Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Ice Mass Fluctuations and Earthquake Hazard

In south central Alaska, tectonic strain rates are high in a region that includes large glaciers undergoing ice wastage over the last 100-150 years [Sauber et al., 2000; Sauber and Molnia, 2004]. In this study we focus on the region referred to as the Yakataga segment of the Pacific-North American plate boundary zone in Alaska. In this region, the Bering and Malaspina glacier ablation zones have average ice elevation decreases from 1-3 meters/year (see summary and references in Molnia, 2005). The elastic response of the solid Earth to this ice mass decrease alone would cause several mm/yr of horizontal motion and uplift rates of up to 10-12 mm/yr. In this same region observed horizontal rates of tectonic deformation range from 10 to 40 mm/yr to the north-northwest and the predicted tectonic uplift rates range from -2 mm/year near the Gulf of Alaska coast to 12mm/year further inland [Savage and Lisowski, 1988; Ma et al, 1990; Sauber et al., 1997, 2000, 2004; Elliot et al., 2005]. The large ice mass changes associated with glacial wastage and surges perturb the tectonic rate of deformation at a variety of temporal and spatial scales. The associated incremental stress change may enhance or inhibit earthquake occurrence. We report recent (seasonal to decadal) ice elevation changes derived from data from NASA's ICESat satellite laser altimeter combined with earlier DEM's as a reference surface to illustrate the characteristics of short-term ice elevation changes [Sauber et al., 2005, Muskett et al., 2005]. Since we are interested in evaluating the effect of ice changes on faulting potential, we calculated the predicted surface displacement changes and incremental stresses over a specified time interval and calculated the change in the fault stability margin using the approach given by Wu and Hasegawa [1996]. Additionally, we explored the possibility that these ice mass fluctuations altered the seismic rate of background seismicity. Although we primarily focus on evaluating the influence of ice mass changes since the end of the little Ice Age, the study is partially motivated by paleoseismic evidence from Yakataga and Kodiak regions which suggests that earlier glacier retreat may be associated with large earthquakes [Sauber et al., 2000; Carver et al., 2003].

Sauber, J.↗

The Distribution of Lightning Channel Lengths in Northern Alabama Thunderstorms

Lightning is well known to be a major source of tropospheric NOx, and in most cases is the dominant natural source (Huntreiser et al 1998, Jourdain and Hauglustaine 2001). Production of NOx by a segment of a lightning channel is a function of channel segment energy density and channel segment altitude. A first estimate of NOx production by a lightning flash can be found by multiplying production per segment [typically 104 J/m; Hill (1979)] by the total length of the flash s channel. The purpose of this study is to determine average channel length for lightning flashes near NALMA in 2008, and to compare average channel length of ground flashes to the average channel length of cloud flashes.

Peterson, H. S.↗

Development and optimization of SPECT gated blood pool cluster analysis for the prediction of CRT outcome

Purpose: Phase analysis of single photon emission computed tomography (SPECT) radionuclide angiography (RNA) has been investigated for its potential to predict the outcome of cardiac resynchronization therapy (CRT). However, phase analysis may be limited in its potential at predicting CRT outcome as valuable information may be lost by assuming that time-activity curves (TAC) follow a simple sinusoidal shape. A new method, cluster analysis, is proposed which directly evaluates the TACs and may lead to a better understanding of dyssynchrony patterns and CRT outcome. Cluster analysis algorithms were developed and optimized to maximize their ability to predict CRT response. Methods: About 49 patients (N = 27 ischemic etiology) received a SPECT RNA scan as well as positron emission tomography (PET) perfusion and viability scans prior to undergoing CRT. A semiautomated algorithm sampled the left ventricle wall to produce 568 TACs from SPECT RNA data. The TACs were then subjected to two different cluster analysis techniques, K-means, and normal average, where several input metrics were also varied to determine the optimal settings for the prediction of CRT outcome. Each TAC was assigned to a cluster group based on the comparison criteria and global and segmental cluster size and scores were used as measures of dyssynchrony and used to predict response to CRT. A repeated random twofold cross-validation technique was used to train and validate the cluster algorithm. Receiver operating characteristic (ROC) analysis was used to calculate the area under the curve (AUC) and compare results to those obtained for SPECT RNA phase analysis and PET scar size analysis methods. Results: Using the normal average cluster analysis approach, the septal wall produced statistically significant results for predicting CRT results in the ischemic population (ROC AUC = 0.73;p < 0.05 vs. equal chance ROC AUC = 0.50) with an optimal operating point of 71% sensitivity and 60% specificity. Cluster analysis results were similar to SPECT RNA phase analysis (ROC AUC = 0.78, p = 0.73 vs cluster AUC; sensitivity/specificity = 59%/89%) and PET scar size analysis (ROC AUC = 0.73, p = 1.0 vs cluster AUC; sensitivity/specificity = 76%/67%). Conclusions: A SPECT RNA cluster analysis algorithm was developed for the prediction of CRT outcome. Cluster analysis results produced results equivalent to those obtained from Fourier and scar analysis.

60 APPLIED LIFE SCIENCES↗

Evaluation of a deformable registration algorithm for subsequent lung computed tomography imaging during radiochemotherapy

Purpose: Rating both a lung segmentation algorithm and a deformable image registration (DIR) algorithm for subsequent lung computed tomography (CT) images by different evaluation techniques. Furthermore, investigating the relative performance and the correlation of the different evaluation techniques to address their potential value in a clinical setting. Methods: Two to seven subsequent CT images (69 in total) of 15 lung cancer patients were acquired prior, during, and after radiochemotherapy. Automated lung segmentations were compared to manually adapted contours. DIR between the first and all following CT images was performed with a fast algorithm specialized for lung tissue registration, requiring the lung segmentation as input. DIR results were evaluated based on landmark distances, lung contour metrics, and vector field inconsistencies in different subvolumes defined by eroding the lung contour. Correlations between the results from the three methods were evaluated. Results: Automated lung contour segmentation was satisfactory in 18 cases (26%), failed in 6 cases (9%), and required manual correction in 45 cases (66%). Initial and corrected contours had large overlap but showed strong local deviations. Landmark-based DIR evaluation revealed high accuracy compared to CT resolution with an average error of 2.9 mm. Contour metrics of deformed contours were largely satisfactory. The median vector length of inconsistency vector fields was 0.9 mm in the lung volume and slightly smaller for the eroded volumes. There was no clear correlation between the three evaluation approaches. Conclusions: Automatic lung segmentation remains challenging but can assist the manual delineation process. Proven by three techniques, the inspected DIR algorithm delivers reliable results for the lung CT data sets acquired at different time points. Clinical application of DIR demands a fast DIR evaluation to identify unacceptable results, for instance, by combining different automated DIR evaluation methods.

60 APPLIED LIFE SCIENCES↗

Magnetic Resonance Imaging Assessment of Spinal Cord and Cauda Equina Motion in Supine Patients With Spinal Metastases Planned for Spine Stereotactic Body Radiation Therapy

Purpose: To assess motion of the spinal cord and cauda equina, which are critical neural tissues (CNT), which is important when evaluating the planning organ-at-risk margin required for stereotactic body radiation therapy. Methods and Materials: We analyzed CNT motion in 65 patients with spinal metastases (11 cervical, 39 thoracic, and 24 lumbar spinal segments) in the supine position using dynamic axial and sagittal magnetic resonance imaging (dMRI, 3T Verio, Siemens) over a 137-second interval. Motion was segregated according to physiologic cardiorespiratory oscillatory motion (characterized by the average root mean square deviation) and random bulk shifts associated with gross patient motion (characterized by the range). Displacement was evaluated in the anteroposterior (AP), lateral (LR), and superior-inferior (SI) directions by use of a correlation coefficient template matching algorithm, with quantification of random motion measure error over 3 separate trials. Statistical significance was defined according to P<.05. Results: In the AP, LR, and SI directions, significant oscillatory motion was observed in 39.2%, 35.1%, and 10.8% of spinal segments, respectively, and significant bulk motions in all cases. The median oscillatory CNT motions in the AP, LR, and SI directions were 0.16 mm, 0.17 mm, and 0.44 mm, respectively, and the maximal statistically significant oscillatory motions were 0.39 mm, 0.41 mm, and 0.77 mm, respectively. The median bulk displacements in the AP, LR, and SI directions were 0.51 mm, 0.59 mm, and 0.66 mm, and the maximal statistically significant displacements were 2.21 mm, 2.87 mm, and 3.90 mm, respectively. In the AP, LR, and SI directions, bulk displacements were greater than 1.5 mm in 5.4%, 9.0%, and 14.9% of spinal segments, respectively. No significant differences in axial motion were observed according to cord level or cauda equina. Conclusions: Oscillatory CNT motion was observed to be relatively minor. Our results support the importance of controlling bulk patient motion and the practice of applying a planning organ-at-risk margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radial feature descriptors for cell classification and recommendation

This paper introduces computational tools for cell classification into normal and abnormal, as well as content-based-image-retrieval (CBIR) for cell recommendation. It also proposes the radial feature descriptors (RFD), which define evenly interspaced segments around the nucleus, and proportional to the convexity of the nuclear boundary. Experiments consider Herlev and CRIC image databases as input to classification via Random Forest and bootstrap; we compare 14 different feature sets by means of False Negative Rate (FNR) and Kappa (κ), obtaining FNR =0.02 and κ=0.89 for Herlev, and FNR =0.14 and κ=0.78 for CRIC. Next, we sort and rank cell images using convolutional neural networks and evaluate performance with the Mean Average Precision (MAP), achieving MAP =0.84 and MAP =0.82 for Herlev and CRIC, respectively. Finally, cell classification show encouraging results regarding RFD, including its sensitivity to intensity variation around the nuclear membrane as it bypasses cytoplasm segmentation.

47 OTHER INSTRUMENTATION↗

Semi-automatic image annotation using 3D LiDAR projections and depth camera data

Efficient image annotation is necessary to utilize deep learning object recognition neural networks in nuclear safeguards, such as for the detection and localization of target objects like nuclear material containers (NMCs). This capability can help automate the inventory accounting of different types of NMCs within nuclear storage facilities. The conventional manual annotation process is labor-intensive and time-consuming, hindering the rapid deployment of deep learning models for NMC identifications. This paper introduces a novel semi-automatic method for annotating 2D images of nuclear material containers (NMCs) by combining 3D light detection and ranging (LiDAR) data with color and depth camera images collected from a handheld scan system. The annotation pipeline involves an operator manually marking new target objects on a LiDAR-generated map, and projecting these 3D locations to images, thereby automatically creating annotations from the projections. The semi-automatic approach significantly reduces manual efforts and the expertise in image annotation that is required to perform the task, allowing deep learning models to be trained on-site within a few hours. The paper compares the performance of models trained on datasets annotated through various methods, including semi-automatic, manual, and commercial annotation services. The evaluation demonstrates that the semi-automatic annotation method achieves comparable or superior results, with a mean average precision (mAP) above 0.9, showcasing its efficiency in training object recognition models. Additionally, the paper explores the application of the proposed method to instance segmentation, achieving promising results in detecting multiple types of NMCs in various formations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

PHASE: Personalized Head-based Automatic Simulation for Electromagnetic properties in 7T MRI

Accurate and individualized human head models are becoming increasingly important for electromagnetic (EM) simulations. These simulations depend on precise anatomical representations to realistically model electric and magnetic field distributions, particularly when evaluating Specific Absorption Rate (SAR) within safety guidelines. State of the art simulations use the Virtual Population due to limited public resources and the impracticality of manually annotating patient data at scale. Here, this paper introduces Personalized Head-based Automatic Simulation for EM properties (PHASE), an automated open-source toolbox that generates high-resolution, patient-specific head models for EM simulations using paired T1-weighted (T1w) magnetic resonance imaging (MRI) and computed tomography (CT) scans with 14 tissue labels. To evaluate the performance of PHASE models, we conduct semi-automated segmentation and EM simulations on 15 real human patients, serving as the gold standard reference. The PHASE model achieved comparable global SAR and localized SAR averaged over 10 grams of tissue (SAR-10g), demonstrating its potential as a promising tool for generating large-scale human model datasets in the future. The code and models of PHASE toolbox have been made publicly available: https://github.com/hrlblab/PHASE.

Deep learning↗

Oceanic Heat Delivery to the Antarctic Continental Shelf: Large-Scale, Low-Frequency Variability

According to the article, onshore penetration of oceanic water across the Antarctic continental slope (ACS) plays a major role in global sea level rise by delivering heat to the Antarctic marginal seas, thus contributing to the basal melting of ice shelves. Here the time-mean (Φ mean ) and eddy (Φ eddy ) components of the heat transport (Φ) across the 1,000-m isobath along the entire ACS are investigated using a 0.1° global coupled ocean/sea ice simulation based on the Los Alamos Parallel Ocean Program (POP) and sea ice (Community Ice CodE) models. In this work, comparison with in situ hydrography shows that the model successfully represents the basic water mass structure, with a warm bias in the Circumpolar Deep Water layer. Segments of on-shelf Φ, with lengths of O(100–1,000 km), are found along the ACS. The circumpolar integral of the annually averaged Φ is O(20 TW), with Φ eddy always on-shelf, while Φ mean fluctuates between on-shelf and off-shelf. Stirring along isoneutral surfaces is often the dominant process by which eddies transport heat across the ACS, but advection of heat by both mean flow-topography interactions and eddies can also be significant depending on the along- and across-slope location. The seasonal and interannual variability of the circumpolarly integrated Φ mean is controlled by convergence of Ekman transport within the ACS. Prominent warming features at the bottom of the continental shelf (consistent with observed temperature trends) are found both during high-Southern Annular Mode and high-Niño 3.4 periods, suggesting that climate modes can modulate the heat transfer from the Southern Ocean to the ACS across the entire Antarctic margin.

54 ENVIRONMENTAL SCIENCES↗

Stochastic parametric skeletal dosimetry model for humans: Pediatric and adult computational skeleton phantoms for internal bone marrow dosimetry

Currently, computational phantoms that simulate skeletal tissues are used in active red bone marrow (AM) internal dosimetry. Up-to-date reference computational phantoms recommended by the ICRP are based on the analysis of CT-images of cadavers. Such phantoms have significant disadvantages. One disadvantage is that the assessment of uncertainty due to the population variability of skeleton dimensions and microstructure results from the limited availability of autopsy material. Another disadvantage is the simplified modelling of cortical layer and bone microarchitecture. A method of stochastic parametric skeletal dosimetry modelling of the bone structures – SPSD modelling – has been developed as an alternative to the ICRP reference phantoms. In the framework of this approach, skeletal phantom parameters are evaluated based on extensively reviewed results of published measurements of real bones. The SPSD approach allows for the assessment of both population-average values and their variability. SPSD-phantoms of the skeleton are modelled in voxel representation. They consist of smaller phantoms of the bone sites – segments – described by simple geometric shapes with uniform microarchitecture parameters. Such segmentation makes it possible to account for non-homogeneous skeletal microarchitecture and to model the bone structure with the required voxel resolution to elaborate suitable skeletal phantoms. The current study presents the parameters of the SPSD skeletal phantoms for the following age-groups: newborn, 1-year-old, 5-year-old, 10-year-old, 15-year-old (male and female), and adult (male and female). This skeletal phantom can be used for dosimetry as an alternative to available reference phantoms for bone-seeking radionuclides. The above-mentioned age- and sex-specific skeletal phantoms are comprised of 289 unique segments. The characteristics of the SPSD phantoms do not contradict published data and are in good agreement with the measurement results of real bones.

Science & Technology - Other Topics↗

Mapping and Monitoring Delmarva Fox Squirrel Habitat Using an Airborne LiDAR Profiler

Twenty five hundred thirty nine kilometers of airborne laser profiling and videography data were acquired over the state of Delaware during the summer of 2000. The laser ranging measurements and video from approximately one-half of that data set (1304 km) were analyzed to identify and locate forested sites that might potentially support populations of Delmarva fox squirrel (DFS, Sciurus niger cinereus). The DFS is an endangered species previously endemic to tall, dense, mature forests with open understories on the Eastern Shore of the Chesapeake Bay. The airborne LiDAR employed in this study can measure forest canopy height and canopy closure, but cannot measure or infer understory canopy conditions. Hence the LiDAR must be viewed as a tool to map potential, not actual, habitat. Fifty-three potentially suitable DFS sites were identified in the 1304 km of flight transect data. Each of the 53 sites met the following criteria according to the LiDAR and video record: (1 ) at least 120m of contiguous forest; (2) an average canopy height greater than 20m; (3) an average canopy closure of >80%; and (4) no roofs, impervious surface (e.g., asphalt, concrete), and/or open water anywhere along the 120m length of the laser segment. Thirty-two of the 53 sites were visited on the ground and measurements taken for a DFS habitat suitability model. Seventy eight percent of the sites (25 of 32) were judged by the model to be suited to supporting a DFS population. Twenty-eight of the 32 sites visited in the field were in forest cover types (hardwood, mixed wood, conifer, wetlands) according to a land cover GIS map. Of these, 23 (82%) were suited to support DFS. The remaining 4 sites were located in nonforest cover types - agricultural or residential areas. Two of the four, or 50% were suited to the DFS. All of the LiDAR flight data, 2539 km, were analyzed to

Nelson, Ross↗

The Degradational History of Endeavour Crater, Mars

Endeavour crater (2.28 deg S, 354.77 deg E) is a Noachian-aged 22 km-diameter impact structure of complex morphology in Meridiani Planum. The degradation state of the crater has been studied using Mars Reconnaissance Orbiter and Opportunity rover data. Exposed rim segments rise approximately 10 m to approximately 100 m above the level of the embaying Burns Formation and the crater is 200-500 m deep with the southern interior wall exposing over approximately 300 m relief. Both pre-impact rocks (Matijevic Formation) and Endeavour impact ejecta (Shoemaker Formation) are present at Cape York, but only the Shoemaker crops out (up to approximately 140 m) along the rim segment from Murray Ridge to Cape Tribulation. Study of pristine complex craters Bopolu and Tooting, and morphometry of other martian complex craters, enables us to approximate Endeavour's pristine form. The original rim likely averaged 410 m (+/-)200 m in elevation and a 250-275 m section of ejecta ((+/-)50-60 m) would have composed a significant fraction of the rim height. The original crater depth was likely between 1.5 km and 2.2 km. Comparison between the predicted original and current form of Endeavour suggests approximately 100-200 m rim lowering that removed most ejecta in some locales (e.g., Cape York) while thick sections remain elsewhere (e.g., Cape Tribulation). Almost complete removal of ejecta at Cape York and minimal observable offset across fractures indicates current differences in rim relief are not solely due to original rim relief. Rim segments are embayed by approximately 100-200 m thickness of plains rocks outside the crater, but thicker deposits lie inside the crater. Ventifact textures confirm ongoing eolian erosion with the overall extent difficult to estimate. Analogy with degraded Noachian-aged craters south of Endeavour, however, suggests fluvial erosion dominated rim degradation in the Noachian and was likely followed by approximately 10s of meters modification by alternate processes. Such degradation is consistent with 1) the interpretation of a pediment on the rim flanks of Endeavour, 2) the formation of features such as Marathon Valley, 3) the nearly complete removal of ejecta at Cape York, 4) preservation of a thicker section of ejecta at Cape Tribulation and perhaps, 5) the origin of some gaps in the rim around the crater. A paucity of debris shed from the rim indicates most degradation occurred prior to embayment by the plains rocks.

Grant, J. A.↗

A region-appearance-based adaptive variational model for 3D liver segmentation

Purpose: Liver segmentation from computed tomography images is a challenging task owing to pixel intensity overlapping, ambiguous edges, and complex backgrounds. The authors address this problem with a novel active surface scheme, which minimizes an energy functional combining both edge- and region-based information. Methods: In this semiautomatic method, the evolving surface is principally attracted to strong edges but is facilitated by the region-based information where edge information is missing. As avoiding oversegmentation is the primary challenge, the authors take into account multiple features and appearance context information. Discriminative cues, such as multilayer consecutiveness and local organ deformation are also implicitly incorporated. Case-specific intensity and appearance constraints are included to cope with the typically large appearance variations over multiple images. Spatially adaptive balancing weights are employed to handle the nonuniformity of image features. Results: Comparisons and validations on difficult cases showed that the authors’ model can effectively discriminate the liver from adhering background tissues. Boundaries weak in gradient or with no local evidence (e.g., small edge gaps or parts with similar intensity to the background) were delineated without additional user constraint. With an average surface distance of 0.9 mm and an average volume overlap of 93.9% on the MICCAI data set, the authors’ model outperformed most state-of-the-art methods. Validations on eight volumes with different initial conditions had segmentation score variances mostly less than unity. Conclusions: The proposed model can efficiently delineate ambiguous liver edges from complex tissue backgrounds with reproducibility. Quantitative validations and comparative results demonstrate the accuracy and efficacy of the model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-87: Automated Liver Segmentation Method for CBCT Dataset by Combining Sparse Shape Composition and Probabilistic Atlas Construction

Purpose: The aiming of this study was to extract liver structures for daily Cone beam CT (CBCT) images automatically. Methods: Datasets were collected from 50 intravenous contrast planning CT images, which were regarded as training dataset for probabilistic atlas and shape prior model construction. Firstly, probabilistic atlas and shape prior model based on sparse shape composition (SSC) were constructed by iterative deformable registration. Secondly, the artifacts and noise were removed from the daily CBCT image by an edge-preserving filtering using total variation with L1 norm (TV-L1). Furthermore, the initial liver region was obtained by registering the incoming CBCT image with the atlas utilizing edge-preserving deformable registration with multi-scale strategy, and then the initial liver region was converted to surface meshing which was registered with the shape model where the major variation of specific patient was modeled by sparse vectors. At the last stage, the shape and intensity information were incorporated into joint probabilistic model, and finally the liver structure was extracted by maximum a posteriori segmentation.Regarding the construction process, firstly the manually segmented contours were converted into meshes, and then arbitrary patient data was chosen as reference image to register with the rest of training datasets by deformable registration algorithm for constructing probabilistic atlas and prior shape model. To improve the efficiency of proposed method, the initial probabilistic atlas was used as reference image to register with other patient data for iterative construction for removing bias caused by arbitrary selection. Results: The experiment validated the accuracy of the segmentation results quantitatively by comparing with the manually ones. The volumetric overlap percentage between the automatically generated liver contours and the ground truth were on an average 88%–95% for CBCT images. Conclusion: The experiment demonstrated that liver structures of CBCT with artifacts can be extracted accurately for following adaptive radiation therapy. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

60 APPLIED LIFE SCIENCES↗

SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

XV-15 Tiltrotor Low Noise Approach Operations

Acoustic data have been acquired for the XV- 15 tiltrotor aircraft performing approach operations for a variety of different approach profile configurations. This flight test program was conducted jointly by NASA, the U.S. Army, and Bell Helicopter Textron, Inc. (BHTI) in June 1997. The XV-15 was flown over a large area microphone array, which was deployed to directly measure the noise footprint produced during actual approach operations, The XV- 15 flew realistic approach profiles that culminated in IGE hover over a landing pad. Aircraft tracking and pilot guidance was provided by a Differential Global Positioning System (DGPS) and a flight director system developed at BHTT. Approach profile designs emphasized noise reduction while maintaining handling qualities sufficient for tiltrotor commercial passenger ride comfort and flight safety under Instrument Flight Rules (IFR) conditions. A discussion of the approach profile design philosophy is provided. Five different approach profiles are discussed in detail -- 3deg., 6 deg., and 9 deg. approaches, and two very different 3 deg. to 9 deg. segmented approaches. The approach profile characteristics are discussed in details, followed by the noise footprints and handling qualities. Sound exposure levels are also presented on an averaged basis and as a function of the sideline distance for a number of up-range distances from the landing point. A comparison of the noise contour areas is also provided. The results document the variation in tiltrotor noise due to changes in operating condition, and indicate the potential for significant noise reduction using the unique tiltrotor capability of nacelle tilt.

Conner, David↗

XV-15 Tiltrotor Low Noise Approach Operations

Acoustic data have been acquired for the XV-15 tiltrotor aircraft performing approach operations for a variety of different approach profile configurations. This flight test program was conducted jointly by NASA, the U.S. Army, and Bell Helicopter Textron, Inc. (BHTI) in June 1997. The XV-15 was flown over a large area microphone array, which was deployed to directly measure the noise footprint produced during actual approach operations. The XV-15 flew realistic approach profiles that culminated in IGE hover over a landing pad. Aircraft tracking and pilot guidance was provided by a Differential Global Positioning System (DGPS) and a flight director system developed at BHTI. Approach profile designs emphasized noise reduction while maintaining handling qualities sufficient for tiltrotor commercial passenger ride comfort and flight safety under Instrument Flight Rules (IFR) conditions. A discussion of the approach profile design philosophy is provided. Five different approach profiles are discussed in detail -- 3 deg., 6 deg., and 9 deg. approaches, and two very different 3 deg. to 9 deg. segmented approaches. The approach profile characteristics are discussed in detail, followed by the noise footprints and handling qualities. Sound exposure levels are also presented on an averaged basis and as a function of the sideline distance for a number of up-range distances from the landing point. A comparison of the noise contour areas is also provided. The results document the variation in tiltrotor noise due to changes in operating condition, and indicate the potential for significant noise reduction using the unique tiltrotor capability of nacelle tilt.

Conner, David A.↗