Structural geologic analysis of Nevada using ERTS-1 images: A preliminary report

Structural analysis of Nevada using ERTS-1 images showns several previously unrecognized lineaments which may be the surface manifestations of major fault or fracture zones. Principle trends are NE, NW, NNE-NNW, and ENE. Two lineament zones, the Walker Lane and Midas Trench lineament system, transect the predominantly NNE-NNW trending mountain ranges for more than 500 km. 50 circular features have been delineated. Comparison with known Tertiary volcanic centers and reference to geologic maps suggest 8 new centers. Preferred distribution of mines and Tertiary volcanic centers along some of the major lineament suggests a genetic relationship. The intersection of three previously unmapped lineaments in northwestern Nevada is the location of a highly productive metallogenic district. In the Walker Lane, ENE-trending lineament appear to be related to the occurrence of productive ore deposits.

Rowan, L. C.↗

Evaluation of LANDSAT-2 (ERTS) images applied to geologic structures and mineral resources of South America

The author has identified the following significant results. Work with the Image 100 clearly demonstrates that radiance values of LANDSAT data can be used for correlation of geologic formations across international boundaries. The Totora Formation of the Corocoro Group of Tertiary age was traced from known outcrops near Tiahuanaco, Bolivia, along the south side of Lake Titicaca westward into Peru where the same rocks are considered to be Cretaceous in age. This inconsistency suggests: (1) that a review of this formation is needed by joint geological surveys of both countries to determine similarities, differences, and the true age; (2) that recognition of the extension of the copper-bearing Totora Formation of Bolivia into Peru may provide Peru with a new target for exploration. Equal radiance maps made by use of the Image 100 system show as many as eight different units within salar deposits (salt flats) of the Bolivian Altiplano. Standard film processed images show them as nearly uniform areas of white because of lack of dynamic range in film products. The Image 100 system, therefore, appears to be of great assistance in subdividing the salt flats on the basis of moisture distribution, surface roughness, and distribution of windblown materials. Field work is needed to determine these relationships to mineral composition and distribution. Images representing seasonal changes should also improve the accuracy of such maps. Radiance values of alteration zones related to the occurrence of porphyry copper ores were measured at the San Juan del Abra deposit of northern Chile using the Image 100 system. The extent to which these same values may be used to detect similar alteration zones in other areas has not yet been tested.

Carter, W. D.↗

Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma

Purpose: Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as intermediate endpoints of asthma severity and control. In particular, pulmonary {sup 1}H MRI can be used to provide quantitative lung structure-function measurements longitudinally and in response to treatment. However, to translate such biomarkers of asthma, robust methods are required to segment the lung from pulmonary {sup 1}H MRI. Therefore, their objective was to develop a pulmonary {sup 1}H MRI segmentation algorithm to provide regional measurements with the precision and speed required to support clinical studies. Methods: The authors developed a method to segment the left and right lung from {sup 1}H MRI acquired in 20 asthmatics including five well-controlled and 15 severe poorly controlled participants who provided written informed consent to a study protocol approved by Health Canada. Same-day spirometry and plethysmography measurements of lung function and volume were acquired as well as {sup 1}H MRI using a whole-body radiofrequency coil and fast spoiled gradient-recalled echo sequence at a fixed lung volume (functional residual capacity + 1 l). We incorporated the left-to-right lung volume proportion prior based on the Potts model and derived a volume-proportion preserved Potts model, which was approximated through convex relaxation and further represented by a dual volume-proportion preserved max-flow model. The max-flow model led to a linear problem with convex and linear equality constraints that implicitly encoded the proportion prior. To implement the algorithm, {sup 1}H MRI was resampled into ∼3 × 3 × 3 mm{sup 3} isotropic voxel space. Two observers placed seeds on each lung and on the background of 20 pulmonary {sup 1}H MR images in a randomized dataset, on five occasions, five consecutive days in a row. Segmentation accuracy was evaluated using the Dice-similarity-coefficient (DSC) of the segmented thoracic cavity with comparison to five-rounds of manual segmentation by an expert observer. The authors also evaluated the root-mean-squared-error (RMSE) of the Euclidean distance between lung surfaces, the absolute, and percent volume error. Reproducibility was measured using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) for two observers who repeated segmentation measurements five-times. Results: For five well-controlled asthmatics, forced expiratory volume in 1 s (FEV{sub 1})/forced vital capacity (FVC) was 83% ± 7% and FEV{sub 1} was 86 ± 9%{sub pred}. For 15 severe, poorly controlled asthmatics, FEV{sub 1}/FV C = 66% ± 17% and FEV{sub 1} = 72 ± 27%{sub pred}. The DSC for algorithm and manual segmentation was 91% ± 3%, 92% ± 2% and 91% ± 2% for the left, right, and whole lung, respectively. RMSE was 4.0 ± 1.0 mm for each of the left, right, and whole lung. The absolute (percent) volume errors were 0.1 l (∼6%) for each of right and left lung and ∼0.2 l (∼6%) for whole lung. Intra- and inter-CoV (ICC) were <0.5% (>0.91%) for DSC and <4.5% (>0.93%) for RMSE. While segmentation required 10 s including ∼6 s for user interaction, the smallest detectable difference was 0.24 l for algorithm measurements which was similar to manual measurements. Conclusions: This lung segmentation approach provided the necessary and sufficient precision and accuracy required for research and clinical studies.

60 APPLIED LIFE SCIENCES↗

Seeing is believing: novel imaging techniques help clarify microbial nanowire structure and function

Summary Novel imaging approaches have recently helped to clarify the properties of ‘microbial nanowires’. G eobacter sulfurreducens pili are actual wires. They possess metallic‐like conductivity, which can be attributed to overlapping pi‐pi orbitals of key aromatic amino acids. Electrostatic force microscopy recently confirmed charge propagation along the pili, in a manner similar to carbon nanotubes. The pili are essential for long‐range electron transport to insoluble electron acceptors and interspecies electron transfer. Previous claims that S hewanella oneidensis also produce conductive pili have recently been recanted, based on novel live‐imaging studies. The putative pili are, in fact, long extensions of the cytochrome‐rich outer membrane and periplasm that, when dried, collapse to form filaments with dimensions similar to pili. It has yet to be demonstrated whether the cytochrome‐to‐cytochrome electron hopping documented in the dried membrane extensions takes place in intact hydrated membrane extensions or whether the membrane extensions enhance electron transport to insoluble electron acceptors such as F e( III ) oxides or electrodes. These findings demonstrate that G . sulfurreducens conductive pili and the outer membrane extensions of S . oneidensis are fundamentally different in composition, mechanism of electron transport and physiological role. New methods for evaluating filament conductivity will facilitate screening the microbial world for nanowires and elucidating their function.

Lovley, Derek R.↗

Imaging of Hydrogel Microsphere Structure and Foreign Body Response Based on Endogenous X-Ray Phase Contrast

Transplantation of functional islets encapsulated in stable biomaterials has the potential to cure Type I diabetes. However, the success of these materials requires the ability to understand their stability in vivo. Imaging techniques that enable monitoring of biomaterial performance are critical to further development in the field. In this study, we demonstrate for the first time that X-ray phase contrast (XPC) imaging techniques enable 3D imaging and evaluation of islet volume, alginate hydrogel structure and local soft tissue response. Islets were encapsulated in alginate systems prepared in methods used in clinical trials and implanted in a rodent omentum pouch model as a treatment for type I diabetes. Microbeads were imaged with XPC prior to implantation and following implantation into an omentum pouch. Islets could be identified within alginate beads and the islet volume quantified. Omental adipose tissue could be distinguished from inflammatory regions resulting from implanted beads. Individual beads and the local encapsulation response were visualized and quantifiable. Measurements were in agreement with histology. The 3D structure of the microbeads could be characterized with XPC and failed beads could also be identified. These results point to the substantial potential of XPC as a tool for imaging biomaterials in small animal models.

59 BASIC BIOLOGICAL SCIENCES↗

Structured illumination with thermal imaging (SI-TI): A dynamically reconfigurable metrology for parallelized thermal transport characterization

The recent push for the “materials by design” paradigm requires synergistic integration of scalable computation, synthesis, and characterization. Among these, techniques for efficient measurement of thermal transport can be a bottleneck limiting the experimental database size, especially for diverse materials with a range of roughness, porosity, and anisotropy. Traditional contact thermal measurements have challenges with throughput and the lack of spatially resolvable property mapping, while non-contact pump-probe laser methods generally need mirror smooth sample surfaces and also require serial raster scanning to achieve property mapping. Here, we present structured illumination with thermal imaging (SI-TI), a new thermal characterization tool based on parallelized all-optical heating and thermometry. Experiments on representative dense and porous bulk materials as well as a 3D printed thermoelectric thick film (~50 μm) demonstrate that SI-TI (1) enables paralleled measurement of multiple regions and samples without raster scanning; (2) can dynamically adjust the heating pattern purely in software, to optimize the measurement sensitivity in different directions for anisotropic materials; and (3) can tolerate rough (~3 μm) and scratched sample surfaces. Here, this work highlights a new avenue in adaptivity and throughput for thermal characterization of diverse materials.

42 ENGINEERING↗

Discrimination of Bond Order in Organic Molecules Using Noncontact Atomic Force Microscopy

Noncontact atomic force microscopy (nc-AFM) with a CO-functionalized tip can image submolecular structures through high-resolution images with the possibility of discriminating bond order. Here, we employ real-space pseudopotential calculations to simulate nc-AFM images of molecules containing double (dibenzo(cd,n)naphtho(3,2,1,8-pqra)perylene (DBNP), hexabenzo(bc,ef,hi,kl,no,qr)coronene (HBC)) and triple (1,2-bis[2-(2-ethynylphenyl)ethynyl]-benzene (BEEB), 6-phenylhexa-1,3,5-triynylbenzene (PHTB)) bonds. We find (1) triple bonds can be unambiguously distinguished from other interatomic interactions based on a characteristic image and (2) the degree of double bond character can be directly determined from the image. We propose that large lateral forces acting on the tip may induce specific image distortions in the cases of DBNP and BEEB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal tomography 3D imaging of additively manufactured metallic structures

Thermal tomography is a computational method for heat diffusion-based imaging of solids, which provides 3D visualization of data from flash thermography measurements. We investigate thermal tomography imaging and nondestructive evaluation of stainless steel and nickel super alloy metallic structures produced with the laser powder bed fusion (LPBF) additive manufacturing (AM) process. Metallic structures produced with LPBF contain defects, and there are limited capabilities to evaluate these structures non-destructively. Thermal tomography reconstruction of 3D apparent spatial effusivity provides information about AM structure geometry and internal material flaws. We study performance of thermal tomography in imaging of metallic structures through COMSOL computer simulations of transient heat transfer and through reconstruction of data obtained from experimental measurements. Thermal tomography reconstructions of structure shape and dimensions are shown for the Inconel 718 AM structure which has variations in the horizontal plane but is uniform along the depth dimension. Reconstruction of internal defects is investigated using a stainless steel 316L specimen with flat bottom hole (FBH) indentations, and the Inconel 718 plate is produced with the LPBF method, which contains imprinted hemispherical shape low density regions containing non-sintered metallic powder. The FBHs have the same sizes as the imprinted defects in the LPBF specimens but offer better imaging contrast. Thermal tomography reconstructions provide visualizations of internal defects and allow for estimation of their sizes and locations. Results of this study demonstrate that thermal tomography can be used for visualization and quality control in AM.

36 MATERIALS SCIENCE↗

Collaborative Research: Tomographic Imaging of Evolving Laser-Plasma Structures

The project, Collaborative Research: Tomographic Imaging of Evolving Laser-Plasma Structures, involved collaborating with researchers at the University of Texas to understand the acceleration of particles by the interaction of the Texas Petawatt Laser with plasma. Multiple envelope simulations were performed as a study of the effects of collision angle and polarization of interacting hot spots on total charge. A new algorithm for integrating particles in simulations was developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sound for Sensing, Imaging and Creating Unique Structures [Slides]

Sound waves can be used to: extract physical properties of a medium through which it propagates (i.e., can be used to sense); exert force on objects to create useful structures; and create unusual sound source that produces highly collimated beam at low frequencies for imaging objects in opaque media.

42 ENGINEERING↗

Tangential soft-x ray imaging for three-dimensional structural studies in a reversed field pinch

Tangential soft-x ray (SXR) imaging diagnostic has been developed and three-dimensional (3D) structure of the internal magnetic surface has been deduced by comparing the experimental and calculated two-dimensional SXR images in a reversed field pinch. The SXR imaging system, consisting of a MCP, a fluorescent plate, and an intensified charge coupled device camera, has been installed in REversed field pinch of Low-Aspect-ratio eXperiment (RELAX) machine. Major characteristics of an experimental SXR image could be reproduced by numerical calculations of the image using a single island model, suggesting a helical hot core in RELAX. The SXR imaging system could be useful for 3D structural studies when tangential and vertical simultaneous imaging systems would be installed, with appropriate numerical modeling of 3D structure of the magnetic surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertical Structure of Local Disk Galaxies Revealed by DESI Imaging Data

The vertical structure of galactic disks is an important probe of the disk assembly history. Here we investigate the vertical structure of a sample of 79 local disk galaxies within 50 Mpc using data from the Dark Energy Spectroscopic Instrument Legacy Imaging Surveys. Vertical luminosity profiles as a function of radius in the g, r, and z bands are extracted and fitted using a single-component sech2 model to determine scale height and its radial variation (i.e., flaring). Our measurements indicate local galactic disks are overall thin with negligible flaring. The median scale heights at 1 R e are 0.21, 0.22, and 0.22 kpc in the g, r, and z bands, respectively, while the median radial gradients of scale height are −0.006, 0.003, and 0.001 in these bands. These values are consistent with that of the geometric thin disk of the Milky Way represented by metal-rich, low-[α/Fe] populations, confirming the weak flaring of the geometric thin disk. A clear positive correlation of scale height with stellar mass is observed down to the low-mass end of 10 7 M ⊙ . These results provide a homogeneous benchmark for the vertical structure of nearby disk galaxies and establish the cosmological representativeness of the Milky Way thin disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced Imaging of Corrosion in Aircraft Structures with Reverse Geometry X-ray(registered tm)

The application of Reverse Geometry X-ray to the detection and characterization of corrosion in aircraft structures is presented. Reverse Geometry X-ray is a unique system that utilizes an electronically scanned x-ray source and a discrete detector for real time radiographic imaging of a structure. The scanned source system has several advantages when compared to conventional radiography. First, the discrete x-ray detector can be miniaturized and easily positioned inside a complex structure (such as an aircraft wing) enabling images of each surface of the structure to be obtained separately. Second, using a measurement configuration with multiple detectors enables the simultaneous acquisition of data from several different perspectives without moving the structure or the measurement system. This provides a means for locating the position of flaws and enhances separation of features at the surface from features inside the structure. Data is presented on aircraft specimens with corrosion in the lap joint. Advanced laminographic imaging techniques utilizing data from multiple detectors are demonstrated to be capable of separating surface features from corrosion in the lap joint and locating the corrosion in multilayer structures. Results of this technique are compared to computed tomography cross sections obtained from a microfocus x-ray tomography system. A method is presented for calibration of the detectors of the Reverse Geometry X-ray system to enable quantification of the corrosion to within 2%.

Winfree, William P.↗

Single-Transducer, Ultrasonic Imaging Method for High-Temperature Structural Materials Eliminates the Effect of Thickness Variation in the Image

NASA Lewis Research Center's Life Prediction Branch, in partnership with Sonix, Inc., and Cleveland State University, recently advanced the development of, refined, and commercialized an advanced nondestructive evaluation (NDE) inspection method entitled the Single Transducer Thickness-Independent Ultrasonic Imaging Method. Selected by R&D Magazine as one of the 100 most technologically significant new products of 1996, the method uses a single transducer to eliminate the superimposing effects of thickness variation in the ultrasonic images of materials. As a result, any variation seen in the image is due solely to microstructural variation. This nondestructive method precisely and accurately characterizes material gradients (pore fraction, density, or chemical) that affect the uniformity of a material's physical performance (mechanical, thermal, or electrical). Advantages of the method over conventional ultrasonic imaging include (1) elimination of machining costs (for precision thickness control) during the quality control stages of material processing and development and (2) elimination of labor costs and subjectivity involved in further image processing and image interpretation. At NASA Lewis, the method has been used primarily for accurate inspections of high temperature structural materials including monolithic ceramics, metal matrix composites, and polymer matrix composites. Data were published this year for platelike samples, and current research is focusing on applying the method to tubular components. The initial publicity regarding the development of the method generated 150 requests for further information from a wide variety of institutions and individuals including the Federal Bureau of Investigation (FBI), Lockheed Martin Corporation, Rockwell International, Hewlett Packard Company, and Procter & Gamble Company. In addition, NASA has been solicited by the 3M Company and Allison Abrasives to use this method to inspect composite materials that are manufactured by these companies.

Roth, Don J.↗

3-D Structure of Sunspots using Imaging Spectroscopy

We use the Interferometric BIdimensional Spectrometer (IBIS) of the INAF/Arcetri Astrophysical Observatory and installed at the National Solar Observatory (NSO) Dunn Solar Telescope, to understand the structure of sunspots. Using the spectral lines FeI 6301.5 A, FeII 7224.4 A, and CaII 8542.6 A, we examine the spectroscopic variation of sunspot penumbral and umbral structures at the heights of formation of these lines. These high resolution observations were acquired on 2004 July 30-31, of active region NOAA 10654, using the high order NSO adaptive optics system. We map the spatio-temporal variation of Doppler signatures in these spectral lines, from the photosphere to the chromosphere. From a 70-minute temporal average of individual 32-second cadence Doppler observations we find that the averaged velocities decrease with height, about 3.5 times larger in the deeper photosphere (FeII 7224.4 A; height-of-formation approx. 50 km) than in the upper photosphere FeI 6301.5 A; height-of-formation approx. 350 km), There is a remarkable coherence of Doppler signals over the height difference of 300 km. From a high-speed animation of the Doppler sequence we find evidence for what appears to be ejection of high speed gas concentrations from edges of penumbral filaments into the surrounding granular photosphere. The Evershed flow persists a few arcseconds beyond the traditionally demarcated penumbra-granulation boundary. We present these and other results and discuss the implications of these measurements for sunspot models.

Balasubramaniam, K. S.↗

Analysis of the characteristics appearing in LANDSAT multispectral images in the geological structural mapping of the midwestern portion of the Rio Grande do Sul shield

The central-western part of Rio Grande do Sul Shield was geologically mapped to test the use of MSS-LANDSAT data in the study of mineralized regions. Visual interpretation of the images a the scale of 1:500,000 consisted, in the identification and analysis of the different tonal and textural patterns in each spectral band. After the structural geologic mapping of the area, using visual interpretation techniques, the statistical data obtained were evaluated, specially data concerning size and direction of fractures. The IMAGE-100 system was used to enlarge and enhance certain imagery. The LANDSAT MSS data offer several advantages over conventional white and black aerial photographs for geological studies. Its multispectral characteristic (band 6 and false color composition of bands 4, 5 and 7 were best suitable for the study). Coverage of a large imaging area of about 35,000 sq km, giving a synoptical view, is very useful for perceiving the regional geological setting.

Parada, N. D. J.↗

Appraisal of a cementitious material for waste disposal: Neutron imaging studies of pore structure and sorptivity

Cementitious materials are conventionally used in conditioning intermediate and low level radioactive waste. In this study a candidate cement-based wasteform has been investigated using neutron imaging to characterise the wasteform for disposal in a repository for radioactive materials. Imaging showed both the pore size distribution and the extent of the cracking that had occurred in the samples. The rate of the water penetration measured both by conventional sorptivity measurements and neutron imaging was greater than in pastes made from Ordinary Portland Cement. The ability of the cracks to distribute the water through the sample in a very short time was also evident. The study highlights the significant potential of neutron imaging in the investigation of cementitious materials. The technique has the advantage of visualising and measuring, non-destructively, material distribution within macroscopic samples and is particularly useful in defining movement of water through the cementitious materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling up the Single Transducer Thickness-Independent Ultrasonic Imaging Method for Accurate Characterization of Microstructural Gradients in Monolithic and Composite Tubular Structures

Ultrasonic velocity/time-of-flight imaging that uses back surface reflections to gauge volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse-echo ultrasonic velocity/time-of-flight imaging is that the image shows the effects of thickness as well as microstructural variations unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse-echo time-of-flight-based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples that eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material microstructure in plate-like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex-shaped structures-those having (hollow) tubular/curved geometry. The experimental inspection technique and results are described as applied to (1) monolithic mullite ceramic and polymer matrix composite 'proof-of-concept' tubular structures that contain machined patches of various depths and (2) as-manufactured monolithic silicon nitride ceramic and silicon carbide/silicon carbide composite tubular structures that might be used in 'real world' applications.