Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Inorganic and protein crystal growth - Similarities and differences

Transport and interface kinetic concepts for the design and control of inorganic crystal growth experiments are reviewed, and their applications and limitations in protein crystal growth are considered. It is suggested that the interfacial concentration gradients are steeper for faster crystallization, and that the interfacial concentration distributions for the protein and the precipitant can differ significantly. Results show that uniformity in crystal composition and steady-state conditions in growth kinetics are favored by larger sample size, since surface-tension gradients drive strong in microgravity experiments and in small samples on earth.

Rosenberger, F.↗

X-Ray Diffraction Based Phase Identification in NiTiHf Shape Memory Alloys with Variable Hf Content

NiTiHf type shape memory alloys have been studied for use in high temperature actuator applications, the most studied of which is the NiTi-20Hf atomic % composition. In this study, six samples of NiTi-Hf including 20Hf, 30Hf, 35Hf, 40Hf, 45Hf, and 50Hf were evaluated by both 1D and 2D X-ray diffraction (XRD) to elucidate what phases and crystal structures were present at room temperature. Given small sample sizes and relatively large grains, multiple cross-sections were measured to increase the sampling statistics, and 2D XRD frames were collected to corroborate the 1D XRD data. Rietveld and structureless refinements were both performed, allowing for adjustments in orientation lattice constant, and structure factor. At room temperature, the primary martensitic phase in the NiTiHf alloys with 20 at% and lower Hf is a monoclinic B19’ phase (P1121/m space group). This phase was identifiable, even in small amounts, in the higher Hf samples. The primary phase in the 30 -50 at% Hf samples is an orthorhombic B33 (Cmcm space group) phase. This work supported thermal analyses indicating the phase transition paths from the two different room temperature martensitic phases to the B2 austenitic phase.

Laura Wilson↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Predictive Engineering Tools for Injection-Molded Long-Carbon-Fiber Thermoplastic Composites (FY 2015 Third Quarterly Report)

During the third quarter of FY 2015, the following technical progress has been made toward project milestones: 1) Magna oversaw the tool build and prepared the molding plan for the complex part of Phase II. 2) PlastiComp hosted a visit by Magna and Toyota on April 23rd to finalize the molding scope and schedule. The plan for molding trials including selection of molding parameters for both LFT and D-LFT for the U-shape complex part was established. 3) Toyota shipped the U-shape complex part tool to Magna on May 28th, 2015. 4) Plasticomp provided 30wt% LCF/PP and 30wt% LCF/PA66 compounded pellets to Magna for molding the complex part. 5) Magna performed preliminary molding trials on June 2nd, 2015 to validate wall thickness, fill profile, tool temperature and shot size requirements for the complex part. 6) Magna performed the first complex part run on June 16th and 17th, 2015 at Magna’s Composite Centre of Excellence in Concord, ON, Canada. Dale Roland of Plasticomp, and Umesh Gandhi of Toyota also attended the molding. 7) Magna discussed and finalized the plan with PNNL and the team for cutting samples from molded parts at selected locations for fiber orientation and length measurements. 8) Magna provided the computer-aided design (CAD) files of the complex parts with and without ribs to PNNL and Autodesk to build the corresponding ASMI models for injection molding simulations. Magna also provided the actual parameters used. 9) Plasticomp’s provided knowledge and experience of molding LCF materials essential to the successful molding of the parts including optimization of fill speed, tool temperatures, and plasticizing conditions for the 30wt% LCF/PP and 30wt% LCF/PA66 materials in both rib and non-rib versions. 10) Magna molded additional parts for evaluation of mechanical property testing including torsional stiffness on June 29th and 30th, 2015 at Magna’s Composite Center of Excellence. 11) Toyota began preparation for the torsion test of the specimens. Preparation of a computer-aided engineering (CAE) model to predict the performance is in progress. 12) Autodesk fixed an error in the implementation of the proper orthogonal decomposition (POD) calculation of fiber length that had caused the ASMI solution to crash and provided an updated build of ASMI containing the fix. 13)Autodesk reviewed and provided feedback for the complex part molding and measurement locations. 14) Autodesk provided support to set up the workflow for ASMI-ABAQUS® analysis, and provided a fix and workaround for a bug in the ASMI-ABAQUS® output command. 15) Autodesk helped build ASMI analysis models for the complex parts with and without ribs. 16) Autodesk worked on improving the orientation prediction accuracy in the shearing layer for 3D meshes based on comparison to measured data of the plaque moldings. 17) PNNL installed a new ASMI version received from Autodesk and performed comparative analyses to assess mid-plane versus 3D fiber length predictions using the full fiber length model and the reduced-order model (ROM) using POD. 18) PNNL presented the project scope, accomplishments, significant results and future plans to DOE and the USCAR Materials Tech Team on June 3rd, 2015. 19) PNNL discussed the cutting of samples from molded parts and finalized a plan with Magna and the team suggesting the sample size, locations and number of samples per location. 20) PNNL and Autodesk built ASMI models for the complex parts with and without ribs, and preliminary analyses of the part with ribs were conducted using the actual molding parameters received from Magna. 21) PNNL worked on a procedure to extract fiber orientation and length results from a 3D ASMI analysis to a 3D ABAQUS model. This procedure is essential to import ASMI fiber orientation and length to a 3D ABAQUS model of the part allowing future part structural analysis for weight reduction study.

36 MATERIALS SCIENCE↗

Gravity Sensors and the Role of 3-D Visualization and Simulation in Biomedical Research

Ross 3.0 software was developed in the Biocomputation Center for semi-automated reconstruction of objects from serial thin sections. Data are captured directly from a transmission electron microscope via a video camera to a graphics workstation where the sections are mosaicked and contours are traced, registered and displayed by semi-automated methods. For the first time, macular type II cells are described completely for their innervation patterns. The purposes are to learn more about the fundamental circuitry of the macula and to demonstrate whether the terminals are altered morphologically by space flight. Current examples, from the medial part of the macula, are from maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that the typical type 11 cell receives processes from up to six nearby calyces or afferents. Nearly all the processes are elongated; some have bouton-like swellings and numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approx. 1/3 of the processes innervate 2 type II cells of a neighboring cluster of 3 cells. About 2% of type II cells resemble type I cells morphologically and are surrounded by demicalyces. Differences in size or shape of the terminals under flight conditions could not be determined because the sample size is still too small; but it is clear that reconstruction methods provide insights into macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields, through feedback-feedforward connections, during preprocessing of linear acceleratory information by the maculas. While the methods are currently being tested using vestibular maculas as the model system, it is clear that the technology is applicable to any tissue that can be physically or optically sectioned. ROSS software has already been implemented for reconstructing objects from tissues studied by confocal and by transmitted light microscopy, and research into magnetic resonance imaging-computational tomography combined visualization are underway.

Ross, Muriel D.↗

Non-equilibrium freezing of water-ice in sandy basaltic regoliths and implications for fluidized debris flows on Mars

Many geomorphic features on Mars were attributed to Earth-analogous, cold-climate processes involving movement of water or ice lubricated debris. Clearly, knowledge of the behavior of water in regolith materials under Martian conditions is essential to understanding the postulated geomorphic processes. Experiments were performed with sand-sized samples of natural basaltic regoliths in order to further elucidate how water/regolith interactions depend upon grain size and mineralogy. The data reveal important contrasts with data for clay-mineral substrates and suggest that the microphysics of water/mineral interactions might affect Martian geomorphic processes in ways that are not fully appreciated. Sand and silt sized fractions of two soils from the summit of Mauna Kea were used as Mars-analogous regolith materials. Temperatures were measured for water/ice phase transitions as wet slurries of individual soil fractions which were cooled or heated at controlled rates under a carbon dioxide atmosphere. Freezing and melting of ice was studied as a function of water/soil mass ratio, soil particle size, and thermal-cycle rate. Comparison tests were done under the same conditions with U.S. Geological Survey standard rock powders.

Gooding, J. L.↗

Sm-Nd, Rb-Sr, and Mn-Cr Ages of Yamato 74013

Yamato 74013 is one of 29 paired diogenites having granoblastic textures. The Ar-39 - Ar-40 age of Y-74097 is approximately 1100 Ma. Rb-Sr and Sm-Nd analyses of Y-74013, -74037, -74097, and -74136 suggested that multiple young metamorphic events disturbed their isotopic systems. Masuda et al. reported that REE abundances were heterogeneous even within the same sample (Y-74010) for sample sizes less than approximately 2 g. Both they and Nyquist et al. reported data for some samples showing significant LREE enrichment. In addition to its granoblastic texture, Y-74013 is characterized by large, isolated clots of chromite up to 5 mm in diameter. Takeda et al. suggested that these diogenites originally represented a single or very small number of coarse orthopyroxene crystals that were recrystallized by shock processes. They further suggested that initial crystallization may have occurred very early within the deep crust of the HED parent body. Here we report the chronology of Y-74013 as recorded in chronometers based on long-lived Rb-87 and Sm-147, intermediate- lived Sm-146, and short-lived Mn-53.

Nyquist, L. E.↗

Correlations between environmental parameters and nuclear activity

The occurrence and quantitative properties of Seyfert 1 and Seyfert 2 galaxies as a function of the galaxy environment were studied in a systematic way. For this investigation the authors selected from the Catalogue of Quasars and Active Nuclei (Veron & Veron, 1989) all Seyfert galaxies with the following properties: (1) m sub V less than or equal to 15; (2) listed classification as Sey 1, Sey 2, or Sey 3; (3) v sub rad less than or equal to 20,000 km s(sup -1). This results in a sample size of 242 Seyfert galaxies. For all these objects their galaxy environment was inspected on plates. The vicinity of each sample Seyfert galaxy was searched for companion galaxies out to at least 0.5 Mpc. Lacking redshift information, the authors adopted as a companion galaxy any galaxy in this area having a size between 20 and 200 percent of the Seyfert galaxy size. As an important environmental parameter for Seyfert activity, the authors consider the galaxy density within an environment of 500 kpc radius. They distinguish four density classes: D1: no companion (isolated Seyfert); D2: 1 companion; D3: 2 to 5 companions (group); and D4: less than or equal to 6 companions (dense group). The distribution of the various Seyfert classes among these density classes is listed in tabular form, both in absolute numbers and in percentages (given in brackets). From these statistics the environments of Sey 1, Sey 2, and Sey 3 galaxies do not differ in general with the exception that among the isolated galaxies the Seyfert 1 galaxies dominate conspicuously. No significant dependence of morphological type (de Vaucouleurs T-type) on density class is observed both for Sey 1 and Sey 2 galaxies. On the basis of an extensive search of the Seyfert literature the authors also investigated the dependence of the intrinsic parameters of the sample Seyfert galaxies on density class.

Kollatschny, W.↗

Deep Learning Estimation of Daily Ground–Level NO 2 Concentrations from Remote Sensing Data

The limited number of nitrogen dioxide (NO 2 ) surface measurements calls for the development of highly accurate approaches to estimating surface NO 2 concentrations. In this study, we leverage a new satellite instrument, the TROPOspheric Monitoring Instrument (TROPOMI), along with other predictor variables, to estimate daily surface NO 2 concentrations over Texas in 2019. We use the deep convolutional neural network (Deep-CNN), an advanced deep learning algorithm, to obtain estimates and achieve a correlation coefficient (R) of 0.91, an index of agreement (IOA) of 0.95, and a mean absolute bias (MAB) of 1.75 ppb in surface NO 2 estimation. Additionally, we leverage a novel approach, SHapley Additive exPlanations (SHAP), to describe how Deep-CNN understands each predictor variable. The SHAP results show that the Deep-CNN model has an advanced understanding of the dataset, revealing that TROPOMI closely captures levels of NO 2 . In addition, we show the superiority of our Deep-CNN model at estimating surface NO 2 over other well-known machine learning and regression models in the field, including the support vector machines (SVM), random forest (RF), and multiple linear regression (MLR). Although SVM and RF show strong capabilities at estimating surface NO 2 concentrations, their accuracy is inferior to that of the Deep-CNN model, ranking second and third in model accuracy in this study. The MLR, however, shows a poor ability at NO 2 estimation and ranks last among all models. Furthermore, testing the impact of sample size on model performance, we also show that, compared to other models, Deep-CNN needs more samples to trigger its strength at surface NO 2 estimation.

54 ENVIRONMENTAL SCIENCES↗

Fibreoptic fluorescent microscopy in studying biological objects

The method of fluorescent microscopy is developed based on employment of a single-mode fibreoptic channel to provide high spatial resolution 3D images of large cleared biological specimens using the 488-nm excitation laser line. The transverse and axial resolution of the setup is 5 and 13 {mu}m, respectively. The transversal sample size under investigation is up to 10 mm. The in-depth scanning range depends on the sample transparency and reaches 4 mm in the experiment. The 3D images of whole mouse organs (heart, lungs, brain) and mouse embryos obtained using autofluorescence or fluorescence of exogenous markers demonstrate a high contrast and cellular-level resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal transport in compensated semimetals: Effect of electron-electron scattering on Lorenz ratio

It is well known that the electronic thermal conductivity of clean compensated semimetals can be greatly enhanced over the electric conductivity by the availability of an ambipolar mechanism of conduction, whereby electrons and holes flow in the same direction experiencing negligible Coulomb scattering as well as negligible impurity scattering. This enhancement—resulting in a breakdown of the Wiedemann-Franz law with an anomalously large Lorenz ratio—has been recently observed in two-dimensional monolayer and bilayer graphene near the charge neutrality point. In contrast to this, three-dimensional compensated semimetals such as WP 2 and Sb are typically found to show a reduced Lorenz ratio. Here, we investigate the reasons for this difference, focusing on the low-temperature regime where the electron-electron scattering is expected to dominate over other scattering mechanisms. We show that the different regimes of Fermi statistics (nondegenerate electron-hole liquid in graphene versus degenerate electron-hole liquid in compensated semimetals) are not sufficient to explain the reduction of the Lorenz ratio in the latter. We propose that the solution of the puzzle lies in the large separation of electron and hole pockets in momentum space, which allows compensated semimetals to sustain sizable regions of electron-hole accumulation near the contacts. These accumulations suppress the ambipolar conduction mechanism and effectively split the system into two independent electron and hole conductors. We present a quantitative theory of the crossover from ambipolar to unipolar conduction as a function of the size of the electron-hole accumulation regions, and show that it naturally leads to a sample-size-dependent thermal conductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Trace Elemental Analysis of Bulk Thorium Using an Automated Separation–Inductively Coupled Plasma Optical Emission Spectroscopy Methodology

Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma–optical emission spectroscopy (ICP-OES). ICP-OES is a universal approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. Finally, while reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.

47 OTHER INSTRUMENTATION↗

Statistical methods for efficient design of community surveys of response to noise: Random coefficients regression models

Research studies of residents' responses to noise consist of interviews with samples of individuals who are drawn from a number of different compact study areas. The statistical techniques developed provide a basis for those sample design decisions. These techniques are suitable for a wide range of sample survey applications. A sample may consist of a random sample of residents selected from a sample of compact study areas, or in a more complex design, of a sample of residents selected from a sample of larger areas (e.g., cities). The techniques may be applied to estimates of the effects on annoyance of noise level, numbers of noise events, the time-of-day of the events, ambient noise levels, or other factors. Methods are provided for determining, in advance, how accurately these effects can be estimated for different sample sizes and study designs. Using a simple cost function, they also provide for optimum allocation of the sample across the stages of the design for estimating these effects. These techniques are developed via a regression model in which the regression coefficients are assumed to be random, with components of variance associated with the various stages of a multi-stage sample design.

Tomberlin, T. J.↗

Fused Bead Analysis of Diogenite Meteorites

Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from ~10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

Mittlefehldt, D.W.↗

Detection of melting by X-ray imaging at high pressure

The occurrence of partial melting at elevated pressure and temperature is documented in real time through measurement of volume strain induced by a fixed temperature change. Here we present the methodology for measuring volume strains to one part in 10{sup −4} for mm{sup 3} sized samples in situ as a function of time during a step in temperature. By calibrating the system for sample thermal expansion at temperatures lower than the solidus, the onset of melting can be detected when the melting volume increase is of comparable size to the thermal expansion induced volume change. We illustrate this technique with a peridotite sample at 1.5 GPa during partial melting. The Re capsule is imaged with a CCD camera at 20 frames/s. Temperature steps of 100 K induce volume strains that triple with melting. The analysis relies on image comparison for strain determination and the thermal inertia of the sample is clearly seen in the time history of the volume strain. Coupled with a thermodynamic model of the melting, we infer that we identify melting with 2 vol.% melting.

36 MATERIALS SCIENCE↗

Combining Mass Spectrometry of Picoliter Samples with a Multicompartment Electrodynamic Trap for Probing the Chemistry of Droplet Arrays

Single droplet levitation provides contactless access to the microphysical and chemical properties of micrometer-sized samples. Most applications of droplet levitation to chemical and biological systems use nondestructive optical techniques to probe droplet properties. To provide improved chemical specificity, we coupled a multicompartment quadrupole electrodynamic trap (QET) with single droplet mass spectrometry. Our QET continuously traps a monodisperse droplet population (tens to hundreds of droplets) and allows for the simultaneous sizing of a single droplet using its Mie scattering pattern. Single droplets are subsequently ejected into the ionization region of an ambient pressure inlet mass spectrometer. We optimized two complementary soft ionization techniques for picoliter aqueous droplets: (1) paper spray (PS) ionization and (2) thermal desorption glow discharge (TDGD) ionization. Both techniques detect oxygenated organic acids in single droplets, with signal-to-noise ratios >100 and detection limits on the order of 10 pg. Sensitivity and reproducibility across single droplets are driven by the droplet deposition location and spray stability in PS-MS and the ionization region humidity and analyte evaporation rate in TDGD-MS. Importantly, the analyte evaporation rate can control the TDGD-MS quantitative capability because high evaporation rates result in significant ion suppression. Additionally, this effect is mitigated by optimizing the vaporization temperature, droplet size range, and analyte volatility. We demonstrate quantitative and reproducible measurements with a droplet internal standard (<10% RSD) and compare the sensitivity of PS-MS and TDGD-MS. Finally, we demonstrate the application of QET-MS to the study of heterogeneous chemical kinetics with the reaction of gas phase O 3 and aqueous maleic acid droplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A robust calibration of the clumped isotopes to temperature relationship for foraminifers

The clumped isotope (Δ 47 ) proxy is a promising geochemical tool to reconstruct past ocean temperatures far back in time and in unknown settings, due to its unique thermodynamic basis that renders it independent from other environmental factors like seawater composition. Although previously hampered by large sample-size requirements, recent methodological advances have made the paleoceanographic application of Δ 47 on small (<5 mg) foraminifer samples possible. Previous studies show a reasonable match between Δ 47 calibrations based on synthetic carbonate and various species of planktonic foraminifers. However, studies performed before recent methodological advances were based on relatively few species and data treatment that is now outdated. To overcome these limitations and elucidate species-specific effects, we analyzed 14 species of planktonic foraminifers in sediment surface samples from 13 sites, covering a growth temperature range of ~0-28 °C. We selected mixed layer-dwelling and deep-dwelling species from a wide range of ocean settings to evaluate the feasibility of temperature reconstructions for different water depths. Various techniques to estimate foraminifer calcification temperatures were tested in order to assess their effects on the calibration and to find the most suitable approach. Results from this study generally confirm previous findings that there are no species-specific effects on the Δ 47 -temperature relationship in planktonic foraminifers, with one possible exception. Various morphotypes of Globigerinoides ruber were found to often deviate from the general trend determined for planktonic foraminifers. Our data are in excellent agreement with a recent foraminifer calibration study that was performed with a different analytical setup, as well as with a calibration based exclusively on benthic foraminifers. A combined, methodologically homogenized dataset also reveals very good agreement with an inorganic calibration based on travertines. Our findings highlight the potential of the Δ 47 paleothermometer to be applied to recent and extinct species alike to study surface ocean temperatures as well as thermocline variability for a multitude of settings and time scales.

58 GEOSCIENCES↗