Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLNL FY22 Aging and Lifetimes Exit Criteria (Milestone 8118, GC#5)

This report introduces a novel characterization tool that can rapidly collect in-situ time-dependent oxide thickness and hydride growth data together with spatial data using while-light interferometry. White-light interferometry is a non-destructive and non-contact optical surface profiling technique for materials characterization that offers excellent lateral and vertical resolution. A depleted uranium sample was used to assess the ability of white-light interferometry to provide quantitative corrosion reaction rates at metal surfaces for by hydriding and oxidation and compare this technique to existing characterization tools for capturing early-stage hydride and oxide growth kinetics.

36 MATERIALS SCIENCE↗

Vapor grown silicon dioxide improves transistor base-collector junctions

Vapor grown silicon dioxide layer protects base-collector junction in silicon planar transistors during the emitter diffusion process. This oxide fills in any imperfections that exist in the thermally grown oxide layer and is of greater thickness than that layer. This process is used to deposit protective silicon dioxide coatings on optical surfaces.

Carley, D. R.↗

Machining heavy plastic sections

Machining technique produces consistently satisfactory plane-parallel optical surfaces for pressure windows, made of plexiglass, required to support a photographic study of liquid rocket combustion processes. The surfaces are machined and polished to the required tolerances and show no degradation from stress relaxation over periods as long as 6 months.

Stalkup, O. M.↗

Computer program for optical systems ray tracing

Program traces rays of light through optical systems consisting of up to 65 different optical surfaces and computes the aberrations. For design purposes, paraxial tracings with astigmation and third order tracings are provided.

Ferguson, T. J.↗

A computer program to evaluate optical systems

A computer program is used to evaluate a 25.4 cm X-ray telescope at a field angle of 20 minutes of arc by geometrical analysis. The object is regarded as a point source of electromagnetic radiation, and the optical surfaces are treated as boundary conditions in the solution of the electromagnetic wave propagation equation. The electric field distribution is then determined in the region of the image and the intensity distribution inferred. A comparison of wave analysis results and photographs taken through the telescope shows excellent agreement.

Innes, D.↗

Observing Venus near the sun.

Discussion of the special requirements posed by telescopic observing near the sun. The sky brightness in the image plane must be kept to a minimum. Sunlight scattered from dust in the atmosphere or on the optical surfaces is the main difficulty, particularly at red and infrared wavelengths where Rayleigh scattering by air molecules is weak. Atmospheric dust is less troublesome at high altitudes and in dry climates than at low, humid sites. Excellent seeing is required, especially to get the thin crescent of Venus at inferior conjunction into the narrow slit of a spectrograph. The spectroscopic phase effect of Venus is discussed, and the procedures used to carry out observations near the sun are described in detail.

Young, A. T.↗

Active cleaning technique device

The objective of this program was to develop a laboratory demonstration model of an active cleaning technique (ACT) device. The principle of this device is based primarily on the technique for removing contaminants from optical surfaces. This active cleaning technique involves exposing contaminated surfaces to a plasma containing atomic oxygen or combinations of other reactive gases. The ACT device laboratory demonstration model incorporates, in addition to plasma cleaning, the means to operate the device as an ion source for sputtering experiments. The overall ACT device includes a plasma generation tube, an ion accelerator, a gas supply system, a RF power supply and a high voltage dc power supply.

Shannon, R. L.↗

Control of contaminants on sensors. Report 1: Interdirectorate working group on earth observation sensors

Examples of contamination of sensors from various sources during space missions are presented. Design precautions to provide access to optical surfaces and venting of outgassing products are recommended as methods for coping with contamination. The effects of the sensor materials on sensor contamination are analyzed. Actions to be taken during transportation, storage, and testing of sensors to avoid contamination are discussed.

Hovis, W.↗

Optimization studies in the support design for the Large Space Telescope.

A two-stage computer-oriented process is described to design the optimum mirror supports for the NASA Large Space Telescope. Using an element model for the mirror, a set of support displacements is determined so as to minimize the rms optical surface disturbances with respect to a best-fit surface. The second stage uses the STRUDL II-STOP finite element optimization system (a branch and bound approach) to obtain a minimum weight design for the support structure subject to the displacement constraints.

Cella, A.↗

Partial performance degradation of a remote sensor in a space environment, and some probable causes

The Multispectral Scanner (MSS) was launched on the Earth Resources Technology Satellite (ERTS-1) on July 23, 1972. The MSS has two calibration systems, one internal and one external. Both calibration systems have shown strong, spectrally dependent performance degradation since launch. This paper presents details on the optical system of the MSS and data on the performance degradation as a function of both spectral interval and time in orbit. The history of the MSS during tests is traced, and it is shown that hydrocarbons from an external source may have been deposited on optical surfaces in the instrument. It is postulated that these contaminant coatings may have polymerized as a result of the exposure to UV light from the sun, increasing their blue absorbtion and accounting for the observed performance degradation.

Horan, J. J.↗

Skylab electronic technological advancements

The present work describes three electronic devices designed for use in the Skylab airlock module: the teleprinter system, the quartz crystal microbalance contamination monitor (QCM), and the speaker. Design considerations, operation, characteristics, and system development are described for these systems, with accompanying diagrams, graphs, and photographs. The teleprinter is a thermal dot printer used to produce hard copy messages by electrically heating print elements in contact with heat-sensitive paper. The QCM was designed to estimate contamination buildup on optical surfaces of the earth resources experiment package. A vibrating quartz crystal is used as a microbalance relating deposited mass to shifts in the crystal's resonant frequency. Audio devices provide communication between crew members and between crew and STDN, and also provide audible alarms, via the caution and warning system, of out-of-limit-conditions.

Hornback, G. L.↗

Optical grating analyzer studies

A spectrometer was specifically designed and developed to observe grating spectra over a range of incidence angles from normal to almost grazing incidence. A unique scanning and focusing mechanism is utilized to keep the exit slit on the Rowland circle. Polarization effects in the vacuum were investigated, and efficiency measurements and spectral scans were made simultaneously with the spectrometer. Results of measurements are given. Applications of the spectrometer to the space program and to the study of contamination on optical surfaces are indicated.

Mcdonald, J. K.↗

Skylab induced environment

This induced environment consists of particles and gases which emanate from the spacecraft in orbit and form the 'contamination cloud'. The presence of the cloud can present certain problems connected with scattering effects and the deposition of condensibles on optical surfaces. Measures taken to investigate these effects involved the placement of quartz crystal microbalance deposition monitors at certain locations to determine molecular film build-up during the flight.

Naumann, R. J.↗