Search NASA⌕ Search

SEARCH · Search NASA

Results for “steam data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Qualification of the Nippon Instrumentation for use in Measuring Mercury at the Defense Waste Processing Facility

The Nippon Mercury/RA-3000 system installed in 221-S M-14 has been qualified for use. The qualification was a side-by-side comparison of the Nippon Mercury/RA-3000 system with the currently used Bacharach Mercury Analyzer. The side-by-side testing included standards for instrument calibration verifications, spiked samples and unspiked samples. The standards were traceable back to the National Institute of Standards and Technology (NIST). The side-by-side work included the analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt, SRAT Product, and Slurry Mix Evaporator (SME) samples. With the qualification of the Nippon Mercury/RA-3000 system in M-14, the DWPF lab will be able to perform a head to head comparison of a second Nippon Mercury/RA-3000 system once the system is installed. The Defense Waste Processing Facility (DWPF) analyzes receipt and product samples from the Sludge Receipt and Adjustment Tank (SRAT) to determine the mercury (Hg) concentration in the sludge slurry. The SRAT receipt is typically sampled and analyzed for the first ten SRAT batches of a new sludge batch to obtain an average Hg concentration. This average Hg concentration is then used to determine the amount of steam stripping required during the concentration/reflux step of the SRAT cycle to achieve a less than 0.6 wt% Hg in the SRAT product solids. After processing is complete, the SRAT product is sampled and analyzed for mercury to ensure that the mercury concentration does not exceed the 0.45 wt% limit in the Slurry Mix Evaporator (SME). The DWPF Laboratory utilizes Bacharach Analyzers to support these Hg analyses at this facility. These analyzers are more than 10 years old, and they are no longer supported by the manufacturer. Due to these difficulties, the Bacharach Analyzers are to be replaced by new Nippon Mercury/RA-3000 systems. DWPF issued a Technical Task Request (TTR) for the Savannah River National Laboratory (SRNL) to assist in the qualification of the new systems. SRNL prepared a task technical and quality assurance (TT&QA) plan that outlined the activities that are necessary and sufficient to meet the objectives of the TTR. In addition, TT&QA plan also included a test plan that provided guidance to the DWPF Lab in collecting the data needed to qualify the new Nippon Mercury/RA-3000 systems.

47 OTHER INSTRUMENTATION↗

Anomalous aging of EPDM and FEPM under combined thermo-oxidative and hydrolytic conditions

Previous observation of EPDM and FEPM materials aged in thermo-oxidative and thermo-oxidative plus hydrolytic environments revealed an unusual trend: the degradation and disintegration of these polymers in the former case but the ability to maintain mechanical performance and shape in the latter [1]. No abnormalities were observed in the chemical (oxidation rates, FTIR spectra, solvent uptake, gel content, and weight loss vs. temperature) or physical (modulus profile) measurements that could explain these empirically observed aging differences. A second controlled aging test was conducted to verify this trend using only EPDM. Once again it was shown that thermo-oxidative conditions appear to cause more degradative damage (enhanced embrittlement) than observed for the combined thermo-oxidative plus hydrolytic environments. From these data we conclude that water may favorably interfere with normal thermo-oxidative degradation processes. This interference may occur via some combination of chemical and physical property changes in the presence of steam such as: oxidation rate and O2 permeability changes, additional sensitivity to hydrolytic damage, and/or mechanistic changes in relation to pH and hydroperoxide formation.

15 GEOTHERMAL ENERGY↗

Using onset times from frequent seismic surveys to understand fluid flow at the Peace River Field, Canada

With our limited knowledge of the relationship between changes in the state of an aquifer or reservoir and the corresponding changes in the elastic moduli, that is the rock physics model, hampers the effective use of time-lapse seismic observations for estimating flow properties within the Earth. A central problem is the complicated dependence of the magnitude of time-lapse changes on the saturation, pressure, and temperature changes within an aquifer or reservoir. We describe an inversion methodology for reservoir characterization that uses onset times, the calendar time of the change in seismic attributes, rather than the magnitude of the changes. We find that onset times are much less sensitive than magnitudes to the rock physics model used to relate time-lapse observations to changes in saturation, temperature and fluid pressure. We apply the inversion scheme to observations from daily monitoring of enhanced oil recovery at the Peace River field in Canada. An array of 1492 buried hydrophones record seismic signals from 49 buried sources. Time-shifts for elastic waves traversing the reservoir are extracted from the daily time-lapse cubes. In our analysis 175 images of time-shifts are transformed into a single map of onset times, leading to a substantial reduction in the volume of data. These observations are used in conjunction with bottom hole pressure data to infer the initial conditions prior to the injection, and to update the reservoir permeability model. The combination of a global and local inversion scheme produces a collection of reservoir models that are best described by three clusters. The updated model leads to a nearly 70 percent reduction in seismic data misfit. The final set of solutions successfully predict the observed normalized pressure history during the soak and flow-back into the wells between 82 and 175 days into the cyclic steaming operation.

58 GEOSCIENCES↗

Scaling Outlooks on Integrated Energy Systems

The report provides research summaries of two developed theories: data projection to enable multi-scale facility digital interactions and introducing the Evaluation Model Development and Assessment Process (EMDAP) approach to Integrated Energy Systems (IES) design. For the data projection, a two-system scaling case including interactions between thermal storage and hydrogen production is provided. The corresponding facilities are the thermal energy distribution system (TEDS) facility and high temperature steam electrolysis (HTSE) facility at the Dynamic Energy Transport and Integration Laboratory (DETAIL) in Idaho National Laboratory (INL). For the EMDAP adaption to system design, a modified process of the EMDAP was developed and applied to indirect two-tank heat storage system design. System phenomena were identified, ranked, and scaled to discover helpful key relations that would determine the ideal component geometry.

08 HYDROGEN↗

Jay Carter Enterprises, Incorporated steam engine

The Small Community Solar Thermal Power Experiment (SCSE) selected an organic rankine cycle (ORC) engine driving a high speed permanent magnet alternator (PMA) as the baseline power conversion subsystem (PCS) design. The back-up conceptual PCS design is a steam engine driving an induction alternator delivering power directly to the grid. The development of the automotive reciprocating simple rankine cycle steam engine and how an engine of similar design might be incorporated into the SCSE is discussed. A description of the third generation automotive engine is included along with some preliminary test data. Tests were conducted with the third generation engine driving an induction alternator delivering power directly to the grid. The purpose of these tests is to further verify the effects of expander inlet temperature, input thermal power level, expansion ratio, and other parameters affecting engine performance to aid in the development of an SCSE PCS.

Source record↗

The small community solar thermal power experiment. Parabolic dish technology for industrial process heat application

Aspects of incorporating a thermal energy transport system (ETS) into a field of parabolic dish collectors for industrial process heat (IPH) applications were investigated. Specific objectives are to: (1) verify the mathematical optimization of pipe diameters and insulation thicknesses calculated by a computer code; (2) verify the cost model for pipe network costs using conventional pipe network construction; (3) develop a design and the associated production costs for incorporating risers and downcomers on a low cost concentrator (LCC); (4) investigate the cost reduction of using unconventional pipe construction technology. The pipe network design and costs for a particular IPH application, specifically solar thermally enhanced oil recovery (STEOR) are analyzed. The application involves the hybrid operation of a solar powered steam generator in conjunction with a steam generator using fossil fuels to generate STEOR steam for wells. It is concluded that the STEOR application provides a baseline pipe network geometry used for optimization studies of pipe diameter and insulation thickness, and for development of comparative cost data, and operating parameters for the design of riser/downcomer modifications to the low cost concentrator.

Polzien, R. E.↗

Life-cycle analysis of recycling of post-use plastic to plastic via pyrolysis

Advanced recycling enables the application of post-use plastics (PUP) to produce valuable industrial chemicals and develop markets for recycled feedstocks. Pyrolysis is one of the most common advanced recycling technologies undergoing industrial-scale implementation for converting PUP. This paper presents a life cycle analysis (LCA) to assess greenhouse gas (GHG) emissions, fossil energy, water consumption, and solid waste impacts of converting PUP into new plastics such as high-density and low-density polyethylene (HDPE and LDPE, respectively). Data was collected from eight plastic pyrolysis companies. This study addresses the impacts of pyrolysis plant size and maturity; two substitution rate (SR) cases of pyrolysis oil with fossil-derived feedstocks in steam crackers (5% and a 20% of pyrolysis oil SR); and potentially avoided emissions from traditional end-of-life (EOL) management. Because the conventional feedstock slate of steam crackers in the Unites States is comprised of 94% gases (a mix of ethane, propane, and butane) and 6% naphtha, the 5% SR case looked at polyethylene (PE) derived from 5% pyrolysis oil, 1% naphtha, and 94% gases; while the 20% SR looked at PE derived from 20% pyrolysis oil and 80% gases. Moreover, the results are presented from two perspectives: 1) steam crackers' and 2) plastic recyclers'. In the recyclers' perspective, the results for the 5% SR showed for each kg of PUP used there was a 23% and 18% decrease in GHG emissions for HDPE and LDPE respectively, while the 20% SR showed a 4% and 3% reduction in GHG emissions for HDPE and LDPE respectively compared to virgin plastic. The 20% SR has lower GHG emissions reductions because there is an added step of hydrotreating the pyrolysis oil to remove chlorine concentrations that is not included in the 5% SR scenario. Furthermore, the 5% SR removes most of the naphtha, a more carbon intense feedstock, and replaces it with PUP-based pyrolysis oil, a less carbon intense feedstock. GHG emissions for PUP pyrolysis could be further reduced by 50% and 131% in the United States and European Union respectively if the GHG emissions of current PUP incineration practices were considered as emission reductions credits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Data Reconciliation and Validation of a Dynamic Model for Solvent-Based CO 2 Capture Using Pilot-Plant Data

This paper is focused on the development and validation of a dynamic model for an MEA-based CO 2 capture unit. Starting with a rigorous steady-state process model, the dynamic model is developed in Aspen Plus Dynamics ® using a modified Murphree-efficiency approach and is validated using dynamic data collected from the National Carbon Capture Center (NCCC) in Wilsonville, Alabama. The dynamic test runs were designed with due consideration of process excitation and process nonlinearities constrained by the available time to conduct the test runs and implement the experimental designs in the plant control system. The experimental data include solvent composition and loading. Since the experimental data were found to violate mass and energy balances, filtering algorithms coupled with dynamic data reconciliation techniques were used. Without adjusting any model parameters, the dynamic model satisfactorily predicted dynamic response of CO 2 capture due to step changes in the solvent flowrate, flue gas flowrate, and steam flowrates. Transient studies show that the process gain and time constants can considerably change depending on the direction of the disturbance or manipulated variables, indicating process nonlinearities. Due to a storage tank between the absorber and stripper, the time constant of the full plant can be considerably longer than the time constants of the absorber or stripper individually. Furthermore, impact of the control system on the process efficiency while following an optimal CO 2 capture schedule was also studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SINGLE PHASE ANALYTICAL MODELS FOR TERRY TURBINE NOZZLE

All BWR RCIC (Reactor Core Isolation Cooling) systems and PWR AFW (Auxiliary Feed Water) systems use Terry turbine, which is composed of the wheel with turbine buckets and several groups of fixed nozzles and reversing chambers inside the turbine casing. The inlet steam is accelerated through the turbine nozzle and impacts on the wheel buckets, generating work to drive the RCIC pump. As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC systems in Fukushima accidents and extend BWR RCIC and PWR AFW operational range and flexibility, mechanistic models for the Terry turbine, based on Sandia National Laboratories’ original work, has been developed and implemented in the RELAP-7 code to simulate the RCIC system. RELAP-7 is a new reactor system code currently under development with the funding support from U.S. Department of Energy. The RELAP-7 code is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear system. This paper presents a set of analytical models for simulating the flow through the Terry turbine nozzles when inlet fluid is pure steam. The implementation of the models into RELAP-7 will be briefly discussed. In the Sandia model, the turbine bucket inlet velocity is provided according to a reduced-order model, which was obtained from a large number of CFD simulations. In this work, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine bucket inlet. The models include both adiabatic expansion process inside the nozzle and free expansion process out of the nozzle to reach the ambient pressure. The combined models are able to predict the steam mass flow rate and supersonic velocity to the Terry turbine bucket entrance, which are the necessary input conditions for the Terry Turbine rotor model. The nozzle analytical models were validated with experimental data and benchmarked with CFD simulations. The analytical models generally agree well with the experimental data and CFD simulations. The analytical models are suitable for implementation into a reactor system analysis code or severe accident code as part of mechanistic and dynamical models to understand the RCIC behaviors. The cases with two-phase flow at the turbine inlet will be pursued in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrity Assessment of Hanford 242-A Evaporator Facility E-A-1 Re-boiler Vessel via Fluorescein Liquid Tracer Test Methods - 17357

The 242-A Evaporator Facility is critical to the United States Department of Energy's (DOE) Hanford Site clean-up mission due to limited space within the existing Double-Shell Tanks (DSTs) used to store nuclear and chemical waste until future processing. The 242-A Evaporator Facility is currently the sole waste volume reduction process used at Hanford, and the E-A-1 Re-boiler is essential to the Evaporator process. Due to the potential for cross-contamination between the Re-boiler tubes through which waste passes and the tube sheets of uncontaminated steam, an assessment of the Re-boiler vessel's integrity is required for continuing operations of the facility. In order to meet these requirements, an independent integrity assessment was designed to use fluorescein liquid tracer (LT) to verify the leak-tightness of the Re-boiler vessel in accordance with Washington River Protection Solutions, LLC (WRPS) tightness test standards, as well as, the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 1, NB-6300. LT test methodologies were evaluated and determined to be appropriate for a vessel with restricted access, such as the E-A-1 Re-boiler, as it provided the needed sensitivity, reliability, and cost; as well as, exceeded the leak-tightness specifications required by both WRPS and ASME B and PV Code standards. The integrity test requires water laced with fluorescein be circulated through the waste processing loop of the 242-A Evaporator and samples of steam condensate be collected and analyzed for traces of fluorescein to determine leak-tightness. Liquid condensate sampling was conducted prior to and during testing and the samples were analyzed for fluorescein tracer to determine the amount of fluorescein that flowed out of the tubes of the Re-boiler into the steam side of the vessel. Given the established criteria for 'leak-tight,' test results determined that the Re-boiler passed the integrity assessment. After further scrutiny of the 2014 test and data results, it was determined that although the Re-boiler was 'leak-tight,' as established by the test criteria, there was concern of future leakage. The DOE and the DOE Office of River Protection (ORP) requested that WRPS repeat the integrity assessment in two and a half years to determine if the potential leak was growing, which could threaten continuing operations of the 242-A Evaporator. The 2017 test has been redesigned using lessons learned from the 2014 test and was modified to account for ergonomic and safety considerations, ease of repeatability, and accuracy of results. The liquid tracer methodology and test plan developed for the Re-boiler will continue to be implemented in 5 year increments to monitor current and future integrity. The method may also prove useful for other aging components across the Hanford Site, where appropriate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flow instabilities in helical-coil steam generators for small modular reactors: A review

Here, this study covers the research and discoveries in two-phase flow-boiling instabilities available in the literature—specifically for a helical-coil steam generator (HCSG), including experimental findings, theoretical research, computational models, and system code analyses—supporting research and development of representative small modular reactors (SMRs). Like other new and advanced reactor systems, water-cooled SMRs require experimental data from both integral and separate thermal-hydraulics test facilities for the verification and validation (V&V) of the computational models and computer codes in order to design and obtain regulatory approval. The complex dynamics of two-phase flow-boiling instabilities includes flow regimes physics phenomena, flow-channel geometries, heat-transfer behavior, and interactions among the solid–liquid-gas within the system boundary, all of which are pivotal for understanding the design and operational challenges of SMRs. This study focuses on identifying the relevant knowledge gaps on boiling instabilities—specifically for a HCSG—and provides insights about future research direction optimizing the transport of thermal energy, mass-flow rates, and boundary conditions that ensure the adequate heat-transfer performance, operational stability, and safety associated with SMR systems.

20 FOSSIL-FUELED POWER PLANTS↗

Underground coal gasification using oxygen and steam

In this paper, through model experiment of the underground coal gasification, the effects of pure oxygen gasification, oxygen-steam gasification, and moving-point gasification methods on the underground gasification process and gas quality were studied. Experiments showed that H{sub 2} and CO volume fraction in product gas during the pure oxygen gasification was 23.63-30.24% and 35.22-46.32%, respectively, with the gas heating value exceeding 11.00 MJ/m{sup 3}; under the oxygen-steam gasification, when the steam/oxygen ratio stood at 2: 1, gas compositions remained virtually stable and CO + H{sub 2} was basically between 61.66 and 71.29%. Moving-point gasification could effectively improve the changes in the cavity in the coal seams or the effects of roof inbreak on gas quality; the ratio of gas flowing quantity to oxygen supplying quantity was between 3.1:1 and 3.5:1 and took on the linear changes; on the basis of the test data, the reasons for gas quality changes under different gasification conditions were analyzed.

01 COAL, LIGNITE, AND PEAT↗

Modeling of On-Cell Reforming Reaction for Planar SOFC Stacks

Planar Solid Oxide Fuel Cell (SOFC) stack is known to suffer thermal problem from high stack temperature during operation to generate high current. On-Cell Reforming (OCR) phenomenon is often used to reduce stack temperature by an endothermic reaction of steam-methane reforming process. RIST conducted single-cell experiment to validate modeling tool to simulate OCR performance including temperature measurement. 2D modeling is used to check reforming rate during OCR using temperature measurement data, and 3D modeling is used to check overall thermal performance including furnace boundary conditions.

30 DIRECT ENERGY CONVERSION↗

Experimental evaluation of a stationary spherical reflector tracking absorber solar energy collector

This article presents experimental data for the thermal performance of a stationary, spherical-reflector, tracking-absorber solar energy collector (SRTA). The principle of operation and details of thermal performance of such an SRTA have previously been described. These experimental results were compared with the predictions of a thermal analysis previously published. Experimental results were compared with the prediction of Kreider's computer model. Within the range of the temperature of the experiments, the predicted performance of the unit agreed well with experimental data collected under clear sky conditions. In addition, the extrapolation of the efficiency to higher temperature is shown so that the potential of an SRTA solar collector as a means of providing high temperature steam to operate an electric power facility or for process heat can be evaluated. As a result of the tests conducted by NASA, and an economic analysis not yet publicly available, it appears that the SRTA solar collector concept will be economically viable in competition with any other existing solar system in providing electrical energy.

Steward, W. G.↗

Cogeneration Technology Alternatives Study (CTAS). Volume 3: Energy conversion system characteristics

Six current and thirty-six advanced energy conversion systems were defined and combined with appropriate balance of plant equipment. Twenty-six industrial processes were selected from among the high energy consuming industries to serve as a frame work for the study. Each conversion system was analyzed as a cogenerator with each industrial plant. Fuel consumption, costs, and environmental intrusion were evaluated and compared to corresponding traditional values. The advanced energy conversion technologies indicated reduced fuel consumption, costs, and emissions. Fuel energy savings of 10 to 25 percent were predicted compared to traditional on site furnaces and utility electricity. With the variety of industrial requirements, each advanced technology had attractive applications. Fuel cells indicated the greatest fuel energy savings and emission reductions. Gas turbines and combined cycles indicated high overall annual savings. Steam turbines and gas turbines produced high estimated returns. In some applications, diesels were most efficient. The advanced technologies used coal derived fuels, or coal with advanced fluid bed combustion or on site gasifications. Data and information for both current and advanced energy conversion technology are presented. Schematic and physical descriptions, performance data, equipment cost estimates, and predicted emissions are included. Technical developments which are needed to achieve commercialization in the 1985-2000 period are identified.

Source record↗

Pilot-Scale Evaluation of an Advanced Carbon Sorbent-Based Process for Post-Combustion Carbon Capture

The overall objective of this project is to achieve the DOE’s goal to develop advanced CO 2 capture and separation technologies that can realize at least 90% CO 2 removal from flue gas steams produced at a pulverized coal (PC) power plant at a cost of less than $40/tonne of CO 2 captured. The principal objective is to test a CO 2 capture process that will reduce the parasitic plant load by using a CO 2 capture sorbent that will require a reduced amount of steam. The process is based on advanced carbon sorbents having a low heat of adsorption, high CO 2 adsorption capacity, and excellent selectivity. While the intent of this project was to produce design and performance data by testing the sorbent using a slipstream of coal-derived flue gas at the National Carbon Capture Center (NCCC) under realistic conditions and continuous long-term operation, the project was terminated following completion of the detailing pilot plant design/engineering work on June 30, 2016.

54 ENVIRONMENTAL SCIENCES↗

Green Power Initiative

National energy policy supports the gathering of more detailed and authoritative data on the introduction of renewable bio-based fuels into new and existing district energy systems via the application of biomass gasification. The University of Iowa developed a biomass-fueled, university-scale steam generation system based on biomass gasification technologies. The system serves as a state-of-the-art research and educational facility in the emerging application of gasification in steam generation. The facility, which includes a smaller down-draft gasifier and a larger multi-stage biomass boiler, was designed to operate primarily on wood-based fuels, but has provisions for testing other biomass fuel sources produced within a 100-mile radius, providing enough flexibility to meet the fluctuating local supply of biomass from industry and Midwest agriculture. The equipment was installed in an existing, staffed facility. The down-draft gasifier unit is operated by College of Engineering staff and students, under the direct technical supervision of qualified Utilities plant staff. The Green Power Initiative also includes a substantial, innovative educational component. In addition to an onsite, graduate-level research program in biomass fuels, the investigators have integrated undergraduate and graduate level teaching – through classroom studies and experiential learning – and applied research into a biomass-based, university-scale, functioning power plant. University of Iowa is unique in that it currently has multiple renewable energy technologies deployed, including significant biomass combustion (oat hulls) at its Main Power Plant and a new reciprocating engine based renewable district energy system. This project complements and supports the national energy policy and State of Iowa initiatives in ethanol and biodiesel. Byproducts of ethanol and biodiesel processes (distiller grains) as well as industry residues (oat hulls, wood chips, construction and demolition waste), farm related material (seed corn and soybean seed), and poplar trees for cleaning up ground water are logical feed stocks for gasification.

09 BIOMASS FUELS↗