Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

All-electrical time-resolved spin generation and spin manipulation in n-InGaAs

We demonstrate all-electrical spin generation and subsequent manipulation by two successive electric field pulses in an n-InGaAs heterostructure in a time-resolved experiment at zero external magnetic field. The first electric field pulse along the [11{sup ¯}0] crystal axis creates a current-induced spin polarization (CISP) which is oriented in the plane of the sample. The subsequent electric field pulse along [110] generates a perpendicular magnetic field pulse leading to a coherent precession of this spin polarization with 2-dimensional electrical control over the final spin orientation. Spin precession is probed by time-resolved Faraday rotation. We determine the build-up time of CISP during the first field pulse and extract the spin dephasing time and internal magnetic field strength during the spin manipulation pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of dipole- and valence bound anions in iodide-adenine binary complexes: A time-resolved photoelectron imaging and quantum mechanical investigation

Dipole bound (DB) and valence bound (VB) anions of binary iodide-adenine complexes have been studied using one-color and time-resolved photoelectron imaging at excitation energies near the vertical detachment energy. The experiments are complemented by quantum chemical calculations. One-color spectra show evidence for two adenine tautomers, the canonical, biologically relevant A9 tautomer and the A3 tautomer. In the UV-pump/IR-probe time-resolved experiments, transient adenine anions can be formed by electron transfer from the iodide. These experiments show signals from both DB and VB states of adenine anions formed on femto- and picosecond time scales, respectively. Analysis of the spectra and comparison with calculations suggest that while both the A9 and A3 tautomers contribute to the DB signal, only the DB state of the A3 tautomer undergoes a transition to the VB anion. The VB anion of A9 is higher in energy than both the DB anion and the neutral, and the VB anion is therefore not accessible through the DB state. Experimental evidence of the metastable A9 VB anion is instead observed as a shape resonance in the one-color photoelectron spectra, as a result of UV absorption by A9 and subsequent electron transfer from iodide into the empty π-orbital. In contrast, the iodide-A3 complex constitutes an excellent example of how DB states can act as doorway state for VB anion formation when the VB state is energetically available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A time-resolved spectroscopic diagnostic based on fast scintillator and optical fiber array for z-pinch plasmas

We report a specially designed type of temporal resolved x-ray spectroscopic diagnostic using a spherically bent quartz crystal for z-pinch plasmas. Registration of time-resolved spectra was accomplished by coupling fast plastic scintillator, an optical fiber array, an optical streak camera, and a charge coupled device as the recording medium of this diagnostic. The diagnostic has been tested in imploding wire array experiments on S-300 pulsed power facility. Time-resolved K-shell lines were successfully obtained for aluminum wire array implosion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Simulations of Time-Resolved Photoluminescence in CdSexTe1-x/CdTe Solar Cells

We present initial time-resolved photoluminescence (TRPL) simulations in graded CdSexTe1-e thin-film solar cells to quantify the front-interface recombination velocity, S int,front . Our model includes several composition dependences: bandgap energy, absorption coefficient, electron affinity, and carrier lifetime. Cathodoluminescence spectrum imaging measurements on bevels provide an estimate of the bandgap and the CdSe x Te 1-x alloy composition through the absorber thickness. TRPL decays are simulated as a function of the laser power, S int,front , front-interface band offset, and bulk Shockley-Read-Hall lifetime. We find the impact of S intf,ront on the PL decay increases as the band offset shifts from a "spike" to a "cliff". Recombination rate analysis shows that back-interface recombination could potentially dictate the later part of the TRPL decay "t 2" in high-lifetime CdSe x Te 1-x cells. We briefly discuss ongoing work to determine TRPL measurement conditions that maximize sensitivity to S itnt,front.

CdTe solar cells↗

Time-Resolved Research at the Advanced Photon Source Beamline 7-ID

The Sector 7 undulator beamline (7-ID) of the Advanced Photon Source (APS) is dedicated to time-resolved x-ray research and is capable of ultrafast measurements on the order of 100 ps. Beamline 7-ID has a laser laboratory featuring a Ti:Sapphire system (average power of 2.5W, pulse duration <50 fs, repetition rate 1-5 kHz) that can be synchronized to the bunch pattern of the storage ring. The laser is deliverable to x-ray enclosures, which contain diffractometers, as well as motorized optical tables for table-top experiments. Beamline 7-ID has a single APS Undulator A and uses a diamond (111) double-crystal monochromator, providing good energy resolution over a range of 6-24 keV. Available optics include Kirkpatrick-Baez (KB) mirrors to microfocus the x-ray beam. A variety of time-resolved diffraction and spectroscopy research is available at 7-ID, with experiments being done in the atomic, molecular, optical, chemistry, and solid state (bulk and surface) fields.

43 PARTICLE ACCELERATORS↗

Velocity distribution function of sputtered Cu atoms obtained by time resolved optical absorption spectroscopy

A new method based on time resolved optical absorption spectroscopy is proposed to determine the velocity distribution function of sputtered Cu atoms in a magnetron plasma discharge. The method consists of applying a short pulse of 1.5 {mu}s and of recording time variations in copper atom density in off pulse at different positions (1, 2, and 3 cm) from target surface under 3-30 mTorr. The time evolution of the density is then converted into velocity distribution. We estimate that only sputtered atoms with radial velocity component lower than 0.5 km/s are detected. The average velocity of Cu atoms is evaluated as the first order moment of the velocity distribution functions. The velocity distribution functions become the more dispersive the farther from target surface. The average velocities vary in the range of 2.5-3 km/s at the vicinity of target surface whereas at 3 cm a decrease from 2.5 to 1.2 km/s is observed at 30 mTorr.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved imaging of millimeter waves using visible continuum from the positive column of a Cs-Xe dc discharge

We present a high-sensitivity technique for time-resolved imaging of millimeter waves (MMWs) using the visible continuum (VC) from the positive column (PC) of a medium-pressure Cs-Xe dc discharge. For the MMW imaging application, a uniform plasma slab of the PC of a Cs-Xe discharge with 10x8 cm{sup 2} aperture and 2 cm in thickness was generated for 45 Torr xenon. The imaging technique is based on the fact that the intensity of the e-Xe bremsstrahlung continuum from the PC increases in the visible region when the electrons in the plasma are heated by MMWs. It is shown that in the MMW intensity range from zero to the threshold of the microwave-induced plasma breakdown, the intensity of the VC from the PC of a Cs-Xe discharge increases approximately as a second-order polynomial function of the MMW intensity. The obtained experimental data agree well with our calculations of the dependence of the VC intensity on electron temperature. The Ka-band MMW field patterns at the output of conical horn antennas and in the quasioptical beam were imaged using the discharge technique. It is shown that the technique can be used for time-resolved measurement of the profiles of watt- and subwatt-level MMWs. An energy flux sensitivity of the technique of about 10 {mu}J/cm{sup 2} in the Ka-band was demonstrated. The temporal resolution of the technique is about 0.8 {mu}s. Our modeling of the transient behavior of the electron temperature in the PC shows that the time history of the electron temperature variation coincides well with the measured time history of the VC intensity variation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ characterization of femtosecond laser-induced crystallization in borosilicate glass using time-resolved surface third-harmonic generation

Coherent phonon dynamics in condensed-phase medium are responsible for important material properties including thermal and electrical conductivities. We report a structural dynamics technique, time-resolved surface third-harmonic generation (TRSTHG) spectroscopy, to capture transient phonon propagation near the surface of polycrystalline CaF{sub 2} and amorphous borosilicate (BK7) glass. Our approach time-resolves the background-free, high-sensitivity third harmonic generation (THG) signal in between the two crossing near-IR pulses. Pronounced intensity quantum beats reveal the impulsively excited low-frequency Raman mode evolution on the femtosecond to picosecond timescale. After amplified laser irradiation, danburite-crystal-like structure units form at the glass surface. This versatile TRSTHG setup paves the way to mechanistically study and design advanced thermoelectrics and photovoltaics.

36 MATERIALS SCIENCE↗

Combined single-pulse holography and time-resolved laser schlieren for flow visualization

A pulsed ruby laser and continuous-wave argon ion laser were used in a combined setup at the Langley Expansion Tube for single pulse holography and time resolved laser schlieren with a common optical axis. The systems can be operated simultaneously for a single run. For a single frame, the pulsed holographic setup offers the options of shadowgraph, Schlieren, and interferometry from the reconstructed hologram as well as the advantage of post-run sensitivity adjustments. For flow establishment studies the time resolved laser Schlieren provides visualization of the flow field every 12.5 microns for up to 80 frames with an exposure time per frame of 5.4 microns.

Burner, A. W.↗

Preliminary Studies of UV Photolysis of Gas-phase CH3I in Air: Time-resolved Infrared Identification of Methanol and Formaldehyde Products

Halogen-bearing compounds are known to photolyze under UV radiation; analysis of degradation products is of interest for both safety and environmental considerations. Time-resolved infrared spectroscopy was used in the laboratory to study the UV-photolysis of methyl iodide. Photolysis products methanol (CH3OH) and formaldehyde (HCHO) were clearly identified in a time-resolved manner. Preliminary kinetic models predict the formation of both CH3OH and HCHO.

Hughey, Kendall D.↗

Testing the Physical Mechanisms of Gamma-Ray Bursts with Multi-Instrument Time-Resolved Spectroscopy

We have continued the project of time-resolved spectral analyses of gamma-ray bursts observed jointly by the BATSE and the Wide-Field Camera on board BeppoSAX. We are making progress understanding the systematic differences between the two data sets. These data comprise the most important joint analysis set for our project. In several meetings, we have reported on metal efforts to understand the blackbody portion of the time series of spectra from GRB970111. Clearly, a fading thermal component can provide a 'seed' spectrum for Compton upscattering. It is very likely the X-ray excess that has been observed previously in BATSE data alone continues into the X-ray band observed by the WFC. We have also made progress in joint fitting of BATSE Large Area Detector and Spectroscopy Detector data with that of the Total Absorption Scintillation Calorimeter (TASC) of the EGRET experiment on CGRO. The TASC data are important to understanding the high-energy response of the BATSE data. We have produced time-sequences of spectra for two important GRB with data from both instruments. The Summer workshop on GRBs at the Aspen Center for Physics provided an opportunity for in-depth discussion of our on-going work. To aid our effort, we continue to make improvements in our spectral analysis software, RMFIT (rewritten from WINGSPAN).

Briggs, Michael S.↗

Time resolved simulation of lightning by LIP

Results of time-resolved spectra of lightning simulation in air by laser-induced plasma (LIP) are reported. The measured electron temperatures varied from 17,000 +/-1000 K at 600 ns to 12,000 +/-1000 K at 4 microsec after the ignition of the plasma. Electron densities in the plasma varied from (7.0 +/-1.4) x 10 exp 17/cu cm to (9.0 +/-1.8) x 10 exp 16/cu cm for the above times. A comparison of state variables for LIP and natural lightning is presented. Immediately following the ignition, both natural lightning and LIP are found to reach temperatures in excess of 16,000 K and relax to ambient pressure with different rates. They are expected to approach the 2000-4000-K temperature range, which is important to chemical synthesis, in an asymptotically similar fashion.

Jebens, D. S.↗

Heat-flux measurements for the rotor of a full-stage turbine. II - Description of analysis technique and typical time-resolved measurements

An analytical technique for obtaining the time-resolved heat flux of a turbine blade is applied to the case of a TFE 731-2 hp full-stage rotating turbine. In order to obtain the heat flux values from the thin film gage temperature histories, a finite difference procedure is used to solve the heat equation with variable thermal properties. After setting out the data acquisition and analysis procedures, their application is illustrated for three midspan locations on the blade and operation at the design flow function. Results demonstrate that the magnitude of the heat flux fluctuation due to vane-balde interaction is large by comparison to the time-averaged heat flux at all investigated locations; FFT of a portion of the heat flux record illustrates that the dominant frequencies occur at the wake-cutting frequency and its harmonics.

Dunn, M. G.↗

Time resolved surface photovoltage measurements using a big data capture approach to KPFM

Optoelectronic behavior in materials such as organic/inorganic hybrid perovskites depend on a complex interplay between fast (electronic) and slower (ionic) processes. These processes are thought to be influenced by structural inhomogeneities (e.g. interfaces and grain boundaries) bringing forward the necessity for development of techniques capable of correlating nanostructure and photo-transport behavior. While Kelvin probe force microscopy (KPFM) is ideally suited to map surface potentials on relevant length scales, it lacks sufficient temporal resolution to extract the meaningful system dynamics. Here, we develop a time resolved surface photovoltage (SPV) measurement based on full information capture of the photodetector stream during open loop KPFM operation. G-Mode, or G-KPFM allows quantification of SPV with microsecond temporal and nanoscale spatial resolution. Using this technique, we observe concurrent spatial and fast temporal variations in the SPV generated across a methylammonium lead bromide (MAPbBr3) thin film, a possible indicator relating microstructure with heterogenous photo-transport behavior. Here, we further demonstrate the advantage of adopting big data analytics including unsupervised clustering methods to quickly discern spatial variability in the information rich SPV dataset. Beyond G-KPFM, such clustering methods will be useful for interpretation of the multidimensional datasets arising from the growing number of time resolved KPFM approaches now available.

36 MATERIALS SCIENCE↗

Chopper system for time resolved experiments with synchrotron radiation

A chopper system for time resolved pump-probe experiments with x-ray beams from a synchrotron is described. The system has three parts: a water-cooled heatload chopper, a high-speed chopper, and a millisecond shutter. The chopper system, which is installed in beamline ID09B at the European Synchrotron Radiation Facility, provides short x-ray pulses for pump-probe experiments with ultrafast lasers. The chopper system can produce x-ray pulses as short as 200 ns in a continuous beam and repeat at frequencies from 0 to 3 kHz. For bunch filling patterns of the synchrotron with pulse separations greater than 100 ns, the high-speed chopper can isolate single 100 ps x-ray pulses that are used for the highest time resolution. A new rotor in the high-speed chopper is presented with a single pulse (100 ps) and long pulse (10 {mu}s) option. In white beam experiments, the heatload of the (noncooled) high-speed chopper is lowered by a heatload chopper, which absorbs 95% of the incoming power without affecting the pulses selected by the high speed chopper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cs-Exchange in Birnessite: Raction Mechanisms Inferred from Time-Resolved X-ray Diffraction and Transmission Electron Microscopy

We have explored the exchange of Cs for interlayer Na in birnessite using several techniques, including transmission electron microscopy (TEM) and time-resolved synchrotron X-ray diffraction (XRD). Our goal was to test which of two possible exchange mechanisms is operative during the reaction: (1) diffusion of cations in and out of the interlayer or (2) dissolution of Na-birnessite and reprecipitation of Cs-birnessite. The appearance of distinct XRD peaks for Na- and Cs-rich phases in partially exchanged samples offered support for a simple diffusion model, but it was inconsistent with the compositional and crystallographic homogeneity of (Na,Cs)-birnessite platelets from core to rim as ascertained by TEM. Time-resolved XRD revealed systematic changes in the structure of the emergent Cs-rich birnessite phase during exchange, in conflict with a dissolution and reprecipitation model. Instead, we propose that exchange occurred by sequential delamination of Mn oxide octahedral sheets. Exfoliation of a given interlayer region allowed for wholesale replacement of Na by Cs and was rapidly followed by reassembly. This model accounts for the rapidity of metal exchange in birnessite, the co-existence of distinct Na- and Cs-birnessite phases during the process of exchange, and the uniformly mixed Na- and Cs-compositions ascertained from point analyses by selected area electron diffraction and energy dispersive spectroscopy of partially exchanged grains.

36 MATERIALS SCIENCE↗

Probing the hydrogen-bond network of water via time-resolved soft x-ray spectroscopy

We report time-resolved studies of hydrogen bonding in liquid H2O, in response to direct excitation of the O-H stretch mode at 3 mu m, probed via soft x-ray absorption spectroscopy at the oxygen K-edge. This approach employs a newly developed nanofluidic cell for transient soft x-ray spectroscopy in liquid phase. Distinct changes in the near-edge spectral region (XANES) are observed, and are indicative of a transient temperature rise of 10K following transient laser excitation and rapid thermalization of vibrational energy. The rapid heating occurs at constant volume and the associated increase in internal pressure, estimated to be 8MPa, is manifest by distinct spectral changes that differ from those induced by temperature alone. We conclude that the near-edge spectral shape of the oxygen K-edge is a sensitive probe of internal pressure, opening new possibilities for testing the validity of water models and providing new insight into the nature of hydrogen bonding in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗