Search NASA⌕ Search

SEARCH · Search NASA

Results for “space heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Space shuttle: Aerodynamic heating tests of the MDAC delta wing orbiter and canard booster

Design of an efficient thermal protection system for the space shuttle orbiter and booster is discussed, based on knowledge of the thermal environment to be experienced by the vehicles in all flight phases. The complex configurations of these vehicles limit the level of confidence which can be associated with purely analytical thermal environment predictions. Tests were conducted during April and May 1971 using an orbiter and booster model at a 96-in. hypersonic shock tunnel. Both models were tested separately as well as together. A sufficiently large range in Reynolds number was covered so that laminar, transitional, and turbulent data could be obtained.

Andresen, T. L.↗

Evaluation of dispersion strengthened nickel-base alloy heat shields for space shuttle application

The design, fabrication, and testing of a full-size, full-scale TD Ni-20Cr heat shield test array in simulated mission environments is described along with the design and fabrication of two additional full-size, full-scale test arrays to be tested in flowing gas test facilities at the NASA Langley Research Center. Cost and reusability evaluations of TD Ni-20Cr heat shield systems are presented, and weight estimates of a TD Ni-20Cr heat shield system for use on a shuttle orbiter vehicle are made. Safe-line expectancy of a TD Ni-20Cr heat shield system is assessed. Non-destructive test techniques are evaluated to determine their effectiveness in quality assurance checks of TD Ni-20Cr components such as heat shields, heat shield supports, close-out panels, formed cover strips, and edge seals. Results of tests on a braze reinforced full-scale, subsize panel are included. Results show only minor structural degradation in the main TD Ni-20Cr heat shields of the test array during simulated mission test cycles.

Johnson, R., Jr.↗

Optimization of a heat-pipe-cooled space radiator for use with a reactor-powered Stirling engine

The design optimization of a reactor-Stirling heat-pipe-cooled radiator is presented. The radiator is a self-deploying concept that uses individual finned heat pipe 'petals' to reject waste heat from a Stirling engine. Radiator optimization methodology is presented, and the results of a parametric analysis of the radiator design variables for a 100-kW(e) system are given. The additional steps of optiminzing the radiator resulted in a net system mass savings of 3 percent.

Moriarty, Michael P.↗

Experimental aerodynamic heating to simulated space shuttle tiles in laminar and turbulent boundary layers with variable flow angles at a nominal Mach number of 7

The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally by using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold wall heating rate data for laminar and turbulent flow were obtained in the Langley 8 foot high Temperature Tunnel at a nominal Mach number of 7, a nominal total temperature of 3300R, a free stream unit Reynolds number from 3.4 x 10 sup 5 to 2.2 10 sup 6 per foot, and a free stream dynamic pressure from 2.1 to 9.0 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads. For the conditions of the present study, the results show that localized and total heating are sensitive to changes in flow angle only for the test conditions of turbulent boundary layer flow with high kinetic energy and that a flow angle from 30 deg to 50 deg will minimize the local heating.

Avery, D. E.↗

Direct contact droplet heat exchangers for thermal management in space

A liquid droplet heat exchanger for space applications is described which transfers heat between a gas and a liquid metal dispersed into droplets. The ability of the droplet heat exchanger to transfer heat between two media in direct contact over a wide temperature range circumvents many of the material limitations of conventional tube-type heat exchangers and does away with complicated plumbing systems and their tendency toward single point failure. Droplet heat exchangers offer large surface to volume ratios in a compact geometry, very low gas pressure drop, and high effectiveness. The application of the droplet heat exchanger in a high temperature Brayton cycle is discussed to illustrate its performance and operational characteristics.

Bruckner, A. P.↗

An attempt to remotely sense from space the surface heat budget over the Indian Ocean during the 1979 monsoon

Satellite data are used to estimate the net surface heat flux (Q) over the Indian Ocean during June 1979. Ten-day and monthly average fields of Q and its components are produced and analyzed in relation to monsoon dynamics. When compared to ship-based estimates, the satellite-derived fluxes exhibit correct orders of magnitude and their temporal evolution is consistent with the present monsoon knowledge. This study, which represents a first attempt to remotely sense from space the earth surface net heat flux, demonstrates that current satellite sensor data can be combined to accurately describe net heat flux changes in areas such as the Arabian Sea, where they are large, rapid, and spatially extended, and therefore not fully observed by ships.

Gautier, Catherine↗

Heat pipes in space: A NASA summary

Experiences derived from the development, integration, and flight of NASA spacecraft and sounding rockets are presented. They include the International Heat Pipe Experiment, OAO 3, and ATS-6. Typical flight data are presented to show the performance.

Ollendorf, S.↗

Heat pipe system for Space Shuttle TWTA.

Description of the design of a heat pipe system built to dissipate and reject the waste heat from the Space Shuttle communications implementing traveling-wave tube amplifier (TWTA). The heat pipe system proved itself as an effective tool for TWTA thermal control.

Basiulis, A.↗

Prediction modeling of physiological responses and human performance in the heat with application to space operations

This institute has developed a comprehensive USARIEM heat strain model for predicting physiological responses and soldier performance in the heat which has been programmed for use by hand-held calculators, personal computers, and incorporated into the development of a heat strain decision aid. This model deals directly with five major inputs: the clothing worn, the physical work intensity, the state of heat acclimation, the ambient environment (air temperature, relative humidity, wind speed, and solar load), and the accepted heat casualty level. In addition to predicting rectal temperature, heart rate, and sweat loss given the above inputs, our model predicts the expected physical work/rest cycle, the maximum safe physical work time, the estimated recovery time from maximal physical work, and the drinking water requirements associated with each of these situations. This model provides heat injury risk management guidance based on thermal strain predictions from the user specified environmental conditions, soldier characteristics, clothing worn, and the physical work intensity. If heat transfer values for space operations' clothing are known, NASA can use this prediction model to help avoid undue heat strain in astronauts during space flight.

Pandolf, Kent B.↗

Artemis I Space Launch System Base Heat Shield Thermal Protection System Performance

The Space Launch System (SLS) Core Stage base heat shield experienced the highest external heating environments on the entire launch vehicle during Artemis I ascent flight. This result was consistent with design predictions. The base heat shield experiences P50 cork combustion dynamics at low altitudes, plume-induced recirculation at moderate altitudes and then in-space base flow physics out to Main Engine Cut-Off (MECO). The base heat shield thermal protection system (TPS) is composed of a P50 cork ablator which is bonded to a substrate. The heat shield protects the gimbal actuation system, RS-25 turbomachinery systems and other aft section sensitive components during ascent. This paper estimates the base heat shield TPS performance from Artemis I using flight data from the NASA Langley Research Center’s Scientifically Calibrated In-Flight Imagery (SCIFLI) Airborne Multispectral Imager (SAMI), development flight instrumentation (DFI) and other TPS recession flight measurements. Predictions from computational and ground test-derived engineering ablation models and observations are also applied. Since no base heat shield substrate thermocouple data were obtained for Artemis I, an estimate of the TPS performance data is derived here. This data assesses thermal margin of the SLS Core Stage base heat shield and best informs the Artemis II Crewed mission to the moon.

aerothermodynamics↗

SSV Generic OFT first stage ascent base convective heating environments

Space Shuttle Vehicle (SSV) base convective heating environments during the recirculated flow time segment of first stage ascent were determined for the Generic OFT trajectory and performance conditions. These environments are presented in the attachments as cold wall convective heat transfer coefficients for individual or groups of design points for all affected SSV base surfaces. Two gas recovery temperatures applicable to upper and lower base region surfaces are also included. The environments were based upon magnitudes and trends from analysis of data taken during Base Heating Tests IH-39, IH-75, and IH-83. The plume heating trajectory and performance data were supplied by Rockwell International for both the OFT-1 Generic Mission A and Mission C.

Bender, R. L., Jr.↗

Space Launch System Base Heating Test: Experimental Operations & Results

NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Test methodology and conditions are presented, and base heating results from 76 runs are reported in non-dimensional form. Regions of high heating are identified and comparisons of various configuration and conditions are highlighted. Base pressure and radiometer results are also reported.

Dufrene, Aaron↗