Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Advances in explosives analysis—part I. animal, chemical, ion, and mechanical methods

The number and capability of explosives detection and analysis methods have increased substantially since the publication of the Analytical and Bioanalytical Chemistry special issue devoted to Explosives Analysis (Moore and Goodpaster, Anal Bioanal Chem 395(2):245–246, 2009). We review and critically evaluate the latest (the past five years) important advances in explosives detection, with details of the improvements over previous methods, and suggest possible avenues towards further advances in, e.g., stand-off distance, detection limit, selectivity, and penetration through camouflage or packaging. The review consists of two parts. Moreover, Part I, reviews methods based on animals, chemicals (including colorimetry, molecularly imprinted polymers, electrochemistry, and immunochemistry), ions (both ion-mobility spectrometry and mass spectrometry), and mechanical devices. Part II will review methods based on photons, from very energetic photons including X-rays and gamma rays down to the terahertz range, and neutrons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for direct, semi-quantitative analysis of gas phase samples using gas chromatography-inductively coupled plasma-mass spectrometry

A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GC sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3 . This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-element isotopic analysis of hot particles from Chornobyl

Microscopic fuel fragments, so-called “hot particles”, were released during the 1986 accident at the Chornobyl nuclear powerplant and continue to contaminate the exclusion zone in northern Ukraine. Isotopic analysis can provide vital information about sample origin, history and contamination of the environment, though it has been underutilized due to the destructive nature of most mass spectrometric techniques, and inability to remove isobaric interference. Recent developments have diversified the range of elements that can be investigated through resonance ionization mass spectrometry (RIMS), notably in the fission products. The purpose of this study is to demonstrate the application of multi-element analysis on hot particles as relates to their burnup, particle formation in the accident, and weathering. The particles were analysed with two RIMS instruments: resonant-laser secondary neutral mass spectrometry (rL-SNMS) at the Institute for Radiation Protection and Radioecology (IRS) in Hannover, Germany, and laser ionization of neutrals (LION) at Lawrence Livermore National Laboratory (LLNL) in Livermore, USA. Comparable results across instruments show a range of burnup dependent isotope ratios for U and Pu and Cs, characteristic of RBMK-type reactors. Results for Rb, Ba and Sr show the influence of the environment, retention of Cs in the particles and time passed since fuel discharge.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Membrane-Extraction Ion Mobility Spectrometry for In-Situ Detection of Chlorinated Hydrocarbons in Water

Membrane-extraction ion mobility spectrometry (ME-IMS) has been developed for in-situ sampling and analysis of trace chlorinated hydrocarbons in water in a single procedure. The sampling is configured so that aqueous contaminants permeate through a spiral hollow polydimethylsiloxane (PDMS) membrane and are carried away by a vapor flow through the membrane tube. The extracted analyte flows into an atmospheric pressure chemical ionization (APCI) chamber and is analyzed in a home-made IMS analyzer. PDMS membrane is found to effectively extract chlorinated hydrocarbon solvents from liquid phase to vapor. The specialized IMS analyzer has been found to have resolutions of R=33 and 41, respectively, for negative- and positive-modes and is capable of detecting aqueous tetrachloroethylene (PCE) and trichloroethylene (TCE) as low as 80 g/L and 74 g/L in negative ion mode, respectively. The time-dependent characteristics of sampling and detection of TCE are both experimentally and theoretically studied for various concentrations, membrane lengths, and flow rates. These characteristics demonstrate that membrane-extraction IMS is feasible for the continuous monitoring of chlorinated hydrocarbons in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

Data Trend Shifts Induced by Method of Concentration for Trace Metals in Seawater: Automated Online Preconcentration vs Borohydride Reductive Coprecipitation of Nearshore Seawater Samples for Analysis of Ni, Cu, Zn, Cd, and Pb via ICP-MS

This research compares performance, reproducibility, and detection limits of ambient seawater analysis for trace metals using both borohydride reductive co-precipitation and an automated chelation column (seaFAST™ 2) co-preconcentration for matrix interferent elimination on total and dissolved grab samples in nearshore to marine waters, over a broad concentration range, prior to ICP-MS injection. A move to an online preconcentration method both minimizes sample preparation, and eliminates correction errors when accounting for trace impurities in precipitated samples, induced via reagents. The reproducability of the online preconcentration method described, coupled with low blanks and method detection limits (MDLs), demonstrates an effective move to an automated procedure using ethylenediaminetriacetic and iminodiacetate acid chelation exchange resin and multi-analyte determination via ICP-MS for total and dissolved Ni, Cu, Zn, Cd, and Pb in marine water samples. Average CASS-5 recoveries using the online preconcentration method (n=9) were 109±7%, 104±5%, 103±7%, 101±3%, and 86±8% respectively. The MDLs obtained from the automated method for Ni, Cu, Zn, Cd and Pb were 3.3, 1.8, 13.5, 4, and 10 times lower, respectively, than for the Borohydride method. There were statistically significant differences between the methods for CASS-5 recoveries of Ni, Cu, Zn (p < 0.0001), and Pb (p = 0.0024). Comparison of methods gave high concordance (rC = 0.90) between methods for total and dissolved Ni, Cu, Zn, and Pb, and total Cd.

seaFAST, borohydride, seawater, Ethylenediaminetet↗

Investigations into the origins of polyatomic ions in inductively coupled plasma-mass spectrometry

An inductively coupled plasma-mass spectrometer (ICP-MS) is an elemental analytical instrument capable of determining nearly all elements in the periodic table at limits of detection in the parts per quadrillion and with a linear analytical range over 8-10 orders of magnitude. Three concentric quartz tubes make up the plasma torch. Argon gas is spiraled through the outer tube and generates the plasma powered by a looped load coil operating at 27.1 or 40.6 MHz. The argon flow of the middle channel is used to keep the plasma above the innermost tube through which solid or aqueous sample is carried in a third argon stream. A sample is progressively desolvated, atomized and ionized. The torch is operated at atmospheric pressure. To reach the reduced pressures of mass spectrometers, ions are extracted through a series of two, approximately one millimeter wide, circular apertures set in water cooled metal cones. The space between the cones is evacuated to approximately one torr. The space behind the second cone is pumped down to, or near to, the pressure needed for the mass spectrometer (MS). The first cone, called the sampler, is placed directly in the plasma plume and its position is adjusted to the point where atomic ions are most abundant. The hot plasma gas expands through the sampler orifice and in this expansion is placed the second cone, called the skimmer. After the skimmer traditional MS designs are employed, i.e. quadrupoles, magnetic sectors, time-of-flight. ICP-MS is the leading trace element analysis technique. One of its weaknesses are polyatomic ions. This dissertation has added to the fundamental understanding of some of these polyatomic ions, their origins and behavior. Although mainly continuing the work of others, certain novel approaches have been introduced here. Chapter 2 includes the first reported efforts to include high temperature corrections to the partition functions of the polyatomic ions in ICP-MS. This and other objections to preceeding papers in this area were addressed. Errors in the measured T gas values were found for given errors in the experimental and spectroscopic values. The ionization energy of the neutral polyatomic ion was included in calculations to prove the validity of ignoring more complicated equilibria. Work was begun on the question of agreement between kinetics of the plasma and interface and the increase and depletion seen in certain polyatomic ions. This dissertation was also the first to report day to day ranges for T gas values and to use a statistical test to compare different operating conditions. This will help guide comparisons of previous and future work. Chapter 4 was the first attempt to include the excited electronic state 2 in the partition function of ArO + as well as the first to address the different dissociation products of the ground and first electronic levels of ArO + . Chapter 5 reports an interesting source of memory in ICP-MS that could affect mathematical corrections for polyatomic ions. For future work on these topics I suggest the following experiments and investigations. Clearly not an extensive list, they are instead the first topics curiosity brings to mind. (1) Measurement of T gas values when using the flow injection technique of Appendix B. It was believed that there was a fundamental difference in the plasma when the auto-sampler was used versus a continuous injection. Is this reflected in T gas values? (2) The work of Chapter 3 can be expanded and supplemented with more trials, new cone materials (i.e. copper, stainless steel) and more cone geometries. Some of this equipment is already present in the laboratory, others could be purchased or made. (3) T gas values from Chapter 3 could be correlated with instrument pressures during the experiment. Pressures after the skimmer cone were recorded for many days but have yet to be collated with the measured T gas values. (4) The work in Chapter 5 could be expanded to include more metals. Does the curious correlation between measured T gas and element boiling point persist? (5) Investigate non-linear correlations to T gas values of the MO + memory in Chapter 5. Temperatures along the skimmer walls are not a linear gradient. Ring deposits have been observed on the cone and photographs of the interface show light intensities shaping a sort of tailing peak along the outside skimmer wall. Is there a physical property of the metals or metal oxides that would give this peak with the T gas values? (6) Chemical state speciation of the metal deposits on the skimmers of Chapter 5. There may be a more logical correlation between Tgas and a physical property of the deposit-ing chemical if all the metals do not deposit in the same form. (7) A collaboration with our computational collegues would be most welcome. Newer calculations for ArO + and RuO + would be very helpful.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additive manufacturing of platinum group element (PGE) reference materials with a silica matrix

The microanalytical community has an outstanding need for platinum group element (PGE) reference materials, particularly for trace element analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). National Institute of Standards and Technology (NIST) glasses contain Rh, Pd, and Pt, but lack Ru, Os, and Ir. Synthesis of silicate PGE standards has proven difficult due the tendency of PGEs to form metallic nuggets. Additive manufacturing methods were used to produce PGE standards with a silica matrix. Monodispersed submicron PGE-doped Stöber particles were used as feedstock materials for electrophoretic deposition (EPD). Two-cm-sized samples produced by EPD were subsequently densified by thermal processing. The homogeneity of PGEs was tested using LA-ICPMS and concentrations were measured by laser ablation and solution ICPMS. The PGE concentrations ranged from 0.5 to 3 μg/g. The inhomogeneity was at the 3% RSD level for Ru, Rh, Ir, and Os throughout and 5% for Pt and Pd in the interior of the samples. Based on LA-ICPMS analyses, the interiors of the two samples have near identical concentrations in PGEs. The samples fabricated in this study represent the most complete and homogeneous PGE standards produced with a silicate matrix. The ability to produce multiple samples with the same composition provides opportunities for validating methods, monitoring long-term reproducibility, and facilitating interlaboratory comparisons.

36 MATERIALS SCIENCE↗

Exploratory Visual Analysis of Anomalous Runtime Behavior in Streaming High Performance Computing Applications

Online analysis of runtime behavior is essential for performance tuning in streaming scientific workflows. Integration of anomaly detection and visualization is necessary to support human-centered analysis, such as verification of candidate anomalies utilizing domain knowledge. In this work, we propose an efficient and scalable visual analytics system for online performance analysis of scientific workflows toward the exascale scenario. Here, our approach uses a call stack tree representation to encode the structural and temporal information of the function executions. Based on the call stack tree features (e.g., execution time of the root function or vector representation of the tree structure), we employ online anomaly detection approaches to identify candidate anomalous function executions. We also present a set of visualization tools for verification and exploration in a level-of-detailed manner. General information, such as distribution of execution times, are provided in an overview visualization. The detailed structure (e.g., function invocation relations) and the temporal information (e.g., message communication) of the execution call stack of interest are also visualized. The usability and efficiency of our methods are verified in a real-world HPC application.

97 MATHEMATICS AND COMPUTING↗

High-gradient magnetic filtration of UO 2 colloids from aqueous suspensions

Environmental samples often contain innocuous components that make trace actinide analysis difficult and expensive. Therefore, it is expedient to separate these materials from actinide particles. One characteristic of many actinides is that they are paramagnetic. High-gradient magnetic filtration (HGMF) is a non-destructive technique that selectively captures magnetic constituents from a matrix containing non-magnetic species. Here, in this work, a novel HGMF device made of a permanent magnet array was used to effectively separate UO 2 particles from undesirable soil species. Up to 88% of the UO 2 particles present in suspensions were effectively captured by HGMF, resulting in their enrichment and a substantial reduction in the concentrations of other constituents.

Actinide separations↗

Significance of otolith calcium carbonate crystal structure diversity to microchemistry studies

Otoliths, calcium carbonate (CaCO 3 ) ear stones of fish, contain a wealth of information about fish life and environmental history yet the CaCO 3 polymorph form the otolith is made of is a critical, but seldom considered, piece of information during otolith analysis. Otolith trace element chemistry data increasingly informs management decisions, but recent work has shown that CaCO 3 polymorphs—aragonite, vaterite, and calcite—can bear on incorporation of trace elements in a non-trivial way. Most fishes are thought to have otoliths of the aragonite CaCO 3 form, but this construct is potentially outdated with many recent literature reports showing otherwise. Our study used previously unpublished neutron diffraction data and reports from published literature to address three objectives: (1) summarize the relative effects of otolith CaCO 3 polymorphism on otolith microchemistry, (2) summarize reports of otolith polymorphs to gain a better understanding of the extent of non-aragonite otoliths among fishes, (3) outline future research needed to align interpretations of microchemistry with our current understanding of otolith polymorph diversity. We found that while aragonite otoliths are the most common, so are exceptions. To illustrate, the ostensibly rare (among species) CaCO 3 form vaterite was reported in at least some otoliths of 40% of the species surveyed. Our work suggests that examination of the CaCO 3 polymorph composition of otoliths should become more common particularly in studies where results will or may be used to inform management decisions. Future research should work to attribute controls on otolith CaCO 3 polymorph expression using a combination of -omics and material characterization methods to enrich the life history and environmental information output from otoliths and increase our understanding of the assumptions made in otolith trace element chemistry studies.

58 GEOSCIENCES↗

Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters

Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, the ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.

Environmental Molecular Sciences Laboratory↗

Interrogating Proton Affinities of Organophosphonate Species Via Atmospheric Flow Tube Mass Spectrometry and Computational Methods

Within trace vapor analysis in environmental monitoring, defense, and industry, atmospheric flow tube mass spectrometry (AFT-MS) can fill a role that incorporates non-contact vapor analysis with the selectivity and low detection limits of mass spectrometry. AFT-MS has been applied to quantitating certain explosives by selective clustering with nitrate and more recently applied to detecting tributyl phosphate and dimethyl methylphosphonate as protonated species. Developing AFT-MS methods for organophosphorus species is appealing, given that this class of compounds includes a range of pollutants, chemical warfare agent (CWA) simulants, and CWA degradation products. A key aspect of targeting organophosphorus analytes has included the use of dopant ion chemistry to form adducts that impart additional analytical selectivity. The assessment of potential dopant molecules suited to enhance detection of these compounds is hindered by few published ion thermochemical properties for organophosphorus species, such as proton affinity, which can be used for approximating proton-bound dimer bond strength. As a preliminary investigation for the progression of sensing methods involving AFT-MS, we have applied both the extended kinetic method and computational approaches to eight organophosphorus CWA simulants to determine their respective gas-phase proton affinities. Notable observed trends, supported by computational efforts, include an increase in proton affinity as the alkyl chain lengths on the phosphonates increased. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Slip transmission of high angle grain boundaries in body-centered cubic metals: Micropillar compression of pure Ta single and bi-crystals

In this study, we seek to probe and understand the mechanical behavior of grain boundaries in pure Ta as a model bcc material using micropillar compression experiments. Three high angle grain boundaries are chosen with varying crystal orientations. Multiple bi-crystal pillars are prepared containing a single, nearly vertical grain boundary in the approximate center of the pillar and compared against their single crystalline pillar counterparts. The main phenomenon of interest was slip transmission or strain transfer in the bi-crystals which was considered to occur when slip traces aligned across the grain boundary. This occurred in two of the three bi-crystals.

36 MATERIALS SCIENCE↗

Krypton-81 dating of the deep Continental Intercalaire aquifer with implications for chlorine-36 dating

Deep groundwater samples from the Continental Intercalaire (CI) aquifer in the Northern Tunisian Sahara have been analyzed for noble gases 3 He, 4 He, Ne and 81 Kr, and for 14 C to better constrain the groundwater residence time of this large transboundary aquifer. Its significant radiogenic 4 He content and background-level 14 C both indicate water older than a few tens of thousands of years. Distinct helium concentrations and Ne/He ratios suggest different groundwater flow paths through the Tozeur and Kebili regions. 81 Kr is applied for the first time on the CI aquifer, providing more direct evidence for the presence of old groundwater with 81 Kr/Kr ratios at 63% – 15% of the atmospheric value, corresponding to residence times of 150 – 630 ka. These newly obtained 81 Kr ages enable a re-evaluation of the previously reported data from the Tozeur region in order to better constrain the input values of 36 Cl/Cl and Cl. The initial 36 Cl/Cl ratio is found to be 4 – 6 times larger than previously assumed, and the initial Cl concentration 6 – 15 times smaller. The results of 81 Kr dating and the recalibrated 36 Cl dating define an eastward age progression across > 500 km of flow path from the Algerian to Tunisian sections. Here, this study exemplifies the utility of 81 Kr not only as an independent and conservative chronometer, but also as a supplemental measurement to better calibrate the parameters required for other age tracers, including cosmogenic 36 Cl and radiogenic 4 He.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High efficiency resonance ionization of thorium

Here, multi-step resonance ionization spectroscopy of thorium has been performed with Ti:Sapphire lasers and a hot-cavity laser ion source. Resonance ionization schemes involving three-color, three-photon ionization processes are evaluated and a new three-photon scheme is demonstrated with measured overall ionization efficiency of 38.6(5)%. This high efficiency makes it possible to determine the thorium impurities in materials used for ultra-low background neutrino detectors and could also benefit ultra-trace thorium analysis using resonance ionization mass spectrometry for various radiochemical tracer applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Thermal Model Prediction Through Statistical Analysis of Irradiation and Post-Irradiation Data from AGR Experiments

As part of the High Temperature Reactors (HTR) R&D program, a series of irradiation tests, designated as Advanced Gas-cooled Reactor (AGR), have been defined to support development and qualification of fuel design, fabrication process, and fuel performance under normal operation and accident conditions. The AGR tests employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule and instrumented with thermocouples (TC) embedded in graphite blocks enabling temperature control. While not possible to obtain by direct measurements in the tests, crucial fuel conditions (e.g., temperature, neutron fast fluence, and burnup) are calculated using core physics and thermal modeling codes. This paper is focused on AGR test fuel temperature predicted by the ABAQUS code's finite element-based thermal models. The work follows up on a previous study, in which several statistical analysis methods were adapted, implemented in the NGNP Data Management and Analysis System (NDMAS), and applied for qualification of AGR-1 thermocouple data. Abnormal trends in measured data revealed by the statistical analysis are traced to either measuring instrument deterioration or physical mechanisms in capsules that may have shifted the system thermal response. The main thrust of this work is to exploit the variety of data obtained in irradiation and post-irradiation examination (PIE) for assessment of modeling assumptions. As an example, the uneven reduction of the control gas gap in Capsule 5 found in the capsule metrology measurements in PIE helps identify mechanisms other than TC drift causing the decrease in TC readings. This suggests a more physics-based modification of the thermal model that leads to a better fit with experimental data, thus reducing model uncertainty and increasing confidence in the calculated fuel temperatures of the AGR-1 test.

99 GENERAL AND MISCELLANEOUS↗