Search NASA⌕ Search

SEARCH · Search NASA

Results for “technical evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

HEAT AND MASS TRANSFER IN HUMIDIFYING REGENERATOR FOR A SUB-ATMOSPHERIC HYBRID HEAT ENGINE

Heat and mass transfer processes in advanced modular sub-atmospheric hybrid heat engine have been evaluated for technical and economic feasibility. The presented concept combines fossil fuel energy conversion in a sub-atmospheric air turbine coupled with a reciprocating internal combustion engine to create a hybrid system for power generation. This system can achieve over 65% of net electrical or mechanical power conversion efficiency. The uniqueness of the advanced modular sub-atmospheric hybrid heat engine is in the operating conditions of the air turbine which operates at sub-atmospheric pressure and low temperature and produces power at high efficiency. This is possible due to a unique combination of the system components such as sub-atmospheric air turbine, humidifying air regenerator, and compressor inlet air cooling system. The humidifying air regenerator is the core component of the advanced sub-atmospheric turbine, which makes the turbine ultra-high efficient. It is a regenerative heat-mass exchanger to increase the working fluid (humid air) mass flow rate before the turbine and decrease the mass flow rate after the turbine. It is found that increased heat and mass transfer rate or increased air humidification in humidifying air regenerator would allow the turbine operating at lower temperature and increased efficiency. Optimal heat and mass transfer rates were found for higher efficiency, lower costs, and smaller footprint of the hybrid engine. The results of feasibility study of heat and mass transfer processes in the humidifying air regenerator are presented in this paper.

Heat Engine, Sub-atmospheric Turbine, Humidifying ↗

Fractionation of Lignocellulosic Biomass into High-Value Products - CRADA Report

Idaho National Laboratory (INL) has developed a process for adding value in the biomass feedstock supply chain. The key aspects of this process include: (1) anaerobic and chemical treatment of biomass during storage, (2) fractionation of biomass into conversion-ready feedstock and high-value coproducts, and (3) high-moisture pelleting to increase the bulk density and stabilize the feedstock. The purpose of the chemical treatment is to overcome the recalcitrant nature of the feedstock to improve the biochemical conversion process of breaking down the biomass into sugars. To maximize the utilization of the biomass, the feedstock can be fractionated into hemicellulose and lignin rich fractions. Finally, to increase the materials overall energy density, produce a shelf-stable material, and to facilitate transport, the feedstock is densified in a pelleting process. The first two steps of the processes have been verified at bench scale showing an improvement in theoretical glucose yield from 23.1% to 44.5% and an improvement in theoretical xylose yield from 8.9% to 23.1% from ground corn stover. It is hypothesized that densification will further increase the carbohydrate yield in the sample. The goal of this project was to evaluate the technical feasibility and process economics of the above process and to provide preliminary data to Golden Leaf Energy, Inc to access its potential commercialization for converting biomass to ethanol and renewable chemicals. Corn stover (CS), the largest available agricultural residue, and Chinese tallow (CT), an invasive wood species with no current commercial value, were chosen as feedstocks for this project.

09 BIOMASS FUELS↗

Publicly Available Molten Salt Data/Benchmarks

This presentation summarizes data for three molten salt reactors that has been made publicly available by Copenhagen Atomics. This information will be shared with the participants of the OECD/NEA International Reactor Physics Experiment Evaluation (IRPhE) Technical Review Group.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental factors affecting PCR-based estimates of microbial species richness and evenness

Pyrosequencing of 16S rRNA gene amplicons for microbial community profiling can, for equivalent costs, yield greater than two orders of magnitude more sensitivity than traditional PCR-cloning and Sanger sequencing. With this increased sensitivity and the ability to analyze multiple samples in parallel, it has become possible to evaluate several technical aspects of PCRbased community structure profiling methods. We tested the effect of amplicon length and primer pair on estimates of species richness number of species and evenness relative abundance of species by assessing the potentially tractable microbial community residing in the termite hindgut. Two regions of the 16S rRNA gene were sequenced from one of two common priming sites, spanning the V1-V2 or V8 regions, using amplicons ranging n length from 352 to 1443 bp. Our results demonstrate that both amplicon length and primer pair markedly influence estimates of richness and evenness. However, estimates of species evenness are consistent among different primer pairs targeting the same region. These results highlight the importance of experimental methodology when comparing diversity estimates across communities.

59 BASIC BIOLOGICAL SCIENCES↗

A Unified Testing Platform to Mature Blockchain Applications for Grid Emulation Environments

Blockchain technology is a relatively novel technology that can be used to develop more decentralized, autonomous and tamper-evident solutions. A feature that can aid Transactive Energy Systems to reach their goals by enabling individual actors to communicate and reach consensus with other participants in a more decentralized fashion. However, technical barriers to evaluate and adopt this type of technology within the electrical domain still exist. To facilitate this task, BLOSEM Unified Testing Platform (UTP), a DOE-sponsored, multi-lab effort intends to accelerate the development of solutions by offering a common set of reusable services that can be used to interconnect existent grid tools with blockchain services. UTP is intended to serve as development platform that can provide application engineers with the technical means to evaluate potential blockchain solutions, by enabling them to concentrate on the actual application functionalities while at the same time abstracting the connectivity and performance measurement tasks. The use of BLOSEM UTP is further demonstrated by implementing two potential use cases that are intended to validate both the feasibility of implementing these applications as blockchain-based solutions while also demonstrating the features provided by UTP.

blockchain co-simulation↗

Co-ordination of the International Network of Nuclear Structure and Decay Data Evaluators; Summary Report of an IAEA Technical Meeting

The IAEA Nuclear Data Section convened the 18th meeting of the International Network of Nuclear Structure and Decay Data Evaluators at the IAEA Headquarters, Vienna, 23 to 27 March 2009. This meeting was attended by 22 scientists from 14 Member States, plus IAEA staff, concerned with the compilation, evaluation and dissemination of nuclear structure and decay data. A summary of the meeting, recommendations/conclusions, data centre reports, and various proposals considered, modified and agreed by the participants are contained within this document. The International Network of Nuclear Structure and Decay Data (NSDD) Evaluators holds biennial meetings under the auspices of the IAEA, and consists of evaluation groups and data service centres in several countries. This network has the objective of providing up-to-date nuclear structure and decay data for all known nuclides by evaluating all existing experimental data. Data resulting from this international evaluation collaboration is included in the Evaluated Nuclear Structure Data File (ENSDF) and published in the journals Nuclear Physics A and Nuclear Data Sheets (NDS).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sludge Batch 10 (SB10) Acceptance Evaluation: Radionuclide Concentrations in Tank 51 Washed Qualification Sample

Savannah River National Laboratory (SRNL) has been tasked with the radionuclide characterization of the washed Sludge Batch 10 (SB10) qualification sample. The washed SB10 qualification sample is based on SRR Engineering guidance and the sample slurry is expected to be similar in composition to Tank 51 slurry after final preparations for transfer to Tank 40. Forty-four radionuclides along with total alpha and beta activity have been reported herein. These radionuclide measurements are required for the Defense Waste Processing Facility (DWPF) Radiological Evaluation Program, DWPF Technical Safety Requirements (TSR)/Waste Acceptance Criteria (WAC) Evaluation, and the DWPF Solid Waste Characterization Program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-134: Optimizing Technical Parameters for Using Atlas Based Automatic Segmentation for Evaluation of Contour Accuracy Experience with Cardiac Structures From NRG Oncology/RTOG 0617

Purpose: Accurate contour delineation is crucial for radiotherapy. Atlas based automatic segmentation tools can be used to increase the efficiency of contour accuracy evaluation. This study aims to optimize technical parameters utilized in the tool by exploring the impact of library size and atlas number on the accuracy of cardiac contour evaluation. Methods: Patient CT DICOMs from RTOG 0617 were used for this study. Five experienced physicians delineated the cardiac structures including pericardium, atria and ventricles following an atlas guideline. The consistency of cardiac structured delineation using the atlas guideline was verified by a study with four observers and seventeen patients. The CT and cardiac structure DICOM files were then used for the ABAS technique.To study the impact of library size (LS) and atlas number (AN) on automatic contour accuracy, automatic contours were generated with varied technique parameters for five randomly selected patients. Three LS (20, 60, and 100) were studied using commercially available software. The AN was four, recommended by the manufacturer. Using the manual contour as the gold standard, Dice Similarity Coefficient (DSC) was calculated between the manual and automatic contours. Five-patient averaged DSCs were calculated for comparison for each cardiac structure.In order to study the impact of AN, the LS was set 100, and AN was tested from one to five. The five-patient averaged DSCs were also calculated for each cardiac structure. Results: DSC values are highest when LS is 100 and AN is four. The DSC is 0.90±0.02 for pericardium, 0.75±0.06 for atria, and 0.86±0.02 for ventricles. Conclusion: By comparing DSC values, the combination AN=4 and LS=100 gives the best performance. This project was supported by NCI grants U24CA12014, U24CA180803, U10CA180868, U10CA180822, PA CURE grant and Bristol-Myers Squibb and Eli Lilly.

60 APPLIED LIFE SCIENCES↗

Evaluation Challenges for the Application of Extended Reality Devices in Medicine

Augmented and virtual reality devices are being actively investigated and implemented for a wide range of medical uses. However, significant gaps in the evaluation of these medical devices and applications hinder their regulatory evaluation. Addressing these gaps is critical to demonstrating the devices’ safety and effectiveness. We outline the key technical and clinical evaluation challenges discussed during the US Food and Drug Administration’s public workshop, “Medical Extended Reality: Toward Best Evaluation Practices for Virtual and Augmented Reality in Medicine” and future directions for evaluation method development. Evaluation challenges were categorized into several key technical and clinical areas. Finally, we highlight current efforts in the standards communities and illustrate connections between the evaluation challenges and the intended uses of the medical extended reality (MXR) devices. Participants concluded that additional research is needed to assess the safety and effectiveness of MXR devices across the use cases.

60 APPLIED LIFE SCIENCES↗

Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute

The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurred in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Status and Trend of Automotive Power Packaging

Comprehensive requirements in aspects of cost, reliability, efficiency, form factor, weight, and volume for power electronics modules in modern electric drive vehicles have driven the development of automotive power packaging technology intensively. Innovation in materials, interconnections, and processing techniques is leading to enormous improvements in power modules. In this paper, the technical development of and trends in power module packaging are evaluated by examining technical details with examples of industrial products. The issues and development directions for future automotive power module packaging are also discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Challenges for Deep Vadose Zone Remediation at the Hanford Site

The 'deep vadose zone' is defined as the region below the practical depth of surface remedy influence (e.g., excavation or barrier). At the Hanford Site, this region of the Central Plateau poses unique challenges for characterization and remediation. Currently, deep vadose zone characterization efforts and remedy selection are spread over multiple waste site Operable Units and tank farm Waste Management Areas. A particular challenge for this effort is the situation in which past leaks from single-shell tanks have become commingled with discharges from nearby liquid disposal sites. In addition, tests of potentially viable remediation technologies will be initiated in the next few years. The Hanford Site is working with all affected parties, including the Washington State Department of Ecology, the Environmental Protection Agency, DOE-RL, DOE-ORP, and multiple contractor organizations to develop remediation approaches. This effort addresses the complex and challenging technical and is evaluating the best strategy or combination of strategies for focusing technical investigations, including treatability studies to facilitate deep vadose zone remediation at the Hanford Site. In summary: Hanford's two DOE offices, Richland Operations and the Office of River Protection, are engaging the Site's regulators, EPA and the Washington State Department of Ecology, in a collaborative process to resolve one of Hanford's most challenging technical issues - investigation and remedy selection for the deep vadose zone. While this process has not reached its conclusion, several important findings are apparent. All parties agree that the current approach of addressing this problem is not likely to be successful and an alternative is needed. An essential initial step is to develop and then implement a deep vadose zone treatability test plan that logically organizes the testing of candidate technologies for application to the variety of Hanford's deep vadose zone problems. This plan is currently under development. The deep vadose zone needs to be addressed through a 'project-like' focused and high priority effort. Currently, there is a very diffuse focus to this problem. There are roughly 30 to 50 waste sites, multiple operable units and seven tank farm WMAs that may have to address deep vadose zone issues. No single waste site or investigation can adequately take on this Plateau-wide problem. Investigations of regions with commingled plumes from tank farms and non-tank farm sources need to be integrated or closely coordinated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Fuels Campaign Light Water Reactor Accident Tolerant Fuel Performance Metrics Executive Summary

Research and development (R&D) activities on advanced, higher performance Light Water Reactor (LWR) fuels have been ongoing for the last few years. Following the unfortunate March 2011 events at the Fukushima Nuclear Power Plant in Japan, the R&D shifted toward enhancing the accident tolerance of LWRs. Qualitative attributes for fuels with enhanced accident tolerance, such as improved reaction kinetics with steam resulting in slower hydrogen generation rate, provide guidance for the design and development of fuels and cladding with enhanced accident tolerance. A common set of technical metrics should be established to aid in the optimization and down selection of candidate designs on a more quantitative basis. “Metrics” describe a set of technical bases by which multiple concepts can be fairly evaluated against a common baseline and against one another. This report describes a proposed technical evaluation methodology that can be applied to evaluate the ability of each concept to meet performance and safety goals relative to the current UO2 – zirconium alloy system and relative to one another. The resultant ranked evaluation can then inform concept down-selection, such that the most promising accident tolerant fuel design option(s) can continue to be developed toward qualification.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Unified Testing Platform to Mature Blockchain Applications for Grid Emulation Environments: Preprint

Blockchain technology is a relatively novel technology that can be used to develop more decentralized, autonomous and tamper-evident solutions. A feature that can aid Transactive Energy Systems to reach their goals by enabling individual actors to communicate and reach consensus with other participants in a more decentralized fashion. However, technical barriers to evaluate and adopt this type of technology within the electrical domain still exist. To facilitate this task, BLOSEM Unified Testing Platform (UTP), a DOE-sponsored, multi-lab effort intends to accelerate the development of solutions by offering a common set of reusable services that can be used to interconnect existent grid tools with blockchain services. UTP is intended to serve as development platform that can provide application engineers with the technical means to evaluate potential blockchain solutions, by enabling them to concentrate on the actual application functionalities while at the same time abstracting the connectivity and performance measurement tasks. The use of BLOSEM UTP is further demonstrated by implementing two potential use cases that are intended to validate both the feasibility of implementing these applications as blockchain-based solutions while also demonstrating the features provided by UTP.

blockchain↗