Search NASA⌕ Search

SEARCH · Search NASA

Results for “small lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Low-Flow-Rate Dry-Powder Feeder

Apparatus feeds small, precise flow of dry powder through laser beam of optical analyzer, measuring patterns of light created by forward scattering (Fraunhofer diffraction) of laser beam from powder particles. From measurement, statistical distribution of sizes of powder particles computed. Developed for analyzing particle-size distributions of solid-propellant powders. Also adapted to use in pharmaceutical industry, in manufacture of metal powder, and in other applications in which particle-size distributions of materials used to control rates of chemical reactions and/or physical characteristics of processes.

Ramsey, Keith E.↗

Low-Flow-Rate Dry-Powder Feeder

Apparatus feeds small, precise flow of dry powder through laser beam of optical analyzer measuring patterns of light created by forward scattering (Fraunhofer diffraction) of laser beam from powder particles. From this optical measurement, statistical distribution of sizes of powder particles computed. Rates of flow optimized for measurement of particle-size distributions. Developed for analyzing particle-size distributions of solid-propellant powders. Also adapted to pharmaceutical industry, in manufacture of metal powder, and in other applications where particle-size distributions of materials used to control rates of chemical reactions and/or physical characteristics of processes.

Ramsey, Keith E.↗

Fundamental Mixing and Combustion Experiments for Propelled Hypersonic Flight

The first experiment is a study of a coaxial jet discharging into stagnant laboratory air, with center jet of a mixture of 5% oxygen and 95% helium by volume and coflow jet of air. The exit flow pressure of both center-jet and coflow nozzles is 1 atmosphere. The presence of oxygen in the center jet is to allow the use of an oxygen flow-tagging technique (RELIEF4) to obtain non-intrusive velocity measurements. Both jets are nominally Mach 1.8, but, because of the greater speed of sound, the center jet velocity is more than twice that of the coflow. The mixing layer which forms between the center jet and the coflow near the nozzle exit is compressible, with a calculated convective Mach number of approximately 0.7. This geometry has several advantages: The streamwise development of the flow is generally dominated by turbulent stresses (rather than pressure forces), and thus calculations are sensitive to turbulence modeling. It includes features present in supersonic combustors, including a compressible mixing layer near the nozzle exit and a light-gas/air plume downstream. Since it is a free jet, it provides easy access for both optical instrumentation and probes. Since it is axisymmetric, it requires fewer experimental measurements to fully characterize, and calculations can be performed with more modest computer resources. However, weak shock waves formed at the nozzle exit strengthen and turn normal as they approach the axis, complicating the flow. Care is thus taken in the design of the facility to provide as near as possible to 1-D flow at the exit of both center and coflow nozzles, and to minimize the strength of waves generated at the nozzle exit. Results from this experiment are compared to CFD solutions obtained by VULCAN, a previously developed code used in engine analysis. The second experiment is a study of a supersonic combustor consisting of a diverging duct with single downstream-angled wall injector. Thus, the geometry is relatively simple and large regions of subsonic recirculating flow are avoided. The nominal entrance Mach number is 2 and the enthalpy of the test gas (hot air "simulant") is nominally that of Mach 7 flight. It was believed, on the basis of calculations performed that this would produce mixing-limited flow, that is to say, one for which chemical reaction to equilibrium proceeds at a much greater rate than mixing. It later proved that this was not the case. The primary experimental technique employed is coherent anti-Stokes Raman spectroscopy, known by its acronym CARS. The species probed is molecular nitrogen and the quantity measured is temperature. Intrusive probes, such as Pitot, total temperature, hot-wire, etc., are not used due to access difficulty and high heat flux in the combustor, and because they may alter the flow. CARS has several advantages over other optical methods. It is a relatively mature and well-understood technique. Signal levels are relatively high and the signal is in the form of a coherent (laser) beam that can be collected through small windows. Incoherent (non-CARS) interferences are rejected by spatial filtering.

Diskin, G. S.↗

Spectroscopic and Computational Studies of Spin-Orbit Coupling of Lanthanide Oxides

Spin-orbit (SO) coupling makes it possible for spin forbidden transitions or reactions within non-relativistic quantum theory feasible. Thus, quantification of such interactions has important implications in photophysics and chemical catalysis. This work aims to quantify SO interactions using lanthanide (Ln) oxides as target molecular systems. Through these systems, we examine the impact on the SO coupling by electron configurations and 4f orbital occupancies of Ln elements and sizes of the metal oxides. By examining these factors, we explore how SO coupling is affected by the number of Ln 4f electrons for a given size of molecules and if the Ln 4f orbitals remain atomic in nature in these small clusters. Ln oxides are produced in laser ablation molecular beams, identified with time-of-fight mass spectrometry, and characterized with laser spectroscopy and relativistic quantum chemical computations. Spectroscopic measurements include mass-analyzed threshold ionization (MATI), zero electron kinetic energy, and slow electron velocity-map imaging spectroscopies. Relativistic computations treat scalar relativistic corrections, electron correlations, and SO interactions. The main results are SO terms and energies of the neutral molecules and singly charged cations, ionization energies of the neutral species, metal-metal and metal-oxygen vibrational frequencies of the ions and, in some cases, neutrals as well, and charge effects on the bonding and structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NIR fluorescence lifetime macroscopic imaging with a time-gated SPAD camera

The performance of SwissSPAD2 (SS2), a large scale, widefield time-gated CMOS SPAD imager developed for fluorescence lifetime imaging, has recently been described in the context of visible range and fluorescence lifetime imaging microscopy (FLIM) of dyes with lifetimes in the 2.5 – 4 ns range. Here, we explore its capabilities in the NIR regime relevant for small animal imaging, where its sensitivity is lower and typical NIR fluorescent dye lifetimes are much shorter (1 ns or less). We carry out this study in a simple macroscopic imaging setup based on a compact NIR picosecond pulsed laser, an engineered diffuser-based illumination optics, and NIR optimized imaging lens suitable for well-plate or small animal imaging. Because laser repetition rates can vary between models, but the synchronization signal frequency accepted by SS2 is fixed to 20 MHz, we first checked that a simple frequency-division scheme enables data recording for different laser repetition rates. Next, we acquired data using different time gate widths, including gates with duration longer than the laser period, and analyzed the resulting data using both standard nonlinear least-square fit (NLSF) and phasor analysis. We show that the fixed synchronization rate and large gate widths characterizing SS2 (10 ns and over) are not an obstacle to accurately extracting lifetime in the 1 ns range and to distinguishing between close lifetimes. As a result, SS2 and similar very large gated SPAD imagers appear as a versatile alternative to other widefield time-resolved detectors for NIR fluorescence lifetime imaging, including preclinical molecular applications.

FLIM↗

w22_laser-radiography: Laser-Based MeV Radiography [Slides]

X-ray sources based on high-power short pulse lasers have unique advantages over conventional sources, like small spot size, flexible configuration, and tailorable spectra. Development of these sources will allow LANL to fulfill an urgent need to deploy flexible, compact, x-ray sources for static and dynamic radiography at our firing sites and facilities such as pRad and U1a. Our IC allocation supports the development of a predictive modeling capability of these laser-based sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Airborne Laser Altimetry to Detect Topographic Change at Long Valley Caldera California

The topography of the Long Valley caldera, California, was sampled using airborne laser altimetry in 1993, 1995, and 1997 to test the feasibility of using airborne laser altimetry for monitoring deformation of volcanic origin. Results show the laser altimeters are able to resolve subtle topographic features such as a gradual slope and to detect small transient changes in lake elevation. Crossover and repeat pass analyses of laser tracks indicate decimeter-level vertical precision is obtained over flat and low-sloped terrain for altimeter systems performing waveform digitization. Comparisons with complementary, ground-based CPS data at a site close to Bishop airport indicate that the laser and GPS-derived elevations agree to within the error inherent in the measurement and that horizontal locations agree to within the radius of the laser footprint. A comparison of the data at two sites, one where no change and the other where the maximum amount of vertical uplift is expected, indicates approximately 10 cm of relative uplift occurred 1993-1997, in line with predictions from continuous CPS measurements in the region. Extensive terrain mapping flights during the 1995 and 1997 missions demonstrate some of the unique abilities of laser altimetry; the straightforward creation of high resolution, high accuracy digital elevation models of overflown terrain, and the ability to determine ground topography in the presence of significant ground cover such as dense tree canopies. These capabilities make laser altimetry an attractive technique for quantifying topographic change of volcanic origin, especially in forested regions of the world where other remote sensing instruments have difficulty detecting the underlying topography.

Hofton, M. A.↗

Using Airborne Laser Altimetry to Detect Topographic Change at Long Valley Caldera, California

The topography of the Long Valley caldera, California, was sampled using airborne laser altimetry in 1993, 1995, and 1997 to test the feasibility of using airborne laser altimetry for monitoring deformation of volcanic origin. Results show the laser altimeters are able to resolve subtle topographic features such as a gradual slope and to detect small transient changes in lake elevation. Crossover and repeat pass analyses of laser tracks indicate decimeter-level vertical precision is obtained over flat and low-sloped terrain for altimeter systems performing waveform digitization. Comparisons with complementary, ground-based GPS data at a site close to Bishop airport indicate that the laser and GPS-derived elevations agree to within the error inherent in the measurement and that horizontal locations agree to within the radius of the laser footprint. A comparison of the data at two sites, one where no change and the other where the maximum amount of vertical uplift is expected, indicates approximately 10 cm of relative uplift occurred 1993-1997, in line with predictions from continuous GPS measurements in the region. Extensive terrain mapping flights during the 1995 and 1997 missions demonstrate some of the unique abilities of laser altimetry; the straightforward creation of high resolution, high accuracy digital elevation models of overflown terrain, and the ability to determine ground topography in the presence of significant ground cover such as dense tree canopies. These capabilities make laser altimetry an attractive technique for quantifying topographic change of volcanic origin, especially in forested regions of the world where other remote sensing instruments have difficulty detecting the underlying topography.

Hofton, M. A.↗

Emerging continuous SiC fibers for high-temperature applications

Silicon carbide (SiC) fibers are responsible for the ultimate strength and toughness of SiC-fiber reinforced composites in harsh environments. The development of a new generation of continuous SiC fibers continues to advance the mechanical properties of composite materials. Tyranno™ SA4 fiber was recently released as a successor of Tyranno™ SA3 fiber. Laser-driven chemical vapor deposition (LCVD) has been adopted as an alternative fiber processing route to synthesizing high-strength SiC fiber with tailorable small diameters and chemical compositions. Both Tyranno™ SA4 and laser-driven CVD fibers show very high tensile strength, about 4 GPa in the as-fabricated condition. The degradation of thermal stability and strength due to annealing in an inert environment were similar for Tyranno™ SA3 and SA4 fibers because of their similar carbon-rich, crystalline microstructure. Silicon-rich fibers produced by LCVD possessed heterogeneous crystallinity, which was attributed to laser power distribution and showed microstructural instability at 1500 °C and above. Finally, the new SiC fibers demonstrated an increase in as-fabricated strength but faced the same challenges in environmental resistance as the traditional SiC fibers do.

36 MATERIALS SCIENCE↗

Architectural design of a ground-based deep-space optical reception antenna

An architectural design of a ground-based antenna (telescope) for receiving optical communications from deep space is presented. Physical and optical parameters, and their effect on the performance and cost considerations, are described. The channel capacity of the antenna is 100 kbits/s from Saturn and 5 Mbits/s from Mars. A novel sunshade is designed to permit optical communication even when the deep-space laser source is as close to the sun as 12 deg. Inserts in the tubes of the sunshade permit operations at solar elongations as small as 6 or 3 deg. The Nd:YAG source laser and the Fraunhofer filter (a narrow-band predetection optical filter) are tuned to match the Doppler shifts of the source and background. A typical Saturn-to-earth data link can reduce its source power requirement from 8.2 W to 2 W of laser output by employing a Fraunhofer filter instead of a conventional multilayer dielectric filter.

Kerr, E. L.↗

Small Business Innovations

A Small Business Innovation Research (SBIR) contract resulted in a series of commercially available lasers, which have application in fiber optic communications, difference frequency generation, fiber optic sensing and general laboratory use. Developed under a Small Business Innovation Research (SBIR) contract, the Phase Doppler Particles Analyzer is a non-disruptive, highly accurate laser-based method of determining particle size, number density, trajectory, turbulence and other information about particles passing through a measurement probe volume. The system consists of an optical transmitter and receiver, signal processor and computer with data acquisition and analysis software. A variety of systems are offered for applications including spray characterization for paint, and agricultural and other sprays. The Microsizer, a related product, is used in medical equipment manufacturing and analysis of contained flows. High frequency components and subsystems produced by Millitech Corporation are marketed for both research and commercial use. These systems, which operate in the upper portion of the millimeter wave, resulted from a number of Small Business Innovation Research (SBIR) projects. By developing very high performance mixers and multipliers, the company has advanced the state of the art in sensitive receiver technology. Components are used in receivers and transceivers for monitoring chlorine monoxides, ozone, in plasma characterization and in material properties characterization.

Source record↗

Polar nephelometer for atmospheric particulate studies

A polar nephelometer for use in studying atmospheric aerosols was developed. The nephelometer detects molecular scatter from air and measures scattering from very clean air using pure molecular scattering for calibration. A compact system using a folded light path with an air cooled argon laser for the light source was designed. A small, sensitive detector unit permits easy angular rotation for changing the scattering angle. A narrow detector field of view of + or - 1/4 degree of scattering along with a single wavelength of incident light is used to minimize uncertainties in the scattering theory. The system is automated for data acquisition of the scattering matrix elements over an angular range from 2 degrees to 178 degrees of scattering. Both laser output and detector sensitivity are monitored to normalize the measured light scattering.

Hansen, M. Z.↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Investigation of Impinging Stream Vortex Chamber Concepts for Liquid Rocket Engine Applications

This paper addresses the progress of technology development of a laser ignition system at NASA Marshall Spac Flight Center (MSFC). Initial hot-fire tests in a small-scale rocket chamber at MSFC have demonstrated the dual pulse laser-induced spark (DPLIS) technique, which has an advantage over existing single-pulse laser ignition techniques in that it can be optimized in its laser pulse format to maximize the initial plasma volume, the plasm: lifetime, as well as the flame kernel growth rate. The distribution of the total laser energy into two separate pulse also lowers the peak power that would need to be sent through fiber optics to the combustion chamber, making the implementation of this technique more practical than other single-pulse techniques. A first generation prototype of an optic fiber-coupled laser ignition system will be tested a rocket chamber with RP-1/GOX and GH2/GOX propellants systems. Other relevant technology, such as optical windows, flight-qualified laser system etc. will be discussed in this paper.

Trinh, Huu P.↗

Investigation of Superluminescent Diodes for Smart Lighting Systems. Final Report

The solid-state lighting ecosystem has evolved very rapidly over the last few years, with significant improvements in the technical performance of light-emitting diodes (LEDs) and the commoditization of LED-based lighting fixtures. As the performance of conventional lighting products begins to saturate, there is growing market interest in “Lighting as a Service” applications that will leverage advanced systems to impart new functionalities to lighting and improve energy efficiency, human health, and productivity. These “Smart Lighting” systems will include high-performance light sources, specialized sensors, and dynamic controls to deliver high quality, energy efficient, color tunable lighting with customized spatial light delivery and integrated visible light communication capability. To achieve these capabilities, smart lighting systems will place greater demands on the performance of light sources. Highly efficient sources with additional functionalities compared to conventional LEDs, such as small form factor, large modulation bandwidth, and spatially coherent output beams, will be required. While laser diodes have been proposed as potential sources for smart lighting systems, they also exhibit several properties that pose challenges, such as temporal coherence, extremely high spatial coherence, and ultra-narrow linewidths. To address these issues, we propose an investigation of an alternative device architecture known as a superluminescent diode (SLD). SLDs are similar in form to ridge laser diodes and share many of the same characteristics, such as stimulated emission operation, spatially coherent output, small form factor, and the potential for large modulation bandwidth. However, the operating principle for SLDs is distinct from laser diodes in that SLDs lack a strong cavity feedback mechanism, resulting in spatially coherent but temporally incoherent light output. Thus, SLDs may address the issues with laser diodes for lighting, while simultaneously maintaining some of the desirable characteristics of both laser diodes and LEDs. The objectives of this proposal are to design, grow, and fabricate blue (450 nm) SLDs on polar c-plane and nonpolar m-plane free-standing GaN substrates, and to evaluate their potential as sources in smart lighting systems through basic device characterization and detailed investigations of their efficiency droop and modulation bandwidth. The primary scientific aims of this work are to understand the fundamental role of optical gain in the superluminescent (non-lasing) regime on efficiency droop and modulation bandwidth in III-nitride emitters and to understand the effects of higher optical gain on SLD performance by comparing polar c-plane and nonpolar m-plane SLDs. The University of New Mexico (UNM) will collaborate with Sandia National Laboratories (SNL) and the Center for Integrated Nanotechnologies to design, fabricate, grow, and characterize the SLDs. UNM will perform the design and epitaxial growth, while SNL will focus on the fabrication and device characterization. The novelty of the proposed work includes the first comprehensive theoretical and experimental investigations of efficiency droop and the first investigation of modulation bandwidth in GaN-based emitters operating in the superluminescent regime. Moreover, the comparison of c-plane and m-plane SLDs will enable the first analysis of the effects of higher optical gain on the device performance. The development of high-performance GaN-based SLDs may enable efficiency gains and improved functionality in next-generation smart lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Diode Laser Velocity Measurements by Modulated Filtered Rayleigh Scattering

The ability of solid-state lasers to be tuned in operating frequency at MHz rates by input current modulation, while maintaining a relatively narrow line-width, has made them useful for spectroscopic measurements. Their other advantages include low cost, reliability, durability, compact size, and modest power requirements, making them a good choice for a laser source in micro-gravity experiments in drop-towers and in flight. For their size, they are also very bright. In a filtered Rayleigh scattering (FRS) experiment, a diode laser can be used to scan across an atomic or molecular absorption line, generating large changes in transmission at the resonances for very small changes in frequency. The hyperfine structure components of atomic lines of alkali metal vapors are closely spaced and very strong, which makes such atomic filters excellent candidates for sensitive Doppler shift detection and therefore for high-resolution velocimetry. In the work we describe here we use a Rubidium vapor filter, and work with the strong D(sub 2) transitions at 780 nm that are conveniently accessed by near infrared diode lasers. The low power output of infrared laser diodes is their primary drawback relative to other laser systems commonly used for velocimetry. However, the capability to modulate the laser frequency rapidly and continuously helps mitigate this. Using modulation spectroscopy and a heterodyne detection scheme with a lock-in amplifier, one can extract sub-microvolt signals occurring at a specific frequency from a background that is orders of magnitude stronger. The diode laser modulation is simply achieved by adding a small current modulation to the laser bias current. It may also be swept repetitively in wavelength using an additional lower frequency current ramp.

Mach, J. J.↗

The Effect of Laser Scan Strategy on Distortion and Residual Stresses of Arches Made With Selective Laser Melting

The NASA Marshall Space Flight Center (MSFC) is developing Additive Manufacturing (AM) - both in-space AM for on-demand parts, tools, or structures, and on-earth AM for rapid, reduced-cost, small volume production of complex space-flight hardware. Selective Laser Melting (SLM) is an on-earth AM technology that MSFC is using to build Alloy 718 rocket engine components. An understanding of the SLM-718 material properties is required to design, build, and qualify these components for space flight. Residual stresses and are of particular interest for this AM process, since SLM is a series of approximately 100 micron-wide welds, where highly non-linear heating and cooling, severe thermal gradients and repeated thermal cycling can result in high residual stresses within the component. These stresses may cause degraded material properties, and warp or distort the geometry of the SLM component. The distortions can render the component out-of-tolerance when inspected, and even interrupt or halt the build process if the warped material prevents the SLM machine from operating properly. The component must be scrapped and re-designed, which is time consuming and costly. If residual stresses are better understood, and can be predicted, these effects can be mitigated early in the component's design. the compressive residual stresses in the z-direction were highest in the chess sample, followed by island then continuous. This may be due to the binding nature of the segments

Bagg, Stacey D.↗

Expansion of the nickel electrode

To observe a reasonable amount of expansion, months or years in acutal batteries are required. Therefore, the technique of electrode bending was developed. Active material is taken off a sample electrode on one side, and left only on the other side with a cadmium counter electrode. With this configuration, if the active material expands, the electrode will bend convex - concave towards this direction. This very small bending may be easily detected with light deflection. A laser beam was used to project it on the screen through a mirror attached on the electrode, thus making a very sensitive measurement of a very small expansion.

Lim, H. S.↗