Search NASA⌕ Search

SEARCH · Search NASA

Results for “structural reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Far-infrared emission, gas, and ultraluminous HII regions in M101

We have made deconvolved maps of M101 in each of the 4 IRAS bands using a new maximum-entropy based model for reconstructing distributions with correlated structure on multiple scales. This new deconvolution procedure, developed by Weir (1992, J.Opt.Soc.Am., submitted), is superior to other maximum entropy-based techniques for several reasons. For our purposes, an important advantage is that it has less artifacts and greatly reduced systematic biases compared with the 'HiRes' maps of M101 produced by Aumann, Fowler, and Melnyk (1990, AJ, 99, 1674), thus it is accurate enough to perform aperture photometry. The deconvolved maps have a maximum resolution of approximately 30 sec, sufficient to resolve the brightest HII complexes and much of the spiral structure. The new maps and our comparison of the far-infrared, gas, and optical distributions are being written up in Kenney, Weir & Scoville (1992, in preparation). The quality of the reconstructed far-infrared maps is good enough for us to carry out most of the analyses outlined in the original proposal. From a ratio of the 60 micron and 100 micron maps, we have found that the ultraluminous HII complexes in the outer galaxy have the hottest dust temperatures with T approximately 50-60 K, which is twice as hot as most of the disk. Their extraordinary luminosity in the far-infrared is due to a relatively small amount of dust being heated to high temperatures, rather than a large concentration of dust and gas. A map of the dust opacity at 60 microns shows good overall agreement with a map of cold gas (HI+H2), indicating that throughout most of the galaxy only approximately 20 percent of the dust is warm enough to be detected by IRAS. The ultraluminous HII complexes have a high luminosity-to-gas mass ratio, independent of whether the far-infrared or the H-alpha emission line is used to measure the luminosity, which implies that gas is being converted into high mass stars more rapidly in these complexes compared to other locations in the disk.

Kenney, J. D. P.↗

Actinic imaging and evaluation of phase structures on EUV lithography masks

The authors describe the implementation of a phase-retrieval algorithm to reconstruct phase and complex amplitude of structures on EUV lithography masks. Many native defects commonly found on EUV reticles are difficult to detect and review accurately because they have a strong phase component. Understanding the complex amplitude of mask features is essential for predictive modeling of defect printability and defect repair. Besides printing in a stepper, the most accurate way to characterize such defects is with actinic inspection, performed at the design, EUV wavelength. Phase defect and phase structures show a distinct through-focus behavior that enables qualitative evaluation of the object phase from two or more high-resolution intensity measurements. For the first time, phase of structures and defects on EUV masks were quantitatively reconstructed based on aerial image measurements, using a modified version of a phase-retrieval algorithm developed to test optical phase shifting reticles.

36 MATERIALS SCIENCE↗

Advancing the Frontiers of Deep Learning for Low-Dose 3D Cone-Beam CT Reconstruction

X-ray computed tomography (CT) is an important noninvasive medical imaging modality for studying the structural details of internal organs. Image reconstruction in CT is an inverse problem of recovering an object's internal structure from the absorption profile of X-ray beams (sinogram) measured using a detector. The classical variational approach for CT reconstruction minimizes an energy functional using an appropriate iterative algorithm. Motivated by the success of deep learning (DL), researchers have begun to leverage training data and enhanced computing capabilities in recent years to produce high-fidelity reconstructed images. Nonetheless, much of the academic research in DL algorithms for CT has focused primarily on the two-dimensional setting (with simplified forward operators and noise model) for proofs-of-concept, and a comprehensive benchmarking of various classical and data-driven CT reconstruction approaches has not beenundertaken. The key objective of our CT reconstruction grand challenge was to promote methodological advancements for both classical and DL-based approaches for clinical CT with a reasonably accurately simulated 3D CT forward operator and noise model. We have utilized the publicly available LIDC-IDRI dataset and simulated sinograms and FDK images corresponding to two dose levels (clinical- and low-dose, constituting two tracks of the challenge) starting from the normal-dose images as the ground truth. In this paper, we summarize the motivation, context, and results of our challenge, and highlight the future research directions in DL for clinical CT.

X-ray tomography↗

Fluid Physics of Foam Evolution and Flow

The grant supported theoretical, numerical and experimental work focused on the elucidation of the fluid physics of foam structure, evolution and flow. The experimental work concentrated on these subject areas: (a) Measurements of the speed of reconnections within a foam; (b) statistics of bubble rearrangements; and (c) three-dimensional reconstruction of the foam structure. On the numerical simulation and theory side our efforts concentrated on the subjects: (a) simulation techniques for 2D and 3D foams; (b) phase transition in a compressible foam; and (c) TCP structures.

Aref, H.↗

Study of the internal structure of lithium fluoride single crystal by laboratory X-ray topo-tomography

Defects in a synthetic LiF crystal have been studied by X-ray topo-tomography on laboratory X-ray sources with a spatial resolution of {approx}10 {mu}m. An algebraic reconstruction method was applied to reconstruct the defect 3D structure of the crystal based on the diffraction data. The results presented in this study are in good agreement with the topographic data obtained by the Lang method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A quantitative comparison of the fingerprint of twinned microstructures through surface and three-dimensional techniques

Assessing the fingerprint of a material’s microstructure is key for supporting materials design. With the emergence of a wide range of 3D characterization techniques, it is critical to understand the main differences in fingerprints reconstructed from 2D and 3D datasets. To this end, we introduce a graph-based microstructure reconstruction framework that enables structural comparisons of twin domain networks in high purity Ti using 3D and 2D electron backscatter diffraction. Insights into the structure of the twin networks are facilitated by combining statistical analysis of twin crystallography with visual and graphical analysis of the novel graph abstractions of the twins. We demonstrate that compared to 3D reconstructions, conventional 2D views of twinning miss key aspects of the microstructure including the high interconnectivity of domains into networks that span the full reconstruction volume. The reduced cross-grain and in-grain twin connectivity typically observed in 2D has notable implications on our understanding of how twinning mediates the plastic response of microstructures and how twin networks evolve. It is thus clear that 3D characterization is critical for accurately inferring both twin network morphologies as well as the key unit processes facilitating network formation.

36 MATERIALS SCIENCE↗

Ultrasparse View X-ray Computed Tomography for 4D Imaging

X-ray computed tomography (CT) is a noninvasive, nondestructive approach to imaging materials, material systems, and engineered components in two and three dimensions. Acquisition of three-dimensional (3D) images requires the collection of hundreds or thousands of through-thickness X-ray radiographic images from different angles. Such 3D data acquisition strategies commonly involve suboptimal temporal sampling for in situ and operando studies (4D imaging). Herein, we introduce a sparse-view imaging approach, Tomo-NeRF, which is capable of reconstructing high-fidelity 3D images from <10 twodimensional radiographic images. Experimental 2D and 3D X-ray images were used to test the reconstruction capability in two-view, four-view, and six-view scenarios. Tomo-NeRF is capable of reconstructing 3D images with a structural similarity of 0.9971–0.9975 and a voxel-wise accuracy of 81.83–89.59% from 2D experimentally obtained images. Furthermore, the reconstruction accuracy for the experimentally obtained images is less than the synthetic structures. Experimentally obtained images demonstrate a similarity of 0.9973–0.9984 and a voxelwise accuracy of 84.31–95.77%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A clinically feasible method for the detection of potential collision in proton therapy

Purpose: Potential collision between the patient/couch and the gantry could delay the start of the treatment and reduce clinical efficiency. The ability to accurately detect possible collisions during the treatment planning phase is desired. Such collision detection should account for the specific proton gantry design, the treatment beam configuration, couch orientation, and the patient specific geometry. In this paper the authors developed an approach to detect possible patient-machine collisions using patient treatment plan data. Methods: The geometry of the machine and the patient was reconstructed relative to the isocenter of the proton treatment room. The surface contour of the gantry was first captured from the proton computer aided design and reconstructed to account for specific gantry rotation, snout position, collimator rotation, and range compensator dimensions based on the patient treatment plan data. The patient body and couch contours were captured from the patient's CT DICOM structure file. They were reconstructed relative to the isocenter taking into account treatment couch rotation. For potential collision that occurs at body portions where no CT images exist, scout images are used to construct the body contour. A software program was developed using a ray casting algorithm that was applied to detect collisions by determining if any of the patient and couch contour points fall into the spatial polygons formed by the proton gantry surfaces. Results: Twenty-four patient plans with or without potential collisions were retrospectively identified and analyzed using the collision detection software. In addition, five collision cases were artificially generated using an anthropomorphic phantom. The program successfully detected the collisions in all cases. The calculation time for each case was within 20 s. The software program was implemented in the authors' clinic to detect patient-gantry or gantry-couch collisions in the treatment planning phase. Conclusions: The authors developed a fast and clinically feasible patient-specific collision detection program for proton therapy based on a ray casting algorithm. If incorporated during the treatment planning phase it may lead to improved clinical efficiency. This methodology could also be applied to patient collision detection in photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-18A-04: 3D Dictionary Learning Based Statistical Iterative Reconstruction for Low-Dose Cone Beam CT Imaging

Purpose: To develop a 3D dictionary learning based statistical reconstruction algorithm on graphic processing units (GPU), to improve the quality of low-dose cone beam CT (CBCT) imaging with high efficiency. Methods: A 3D dictionary containing 256 small volumes (atoms) of 3x3x3 voxels was trained from a high quality volume image. During reconstruction, we utilized a Cholesky decomposition based orthogonal matching pursuit algorithm to find a sparse representation on this dictionary basis of each patch in the reconstructed image, in order to regularize the image quality. To accelerate the time-consuming sparse coding in the 3D case, we implemented our algorithm in a parallel fashion by taking advantage of the tremendous computational power of GPU. Evaluations are performed based on a head-neck patient case. FDK reconstruction with full dataset of 364 projections is used as the reference. We compared the proposed 3D dictionary learning based method with a tight frame (TF) based one using a subset data of 121 projections. The image qualities under different resolutions in z-direction, with or without statistical weighting are also studied. Results: Compared to the TF-based CBCT reconstruction, our experiments indicated that 3D dictionary learning based CBCT reconstruction is able to recover finer structures, to remove more streaking artifacts, and is less susceptible to blocky artifacts. It is also observed that statistical reconstruction approach is sensitive to inconsistency between the forward and backward projection operations in parallel computing. Using high a spatial resolution along z direction helps improving the algorithm robustness. Conclusion: 3D dictionary learning based CBCT reconstruction algorithm is able to sense the structural information while suppressing noise, and hence to achieve high quality reconstruction. The GPU realization of the whole algorithm offers a significant efficiency enhancement, making this algorithm more feasible for potential clinical application. A high zresolution is preferred to stabilize statistical iterative reconstruction. This work was supported in part by NIH(1R01CA154747-01), NSFC((No. 61172163), Research Fund for the Doctoral Program of Higher Education of China (No. 20110201110011), China Scholarship Council.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transport anomalies in the layered compound BaPt 4 Se 6

We report a layered ternary selenide BaPt 4 Se 6 featuring sesqui-selenide Pt 2 Se 3 layers sandwiched by Ba atoms. The Pt 2 Se 3 layers in this compound can be derived from the Dirac-semimetal PtSe 2 phase with Se vacancies that form a honeycomb structure. This structure results in a Pt (VI) and Pt (II) mixed-valence compound with both PtSe 6 octahedra and PtSe 4 square net coordination configurations. Temperature-dependent electrical transport measurements suggest two distinct anomalies: a resistivity crossover, mimic to the metal-insulator (M-I) transition at ~150 K, and a resistivity plateau at temperatures below 10 K. The resistivity crossover is not associated with any structural, magnetic, or charge order modulated phase transitions. Magnetoresistivity, Hall, and heat capacity measurements concurrently suggest an existing hidden state below 5 K in this system. Angle-resolved photoemission spectroscopy measurements reveal a metallic state and no dramatic reconstruction of the electronic structure up to 200 K.

36 MATERIALS SCIENCE↗

Efficient high-resolution rotor wake calculations using flow field reconstruction

Recent computational studies of helicopter flowfields for acoustic applications has led to the development of exceptionally efficient analysis methods for carrying out Lagrangian simulations of the vortex wake. The capabilities of these methods are demonstrated here through calculations involving a variety of wake/rotor interactions associated with both main rotor and tail rotor flowfields. These methods incorporate a flowfield reconstruction approach efficiently to compute vortex wake interactions within arbitrary regions located near the main rotor. This paper summarizes the development of the reconstruction approach and outlines some of its potential uses, while focusing primarily on its application to rotor noise calculations. The development of the nearfield velocity corrections used in the analysis of close vortex interactions is described, and the overall structure of the current reconstruction approach is discussed.

Quackenbush, Todd R.↗

Fast ion transport in the quasi-single helical reversed-field pinch

The reversed-field pinch (RFP) can spontaneously transition from an axisymmetric magnetic topology to a 3D-helical geometry. Investigations on fast ion transport associated with energetic particle driven Alfvén instabilities, tearing mode induced stochasticity, and neoclassical effects have been performed on the Madison Symmetric Torus. STELLGAP produced shear-Alfvén continua seeded with V3FIT 3D-equilibrium reconstructions describe the response of Alfvénic bursting activity as a direct consequence of the equilibrium change on the fast ion resonance. Furthermore, far infrared interferometry resolved electron density perturbations associated with the bursts provide a spatial measurement of the mode structure and support the reconstructions. The bursts produce no global resonant fast ion transport; however, their disappearance at a high core-resonant amplitude implies other transport mechanisms at play. Additionally, neutral particle analysis and neutron signals suggest fast ion losses at sufficient core tearing mode strength, supporting the lack of Alfvénic activity. The guiding-center code ORBIT corroborates rapid fast ion loss times in the helical state largely as a consequence of remnant tearing modes. Additionally, ORBIT simulations demonstrate little neoclassical enhancement of particle transport. While superbanana orbits may exist, the growth in the core-resonant fast ion island and the associated secondary mode overlap govern the largest transport process, leading to robust fast ion losses in the 3D-RFP.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification of a low-energy metastable 1 T -type phase for monolayer VSe 2

Elucidating the polymorphism of transition metal dichalcogenide layers and the interplay between structure and properties is a key challenge for the application of these materials. We identify a low-energy metastable phase of monolayer VSe 2 and elucidate its magnetic and electronic properties. This structure is distinct from the previously identified charge density wave (CDW) phase. However, while having rather distinct properties it is very close in energy to the CDW phase and is likely to be realized in experiments. Importantly, local bonding instabilities, as characterized by reconstruction of the electronic structure over a wide energy range, are important for this distortion, which includes both V off-centering in the octahedral coordination cages and a partial disproportionation into two distinct types of V. The phase does not have a ferromagnetic ground state. Furthermore, the results show that the physics of 1T–VSe 2 are richer than previously known with an interplay of Fermi surface instabilities and local bonding effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermoelectric properties of symmetric and asymmetric double quantum well structures

The electronic states and carrier transport in (100)PbTe/Pb {sub 1-x} Eu{sub x} Te double quantum wells are theoretically analyzed. The dependences of the mobility and Seebeck coefficient on the thickness of the internal barrier in symmetric and asymmetric structures are investigated. It was found that at great distance between the wells even small violation of the structure symmetry and essential reconstruction of electron wave functions results in suppression of intersubband scattering with carriers transfer between the wells and provides the correct limit to isolated quantum well in kinetic coefficients. Some possibilities of increasing the thermoelectric power factor are found, and a suitable set of structure parameters is calculated within the proposed model.

36 MATERIALS SCIENCE↗

Model reduction for flexible structures - Test data approach

A reduced model of a system is obtained by truncating part of its state variables. Hankel singular values and component costs determine which component is deleted or retained in the reduced model. In this paper Hankel singular values and component costs of a flexible structure are obtained from the resonance test data, rather than from the system matrices. Test data, besides system dynamics, include also actuators and sensors dynamics. For this reason, the reduced model obtained from test data can be far from the optimal one. In this paper the reconstruction of the flexible structure indices from the joint actuator-sensor-flexible structure indices is discussed.

Gawronski, Wodek↗

Revealing latent pole and zone line information in atom probe detector maps using crystallographically correlated metrics

Poles and zone lines observed within atom probe field evaporation images are useful for a range of atom probe crystallography studies, including calibration of the reconstruction and crystallographic characterisation of microstructural features such as grain boundaries. However, this information is not always readily apparent. Techniques for plotting crystallographically correlated metrics contained within atom probe data to enhance pole and zone line contrast across the detector space are developed. This includes consideration of the electric field, molecular ions, lattice structure retained within the reconstruction, specific elemental species, the number of pulses between detection events, and the lateral distance between sequential detection events. These approaches are then applied to experimental atom probe tomography datasets on technically pure Al, nanocrystalline Al, highly doped Si, and additively manufactured Inconel 738, Haynes 282, and Ti–6Al–4V. The results facilitate the extension of atom probe crystallography studies to a broader range of crystalline datasets where crystallographic information is not readily apparent from existing methods, as well as a deeper understanding of field evaporation behaviour during an atom probe experiment.

47 OTHER INSTRUMENTATION↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of a biological object with optical coherent tomography structural images using a voxel-based geometry of a medium

We describe a Monte Carlo algorithm for simulating an interference signal and constructing a structural image of a biological object using optical coherent tomography (OCT). The algorithm is specific in that the object geometry is described by using a three-dimensional array of voxels combined into parallelograms, and the border cross checking is carried out by using an improved Smith algorithm. The geometry of the simulated object is reconstructed based on the structure of real biological tissues obtained by OCT. The algorithm efficiency is estimated by comparing experimental and corresponding simulated images of a subcutaneous blood vessel and upper layer of human skin in vivo . (biophotonics)

60 APPLIED LIFE SCIENCES↗