Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Non-destructive observation of intact bacteria and viruses in water by the highly sensitive frequency transmission electric-field method based on SEM

Highlights: • We developed a high-sensitive frequency transmission electric-field (FTE) system. • The output signal was highly enhanced by applying voltage to a metal layer on SiN. • The spatial resolution of new FTE method is 41 nm. • New FTE system enables observation of the intact bacteria and virus in water. - Abstract: The high-resolution structural analysis of biological specimens by scanning electron microscopy (SEM) presents several advantages. Until now, wet bacterial specimens have been examined using atmospheric sample holders. However, images of unstained specimens in water using these holders exhibit very poor contrast and heavy radiation damage. Recently, we developed the frequency transmission electric-field (FTE) method, which facilitates the SEM observation of biological specimens in water without radiation damage. However, the signal detection system presents low sensitivity. Therefore, a high EB current is required to generate clear images, and thus reducing spatial resolution and inducing thermal damage to the samples. Here a high-sensitivity detection system is developed for the FTE method, which enhances the output signal amplitude by hundredfold. The detection signal was highly enhanced when voltage was applied to the metal layer on silicon nitride thin film. This enhancement reduced the EB current and improved the spatial resolution as well as the signal-to-noise ratio. The spatial resolution of a high-sensitive FTE system is 41 nm, which is considerably higher than previous FTE system. New FTE system can easily be utilised to examine various unstained biological specimens in water, such as living bacteria and viruses.

60 APPLIED LIFE SCIENCES↗

Photodynamic action of curcumin derived polymer modified ZnO nanocomposites

Highlights: ► ZnO/PVA nano sensitized with curcumin and its metal complex were synthesized by vacuum evaporation method. ► M/cur sensitized on ZnO/PVA nanocomposites were characterized. ► Generation of {sup 1}O{sub 2} and ROS were detected by optical and EPR-spin trapping method. ► It was found that photoinduced cleavage of DNA using Zn/cur–ZnO/PVA was superior. ► Photodegradation of MB in water catalyzed by ZnO/PVA–Zn/cur was also superior under visible light. -- Abstract: The photodynamic action of ZnO nano can be improved by modifying the surface by PVA and encapsulating the natural product, curcumin. The synthesized ZnO/PVA nanocomposites have been characterized using XRD, SEM, TEM, FTIR, TG–DTA, etc. Here we are reporting the photodynamic effect of ZnO nanocomposites on pUC18 DNA. Based on optical and EPR measurements, singlet oxygen and other ROS were responsible for photocleavage of DNA. Most importantly, derived curcumin modified ZnO/PVA nanocomposites were comparatively more effective than derived curcumin complex against HeLa cell lines under in vitro condition. In addition, photodegradation of methylene blue (MB) in water catalyzed by nano ZnO/PVA–curcumin derivative was investigated at room temperature. Under visible irradiation photocatalytic activity of ZnO nanomaterial sensitized curcumin was higher than those of curcumin and nano ZnO.

36 MATERIALS SCIENCE↗

Draft SOP for Sample Matching using ICP-MS

The purpose of this standard operating procedure (SOP) is to provide an assay for testing the hypothesis that two samples are from the same sub-population, which can mean they came from the same batch, set of replicate batches, or the same process. The outcome is a likelihood ratio, which should be used in combination with prior odds to determine the posterior odds of the two samples coming from the same sub-population. Note that the term “match” is not used because it is imprecise in the context of determining the relationship between two samples. Under this SOP, inductively coupled plasma mass spectrometer (ICP-MS) is used to generate elemental composition data, which is used to test the hypothesis that two samples come from the same sub-population. ICP-MS is a highly sensitive bulk analysis method. The quantity of sample required is ultimately determined by the instrumentation used and the elements selected for generating ROC curves. This SOP specifies that greater than 5 mg of sample be used to enable accurate weights to be obtained for the sample in tared 3 mL Teflon vials. However, we have conducted preliminary assays with our instrumentation that suggest that sample quantity can be reduced to 50 micrograms if elemental abundances are normalized to total metal content (see Step 10). We use ICP-MS because it is the most sensitive method for determining the concentration of the largest number of elements. Other elemental analysis methods could be used to generate data for this test (e.g., ICP-OES), but specific tests would be necessary to work out the SOP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel method to control explosive shock sensitivity: Formulations, experiments and modeling

The microstructure of a heterogeneous high explosive (HE) affects its shock initiation sensitivity and detonation performance. Alteration of the void content and/or void structure (i.e., bulk heating or mechanical damage) therefore changes the shock initiation behavior. Controlling and predicting the change in shock sensitivity after an HE has undergone microstructural changes addresses an important and challenging goal for the design and understanding of novel energetic material formulations. In this study, we aimed to develop HE systems to precisely tune shock sensitivity by a thermal treatment prior to use. Specifically, we incorporated a small fraction (1 wt% or less) of thermally expandable microspheres (TEMs) during the formulation process of various plastic-bonded explosives (PBX). TEMs typically consist of a thermoplastic acrylonitrile shell (10-50 µm diameter), which encapsulates an inert low boiling hydrocarbon. Upon heating, the TEMs expand as the shell softens while the hydrocarbon gasifies, increasing the internal pressure and expanding the particle by as much as 120 vol% (irreversibly). Here, we present our progress on shock sensitivity comparisons of HE formulations doped with TEMs after heating and expansion. Experiments, using Composition C-4 thermally cycled to 120°C, showed an increase in shock sensitivity. Additionally, mesoscale modeling revealed that the TEM itself does not act as a hotspot, but instead has a secondary effect on the response of nearby voids. We conclude that TEMs indeed do provide a method to tune shock sensitivity. Further, our results emphasize the non-uniformity of shock waves at the mesoscale, and that upstream defects influence the reactivity of downstream defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Micro-architected material design for mechanical response

Rapid advances in additive manufacturing (AM) have enabled the creation of micro-architected materials—also known as mechanical metamaterials—with unprecedented control over fine-scale geometries and arrangements of multiple material constituents. These “materials” can achieve unique and extraordinary effective mechanical properties through their complex architectures rather than composition alone. A key challenge is to design for these bespoke effective mechanical responses within the constraints of available AM techniques (i.e., given a set of desired effective properties), identify a (often nonunique) micro-architecture and selection of material constituents that achieves them. Two main strategies have emerged. Gradient-based methods use sensitivity analysis to iteratively refine candidate designs, while data-driven methods learn micro-architecture-constituent relationships from existing examples to propose new designs. This article reviews these design approaches for micro-architected materials with tailored mechanical responses that can be fabricated by AM as well as their applications.

Spadaccini, Christopher M [Lawrence Livermore Nati↗

Monte Carlo Perturbation Theory Estimates of Sensitivities to System Dimensions

Here, Monte Carlo methods are developed using adjoint-based perturbation theory and the differential operator method to compute the sensitivities of the k-eigenvalue, linear functions of the flux (reaction rates), and bilinear functions of the forward and adjoint flux (kinetics parameters) to system dimensions for uniform expansions or contractions. The calculation of sensitivities to system dimensions requires computing scattering and fission sources at material interfaces using collisions occurring at the interface—which is a set of events with infinitesimal probability. Kernel density estimators are used to estimate the source at interfaces using collisions occurring near the interface. The methods for computing sensitivities of linear and bilinear ratios are derived using the differential operator method and adjoint-based perturbation theory and are shown to be equivalent to methods previously developed using a collision history–based approach. The methods for determining sensitivities to system dimensions are tested on a series of fast, intermediate, and thermal critical benchmarks as well as a pressurized water reactor benchmark problem with iterated fission probability used for adjoint-weighting. The estimators are shown to agree within 5% and 3σ of reference solutions obtained using direct perturbations with central differences for the majority of test problems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proof-of-Concept Study for Uncertainty Quantification and Sensitivity Analysis using the BRL Shaped-Charge Example

These are the slides for a graduate presentation at Mississippi State University. It covers the following: the BRL Shaped-Charge Geometry in PAGOSA, mesh refinement study, surrogate modeling using a radial basis function network (RBFN), ruling out parameters using sensitivity analysis (equation of state study), uncertainty quantification (UQ) methodology, and sensitivity analysis (SA) methodology. In summary, a mesh convergence study was used to ensure that solutions were numerically stable by comparing PDV data between simulations. A Design of Experiments (DOE) method was used to reduce the simulation space to study the effects of the Jones-Wilkins-Lee (JWL) Parameters for the Composition B main charge. Uncertainty was quantified by computing the 95% data range about the median of simulation output using a brute force Monte Carlo (MC) random sampling method. Parameter sensitivities were quantified using the Fourier Amplitude Sensitivity Test (FAST) spectral analysis method where it was determined that detonation velocity, initial density, C1, and B1 controlled jet tip velocity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

NMR-based serum metabolomics study reveals a innovative diagnostic model for missed abortion

A missed abortion (MA) is an in-utero death of the embryo or fetus before the 20th week of gestation with retained products of conception. In order to discover novel biomarkers for MA, a {sup 1}H NMR spectroscopy-based metabolomics approach was applied to detect human MA serum metabolic profiles. Serum samples were obtained from patients with MA (n = 15) and healthy controls (n = 9) for study. The NOESYPR1D spectrum combined with multi-variate pattern recognition analysis was used to cluster the groups and establish a disease-specific metabolites phenotype. Principal component analysis (PCA) and orthogonal partial least-squares discriminant analysis (OPLS-DA) models were capable of distinguishing MA patients from healthy subjects. The results revealed that 24 metabolites altered in MA patients compared with the control population. Metabolomic pathway analysis demonstrated that alanine, aspartate and glutamate metabolism, citrate cycle (TCA cycle), taurine and hypotaurine metabolism were significantly altered in MA. The results indicated that serum NMR-based metabolomic profiling method is sensitive and specific enough to distinguish MA and from healthy controls, this method could be developed as a clinically useful diagnostic tool for MA. The finding from the MA serum metabolic profiling shed a new light on further understanding of MA disease mechanisms.

60 APPLIED LIFE SCIENCES↗

Adjoint-based sensitivity analysis for high-energy density radiative transfer using flux-limited diffusion

Uncertainty quantification and sensitivity analyses are a vital component for predictive modeling in the sciences and engineering. The adjoint approach to sensitivity analysis requires solving a primary system of equations and a mathematically related set of adjoint equations. The information contained in the equations can be combined to produce sensitivity information in a computationally efficient manner. Here in this work, sensitivity analyses are performed on systems described by flux-limited radiative diffusion using the adjoint approach. The sensitivities computed are shown to agree with standard perturbation theory and require significantly less computational time. The adjoint approach saves the computational cost of one forward solve per sensitivity, making the method attractive when multiple sensitivities are of interest.

42 ENGINEERING↗

Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging

In single photon emission computed tomography, the choice of the collimator has a major impact on the sensitivity and resolution of the system. Traditional parallel-hole and fan-beam collimators used in clinical practice, for example, have a relatively poor sensitivity and subcentimeter spatial resolution, while in small-animal imaging, pinhole collimators are used to obtain submillimeter resolution and multiple pinholes are often combined to increase sensitivity. This paper reviews methods for production, sensitivity maximization, and task-based optimization of collimation for both clinical and preclinical imaging applications. New opportunities for improved collimation are now arising primarily because of (i) new collimator-production techniques and (ii) detectors with improved intrinsic spatial resolution that have recently become available. These new technologies are expected to impact the design of collimators in the future. The authors also discuss concepts like septal penetration, high-resolution applications, multiplexing, sampling completeness, and adaptive systems, and the authors conclude with an example of an optimization study for a parallel-hole, fan-beam, cone-beam, and multiple-pinhole collimator for different applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity-based Experiment Design Optimization for a Molybdenum Critical Experiment

A lack of intermediate molybdenum benchmarks in the ICSBEP has been identified by LANL, Y-12, and IRSN. This lacking adversely effects criticality safety operations and leaves new differential molybdenum data unvalidated. NCERC is proposing a series of intermediate integral experiments to better the understanding of molybdenum systems. Using MCNP6.2 with the ENDF/B-VIII.0 nuclear data library a single unmoderated and four moderated system designs were identified using a sensitivity optimization method. Each proposed system was found to be at least twice as sensitive to the 95 Mo capture cross section in the URR as the sole existing intermediate molybdenum benchmark in the ISCBEP handbook. The addition of a new molybdenum sensitive intermediate system would improve future nuclear data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity Analysis Comparisons on Geologic Case Studies: An International Collaboration, Volume 2

Over the past six years, an informal working group has developed to investigate existing sensitivity analysis methods, examine new methods, and identify best practices. The focus is on the use of sensitivity analysis in case studies involving geologic disposal of spent nuclear fuel or nuclear waste. Three additional case studies are presented in this Volume 2 report, including more nonlinear behavior, outputs which exhibit bifurcation, regime changes, and nested sampling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a testing method for asbestos fibers in treated materials of asbestos containing wastes by transmission electron microscopy

Highlights: • A high sensitive and selective testing method for asbestos in treated materials of asbestos containing wastes was developed. • Asbestos can be determined at a limits are a few million fibers per gram and a few μg g{sup −1}. • High temperature melting treatment samples were determined by this method. Asbestos fiber concentration were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup 6} g{sup −1}. - Abstract: Appropriate treatment of asbestos-containing wastes is a significant problem. In Japan, the inertization of asbestos-containing wastes based on new treatment processes approved by the Minister of the Environment is promoted. A highly sensitive method for testing asbestos fibers in inertized materials is required so that these processes can be approved. We developed a method in which fibers from milled treated materials are extracted in water by shaking, and are counted and identified by transmission electron microscopy. Evaluation of this method by using asbestos standards and simulated slag samples confirmed that the quantitation limits are a few million fibers per gram and a few μg/g in a sample of 50 mg per filter. We used this method to assay asbestos fibers in slag samples produced by high-temperature melting of asbestos-containing wastes. Fiber concentrations were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup −6} f/g. Because the evaluation of treated materials by TEM is difficult owing to the limited amount of sample observable, this testing method should be used in conjunction with bulk analytical methods for sure evaluation of treated materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dakota uncertainty quantification methods applied to the NEK-5000 SAHEX model.

This report summarizes the results of a NEAMS project focused on the use of uncertainty and sensitivity analysis methods within the NEK-5000 and Dakota software framework for assessing failure probabilities as part of probabilistic risk assessment. NEK-5000 is a software tool under development at Argonne National Laboratory to perform computational fluid dynamics calculations for applications such as thermohydraulics of nuclear reactor cores. Dakota is a software tool developed at Sandia National Laboratories containing optimization, sensitivity analysis, and uncertainty quantification algorithms. The goal of this work is to demonstrate the use of uncertainty quantification methods in Dakota with NEK-5000.

Weirs, V. Gregory↗

Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. In addition, an efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

36 MATERIALS SCIENCE↗

Sensitivity Analysis of MFiX-PIC Parameters Using Nodeworks, PSUADE, and DAKOTA

The study presented in this report was aimed to demonstrate UQ analysis performed not only with Nodeworks, but also two other well-established UQ software tools from the U.S. DOE’s National Laboratories (PSUADE from Lawrence Livermore National Laboratory and DAKOTA from Sandia National Laboratory). It is important to emphasize that the motivation of this study was not to determine the best UQ software, but to verify if the global sensitivity analyses from the end-to-end workflow in Nodeworks are consistent with the results of other two UQ software. The components of Nodeworks from Python’s ecosystem have been tested as standalone libraries. However, an assessment study for the complete workflow targeting a specific UQ analysis has not been performed for Nodeworks. Hence, this study is expected to serve as an equivalent of solution verification for Nodeworks using other established UQ tools as reference solution. For this purpose, three distinct flow configurations (i.e., settling bed, bubbling fluidized, and circulating fluidized bed) have been used as representative multiphase flow problems of interest. The results of the systematic simulation campaigns performed in an earlier study using the particle-in-cell (PIC) approach in the Multiphase Flow with Interphase eXchanges (MFIX) suite of solvers (i.e., MFiX-PIC) was utilized. The same set of tabulated results was provided as input to the different UQ software for global sensitivity analysis. Results for the three cases indicate that based on the Sobol’ Sensitivity Indices method the order of importance ranking determined by Nodeworks for the Sobol’ Total Sensitivity Indices is consistent with PSUADE and DAKOTA in each case for the five model parameters considered. The input files for Nodeworks for the three cases are also shared through NETL’s Gitlab repository for the reader interested in reproducibility and further analysis (See Section 1.2).

97 MATHEMATICS AND COMPUTING↗

Geophysical Monitoring Methods Evaluation for the FutureGen 2.0 Project

A comprehensive monitoring program will be needed in order to assess the effectiveness of carbon sequestration at the FutureGen 2.0 carbon capture and storage (CCS) field-site. Geophysical monitoring methods are sensitive to subsurface changes that result from injection of CO 2 and will be used for: (1) tracking the spatial extent of the free phase CO 2 plume, (2) monitoring advancement of the pressure front, (3) identifying or mapping areas where induced seismicity occurs, and (4) identifying and mapping regions of increased risk for brine or CO 2 leakage from the reservoir. Site-specific suitability and cost effectiveness were evaluated for a number of geophysical monitoring methods including: passive seismic monitoring, reflection seismic imaging, integrated surface deformation, time-lapse gravity, pulsed neutron capture logging, cross-borehole seismic, electrical resistivity tomography, magnetotellurics and controlled source electromagnetics. The results of this evaluation indicate that CO 2 injection monitoring using reflection seismic methods would likely be difficult at the FutureGen 2.0 site. Electrical methods also exhibited low sensitivity to the expected CO 2 saturation changes and would be affected by metallic infrastructure at the field site. Passive seismic, integrated surface deformation, time-lapse gravity, and pulsed neutron capture monitoring were selected for implementation as part of the FutureGen 2.0 storage site monitoring program.

54 ENVIRONMENTAL SCIENCES↗