Search NASA⌕ Search

SEARCH · Search NASA

Results for “test case”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Applying DER-CAM for IIT Microgrid Explansion Planning

The Distributed Energy Resources Customer Adoption Model (DER-CAM) is an economic and environmental model of customer DER adoption. This model has been in development at the Lawrence Berkeley National Laboratory since 2000. The objective of the model is to find optimal DER investments while minimizing total energy costs or carbon dioxide (CO2) emissions, or achieving a weighted objective that simultaneously considers both criteria. The Illinois Institute of Technology (IIT) Microgrid project started in August 2008, and the majority of the project was completed in May 2013. IIT Microgrid, funded mostly by a grant from the U.S. Department of Energy as well as State and philanthropic contributions, empowers the campus consumers with the objective of establishing a smart microgrid that is highly reliable, economically viable, environmentally friendly, fuel-efficient, and resilient in extreme circumstances with a self-healing capability. In this project, we apply DER-CAM to study the expansion planning of the IIT Microgrid. First, the load data, environmental data, utility data, and technology data for the IIT Microgrid are gathered and organized to follow the DER-CAM input requirements. Then, DERCAM is applied to study the expansion planning of the IIT Microgrid for different cases, where different objectives in DER-CAM and different utility conditions are tested. Case 1 considers the objective of minimizing energy costs with fixed utility rates and 100% electric utility availability. Case 2 considers the objective of minimizing energy costs with real-time utility rates and 4 emergency weeks when the IIT Microgrid does not have access to the electric utility grid and has to operate in island mode. In Case 3, the utility rates are restored to fixed values and 100% electric utility availability is assumed, but a weighted multi-objective (Obj: a × costs + b × CO2 emissions, where a and b are weights for cost minimization and CO2 emissions minimization) is utilized to consider both energy costs and CO2 emissions. On the basis of the test results, the IIT Microgrid has the potential to benefit from investments in more DER technologies. The current annual energy costs and CO2 emissions for the IIT Microgrid are 6,495.1 k$ and 39,838.5 metric tons, respectively. This represents the baseline for this project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Seismic modeling with radial basis function-generated finite differences (RBF-FD) – a simplified treatment of interfaces

In a previous study of seismic modeling with radial basis function-generated finite differences (RBF-FD), we outlined a numerical method for solving 2-D wave equations in domains with material interfaces between different regions. The method was applicable on a mesh-free set of data nodes. It included all information about interfaces within the weights of the stencils (allowing the use of traditional time integrators), and was shown to solve problems of the 2-D elastic wave equation to 3rd-order accuracy. In the present paper, we discuss a refinement of that method that makes it simpler to implement. It can also improve accuracy for the case of smoothly-variable model parameter values near interfaces. We give several test cases that demonstrate the method solving 2-D elastic wave equation problems to 4th-order accuracy, even in the presence of smoothly-curved interfaces with jump discontinuities in the model parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-E-T-49: Automatic Beam Angle Determination for Lung IMRT Planning Using a Beam Configuration Atlas

Purpose: To present a technique to automatically determine beam angle configurations for lung IMRT planning based on the patient-specific anatomy and tumor geometry. Methods: The relationship between individual patient anatomy and proper beam configurations was learned from high quality clinical plans in three steps. First, a beam configuration atlas was obtained by classifying 60 lung IMRT plans into 6 beam configuration clusters based on a dissimilarity measure defined between different beam configurations. A beam configuration template was extracted from each cluster to form an atlas. Second, a beam efficiency index map (EI map) was constructed to characterize the geometry of the tumor relative to the lungs, the body and other OARs along each candidate beam direction. Finally, the EI maps of the clinical cases and the cluster assignments of their beam configurations were paired to train a Bayesian classification model. This technique was validated by leave-one-out cross validation with 16 cases randomly selected from the original dataset. An IMRT plan (autobeam plan) for each test case was generated using the beam configuration template according to the cluster assignment given by the model and was compared with the corresponding clinical plan. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) in the auto-beam plans and in the clinical plans, respectively, and the p-values by a paired ttest (in parenthesis) are: lung Dmean: 16.3±9.3, 18.6±7.4 (0.48), esophagus Dmean: 28.4±18, 30.7±19.3 (0.02), Heart Dmean: 21.5±17.5,21.1±17.2 (0.76), Spinal Cord D2%: 48±23, 51.2±21.8 (0.01), PTV dose homogeneity (D2%–D99%): 22±27.4, 20.4±12.8 (0.10).The dose reductions by the autobeam plans in esophagus Dmean and cord D02 are statistically significant but the differences (<4%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: Plans generated by the automatic beam angle determination method can achieve dosimetric quality equivalent to that of clinical plans. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

60 APPLIED LIFE SCIENCES↗

The Effects of Electrostatic Discharge Phenomena on Detonator Response: A Framework for Evaluating Parameters Relevant to Quantification of Margins and Uncertainties

Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Pantex are collaborating on a Nuclear Safety Research & Development (NSR&D) project to develop a common Quantification of Margins and Uncertainties (QMU) framework for explosive safety analysis. An analysis of electrostatic discharge (ESD) data serves as an initial test case for methodology development. This analysis examines measurements of electrical characteristics of production environments, tests designed to measure ESD response of detonators, and information on interactions between variables drawn from expert knowledge and physics models.

42 ENGINEERING↗

Application of power time-projection on the operator-splitting coupling scheme of the TRACE/S3K coupled code

This paper reports refinement studies on the temporal coupling scheme and time-stepping management of TRACE/S3K, a dynamically coupled code version of the thermal-hydraulics system code TRACE and the 3D core simulator Simulate-3K. The studies were carried out for two test cases, namely a PWR rod ejection accident and the Peach Bottom 2 Turbine Trip Test 2. The solution of the coupled calculation, especially the power peak, proves to be very sensitive to the time-step size with the currently employed conventional operator-splitting. Furthermore, a very small time-step size is necessary to achieve decent accuracy. This degrades the trade-off between accuracy and performance. A simple and computationally cheap implementation of time-projection of power has been shown to be able to improve the convergence of the coupled calculation. This scheme is able to achieve a prescribed accuracy with a larger time-step size. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Technical Report: Moving ASR Cloud Microphysical Retrievals Beyond the Vertical Column

Clouds of all types play important roles in atmospheric heating, surface heating and emission of radiation, hence energy, to space. Clouds not only affect atmospheric heating via their impacts on solar and terrestrial radiation, they also release kinetic energy to the atmosphere when they form and they extract kinetic energy from the atmosphere when they evaporate. To understand the impacts of clouds on weather and climate, one must be able to make accurate observations of the amount of water associated with them and the impact of this water on atmospheric and surface heating rates. One important cloud type is liquid water clouds. Liquid clouds are often found in the boundary layers of Earth at altitudes from just above the surface to approximately 2000 m above it, at a variety of temperatures, including temperatures below the freezing point of liquid water (0 °C). As a result, they are important constituents over the world’s oceans as well as over cold, ice-covered surfaces such as in the Arctic. Observationally estimating the total amount of liquid contained in a column through a liquid water cloud can now be accomplished to acceptable accuracies (except for the thinnest, lowest liquid containing clouds) using instruments called passive microwave radiometers. However, observationally determining the spatial distribution of liquid within these columns has proven to be difficult. The focus of this project was on the application of two radars operating at two different frequencies to retrieve the distribution of liquid water within columns passing through liquid water clouds. Motivation in this project for using two different radars operating at different frequencies is that as overlapping (in space) beams from the two radars pass through the same column of liquid water cloud absorption of power from one beam (the 94-GHz beam) is greater than absorption of power from the other beam (the 35-GHz beam). Therefore, the difference in returned powers between the two radar beams with distance from the radars is proportional to the amount of liquid water that the two beams have passed through. Therefore, one can use the differences in power between the two beams with distance through a liquid water cloud to determine the distribution of liquid water throughout the cloud. The two radars used in this study are the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Program Ka-band Scanning ARM Cloud Radar (Ka-SACR) and the W-band Scanning ARM Cloud Radar (W-SACR). When this projected started in 2013, the Ka- and W-band SACRs were new technology, state-of-the-art sensors. To put together a sufficiently diverse and big set of test cases for the study, data from the SACRs deployed to NSA, SGP, TCAP and MAGIC were used, leading to a test set composed of 65 hours of suitable data spread over approximately 17 case study days. Using the Ka- and W-band SACR data from the case study periods, vertical distributions of liquid water content through liquid water clouds were retrieved. Because there are no other data sets with which to compare the retrievals, distributions of liquid water through a column were summed and compared to the total amounts of liquid water obtained by retrievals applied to passive microwave radiometer observations. The total amounts of liquid water (in units of millimeters, or the thickness in millimeters of the total liquid water in a vertical column if allowed to pool at the bottom of the column) between the two retrievals agreed to within 0.060 mm with a standard deviation of 0.31 mm, or to within 0.016 mm with a standard deviation of 0.12 mm once outliers were removed. The standard deviation of 0.12 mm was fairly independent of the total amount of liquid water in the clouds, indicating that retrieval errors were larger for clouds with smaller amounts of liquid in them. Errors in the retrieved total amounts of liquid were also found to be sensitive to the a priori information that was fed into the retrieval approach. Overall, standard deviations of 0.12 mm are sufficient for some cloud studies but for radiation studies standard deviations on the order of 0.02 mm need to be achieved for clouds with the lowest amounts of liquid water. Many modifications to the retrieval approach were tested subsequently in an attempt to reduce the standard deviations relative to the radiometer retrievals below 0.12 mm but none of them worked reliably. We decided to wait until the DOE ARM Program deployed its second generation SACR2s to its NSA and ENA sites for further retrieval evaluation. The SACR2s were engineered to better synchronize data between the Ka- and W-band radars, reducing potential sources of noise for radar retrieval of liquid water distributions within clouds. The SACR2s have improved in reliability recently and the system deployed to ENA is best positioned to provide the data to advance research on this path. This will be an ongoing research activity beyond the project because of the promise in SACR2 data from the DOE ARM ENA Facility.

58 GEOSCIENCES↗

SU-E-T-349: Verification of a Monte Carlo Simulation Tool as a Second Check for TomoTherapy Treatment Planning

Purpose: To verify a virtual source model used in Monte Carlo (MC) TomoTherapy simulations and to provide a tool for the dose distribution second check for TomoTherapy treatment planning. Methods: Published studies adopted the full MC model to simulate helical TomoTherapy which use phase space files (PSFs) at different scoring planes to facilitate patient dose calculations. We have developed a simple virtual source model (VSM) based on the commissioning data of helical TomoTherapy unit which can be exported from the treatment planning station (TPS). To calculate the patient dose distribution, TPS-generated sinograms are extracted from archived patient XML files and fluence maps are created by incorporating the openclose leaf time with leaf filter, jaw penumbra, and leaf latency. The VSM has been validated for various geometrical set-ups including open fields, heterogeneous media and clinical DQA cases. Results: Good agreement was obtained between our VSM and a published full MC model for the test case of heterogeneous media. For the complex clinical head and neck (HN) case, the MC simulation of the DQA plan agreed with the film measurement with 98% of planar dose pixels passing the 2%/2 mm gamma value test. For the patient treatment plan itself, the MC simulation showed comparable DVHs for the planning target volumes (PTVs) and organs-at-risk (OARs). Deviations observed were consistent with literature. Conclusion: The proposed VSM can be used in the MC method to accurately simulate the patient dose distributions for helical TomoTherapy.

60 APPLIED LIFE SCIENCES↗

Fourier-informed knot placement schemes for B-spline approximation

Fitting B-splines to scientific data is especially challenging when the given data contain noise, jumps, or corners. Here, we describe how periodic data sets with these features can be efficiently approximated with B-splines by analyzing the Fourier spectrum of the data. Our method uses a collection of spectral filters to compute high-order derivatives, smoothed versions of noisy data, and the locations of jump discontinuities. Further, these quantities are then combined to choose knots that capture the qualitative features of the data, leading to accurate B-spline approximations with few knots. The method we introduce is direct and does not require any intermediate B-spline fitting before choosing the final knot distribution. Aside from fast Fourier transforms to transfer to and from Fourier space, the method runs in linear time with very little communication. We assess performance on several test cases in one and two dimensions, including data sets with jump discontinuities and noise. These tests show the method fits discontinuous data without spurious oscillations and remains effective in the presence of noise.

97 MATHEMATICS AND COMPUTING↗

Intercode comparison of gyrokinetic global electromagnetic modes

Aiming to fill a corresponding lack of sophisticated test cases for global electromagnetic gyrokinetic codes, a new hierarchical benchmark is proposed. Starting from established test sets with adiabatic electrons, fully gyrokinetic electrons, and electrostatic fluctuations are taken into account before finally studying the global electromagnetic micro-instabilities. Results from up to five codes involving representatives from different numerical approaches as particle-in-cell methods, Eulerian and Semi-Lagrangian are shown. By means of spectrally resolved growth rates and frequencies and mode structure comparisons, agreement can be confirmed on ion-gyro-radius scales, thus providing confidence in the correct implementation of the underlying equations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing DER Participation in Inertial and Primary-Frequency Response

This paper develops an approach to enable the optimal participation of distributed energy resources (DERs) in inertial and primary-frequency response alongside conventional synchronous generators. Leveraging a reduced-order model description of frequency dynamics, DERs' synthetic inertias and droop coefficients are designed to meet time-domain performance objectives of frequency overshoot and steady-state regulation. Furthermore, an optimization-based method centered around classical economic dispatch is developed to ensure that DERs share the power injections for inertial- and primary-frequency response in proportion to their power ratings. Simulations for a modified New England test-case system composed of ten synchronous generators and six instances of the IEEE 37-node test feeder with frequency-responsive DERs validate the design strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27{+-}52.97 to 14.98 mm{+-}11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation-based Testing of Control Software

It is impossible to adequately test complex software by examining its operation in a physical prototype of the system monitored. Adequate test coverage can require millions of test cases, and the cost of equipment prototypes combined with the real-time constraints of testing with them makes it infeasible to sample more than a small number of these tests. Model based testing seeks to avoid this problem by allowing for large numbers of relatively inexpensive virtual prototypes that operate in simulation time at a speed limited only by the available computing resources. In this report, we describe how a computer system emulator can be used as part of a model based testing environment; specifically, we show that a complete software stack including operating system and application software - can be deployed within a simulated environment, and that these simulations can proceed as fast as possible. To illustrate this approach to model based testing, we describe how it is being used to test several building control systems that act to coordinate air conditioning loads for the purpose of reducing peak demand. These tests involve the use of ADEVS (A Discrete Event System Simulator) and QEMU (Quick Emulator) to host the operational software within the simulation, and a building model developed with the MODELICA programming language using Buildings Library and packaged as an FMU (Functional Mock-up Unit) that serves as the virtual test environment.

97 MATHEMATICS AND COMPUTING↗

Development of programmable logic in a rapid, automated, and repeatable fashion for safety-related applications - 385

Digital safety platform considerations for power plant modernization or new build efforts involve a burdensome task of implementing a large number of software-based functions onto a designated platform to match the plant's architecture. This problem is not unique to any particular safety-related platform solution, but is prevalent across the landscape of current Qualified and Licensed Safety-related Instrumentation and Control (I and C) Solutions. As an example when implementing a RG 1.97 compliant Post Accident Monitoring System (PAMS) solution with the Lockheed Martin Nuclear Protection and Control (NuPAC) safety platform, 72 unique software loads are needed to configure the Qualified Display System (QDS). Large scale development and customization efforts to upgrade existing plant functions or systems require the licensee to assume the cost and technical risk necessary to undergo a digital based upgrade. Often the cost, schedule, and technical risk outweighed the benefit of modernization efforts due to the unknown hurdles and past projects that overran cost and schedule projections. Lockheed Martin's Engineering Production Suite (EPS) minimizes the licensee risk and expense associated with modernization efforts through a developer's toolkit for rapid, automated, and repeatable development of Programmable Logic used to implement plant functions and architectures for use on the Lockheed Martin NuPAC platform. This paper describes a use case where by EPS can create system level representations, simulate system functions, partition logic designs to accommodate hardware constraints through logic partitioning, automate the assembly of Application Specific Programmable Logic (ASPL), generate system test cases, program the NuPAC hardware, and perform testing throughout the design workflow. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Life cycle assessment based environmental impact estimation model for pre-stressed concrete beam bridge in the early design phase

The late rise in global concern for environmental issues such as global warming and air pollution is accentuating the need for environmental assessments in the construction industry. Promptly evaluating the environmental loads of the various design alternatives during the early stages of a construction project and adopting the most environmentally sustainable candidate is therefore of large importance. Yet, research on the early evaluation of a construction project's environmental load in order to aid the decision making process is hitherto lacking. In light of this dilemma, this study proposes a model for estimating the environmental load by employing only the most basic information accessible during the early design phases of a project for the pre-stressed concrete (PSC) beam bridge, the most common bridge structure. Firstly, a life cycle assessment (LCA) was conducted on the data from 99 bridges by integrating the bills of quantities (BOQ) with a life cycle inventory (LCI) database. The processed data was then utilized to construct a case based reasoning (CBR) model for estimating the environmental load. The accuracy of the estimation model was then validated using five test cases; the model's mean absolute error rates (MAER) for the total environmental load was calculated as 7.09%. Such test results were shown to be superior compared to those obtained from a multiple-regression based model and a slab area base-unit analysis model. Henceforth application of this model during the early stages of a project is expected to highly complement environmentally friendly designs and construction by facilitating the swift evaluation of the environmental load from multiple standpoints. - Highlights: • This study is to develop the model of assessing the environmental impacts on LCA. • Bills of quantity from completed designs of PSC Beam were linked with the LCI DB. • Previous cases were used to estimate the environmental load of new case by CBR model. • CBR model produces more accurate estimations (7.09%) than other conventional models. • This study supports decision making process in the early stage of a new construction case.

54 ENVIRONMENTAL SCIENCES↗

IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119

AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit=|mean|+1.96{sigma}. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.

61 RADIATION PROTECTION AND DOSIMETRY↗