Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Wireless Interrogation of High Temperature Surface Acoustic Wave Dynamic Strain Sensor

Dynamic strain sensing is necessary for high-temperature harsh-environment applications, including powerplants, oil wells, aerospace, and metal manufacturing. Monitoring dynamic strain is important for structural health monitoring and condition-based maintenance in order to guarantee safety, increase process efficiency, and reduce operation and maintenance costs. Sensing in high-temperature (HT), harsh-environments (HE) comes with challenges including mounting and packaging, sensor stability, and data acquisition and processing. Wireless sensor operation at HT is desirable because it reduces the complexity of the sensor connection, increases reliability, and reduces costs. Surface acoustic wave resonators (SAWRs) are compact, can operate wirelessly and battery-free, and have been shown to operate above 1000°C, making them a potential option for HT HE dynamic strain sensing. This paper presents wirelessly interrogated SAWR dynamic strain sensors operating around 288.8MHz at room temperature and tested up to 400°C. The SAWRs were calibrated with a high-temperature wired commercial strain gauge. The sensors were mounted onto a tapered-type Inconel constant stress beam and the assembly was tested inside a box furnace. The SAWR sensitivity to dynamic strain excitation at 25°C, 100°C, and 400°C was .439 μV/με, 0.363μV/με, and .136 μV/με, respectively. Furthermore, the experimental outcomes verified that inductive coupled wirelessly interrogated SAWRs can be successfully used for dynamic strain sensing up to 400°C.

47 OTHER INSTRUMENTATION↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Sensor Incipient Fault Impacts on Building Energy Performance: A Case Study on a Multi-Zone Commercial Building

Existing studies show sensor faults/error could double building energy consumption and carbon emissions compared with the baseline. Those studies assume that the sensor error is fixed or constant. However, sensor faults are incipient in real conditions and there were extremely limited studies investigating the incipient sensor fault impacts systematically. This study filled in this research gap by studying time-developing sensor fault impacts to rule-based controls on a 10-zone office building. The control sequences for variable air volume boxes (VAV) with an air handling unit (AHU) system were selected based on ASHRAE Guideline 36-2018: High-Performance Sequences of Operation for HVAC Systems. Large-scale simulations on cloud were conducted (3600 cases) through stochastic approach. Results show (1) The site energy differences could go –3.3% lower or 18.1% higher, compared with baseline. (2) The heating energy differences could go –66.5% lower or 314.4% higher, compared with baseline. (3) The cooling energy differences could go –11.5% lower or 65.0% higher, compared with baseline. (4) The fan energy differences could go 0.15% lower or 6.9% higher, compared with baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Passive Ceramic Sensor for Far-Field Temperature Measurement at High Temperatures

A passive wireless high-temperature sensor for far-field applications was developed for stable temperature sensing up to 1000 °C. The goal is to leverage the properties of electroceramic materials, including adequate electrical conductivity, high-temperature resilience, and chemical stability in harsh environments. Initial sensors were fabricated using Ag for operation to 600 °C to achieve a baseline understanding of temperature sensing principles using patch antenna designs. Fabrication then followed with higher temperature sensors made from (In, Sn) O2 (ITO) for evaluation up to 1000 °C. A patch antenna was modeled in ANSYS HFSS to operate in a high-frequency region (2.5–3.5 GHz) within a 50 × 50 mm2 confined geometric area using characteristic material properties. The sensor was fabricated on Al2O3 using screen printing methods and then sintered at 700 °C for Ag and 1200 °C for ITO in an ambient atmosphere. Sensors were evaluated at 600 °C for Ag and 1000 °C for ITO and analyzed at set interrogating distances up to 0.75 m using ultra-wideband slot antennas to collect scattering parameters. The sensitivity (average change in resonant frequency with respect to temperature) from 50 to 1000 °C was between 22 and 62 kHz/°C which decreased as interrogating distances reached 0.75 m.

47 OTHER INSTRUMENTATION↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Surface-Mediated Interconnections of Nanoparticles in Cellulosic Fibrous Materials toward 3D Sensors

Fibrous materials serve as an intriguing class of 3D materials to meet the growing demands for flexible, foldable, biocompatible, biodegradable, dis- posable, inexpensive, and wearable sensors and the rising desires for higher sensitivity, greater miniaturization, lower cost, and better wearability. The use of such materials for the creation of a fibrous sensor substrate that interfaces with a sensing film in 3D with the transducing electronics is however difficult by conventional photolithographic methods. Here, a highly effective pathway featuring surface-mediated interconnection (SMI) of metal nanoclusters (NCs) and nanoparticles (NPs) in fibrous materials at ambient conditions is demon- strated for fabricating fibrous sensor substrates or platforms. Bimodally distrib- uted gold–copper alloy NCs and NPs are used as a model system to demonstrate the semiconductive-to-metallic conductivity transition, quantized capacitive charging, and anisotropic conductivity characteristics. Upon coupling SMI of NCs/NPs as electrically conductive microelectrodes and surface-mediated assembly (SMA) of the NCs/NPs as chemically sensitive interfaces, the resulting fibrous chemiresistors function as sensitive and selective sensors for gaseous and vaporous analytes. Finally, this new SMI–SMA strategy has significant implications for manufacturing high-performance fibrous platforms to meet the growing demands of the advanced multifunctional sensors and biosensors.

36 MATERIALS SCIENCE↗

Graphene oxide coated side polished surface plasmon resonance optical fibre sensor with varying polishing losses

Four batches of side-polished SMF optical fibres with different polishing losses, − 0.5 dBm, − 5 dBm, − 10 dBm and − 15 dBm were coated with a graphene oxide layer of ~ 0.5 μm via drop casting. TE polarized light was propagated through the light during experiments and four different transformer oils with different water contents were dropped onto the sensor. The drop in the power of transmitted light was recorded. The responses of the sensors showed good linearity for all, but the least polished fibre showed the weakest response in terms of power drop towards change in concentration. The − 5 dBm fibre showed the best response per unit concentration change. Additional tests showed the increased response for a GO coated side polished sensor compared to an uncoated side polished sensor. Simulation using COMSOL was performed to show the effects on the electric field of a sensor with and without GO coating. Another set of simulations were performed to show the effects of reducing cladding thickness on the coupling of the electric field. Simulations show that the optimal cladding thickness is not the most polished fibre, coinciding with our results that − 15 dBm loss fibre did not show the most response per unit change in the analyte.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ethanol Monitoring Gas Sensor Based on Flower-Shaped Copper Sulfide by a Facile Hydrothermal Method for Marine Transportation

Flower-shaped CuS as a p-type gas-sensing material was synthesized by a facile hydrothermal method in this study. Morphology, structure, and chemical composition of the synthesized CuS gas-sensing material were analyzed by SEM, XRD, XPS, and N{sub 2} adsorption adsorption–desorption technique. Gas-sensing properties of the as-prepared CuS sensors were also investigated toward ethanol monitoring. The results showed that the flower-like CuS nanostructures consisted of interconnected nanosheets and exhibited good crystallinity. With the increase in ethanol concentration, the sensitivity of the CuS sensor significantly increased and indicated a roughly linear relationship at the optimal operating temperature of 260 °C. The ethanol-selective characteristics of the CuS sensor against other interfering gases including methanol, benzene, dichloromethane, and hexane were studied, and the gas response of the CuS sensor synthesized at 170 °C toward 100 ppm ethanol was 5.22, which was significantly higher than all the other gases. Moreover, 14-day continuous measurement further confirmed the excellent stability of the CuS sensor.

36 MATERIALS SCIENCE↗

Embedded Sensors in Additively Manufactured Silicon Carbide

Silicon carbide (SiC) components are being considered for a wide range of nuclear applications due to their high-temperature strength retention, low neutron absorption, chemical inertness, and dimensional stability under neutron irradiation. However, machining and joining of SiC components have traditionally limited its application to relatively simple geometries. Recent work has demonstrated additive manufacturing of complex, high-purity, crystalline SiC components using a combination of binder jet printing and densification via chemical vapor infiltration (CVI). The process lends itself to embedding of fuel, absorbers, moderators, and sensors at strategic locations within a component. The latter could allow for enhanced in situ performance monitoring of limiting fuel temperatures, self-shielded neutron flux, and potentially spatially distributed strain within complex SiC components if sensors can be successfully embedded during CVI. This work describes (1) methods for embedding sensors; (2) thermodynamic analyses and material compatibility testing for identifying sensors capable of surviving high temperatures and exposure to hydrogen and hydrogen chloride during CVI; and (3) nuclear applications for embedded sensors, including potential failure modes during fabrication and during reactor operation. Molybdenum-sheathed thermocouples were successfully embedded in a complex SiC component, whereas niobium-sheathed high-temperature irradiation-resistant thermocouples started to drift as soon as the reactant gases were introduced and ultimately failed during CVI due to severe constrained expansion, potentially resulting from niobium hydride formation in the low-temperature region of the CVI system. Optical fibers were successfully embedded in SiC, but further work is needed to protect the fragile fiber leads after their protective coatings are removed during CVI.

thermocouples↗

Glassy carbon formation from pyrolysis of polymeric coatings on fiber-optic sensors

Deploying fiber-optic sensors in nuclear reactors requires a detailed understanding of radiation effects on the fiber materials and the transmitted signals. Previous work has shown large wavelength shifts in the reflected spectra obtained from polymer-coated fiber-optic temperature sensors exposed to high neutron fluences. The sensor drift resulting from these wavelength shifts cannot be explained by radiation effects on fused silica glass. These shifts are hypothesized to be caused by the conversion of the polymeric fiber coating to a glassy carbon via radiolysis and/or pyrolysis and subsequent radiation-induced compaction. Here, thermal degradation of these polymeric coatings was studied to provide insight into the potential origins of the sensor drift phenomenon. Acrylate- and polyimide-coated fibers were heated under various temperatures (250–1300 °C) and environments (oxidative and inert), and the resulting coating products were characterized via mass-loss data, scanning electron microscope imaging, and Raman spectroscopy. Results suggest that the polymer decomposition product of both coating types, at least under inert conditions, is indeed a glassy carbon. Analytical models that account for radiation-induced glassy carbon coating compaction show significant compressive fiber strains and predicted wavelength shifts that agree well with experimental measurements, providing additional evidence that supports the hypothesized origins of the sensor drift.

36 MATERIALS SCIENCE↗

Face mask integrated with flexible and wearable manganite oxide respiration sensor

Face masks are key personal protective equipment for reducing exposure to viruses and other environmental hazards such as air pollution. Integrating flexible and wearable sensors into face masks can provide valuable insights into personal and public health. The advantages that a breath-monitoring face mask requires, including multi-functional sensing ability and continuous, long-term dynamic breathing process monitoring, have been underdeveloped to date. Here, we design an effective human breath monitoring face mask based on a flexible La 0.7 Sr 0.3 MnO 3 (LSMO)/Mica respiration sensor. The sensor’s capabilities and systematic measurements are investigated under two application scenes, namely clinical monitoring mode and daily monitoring mode, to monitor, recognise, and analyse different human breath status, i.e., cough, normal breath, and deep breath. This sensing system exhibits super-stability and multi-modal capabilities in continuous and long-time monitoring of the human breath. We determine that during monitoring human breath, thermal diffusion in LSMO is responsible for the change of resistance in flexible LSMO/Mica sensor. Both simulated and experimental results demonstrate good discernibility of the flexible LSMO/Mica sensor operating at different breath status. Our work opens a route for the design of novel flexible and wearable electronic devices.

36 MATERIALS SCIENCE↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

The energy footprint of automotive electronic sensors

We discuss how Information and communication technologies (ICT) have emerged as one of the leading technologies to reduce global emissions, particularly in the mobility sector. Automotive electronics, such as sensors/actuators and microcontrollers (commonly known as electronic control units (ECU) which control one or more of the electrical systems or subsystems in a vehicle), play a key role in ICT. Sensors/actuators are key in electronic ICT devices, starting with the data collection and data communication with the internet. The latest two big trends of electrification and automation in vehicles, are projected to increase the use of worldwide automotive sensors from 7.5 billion units in 2017 to 11.0 billion units by the year 2024. A representative state-of-the art automotive sensor system, (i.e., an ultrasonic backup system), including the ECUs controlling the vehicle electrical systems/subsystems, has been considered to estimate the energy footprint in terms of manufacturing and operational energy of global automotive sensors use. A widely used life cycle energy assessment method (i.e., cumulative energy demand) was used as both direct and indirect (including the extraction, manufacturing, and disposal of the raw and auxiliary materials) energy use can be considered for the energy footprint estimation. The embodied manufacturing energy impacts of the system was estimated to be 559 MJ/system, compared to the 417 MJ/system for lifetime system power and additional gasoline use. The share of purchased energy to the embodied energy where the upstream energy isn't included in the former case, is less than 10% and ~ 85% for the component manufacturing and vehicle operation energy uses, respectively. As the purpose of this ultrasonic backup system is to prevent rear crashes, an estimated 1.0 MJ/system is avoided from reduced lifetime vehicular repairs (from an estimated 11% chance of requiring a rear bumper replacement). While all of this is small compared to the overall automotive manufacturing and use energy, the 11 billion automotive sensors expected to be produced in 2024 could require 1540 PJ for manufacturing and those sensors would require an additional 780–1150 PJ for lifetime energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Printed Potentiometric Ammonium Sensors for Agriculture Applications

Ammonium (NH 4 + ) concentration is critical to both nutrient availability and nitrogen (N) loss in soil ecosystems but can be highly variable across spatial and temporal scales. For this reason, effectively informing agricultural practices such as fertilizer management and understanding of mechanisms of soil N loss require sensor technologies to monitor ammonium concentrations in real time. Our work investigates the performance of fully printed ammonium ion-selective sensors used in diverse soil environments. Ammonium sensors consisting of a printed ammonium ion-selective electrode and a printed Ag/AgCl reference were fabricated and characterized in aqueous solutions and three different soil types (sand, peat, and clay) under the range of ion concentrations likely to be present in soil (0.01–100 mM). The response of ammonium sensors was further evaluated under variable gravimetric moisture content in the soil to reflect their reliability under field conditions. Ammonium sensors demonstrated a sensitivity of 53.6 ± 5.1 mV/decade when tested in aqueous solution, and a sensitivity of 55.7 ± 11 mV/dec, 57.5 ± 4.1 mV/dec, and 43.7 ± 4 mV/dec was measured in sand, clay, and peat soils, respectively.

60 APPLIED LIFE SCIENCES↗

Optical Fiber Sensor with a Hydrophobic Filter Layer for Monitoring Hydrogen under Humid Conditions

Real-time and remote monitoring of hydrogen concentration in underground hydrogen storage reservoirs is crucial to maintaining the integrity and safety of the storage facilities. High humidity in the underground deposits interferes with hydrogen sensors, introducing inaccuracy into the hydrogen sensing measurements. A hydrophobic filter layer over a hydrogen sensing layer on an optical fiber hydrogen sensor was devised to minimize the impact of the humidity on the sensor. The hydrogen sensor coated with a hydrophobic filter layer demonstrated a significant improvement in reliable hydrogen sensing under high humidity conditions (99% RH) without severe baseline drift and reduction of transmission intensity. Finally, the optical fiber hydrogen sensor revamped with the filter layer would enable the reliable measurement of hydrogen concentration under the humid conditions expected in subsurface hydrogen storage facilities.

08 HYDROGEN↗

Real-Time Ammonia and Humidity Monitoring with Ultra-Fast Conductometric Sensors Based on Porphyrin and Phthalocyanine Complexes

Organic semiconductors like porphyrins and phthalocyanines are attracting a wide range of researchers due to their versatile electrical properties and sensing performances in conductometric sensors. In this study, we investigate two types of π-extended porphyrins, which share the same macrocyclic structure but differ in their central metal. These porphyrins are employed as sublayers in bilayer heterojunction devices, with the lutetium bisphthalocyanine complex, LuPc 2 , serving as the common top layer. Remarkably, the central metal in the porphyrin macrocycle significantly influences the solubility of the materials and, consequently, the surface topography of the resulting bilayer heterojunction devices. This structural variation translates into distinct electrical and sensing performances. The device incorporating nickel as metal centre (AM2) demonstrates superior sensitivity towards NH3, with a relative response (RR) of ca. -7% at 90 ppm, an ultra-fast response time of about 9 s, and an impressive limit of detection (LOD) of 250 ppb, whereas, the device that has zinc as metal centre in sublayer (AM3) exhibits RR value of ca. -0.9% at 90 ppm with t 90 of ca. 120 s and LOD of 2 ppm. Both devices are evaluated under randomly varying NH 3 concentration and RH value. The results shows that the AM2-based sensor allows following NH 3 in real-time, while the AM3-based sensor delivers an average concentration over time. On the other hand, the AM2-based sensor exhibits slow kinetics under RH exposure, while the AM3-based sensor precisely mirrors the pattern of random RH changes generated by the software, demonstrating its exceptional responsiveness and accuracy in tracking humidity fluctuations. In conclusion, these findings underscore the critical role of the metal centre in tuning the electrical and sensing properties of the heterojunction devices.

99 GENERAL AND MISCELLANEOUS↗