Progress on Frequency-Domain Multiplexing Development for High Count rate X-ray Microcalorimeters

Frequency-domain multiplexing is one of the candidates for the readout of TES-based imaging microcalorimeter arrays for applications such as IXO. The readout system uses the TES as the modulating element, a bandpass LC filter to separate the signals in frequency space, and a customized SQUID with a low input inductance and high dynamic range as cryogenic amplifier. We will show the latest experimental progress on the development of this system. The paper concentrates on our first results on multiplexing 2-7 channels at bias frequencies below 5 MHz using discrete LC filters and baseband feedback electronics. In addition to that, the scalability of the system will be addressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance test of Ti/Au bilayer TES microcalorimeter in combination with continuous ADR

Performance test of a Ti/Au bilayer TES microcalorimeter has been made in combination with a continuous adiabatic demagnetization refrigerator (CADR). The CADR has four stages of ADR to produce continuous cooling by recycling them in dedicated order, and is cryogen-free utilizing a 4K-GM refrigerator. We installed a Ti/Au bilayer TES microcalorimeter and 420-series SQUID array to readout the X-ray signal on the 1st (coldest) stage of the CADR. We successfully operated the CADR at temperature of 120 mK in continuous mode more than 27 hr, however, FWHM energy resolution of the TES microcalorimeter was degraded to 45 eV at 6 keV, as compared to 10 eV when measured in a dilution refrigerator. This is mainly because the temperature stability was not good enough (about 0.6 mK) and the operation temperature was not sufficiently lower than the transition temperature T{sub c} = 135mK of the TES. We operated the TES microcalorimeter at the operation temperature of 105 mK in one-shot mode and the resolution was improved to 30 eV. We also found that the operating point of the TES was affected by the magnetic field of the 3rd and 4th ADR recycle. More complete shielding of the magnetic field is essential for further improvement of the performance of the TES microcalorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metallic magnetic calorimeters

Metallic magnetic calorimeters (MMC) are calorimetric particle detectors, typically operated at temperatures below 100 mK, that make use of a paramagnetic temperature sensor to transform the temperature rise upon the absorption of a particle in the detector into a measurable magnetic flux change in a dc-SQUID. During the last years a growing number of groups has started to develop MMC for a wide variety of applications, ranging from alpha-, beta- and gamma-spectrometry over the spatially resolved detection of accelerated molecule fragments to arrays of high resolution x-ray detectors. For x-rays with energies up to 6 keV an energy resolution of 2.7 eV (FWHM) has been demonstrated and we expect that this can be pushed below 1 eV with the next generation of devices. We give an introduction to the physics of MMCs and summarize the presently used readout schemes as well as the typically observed noise contributions and their impact on the energy resolution. We discuss general design considerations, the micro-fabrication of MMCs and the performance of micro-fabricated devices. In this field large progress has been achieved in the last years and the thermodynamic properties of most materials approach bulk values allowing for optimal and predictable performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microcalorimeter Magnetic Sensor Geometries Using Superconducting Elements

We describe a numerical code developed to estimate performance of magnetic microcalorimeter configurations, including superconducting elements and SQUID characteristics. We present results of a preliminary design analysis showing that composite sensors with both superconducting and paramagnetic elements should realize substantial gains in magnetic flux signal per magnetization change of the paramagnet, compared to sensors containing only paramagnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous Thermal Behavior in Microcalorimeter Gamma-Ray Detectors

Improving the resolution of gamma-ray detectors is important for many fields, including determinations of the Lamb shift in atoms with high atomic numbers, nuclear treaty verification, and environmental monitoring. High-purity germanium detectors are currently the tool of choice for precision gamma-ray spectroscopy. The resolution of these detectors is limited to about 500 eV full-width-at-half-maximum at 100 keV by Fano statistics. In comparison, low-temperature microcalorimeters can provide over an order of magnitude improvement in photon resolution. For instance, a gamma-ray microcalorimeter has achieved 25 eV FWHM resolution at 103 keV. These calorimeters consist of two components, a bulk absorber to stop incident gamma rays and a thermometer made from a thin film electrically biased in the superconducting-to-normal phase transition, called a Transition Edge Sensor, or TES. The standard absorber is bulk, superconducting tin. While tin has historically been the best performing absorber, pulse decays in Sn devices are much slower than predicted. We have begun a systematic study of absorber behavior in order to assess and improve response times. This study leverages two capabilities: the ability to microfabricate highly uniform arrays of gamma-ray detectors and the ability to read out many detectors in a single cool-down using SQUID multiplexer circuits. Here, we present two experiments to identify the source of thermal time constants. The first involves varying properties of the Sn absorber including purity, vendor, and crystal grain size. The second examines the role of the other elements in the microcalorimeter assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The X-Ray Microcalorimeter Spectrometer for the International X-Ray Observatory

The International X-Ray Observatory (IXO) is under formulation by NASA, ESA and JAXA for deployment in 2022. IXO emerged over the last 18 months as the NASA Constellation-X and ESA/JAXA X-Ray Evolving Universe Spectrometer (XEUS) missions were combined. The driving performance requirements for the X-Ray Microcalorimeter Spectrometer (XMS) are a spectral resolution of 2.5 eV over the central 2'x2' in the 0.3-7.0 keV band, and 10 eV to the edge of the 5'x5' field of view (FOV). The XMS is now based on a microcalorimeter array of Transition-Edge Sensor (TES) thermometers with Au/Bi absorbers and a SQUID MUX readout. One of the concepts studied as part of the mission formulation has a core 40x40 array corresponding to a 2'x2' FOV with 3'' pixels surrounded by an outer, annular 52x52 array of 6'' pixels that extends the field of view to 5.4'x5.4' with better than 10 eV resolution. There are several options for implementing the readout and cooling system of the XMS under study in the US, Europe and Japan. The ADR system will have from two to five stages depending on the performance of the cryocooler. Mechanical coolers with sufficient cooling power at 4K are available now, and {approx}2K coolers are under development. In this paper we give an overview of the XMS instrument, and some of the tradeoffs to be addressed for this observatory instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADMX Phase II : Relocation and Millikelvin Cooling

Low mass axions are an attractive candidate for making up dark matter. While there are several models for how the Axion couples with other matter, were they to be the majority of the local galactic dark matter halo, they would have a number density on the order of 10{sup 14} cm{sup -3}. The Axion Dark Matter eXperiment (ADMX) is a microwave cavity experiment searching for axion Dark Matter via the axion's electromagnetic coupling. While the original ADMX did not see evidence of axions, the experiment is planned to go through two phases of upgrades to expand its sensitivity and provide a definitive search for axion dark matter. The first phase established the use of a SQUID amplifier which can reduce the amplifier noise temperature to the 100 mK range. In the second phase we will first move the experiment from LLNL to CENPA at the University of Washington. Once the experiment has been moved successfully we will install a dilution refrigerator to cool the cavity to the 100 mK range thus increasing the sensititivity to the level required to scan the remainder of the allowed model space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contribution to the Study of Ferrite Nanobeads: Synthesis, Characterization and Investigation of Horizontal Low Gradient Magnetophoresis Behaviour

In this work we investigate the possibilities of the use of Horizontal Low Gradient Magnetic Field (HLGMF)(<100 T/m) for filtration, control and separation of the synthesized magnetic particles, considering, the characteristics of the suspension, the size and the type of nanoparticles (NPs) and focusing on the process scale up. Reversible aggregation is considered in the different steps of magnetic nanobeads synthesis. For these purpose, we synthesized Fe{sub 2}O{sub 3}-silica core-shell nanobeads by co-precipitation, monodispersion and silica coating. SQUID, TEM, XRD, and Zeta potential techniques were used to characterize the synthesized nanobeads. An extensive magnetophoresis study was performed at different magnetophoretic conditions. Different reversible aggregation times were observed at different HLGMF, at each step of the synthesis route: Several orders of magnitude differences where observed when comparing citric acid (CA) suspension with silicon coated beads. Reversible aggregation times are correlated with the properties of the NPs at different steps of synthesis.

36 MATERIALS SCIENCE↗

Moessbauer spectroscopy and magnetic characteristics of Zn{sub 1-x}Co{sub x}Fe{sub 2}O{sub 4} (x = 0-1) nanoparticles

Zn{sub 1-x}Co{sub x}Fe{sub 2}O{sub 4} (x = 0-1 in a step of 0.2) nanoparticles with different range of particle size including 5-10 nm and 200-250 nm have been prepared by sol-gel process. Moessbauer spectra at room temperature indicated that, with increasing cobalt content, there is a transition from paramagnetic to magnetically ordered-ferrimagnetic state. Magnetic properties were measured at 300 and 10 K using a Quantum Design MPMS-5S SQUID magnetometer. It was found that with an increase in cobalt content the saturation magnetization and coercivity increase.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic properties of MnSb inclusions formed in GaSb matrix directly during molecular beam epitaxial growth

Despite of intensive search for the proper semiconductor base materials for spintronic devices working at room temperature no appropriate material based on ferromagnetic semiconductors has been found so far. We demonstrate that the phase segregated system with MnSb hexagonal inclusions inside the GaSb matrix, formed directly during the molecular beam epitaxial growth reveals the ferromagnetic properties at room temperature and is a good candidate for exploitation in spintronics. Furthermore, the MnSb inclusions with only one crystalline structure were identified in this GaMn:MnSb granular material. The SQUID magnetometry confirmed that this material exhibits ferromagnetic like behavior starting from helium up to room temperature. Moreover, the magnetic anisotropy was found which was present also at room temperature, and it was proved that by choosing a proper substrate it is possible to control the direction of easy axis of inclusions' magnetization moment between in-plane and out-of-plane; the latter is important in view of potential applications in spintronic devices.

36 MATERIALS SCIENCE↗

Cu-doped AlN: A possible spinaligner at room-temperature grown by molecular beam epitaxy?

Cu-doped AlN was prepared by plasma assisted molecular beam epitaxy on C-plane sapphire substrates. The growth conditions were investigated for different Cu to Al flux ratios from 1.0% to 4.0%. The formation of Cu-Al alloys on the surface was observed for all doping level. In contrast to Cu-doped GaN, all samples showed diamagnetic behavior determined by SQUID measurements.

36 MATERIALS SCIENCE↗

Aligned and exchange-coupled L1{sub 0} (Fe,Co)Pt-based magnetic films

Films of aligned L1{sub 0}-structure (Fe,Co)Pt with fcc Fe(Co,Pt) are synthesized by co-sputtering Fe, Co, and Pt on an (001) MgO substrate with in situ heating at 830 deg. C. The nanostructures and magnetic properties of the films are characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), and superconducting quantum interference device (SQUID). The compositions of the samples (Fe,Co){sub x}Pt{sub 1-x} are designed to maintain an atomic Fe: Co ratio of 65: 35 while increasing the Fe,Co content in each successive sample. In samples with low Fe and Co concentration, the XRD patterns exhibit three strong peaks, namely L1{sub 0} (Fe,Co)Pt (001), L1{sub 0} (Fe,Co)Pt (002), and MgO (002). A fourth peak is observed in samples with high Fe and Co concentration and identified as fcc (002). The XRD patterns confirm the formation of L1{sub 0}-ordered (Fe,Co)Pt and its epitaxial growth on MgO. TEM shows that the (Fe,Co)Pt films form isolated magnetic grains of about 100 nm in diameter. Hysteresis-loop measurements show that the increase of the Fe,Co concentration from 57.3 to 68.3 at % enhances the saturation magnetization M{sub s} from 1245 emu/cm{sup 3} to 1416 emu/cm{sup 3}, and the coercivity decreases from 32 kOe to 8.9 kOe. The nominal maximum energy product per grain is 64 MGOe.

36 MATERIALS SCIENCE↗

Ion beam induced effects on the ferromagnetism in Pd nanoparticles

Present study demonstrates the role of metal-insulator interface and ion irradiation induced defects on the ferromagnetic properties of the non-magnetic materials. Magnetic properties of the Pd nanoparticles(NPs) embedded in the a-silica matrix synthesized using atom beam sputtering technique, were determined using SQUID magnetometry measurements which showed that ferromagnetic response of Pd increased by 3.5 times on swift heavy ion(SHI) irradiation. The ferromagnetic behavior of the as-deposited Pd NPs is due to strain induced by the surrounding matrix and modification in the electronic structure at the Pd-silica interface as revealed by insitu XRD and XPS investigations, respectively. The defects created by the SHI bombardment are responsible for enhancement of the magnetization in the Pd NPs.

36 MATERIALS SCIENCE↗

Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed, and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence of martensitic phase transitions in magnetic Ni-Mn-In thin films

Ni{sub 50}Mn{sub 35}In{sub 15} Heusler alloy thin films (with thicknesses of about 10 nm) have been grown on single crystal MgO and SrTiO{sub 3} (STO) (100) substrates using a laser-assisted molecular beam epitaxy method. Films of mixed austenitic and martensitic phases and of pure martensitic phase have been detected for those grown on MgO and STO substrates, respectively. Thermomagnetic curves were measured using a SQUID magnetometer and are consistent with those of off-stoichiometric In-based bulk Heusler alloys, including a martensitic transition at T = 315 K for films grown on MgO. The differences in the properties of the films grown on MgO and STO are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental and first-principles study of ferromagnetism in Mn-doped zinc stannate nanowires

Room temperature ferromagnetism was observed in Mn-doped zinc stannate (ZTO:Mn) nanowires, which were prepared by chemical vapor transport. Structural and magnetic properties and Mn chemical states of ZTO:Mn nanowires were investigated by X-ray diffraction, superconducting quantum interference device (SQUID) magnetometry and X-ray photoelectron spectroscopy. Manganese predominantly existed as Mn{sup 2+} and substituted for Zn (Mn{sub Zn}) in ZTO:Mn. This conclusion was supported by first-principles calculations. Mn{sub Zn} in ZTO:Mn had a lower formation energy than that of Mn substituted for Sn (Mn{sub Sn}). The nearest neighbor Mn{sub Zn} in ZTO stabilized ferromagnetic coupling. This observation supported the experimental results.

36 MATERIALS SCIENCE↗

Tunable microwave impedance matching to a high impedance source using a Josephson metamaterial

We report the efficient coupling of a 50 Ω microwave circuit to a high impedance conductor. We use an impedance transformer consisting of a λ/4 co-planar resonator whose inner conductor contains an array of superconducting quantum interference devices (SQUIDs), providing it with a tunable lineic inductance L∼80 μ{sub 0}, resulting in a characteristic impedance Z{sub C}∼1 kΩ. The impedance matching efficiency is characterized by measuring the shot noise power emitted by a dc biased tunnel junction connected to the resonator. We demonstrate matching to impedances in the 15 to 35 kΩ range with bandwidths above 100 MHz around a resonant frequency tunable between 4 and 6 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Band-structure analysis from photoreflectance spectroscopy in (Ga,Mn)As

Modulation photoreflectance spectroscopy has been applied to study the band-structure evolution in (Ga,Mn)As epitaxial layers with increasing Mn content. Structural and magnetic properties of the layers were characterized with high-resolution X-ray diffractometry and SQUID magnetometery, respectively. The revealed results of decrease in the band-gap-transition energy in the (Ga,Mn)As layers with increasing Mn content are interpreted in terms of a disordered valence band, extended within the band gap, formed, in highly Mn-doped (Ga,Mn)As, as a result of merging the Mn-related impurity band with the host GaAs valence band.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗