Search NASASearch

SEARCH · Search NASA

Results for “thermal nondestructive evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,140 records · Page 19

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

Early Progress Toward the Feasibility of the Centrifugal Nuclear Thermal Rocket

The Centrifugal Nuclear Thermal Rocket (CNTR) is a Nuclear Thermal Propulsion (NTP) concept designed to heat propellant directly by the reactor fuel. The primary difference between the CNTR concept and traditional NTP systems is that rather than using traditional solid fuel elements, the CNTR uses liquid fuel with the liquid contained in rotating cylinders by centrifugal force. If the concept can be successfully realized, the CNTR would have a high specific impulse (~1800 seconds) at high thrust, which may enable (i) viable near-term human Mars exploration by reducing round-trip times to 420 days and (ii) direct injection orbits for scientific missions to the Solar System outer planets and potentially Kuiper Belt objects. The CNTR could also use storable propellants such as ammonia, methane, or hydrazine at an Isp of ~900 seconds, enabling long-term in-space storage of a dormant system. Significant engineering challenges must be addressed to establish the technical viability of the CNTR. Research is presently underway to determine resolutions for these engineering challenges. In particular, research has begun on the analytical modeling and simulation of the two-phase heat transfer between the liquid metallic uranium fuel and the gaseous propellant. A paper was presented at the 2021 IAC which described these challenges and the study plan to address them. This paper describes the analytical and experimental progress to date toward resolving these challenges and establishing the engineering feasibility of the CNTR technology.

Nuclear Thermal Propulsion

Development of the METMAN Thermal Desktop Human Model for System Integration

Human thermal analysis and model development inform NASA’s space suit development, vehicle/habitat design, and survivability studies. Historically, human thermal models such as the 41-node metabolic man (METMAN) and the Wissler model have been standalone software tools developed with FORTRAN, a programming language known for its high performance in computationally intensive applications. Though efficient, these standalone programs pose challenges to coupled human-system analysis with detailed life support and thermal control subsystem models in other commercial software. This paper describes the conversion of the METMAN human thermal model from a standalone FORTRAN program to a model in Thermal Desktop (Ansys), a commonly used CAD-based simulation software for engineering that specializes in heat transfer, thermal radiation, and fluid flow analysis. This format was chosen to best facilitate model sharing and compatibility, enabling the direct integration of METMAN human thermal analysis with subsystem models across NASA programs and commercial partners.

Elizabeth Thurston

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor

A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.

Propylene Glycol Water

PROTECT: Production and Reuse of Thermally Efficient Ceramic Thermal Protection Systems

PROTECT (Production and Reuse Of Thermally Efficient Ceramic TPS) is a NASA Early Career Initiative focused on developing the next generation of reusable ceramic thermal protection systems (TPS). This project addresses key challenges in TPS design, including temperature capability, thermal stability, and refurbishment time, by integrating novel material development with predictive modeling. Leveraging enhanced capabilities in NASA’s Porous Microstructure Analysis (PuMA) software, PROTECT introduces new modeling tools to predict the thermal and mechanical behavior of fibrous ceramic materials. These tools enable accurate prediction of performance metrics such as thermal conductivity and structural integrity, reducing reliance on costly physical testing. Preliminary advances in these areas will be presented. To support model validation, PROTECT is building a comprehensive database of raw material properties using advanced characterization techniques, including micro computed tomography (CT) scanning in collaboration with the University of Illinois Urbana-Champaign (UIUC). The presentation will detail the sampling workflows and analysis methods used to generate this detailed microstructural data and how it is used to develop improved models in PuMA. This multi-center collaboration, spanning NASA (JSC, ARC, KSC, GRC), Oak Ridge National Laboratory, UIUC, and SpaceX, is developing tailored TPS solutions for LEO, lunar, and Martian missions. By bridging heritage systems with the demands of modern spaceflight, PROTECT contributes to the advancement of reusable TPS technologies for future exploration missions.

Propulsion, Refractory, and Coating Materials

Preliminary Plan to Inform Testing of a Heat Exchanger Test Article

This report presents a preliminary plan to guide the qualification testing of advanced heat exchanger (HX) components for nuclear-to-industrial heat transfer applications. The objective is to establish a defensible, physics-based methodology that integrates computational modeling, targeted experimentation, and in-service inspection considerations to demonstrate component performance and reliability under representative reactor conditions. The analysis identifies Sodium-cooled Fast Reactor (SFR) and High-Temperature Gas-cooled Reactor (HTGR) systems as reference configurations in terms of temperature, pressure, and chemical environment. Within these operating envelopes, dominant degradation mechanisms— including creep–fatigue interaction, flow-induced vibration, corrosion, and diffusion-bond deterioration—were evaluated to define test requirements. A comprehensive computationalexperimental framework is proposed to support life prediction and qualification activities. The framework couples high-fidelity structural-mechanics, thermal-hydraulic, and fluid-structure interaction models with accelerated degradation testing to produce a traceable linkage between microstructural evolution, mechanical performance, and remaining useful life (RUL). The approach adheres to established Verification, Validation, and Uncertainty Quantification (VVUQ) standards (ASME V&V 10/20; NUREG-2152) and incorporates a digital-twin architecture for continuous model refinement through data assimilation. The plan further outlines testing methodologies, including pre-test analyses, test-loop design parameters, and sensor placement strategies that maximize information yield while maintaining mechanistic fidelity. Complementary sections describe in-service inspection (ISI), on-line monitoring (OLM), and structural-health-monitoring (SHM) techniques applicable to compact HX geometries typical of advanced reactors. Collectively, these activities establish the technical foundation for demonstrating 40-60-year equivalent service life of advanced heat exchangers in support of the U.S. Department of Energy’s Advanced Reactor and Integrated Energy Systems programs. The forthcoming phase will execute the defined pre-test analyses, initiate hardware fabrication, and implement the integrated testing campaign to validate the proposed qualification methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Passive continuous variable quantum key distribution scheme using a thermal source

A passive continuous variable quantum key distribution scheme, where Alice splits the output of a thermal source into two beams, measures one locally and transmits the other mode to Bob after applying attenuation. A secure key can be established based on measurements of the two beams without the use of a random number generator or an optical modulator.

Qi, Bing