Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Autoionizing Polaritons in Attosecond Atomic Ionization

Light-induced states and Autler-Townes splitting of laser-coupled states are common features in the photoionization spectra of laser-dressed atoms. The entangled light-matter character of metastable Autler-Townes multiplets, which makes them autoionizing polaritons, however, is still largely unexplored. We employ attosecond transient-absorption spectroscopy in argon to study the formation of polariton multiplets between the 3s –1 4p and several light-induced states. We measure a controllable stabilization of the polaritons against ionization, in excellent agreement with ab initio theory. Using an extension of the Jaynes-Cummings model to autoionizing states, we show that this stabilization is due to the destructive interference between the Auger decay and the radiative ionization of the polaritonic components. Furthermore, these results give new insights into the optical control of electronic structure in the continuum and unlock the door to applications of radiative stabilization in metastable polyelectronic systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

A line-source method for aligning on-board and other pinhole SPECT systems

Purpose: In order to achieve functional and molecular imaging as patients are in position for radiation therapy, a robotic multipinhole SPECT system is being developed. Alignment of the SPECT system—to the linear accelerator (LINAC) coordinate frame and to the coordinate frames of other on-board imaging systems such as cone-beam CT (CBCT)—is essential for target localization and image reconstruction. An alignment method that utilizes line sources and one pinhole projection is proposed and investigated to achieve this goal. Potentially, this method could also be applied to the calibration of the other pinhole SPECT systems.Methods: An alignment model consisting of multiple alignment parameters was developed which maps line sources in three-dimensional (3D) space to their two-dimensional (2D) projections on the SPECT detector. In a computer-simulation study, 3D coordinates of line-sources were defined in a reference room coordinate frame, such as the LINAC coordinate frame. Corresponding 2D line-source projections were generated by computer simulation that included SPECT blurring and noise effects. The Radon transform was utilized to detect angles (α) and offsets (ρ) of the line-source projections. Alignment parameters were then estimated by a nonlinear least squares method, based on the α and ρ values and the alignment model. Alignment performance was evaluated as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise, and acquisition geometry. Experimental evaluations were performed using a physical line-source phantom and a pinhole-collimated gamma camera attached to a robot.Results: In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, six alignment parameters (three translational and three rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by the Radon transform, estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution, and detector acquisition geometry. Statistically, the estimation accuracy was significantly improved by using four line sources rather than three and by thinner line-source projections (obtained by better intrinsic detector resolution). With five line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt, and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.Conclusions: Alignment parameters can be estimated using one pinhole projection of line sources. Alignment errors are largely associated with limited accuracy of the Radon transform in determining angles (α) and offsets (ρ) of the line-source projections. This alignment method may be important for multipinhole SPECT, where relative pinhole alignment may vary during rotation. For pinhole and multipinhole SPECT imaging on-board radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT Phantom{sup TM}), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the pinhole region-of-interest imaging. Conclusions: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MicroBooNE low-energy excess signal prediction from unfolding MiniBooNE Monte-Carlo and data

One of the primary goals of MicroBooNE is to address the existence and underlying source of the MiniBooNE observed Low Energy Excess (LEE). The MiniBooNE LEE is the observation of an anomalous excess of νe charged current quasi-elastic-like events in the Booster Neutrino Beam at Fermilab. The true origin of those events could be attributed to either single electrons or single photons produced in the MiniBooNE Cherenkov detector, as the experiment lacked the ability to distinguish between the two. Using the ability of liquid argon time projection chambers to perform electron/photon separation, MicroBooNE aims to search for this excess in two exclusive channels: single photon and single electron. However before addressing either hypothesis the MiniBooNE LEE must be explicitly modeled in MicroBooNE. This requires that the MiniBooNE detector response, event reconstruction, selection and their collective effects be removed before mapping the observable excess to MicroBooNE. This note describes this “unfolding process,” and provides the end results of the true unfolded distributions for two well motivated LEE hypotheses: (a) electrons from an increased intrinsic νe charged current event rate and (b) single photons due to neutrino neutral current Δ production with subsequent radiative decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation damage in scientific charge-coupled devices

Radiation damage is reported on CCDs (charge-coupled devices) that have been primarily exposed to 1.25-MeV gamma rays (Co-60 source). Two important classes of radiation damage are discussed, namely, bulk and ionization effects. Bulk damage or displacement damage is a process in which silicon atoms are displaced from their normal lattice positions by high-energy photons or particles. Single atomic displacements or cluster defect damage is produced, depending on the energy and type of radiation experienced by the detector. Bulk damage creates trapping sites within the CCD's signal channel which in turn degrades charge-transfer efficiency.

Janesick, James↗

Photo-fragmentation of the closo-carboranes Part 1: Energetics of Decomposition

The ionic fragmentation following B 1s and C 1s excitation of three isomeric carborane cage compounds [closo-dicarbadodecaboranes: orthocarborane (1,2-C2B10H12), metacarborane (1,7-C2B10H12), and paracarborane (1,12-C2B10H12)], is compared with the energetics of decomposition. The fragmentation yields for all three molecules are quite similar. Thermodynamic cycles are constructed for neutral and ionic species in an attempt to systemically characterize single ion closo-carborane creation and fragmentation processes. Lower energy decomposition processes are favored. Among the ionic species, the photon induced decomposition isdominated by BH+ and BH2+ fragment loss. Changes in ion yield associated with core to bound excitations are observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High quality single crystal Ge nano-membranes for opto-electronic integrated circuitry

A thin, flat, and single crystal germanium membrane would be an ideal platform on which to mount sensors or integrate photonic and electronic devices, using standard silicon processing technology. We present a fabrication technique compatible with integrated-circuit wafer scale processing to produce membranes of thickness between 60 nm and 800 nm, with large areas of up to 3.5 mm{sup 2}. We show how the optical properties change with thickness, including appearance of Fabry-Pérot type interference in thin membranes. The membranes have low Q-factors, which allow the platforms to counteract distortion during agitation and movement. Finally, we report on the physical characteristics showing sub-nm roughness and a homogenous strain profile throughout the freestanding layer, making the single crystal Ge membrane an excellent platform for further epitaxial growth or deposition of materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of the TITAN Hybrid Deterministic Transport Code to Medical Physics - Paper 118

The TITAN code is a 3-dimensional parallel deterministic transport code that solves the linear Boltzmann equation. The TITAN code has hybrid algorithms that are ideal for medical physics applications: i) SN and characteristics method and ii) SN with a fictitious quadrature set and ray-tracing. These hybrid algorithms have been used in the simulation of computed tomography (CT) and single photon emission computed tomography (SPECT) In this paper, the hybrid algorithms developed for medical physics applications in the TITAN code are discussed. First, the TITAN code's block-oriented approach for utilizing SN and characteristic solvers for CT is presented and results for a simple test case are given. Second, the paper describes a hybrid formulation for SPECT with an SN solver in the phantom, a fictitious quadrature set for directions from the phantom surface passing through the collimator, and a simplified ray-tracing algorithm for particle transport to the detector. Finally, ongoing work is described and concluding remarks are given. The TITAN code's hybrid algorithms allow it to efficiently solve problems with low-scatter regions, which are frequently found in medical physics applications. The TITAN code has been used to solve a simplified CT problem and generate projection images for SPECT simulations. The WCOS technique was developed to improve the TITAN code's collimator representation. For these applications, the TITAN code was shown to require significantly less computation time than MCNP5. Work is currently underway to implement an iterative image reconstruction algorithm in the TITAN code. A script that calls the TITAN code to complete the forward projection step in SPECT has already been used to reconstruction a 2-dimensional phantom. The ability of TITAN to fully model particle transport in the patient in short computation times is expected to be a great advantage to iterative reconstruction. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

CryoPDK Development for 22nm FDSOI CryoCMOS

Cryogenic Process Design Kits (PDKs) are an indispensable tool in the design of complex integrated circuits across a wide spectrum of applications, from noble element detectors to Quantum Information Science, Superconducting Nanowire Single Photon Detectors (SNSPDs), and precision atomic clocks. The development of PDK-compatible SPICE models is a complex endeavor requiring test structures, measurements, model extraction and fitting. We will present the cryogenic modeling and development of a cryo-PDK for a 22nm FDSOI CMOS process for operation at 3.8 Kelvin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 3% Measurement of the Beam Normal Single Spin Asymmetry in Forward Angle Elastic Electron-Proton Scattering using the Qweak Setup

The beam normal single spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable of the imaginary part of the two-photon exchange process. Moreover, it is a potential source of false asymmetry in parity violating electron scattering experiments. The Q{sub weak} experiment uses parity violating electron scattering to make a direct measurement of the weak charge of the proton. The targeted 4% measurement of the weak charge of the proton probes for parity violating new physics beyond the Standard Model. The beam normal single spin asymmetry at Q{sub weak} kinematics is at least three orders of magnitude larger than 5 ppb precision of the parity violating asymmetry. To better understand this parity conserving background, the Q{sub weak} Collaboration has performed elastic scattering measurements with fully transversely polarized electron beam on the proton and aluminum. This dissertation presents the analysis of the 3% measurement (1.3% statistical and 2.6% systematic) of beam normal single spin asymmetry in electronproton scattering at a Q2 of 0.025 (GeV/c)2. It is the most precise existing measurement of beam normal single spin asymmetry available at the time. A measurement of this precision helps to improve the theoretical models on beam normal single spin asymmetry and thereby our understanding of the doubly virtual Compton scattering process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Near- K -edge single, double, and triple photoionization of C + ions

Single, double, and triple ionization of the C + ion by a single photon have been investigated in the energy range 286 to 326 eV around the K-shell single-ionization threshold at an unprecedented level of detail. At energy resolutions as low as 12 meV, corresponding to a resolving power of 24 000, natural linewidths of the most prominent resonances could be determined. From the measurement of absolute cross sections, oscillator strengths, Einstein coefficients, multielectron Auger decay rates, and other transition parameters of the main K-shell excitation and decay processes are derived. The cross sections are compared to results of previous theoretical calculations. Mixed levels of agreement are found despite the relatively simple atomic structure of the C + ion with only five electrons. Finally, this paper is a followup to a previous Letter [A. Müller, Phys. Rev. Lett. 114, 013002 (2015)PRLTAO0031-900710.1103/PhysRevLett.114.013002].

74 ATOMIC AND MOLECULAR PHYSICS↗

Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity quantification compared to SPECT with AC only. The proposed methodology can readily be used to tailor {sup 90}Y SPECT/CT acquisition and reconstruction protocols with different SPECT/CT systems for quantification and improved image quality in clinical settings.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direction-dependent localization errors in SPECT images

Purpose: Single photon emission computed tomography (SPECT) is being investigated for imaging inside radiation therapy treatment rooms to localize biological targets. Here, computer simulations were used to analyze locational and directional dependencies in localization errors and to assess the effects of spatial resolution modeling and observer normalization on localization performance. Methods: SPECT images of the XCAT phantom, containing 12 hot tumors, were reconstructed with detector response function compensation (DRC) and without DRC (nDRC). Numerical observers were forced to select the most suspicious tumor location, using normalized cross correlation (NXC) or un-normalized cross correlation (XC), from 3 cm diameter search volumes that each contained only one tumor. For each tumor site, localization was optimized as a function of the iteration number and postreconstruction smoothing. Localization error, the distance between true and estimated tumor positions, was calculated across the ensembles of 80 images. Direction-dependent localization bias and precision were estimated from the image ensemble. Results: For the six superficial tumors in close proximity to the detector trajectory, mean localization errors were <2 mm and were lowest or comparable using DRC-NXC, though differences from DRC-XC and nDRC-NXC were not statistically significant. DRC-NXC did provide statistically significantly better localization than nDRC-XC for five of these six tumors. At the other six sites where attenuation was more severe and the distance was generally greater between the tumor and detector, DRC typically did not show better localization than nDRC. Observer normalization improved the localization substantially for a tumor near the hotter heart. Localization errors were anisotropic and dependent on tumor location relative to the detector trajectory. Conclusions: This computer-simulation study compared localization performance for normalized and un-normalized numerical observers, which were used to estimate tumor positions in SPECT images, reconstructed with and without DRC. For tumors localized to <2 mm on average, which are good candidates for SPECT-guided radiation therapy, localization performance typically improved by compensating for the detector response function and by using a normalized observer. The observed direction-dependent localization errors have important implications for radiation therapy and are relevant to SPECT imaging in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-chip frequency-bin quantum photonics

Abstract Frequency-bin encoding furnishes a compelling pathway for quantum information processing systems compatible with established lightwave infrastructures based on fiber-optic transmission and wavelength-division multiplexing. Yet although significant progress has been realized in proof-of-principle tabletop demonstrations, ranging from arbitrary single-qubit gates to controllable multiphoton interference, challenges in scaling frequency-bin processors to larger systems remain. In this Perspective, we highlight recent advances at the intersection of frequency-bin encoding and integrated photonics that are fundamentally transforming the outlook for scalable frequency-based quantum information. Focusing specifically on results on sources, state manipulation, and hyperentanglement, we envision a possible future in which on-chip frequency-bin circuits fulfill critical roles in quantum information processing, particularly in communications and networking.

electro-optic modulators↗

Spurious poles in the scattering of electric and magnetic charges

Theories with both electric and magnetic charges (“mutually non-local” theories) have several major obstacles to calculating scattering amplitudes. Even when the interaction arises through the kinetic mixing of two, otherwise independent, U(1)’s, so that all low-energy interactions are perturbative, difficulties remain: using a self-dual, local formalism leads to spurious poles at any finite order in perturbation theory. Correct calculations must show how the spurious poles cancel in observable scattering amplitudes. Consistency requires that one type of charge is confined as a result of one of the U(1)’s being broken. Here we show how the constraints of confinement and parity conservation on observable processes manages to cancel the spurious poles in scattering and pair production amplitudes, paving the way for systematic studies of the experimental signatures of “dark” electric-magnetic processes. Along the way we demonstrate some novel effects in electric-magnetic interactions, including that the amplitude for single photon production of magnetic particles by electric particles vanishes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Q cavity interface for color centers in thin film diamond

Quantum information technology offers the potential to realize unprecedented computational resources via secure channels distributing entanglement between quantum computers. Diamond, as a host to optically-accessible spin qubits, is a leading platform to realize quantum memory nodes needed to extend such quantum links. Photonic crystal (PhC) cavities enhance light-matter interaction and are essential for an efficient interface between spins and photons that are used to store and communicate quantum information respectively. Here, we demonstrate one- and two-dimensional PhC cavities fabricated in thin-film diamonds, featuring quality factors (Q) of 1.8 × 10 5 and 1.6 × 10 5 , respectively, the highest Qs for visible PhC cavities realized in any material. Importantly, our fabrication process is simple and high-yield, based on conventional planar fabrication techniques, in contrast to the previous with complex undercut processes. We also demonstrate fiber-coupled 1D PhC cavities with high photon extraction efficiency, and optical coupling between a single SiV center and such a cavity at 4 K achieving a Purcell factor of 18. The demonstrated photonic platform may fundamentally improve the performance and scalability of quantum nodes and expedite the development of related technologies.

97 MATHEMATICS AND COMPUTING↗

THE SUZAKU VIEW OF THE DISK-JET CONNECTION IN THE LOW-EXCITATION RADIO GALAXY NGC 6251

We present results from an 87 ks Suzaku observation of the canonical low-excitation radio galaxy (LERG) NGC 6251. We have previously suggested that LERGs violate conventional active galactic nucleus unification schemes: they may lack an obscuring torus and are likely to accrete in a radiatively inefficient manner, with almost all of the energy released by the accretion process being channeled into powerful jets. We model the 0.5-20 keV Suzaku spectrum with a single power law of photon index {Gamma} = 1.82{sup +0.04} {sub -0.05}, together with two collisionally ionized plasma models whose parameters are consistent with the known galaxy- and group-scale thermal emission. Our observations confirm that there are no signatures of obscured, accretion-related X-ray emission in NGC 6251, and we show that the luminosity of any such component must be substantially sub-Eddington in nature.

79 ASTRONOMY AND ASTROPHYSICS↗

Excitation of the Isomeric {sup 229m}Th Nuclear State via an Electronic Bridge Process in {sup 229}Th{sup +}

We consider the excitation of the nuclear transition {sup 229g}Th-{sup 229m}Th near 7.6 eV in singly ionized thorium via an electronic bridge process. The process relies on the excitation of the electron shell by two laser photons whose sum frequency is equal to the nuclear transition frequency. This scheme allows us to determine the nuclear transition frequency with high accuracy. Based on calculations of the electronic level structure of Th{sup +} which combine the configuration-interaction method and many-body perturbation theory, we estimate that a nuclear excitation rate in the range of 10 s{sup -1} can be obtained using conventional laser sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗