Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample average approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Biogeochemistry of the Antrim Shale Natural Gas Reservoir

The Antrim Shale, located in the Michigan Basin, United States (U.S.), is a major U.S. shale play having produced over 2.5 Trillion Cubic Feet (Tcf) of unconventional shale natural gas as of 2010. The shallow nature of this formation sets it apart from other, more characterized unconventional shale gas plays. The depth of gas production of the Antrim ranges from approximately 150 to 600 m and it is typically vertically drilled, contrary to deeper, horizontally drilled shales. A thorough understanding of the biogeochemistry and microbiology of this complex system will be advantageous for improving well performance, produced water management, and potential biocidal treatment as microbial community composition can vary substantially even among closely spaced wells. In this study, we analyzed produced water collected from nine different wells in the Antrim Shale by investigating the geochemical and microbial community composition of the produced water to gain greater insight into the overall biogeochemistry of this unique shale system. The majority of the wells from this study had high total dissolved solids (TDS) primarily composed of chloride and sodium, averaging 86,804 mg/L with a maximum 116,223 mg/L; however, three of the wells sampled along the northern margin of the basin exhibited significantly lower TDS ranging from 4932 to 6496 mg/L. Overall, our microbial community analysis revealed relatively low abundance within our samples and high variability of the microbial community among the sampled wells. The majority of bacterial sequences were identified within Proteobacteria, Firmicutes, and Actinobacteria phyla and metagenomic sequencing revealed the low presence of Methanobacteriaceae within each sample. We also investigated potential microbial community drivers and found that TDS, sodium, chloride, iodide, bromide, ammonium, potassium, and strontium were significantly correlated with the observed microbial community. The varying geochemical conditions between wells demonstrate different subsurface environmental niches, potentially driving the heterogeneous microbial communities we observed from well to well. This analysis suggests an important relationship between both well location and geochemistry and the observed microbial community that can persist in the reservoir. Continued studies of the Antrim Shale will improve our understanding of the complex interdependencies of this ecosystem.

03 NATURAL GAS↗

SAIL Storm Boards 2022-2023

“Storm Boards” are simple installations comprised of a horizontal white plastic board that is placed in situ on the surface of the snowpack with a 1 m vertical marker pole for identifying the board center and approximate new snow height. Storm boards allow newly fallen snow to accumulate on them while staying separated from moisture and energy exchange with the snowpack, thus creating a discrete sample of newly fallen snow depth & SWE (snow water equivalent) that can be measured to calculate the net moisture input of individual or multiple storm events to the seasonal snowpack. Samples are measured with a 2” diameter plastic tube that allows the observer to non destructively take a snow core of the newly deposited snow; this core is weighed with a small hand scale - then the mass of the sample is converted to SWE. Depth of the snow sample is obtained with a snow depth probe or from graduated marks on the plastic tube. 3 or more replicate samples are taken for each board measurement and averaged. Total snow height (HS) of the snowpack is measured with a snow depth probe for each site & timepoint to track snowpack accumulation/ablation.

54 ENVIRONMENTAL SCIENCES↗

Unsteady Pressure Acquisition on the 1.75% Scale SLS Block 1B Cargo Liftoff Configuration

Time-varying pressure on the core of the Space Launch System (SLS) Block 1B Cargo vehicle was acquired using instrumentation typically used for steady, time averaged pressure. Resono Pressure Systems, Inc. in partnership with the University of Wyoming have developed a unique hardware and software system for measuring unsteady pressure, which was implemented in a large-scale wind tunnel test through a nonreimbursable Space Act Agreement with NASA. The technique was applied to 12 pressure ports on the 1.75% scale SLS wind tunnel model. Tubing lengths of approximately 14 inches separated the pressure transducer module from the pressure taps on the model surface, and surface-mount validation sensors (Kulites) were installed in close proximity to 5 of the 12 pressure ports. Up to about 500 Hz, the frequency response of pressure fluctuations agreed to within 1 dB of amplitude and 10° of phase difference compared to the simultaneously-acquired surface-mount transducers. Sample results using the reconstructed pressure from the full azimuthal ring of taps are presented.

unsteady pressure↗

Nuclear Waste Tank Emission Contributions to Particle Size Distribution

Pollutants from anthropogenic activities including industrial processes are ubiquitous to the environment. To understand the impact from industrial aerosol on climate and human health, industrial aerosol needs to be better characterized. Here, in this study, particle number concentrations were used as a proxy for atmospheric pollutants, which include both particles and gases. Particle concentration and size distribution were measured using a scanning mobility particle sizer (SMPS) approximately 4.5 km from primary industrial areas at the Savannah River Site in Aiken, SC. Industrial areas include numerous nuclear waste storage and processing tanks. The SMPS data were divided into two groups depending on the wind direction measured onsite to categorize transport from the industrial area or from elsewhere. Industrial contributions were found to have a higher concentration of particles with sizes less than 200 nm, 859 ± 564 cm -3 , in comparison to non-industrial attributed particles, 733 ± 495 cm -3 on average from March-July 2021. For sizes larger than 200 nm, industrial and non-industrial particles have a similar concentration, 89 ± 59 cm -3 and 99 ± 61 cm -3 , with non-industrial concentrations being slightly larger. To confirm that industrial particles could travel to the sampling location, air dispersion modeling was completed for specific case studies during the sampling period. The atmospheric dispersion modeling results confirmed that particles released at the industrial areas reached the sampling location when the wind direction was favorable for transport from the industrial areas. The greater concentration of smaller-sized particles in industrial emissions has implications for typical particulate measurements (PM2.5), heath impacts, and climatological influences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Global Multi-Resolution Terrain Elevation Data 2010 (GMTED2010) Using ICESat Geodetic Control

Supported by NASA's Earth Surface and Interior (ESI) Program, we are producing a global set of Ground Control Points (GCPs) derived from the Ice, Cloud and land Elevation Satellite (ICESat) altimetry data. From February of 2003, to October of 2009, ICESat obtained nearly global measurements of land topography (+/- 86deg latitudes) with unprecedented accuracy, sampling the Earth's surface at discrete approx.50 m diameter laser footprints spaced 170 m along the altimetry profiles. We apply stringent editing to select the highest quality elevations, and use these GCPs to characterize and quantify spatially varying elevation biases in Digital Elevation Models (DEMs). In this paper, we present an evaluation of the soon to be released Global Multi-resolution Terrain Elevation Data 2010 (GMTED2010). Elevation biases and error statistics have been analyzed as a function of land cover and relief. The GMTED2010 products are a large improvement over previous sources of elevation data at comparable resolutions. RMSEs for all products and terrain conditions are below 7 m and typically are about 4 m. The GMTED2010 products are biased upward with respect to the ICESat GCPs on average by approximately 3 m.

Carabajal, Claudia C.↗

An Analysis of Peak Wind Speed Data from Collocated Mechanical and Ultrasonic Anemometers

This study compared peak wind speeds reported by mechanical and ultrasonic anemometers at Cape Canaveral Air Force Station and Kennedy Space Center (CCAFS/KSC) on the east central coast of Florida and Vandenberg Air Force Base (VAFB) on the central coast of California. Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at CCAFS/KSC and VAFB for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The legacy CCAFS/KSC and VAFB weather tower wind instruments are being changed from propeller-and-vane (CCAFS/KSC) and cup-and-vane (VAFB) sensors to ultrasonic sensors under the Range Standardization and Automation (RSA) program. Mechanical and ultrasonic wind measuring techniques are known to cause differences in the statistics of peak wind speed as shown in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between the RSA ultrasonic and legacy mechanical sensors to determine if there are significant differences. Note that the instruments were sited outdoors under naturally varying conditions and that this comparison was not designed to verify either technology. Approximately 3 weeks of mechanical and ultrasonic wind data from each range from May and June 2005 were used in this study. The CCAFS/KSC data spanned the full diurnal cycle, while the VAFB data were confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on five different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The ten towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The ultrasonic sensors were collocated at the same vertical levels as the mechanical sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with mechanical sensors were compared. The 1- minute average wind speed/direction and the 1-second peak wind speed/direction were compared.

Short, David A.↗

Validation of a New NIRS Method for Measuring Muscle Oxygenation During Rhythmic Handgrip Exercise

Near infrared spectroscopy (NIRS) is commonly used to measure muscle oxygenation during exercise and recovery. Current NIRS algorithms do not account for variation in water content and optical pathlength during exercise. The current effort attempts to validate a newly developed NIRS algorithm during rhythmic handgrip exercise and recovery. Six female subjects, aver age 28 +/- 6 yrs, participated in the study. A venous catheter was placed in the retrograde direction in the antecubital space. A NIRS sensor with 30 mm source-detector separation was placed on the flexor digitorum profundus. Subjects performed two 5-min bouts of rhythmic handgrip exercise (2 s contraction/1 s relaxation) at 15% and 30% of maximal voluntary contraction. Venous blood was sampled before each bout, during the last minute of exercise, and after 5 minutes of recovery. Venous oxygen saturation (SvO2) was measured with a I-stat CG-4+ cartridge. Spectra were collected between 700-900 nm. A modified Beer's Law formula was used to calculate the absolute concentration of oxyhemoglobin (HbO2), deoxyhemoglobin (Hb) and water, as well as effective pathlength for each spectrum. Muscle oxygen saturation (SmO2) was calculated from the HbO2 and Hb results. The correlation between SvO2 and SmO2 was determined. Optical pathlength and water varied significantly during each exercise bout, with pathlength increasing approximately 20% and water increasing about 2%. R2 between blood and muscle SO2 was found to be 0.74, the figure shows the relationship over SvO2 values between 22% and 82%. The NIRS measurement was, on average, 6% lower than the blood measurement. It was concluded that pathlength changes during exercise because muscle contraction causes variation in optical scattering. Water concentration also changes, but only slightly. A new NIRS algorithm which accounts for exercise-induced variation in water and pathlength provided an accurate assessment of muscle oxygen saturation before, during and after exercise.

Hagan, R. Donald↗

A Comparison of Wind Speed Data from Mechanical and Ultrasonic Anemometers

This study compared the performance of mechanical and ultrasonic anemometers at the Eastern Range (ER; Kennedy Space Center and Cape Canaveral Air Force Station on Florida's Atlantic coast) and the Western Range (WR; Vandenberg Air Force Base on California's Pacific coast). Launch Weather Officers, forecasters, and Range Safety analysts need to understand the performance of wind sensors at the ER and WR for weather warnings, watches, advisories, special ground processing operations, launch pad exposure forecasts, user Launch Commit Criteria (LCC) forecasts and evaluations, and toxic dispersion support. The current ER and WR weather tower wind instruments are being changed from the current propeller-and-vane (ER) and cup-and-vane (WR) sensors to ultrasonic sensors through the Range Standardization and Automation (RSA) program. The differences between mechanical and ultrasonic techniques have been found to cause differences in the statistics of peak wind speed in previous studies. The 45th Weather Squadron (45 WS) and the 30th Weather Squadron (30 WS) requested the Applied Meteorology Unit (AMU) to compare data between RSA and current sensors to determine if there are significant differences. Approximately 3 weeks of Legacy and RSA wind data from each range were used in the study, archived during May and June 2005. The ER data spanned the full diurnal cycle, while the WR data was confined to 1000-1600 local time. The sample of 1-minute data from numerous levels on 5 different towers on each range totaled more than 500,000 minutes of data (482,979 minutes of data after quality control). The 10 towers were instrumented at several levels, ranging from 12 ft to 492 ft above ground level. The RSA sensors were collocated at the same vertical levels as the present sensors and typically within 15 ft horizontally of each another. Data from a total of 53 RSA ultrasonic sensors, collocated with present sensors were compared. The 1-minute average wind speed/direction and the 1-second peak wind speed/direction were compared.

Short, D.↗

The growth of intracluster light in XCS-HSC galaxy clusters from 0.1 < z < 0.5

ABSTRACT We estimate the intracluster light (ICL) component within a sample of 18 clusters detected in the XMM Cluster Survey (XCS) data using the deep (∼26.8 mag) Hyper Suprime-Cam Subaru Strategic Programme data release 1 i-band data. We apply a rest-frame μB = 25 mag arcsec−2 isophotal threshold to our clusters, below which we define light as the ICL within an aperture of RX,500 (X-ray estimate of R500) centred on the brightest cluster galaxy (BCG). After applying careful masking and corrections for flux losses from background subtraction, we recover ∼20 per cent of the ICL flux, approximately four times our estimate of the typical background at the same isophotal level (${\sim}5{{\ \rm per\ cent}}$). We find that the ICL makes up about ${\sim}24{{\ \rm per\ cent}}$ of the total cluster stellar mass on average (∼41 per cent including the flux contained in the BCG within 50 kpc); this value is well matched with other observational studies and semi-analytic/numerical simulations, but is significantly smaller than results from recent hydrodynamical simulations (even when measured in an observationally consistent way). We find no evidence for any links between the amount of ICL flux with cluster mass, but find a growth rate of 2–4 for the ICL between 0.1 < z < 0.5. We conclude that the ICL is the dominant evolutionary component of stellar mass in clusters from z ∼ 1. Our work highlights the need for a consistent approach when measuring ICL alongside the need for deeper imaging, in order to unambiguously measure the ICL across as broad a redshift range as possible (e.g. 10-yr stacked imaging from the Vera C. Rubin Observatory).

Furnell, Kate E.↗

The Vertical Structure of Relative Humidity and Ozone in the Tropical Upper Troposphere: Intercomparisons Among In Situ Observations, A-Train Measurements and Large-Scale Models

In situ measurements in the tropics have shown that in regions of active convection, relative humidity with respect to ice in the upper troposphere is typically close to saturation on average, and supersaturations greater than 20% are not uncommon. Balloon soundings with the cryogenic frost point hygrometer (CFH) at Costa Rica during northern summer, for example, show this tendency to be strongest between 11 and 15.5 km (345-360 K potential temperature, or approximately 250-120 hPa). this is the altitude range of deep convective detrainment. Additionally, simultaneous ozonesonde measurements show that stratospheric air (O3 greater than 150 ppbv) can be found as low as approximately 14 km (350 K/150 hPa). In contrast, results from northern winter show a much drier upper troposphere and little penetration of stratospheric air below the tropopause at 17.5 km (approximately 383 K). We show that these results are consistent with in situ measurements from the Measurement of Ozone and water vapor by Airbus In-service airCraft (MOZAIC) program which samples a wider, though still limited, range of tropical locations. To generalize to the tropics as a whole, we compare our insitu results to data from two A-Train satellite instruments, the Atmospheric Infrared Sounder (AIRS) and the Microwave Limb Sounder (MLS) on the Aqua and Aura satellites respectively. Finally, we examine the vertical structure of water vapor, relative humidity and ozone in the NASA Goddard MERRA analysis, an assimilation dataset, and a new version of the GEOS CCM, a free-running chemistry-climate model. We demonstrate that conditional probability distributions of relative humidity and ozone are a sensitive diagnostic for assessing the representation of deep convection and upper troposphere/lower stratosphere mixing processes in large-scale analyses and climate models.

Selkirk, Henry B.↗

Demonstration of VOC Fenceline Sensors and Canister Grab Sampling near Chemical Facilities in Louisville, Kentucky

Experimental fenceline sensor pods (SPods) fitted with 30 s duration canister grab sampling (CGS) systems were deployed at a site near chemical facilities in Louisville, KY, from 4 June 2018 to 5 January 2020. The objective of the study was to better understand lower cost 10.6 eV photoionization detector (PID)-based volatile organic compound (VOC) sensors and investigate their utility for near-source emissions detection applications. Prototype SPods containing PID sensor elements from two different manufacturers yielded between 78% and 86% valid data over the study, producing a dataset of over 120,000 collocated pair fenceline measurements averaged into 5-min datapoints. Ten-second time-resolved SPod data from an elevated fenceline sensor signal day are presented, illustrating source emission detections from the direction of a facility 500 m west of the monitoring site. An SPod-triggered CGS acquired in the emission plume on this day contained elevated concentrations of 1,3-butadiene and cyclohexane (36 parts per billion by volume (ppbv) and 637 ppbv, respectively), compounds known to be emitted by this facility. Elevated concentrations of these compounds were observed in a subset of the 61 manual and triggered CGS grab samples acquired during the study, with winds from the west. Using novel wind-resolved visualization and normalization approaches described herein, the collocated pair SPod datasets exhibited similarity in emission source signature. With winds from the west, approximately 50% of SPod readings were above our defined theoretical detection limit indicating persistent measurable VOC signal at this site. Overall, this 19-month study demonstrated reasonable prototype SPod operational performance indicating that improved commercial forms of lower cost PID sensors could be useful for select VOC fenceline monitoring applications.

1,3-butadiene↗

Observations from Long-Term Performance Monitoring of the TOPEX Radar Altimeter

From its August 1992 launch to the present, we have performed performance analysis and engineering assessment for the TOPEX radar altimeter. We continually update databases containing: (1) on-board engineering parameters such as temperatures, voltages, and currents; (2) internal calibration mode indications of bias changes in range and power estimates; and (3) global over-ocean averages of geophysical quantities such as significant waveheight (SWH) and ocean surface radar backscattering cross-section (sigmaO). For some time now we have seen an apparent increase in the TOPEX cycle-average SWH, amounting now to an increase of about 10% from our earlier mission value of about 2.8 m. Recently several investigators have reported that the TOPEX SWH is increasing relative to ERS-2 and to ocean buoy measurements. We examined the past six years of waveform data from an internal calibration mode (Cal 1) which samples the altimeter's point target response (ptr), and found that the ptr sidelobes are apparently greater now than at start of mission. Modeling studies indicate that the sidelobe enhancement can account for most of the increase in the TOPEX SWH estimate; that is, the SWH increase is not real but result of some drift within the altimeter. Our modeling indicates that the TOPEX range estimates will change less than a centimeter for ptr changes seen to date. An approximate recipe for correcting the TOPEX SWH values will be made available on our web site (http://topex.wffnasa.gov/). We emphasize that a radar altimeter is a complex system requiring continuing calibration and monitoring throughout its entire lifetime.

Hayne, G. S.↗

Lightning Return-Stroke Current Waveforms Aloft, from Measured Field Change, Current, and Channel Geometry

Three-dimensional reconstructions of six rocket-triggered lightning channels are derived from stereo photographs. These reconstructed channels are used to infer the behavior of the current in return strokes above the ground from current waveforms measured at the channel base and electric-field-change waveforms measured at a range of 5.2 kilometers for 24 return strokes in these channels. Streak photographs of 14 of the same strokes are analyzed to determine the rise times, propagation speeds, and amplitudes of relative light intensity for comparison with the electrical inferences. Results include the following: 1) The fine structure of the field-change waveforms that were radiated by these subsequent return strokes can be explained, in large part, by channel geometry. 2) The average 10 - 90% rise time of the stroke current increased by about a factor of seven in our sample, from an observed 0.31 plus or minus 0.17 microseconds at the surface to an inferred 2.2 plus or minus 0.5 microcseconds at 1 kilometer path length above the surface. 3) The three-dimensional propagation speed of the current front averaged 1.80 plus or minus 0.24 X 10(exp 8) meters per second over channel lengths typically greater than 1 kilometer. 4) Assuming that the measured current was entirely due to the return stroke forced an unreasonably large and abrupt reduction in inferred current amplitude over the first few tens of meters above the surface, especially in cases when the leader was bright relative to its stroke. Therefore, a significant fraction of the current at the surface was probably due to the leader, at least in such cases. 5) Peak return-stroke currents decreased by approximately 37 plus or minus 12% from 100 meters to 1 kilometer of path length above the surface. Because of uncertainty about how to partition the measured current between leader and return stroke, we are unable to infer the variation of current amplitude near the ground.

Willett, J. C.↗

R-matrix Resolved Resonance Region Evaluation of 140,142 Ce

Oak Ridge National Laboratory completed the resolved resonance region (RRR) evaluation of the two most abundant cerium isotopes, 140 Ce (88.45%) and 142 Ce (11.11%), as requested by the US Nuclear Criticality Safety Program. These evaluations are based on recent high-resolution transmission and capture measurements performed on nat Ce and highly enriched 142 Ce samples at the JRC-Geel Linear Accelerator facility, as well as measured thermal constants available from the EXFOR database. Starting from the resonance parameters of the ENDF/B-VIII.0 library followed by a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information were derived by fitting these measured data using the Reich–Moore approximation of the R -matrix theory, as implemented in the SAMMY code system. The 140 Ce RRR upper energy limit was kept at 200 keV, whereas the 142 Ce resonance region was extended from 13 to 26 keV. Updated statistical properties were obtained for the new evaluations and compared to those derived from the ENDF/B-VIII.0 nuclear data library. The new evaluation work improved some of the discrepancies found in previous work, such as the capture resonance integral and stellar Maxwellian-averaged cross sections. These integral quantities were mainly derived from the fit of the latest measured data, especially the neutron capture yield data for 142 Ce isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon, Nitrogen, and Sulfur Analysis of the Cetama Viognier Standard Reference Material

The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Satellite-Based Global Precipitation Data Sets at Monthly and Finer Time Scales

A new 20-year, monthly, globally complete precipitation analysis has been completed as part of the World Climate Research Program's (WCRP/GEWEX) Global Precipitation Climatology Project (GPCP). The global, monthly, 2.5 deg x 2.5 deg latitude-longitude product utilizes precipitation estimates from low-orbit microwave sensors (SSM/1) and geosynchronous IR sensors and raingauge information over land. The low-orbit microwave estimates are used to adjust or correct the geosynchronous IR estimates, thereby maximizing the utility of the more physically-based microwave estimates and the finer time sampling of the geosynchronous data. The 20-year climatology of the Version 2 GPCP analysis indicates the expected features of a very strong Pacific Ocean ITCZ and SPCZ with maximum 20-year means approaching 10 mm/day. A similar strength maximum over land is evident over Borneo. Weaker maxima in the tropics occur in the Atlantic ITCZ and over South America and Africa. In mid-latitudes of the Northern Hemisphere the Western Pacific and Western Atlantic maxima have values of approximately 7 mm/day, while in the Southern Hemisphere the mid-latitude maxima are located southeast of Africa, in mid-Pacific as an extension of the SPCZ and southeast of South America. In terms of global totals the GPCP analysis shows 2.7 mm/day (3.0 mm/day over ocean; 2.1 mm/day over land), similar to the Jaeger climatology, but not other climatologies. Zonal averages peak at 6 mm/day at 7 deg N with mid-latitude peaks of about 3 mm/day at 40-45 deg latitude. Poleward of 45 deg the GPCP analysis shows larger zonally-averaged values than most previous satellite-based estimates, although the values are similar to the Jaeger climatology.

Adler, Robert↗