of DR potential – agricultural pumps offering load shifting service while space cooling offering shimmy service that is capable of dynamically adjusting to react to short-run ramps and grid disturbances. Residential electric water heaters contribute nearly 18% of the winter morning peak demand and can also offer about 500 MW in shimmy service. Overall, we find that shifting and shimmy services offer 1,199 MW and 1,511 MW total DR potential, respectively.

demand response↗

Transactive control of fast-acting demand response based on thermostatic loads in real-time retail electricity markets

Coordinated operation of distributed thermostatic loads such as heat pumps and air conditioners can reduce energy costs and prevents grid congestion, while maintaining room temperatures in the comfort range set by consumers. This paper furthers efforts towards enabling thermostatically controlled loads (TCLs) to participate in real-time retail electricity markets under a transactive control paradigm. An agent-based approach is used to develop an effective and low complexity demand response control scheme for TCLs. The proposed scheme adjusts aggregated thermostatic loads according to real-time grid conditions under both heating and cooling modes. Here, a case study is presented showing the method reduces consumer electricity costs by over 10% compared to uncoordinated operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fast Primary Frequency Response using Coordinated DER and Flexible Loads: Framework and Residential-scale Demonstration

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (~8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast Primary Frequency Response Using Coordinated DER and Flexible Loads: Framework and Residential-Scale Demonstration: Preprint

Methods for supporting grid frequency stabilization using widespread flexible load and DER are becoming essential as the portion of synchronous generation decreases. This article develops a framework for providing fast primary frequency response that leverages deferrable loads and DER coordinated using high-speed measurements in real time to ensure that local objectives are met. The framework is demonstrated in a residential-scale experiment with four household appliances and an inverter. The effectiveness of an example load management algorithm is demonstrated using three underfrequency anomaly test cases. The experimental data corroborates that in all cases, the entire coordinated response, from detection and measurement of a frequency anomaly to completed coordinated net-load response, is completed within 143 ms (about 8.5 cycles).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Antenna Loading Impact on the Coupling Response of a Slotted Cylindrical Cavity

This report details the effect of antenna loading on the interior near - field response of a resonating cylindrical cavity characterized by a leaky aperture. We find a large field variation within the cavity when a long antenna is introduced within the interior and the antenna load is varied from 0 to 50 Ohms. We also find the effect of absorption losses to be negligible. In order to accurately characterize the coupling into the cavity, a non - perturbing sensor (such as a monopole) is recommended. With this approach, the interior field distribution and peak levels characterizing the cavity will be fairly well preserved. In addition to studying the impact of antenna loading on the interior near - field response, the resonant frequencies for the cylindrical structure perturbed by a subwavelength aperture are found to be well estimated by analytical computations.

47 OTHER INSTRUMENTATION↗

Sparse modeling of space- and time-varying diffraction response of a progressively loaded aluminum alloy

Highlights: • Plasticity induces crystal orientation and lattice spacing heterogeneity. • High energy x-ray diffraction spot broadening typically accompanies plasticity. • Method quantifies spot broadening in difficult, mixed microstructure data. • Algorithm finds sparse combination of entries from dictionary of peak functions. • Approach showed asymmetric plastic response in preprocessed AA7075 T651 sample. - Abstract: High energy X-ray diffraction data collected in situ during loading experiments permits probing of the crystal structure of a plastically deforming material sample. An elastoplastic deformation is associated with heterogeneity in both crystal orientation and lattice spacing—each manifesting as azimuthal broadening and radial broadening of diffraction peaks respectively. Quantifying the spreading effect is challenging, especially in cases where the sample has a granularity between that of a single crystal and fine grain or powder material. The approach developed in this paper begins by modeling the intensity signal in the vicinity of a Debye-Scherrer ring as a sparse, nonnegative superposition of Gaussian basis functions drawn from an over-complete dictionary. Processing automatically selects from the dictionary basis functions whose widths and amplitudes are representative of the data. The chosen basis functions are used to compute scalar measures of radial and azimuthal broadening for the set of diffraction peaks composing a Debye-Scherrer ring. To demonstrate the utility of the approach, we show that analysis of diffraction peak shape information from an aluminum alloy 7075 T651 (AA7075 T651) sample provides insight into the origin of material state that would have otherwise have been difficult if not impossible to extract using conventional methods. Furthermore, the extracted information revealed a deformation response linked to the processing history of the sample.

36 MATERIALS SCIENCE↗

Experimental Characterization of Hysteresis in a Revolute Joint for Precision Deployable Structures

Recent studies of the micro-dynamic behavior of a deployable telescope metering truss have identified instabilities in the equilibrium shape of the truss in response to low-energy dynamic loading. Analyses indicate that these micro-dynamic instabilities arise from stick-slip friction within the truss joints (e.g., hinges and latches). The present study characterizes the low-magnitude quasi-static load cycle response of the precision revolute joints incorporated in the deployable telescope metering truss, and specifically, the hysteretic response of these joints caused by stick-slip friction within the joint. Detailed descriptions are presented of the test setup and data reduction algorithms, including discussions of data-error sources and data-filtering techniques. Test results are presented from thirteen specimens, and the effects of joint preload and manufacturing tolerances are investigated. Using a simplified model of stick-slip friction, a relationship is made between joint load-cycle behavior and micro-dynamic dimensional instabilities in the deployable telescope metering truss.

Lake, Mark S.↗

Improving Wind Turbine Drivetrain Reliability Using a Combined Experimental, Computational, and Analytical Approach

Nontorque loads induced by the wind turbine rotor overhang weight and aerodynamic forces can greatly affect drivetrain loads and responses. If not addressed properly, these loads can result in a decrease in gearbox component life. This work uses analytical modeling, computational modeling, and experimental data to evaluate a unique drivetrain design that minimizes the effects of nontorque loads on gearbox reliability: the Pure Torque(R) drivetrain developed by Alstom. The drivetrain has a hub-support configuration that transmits nontorque loads directly into the tower rather than through the gearbox as in other design approaches. An analytical model of Alstom's Pure Torque drivetrain provides insight into the relationships among turbine component weights, aerodynamic forces, and the resulting drivetrain loads. Main shaft bending loads are orders of magnitude lower than the rated torque and are hardly affected by wind conditions and turbine operations.

17 WIND ENERGY↗