Search NASA⌕ Search

SEARCH · Search NASA

Results for “triangulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A structural framework for anomalous change detection and characterization

We present a spatially adaptive scheme for automatically searching a pair of images of a scene for unusual and interesting changes. Our motivation is to bring into play structural aspects of image features alongside the spectral attributes used for anomalous change detection (ACD). We leverage a small but informative subset of pixels, namely edge pixels of the images, as anchor points of a Delaunay triangulation to jointly decompose the images into a set of triangular regions, called trixels, which are spectrally uniform. Such decomposition helps in image regularization by simple-function approximation on a feature-adaptive grid. Applying ACD to this trixel grid instead of pixels offers several advantages. It allows: (1) edge-preserving smoothing of images, (2) speed-up of spatial computations by significantly reducing the representation of the images, and (3) the easy recovery of structure of the detected anomalous changes by associating anomalous trixels with polygonal image features. The latter facility further enables the application of shape-theoretic criteria and algorithms to characterize the changes and recognize them as interesting or not. This incorporation of spatial information has the potential to filter out some spurious changes, such as due to parallax, shadows, and misregistration, by identifying and filtering out those that are structurally similar and spatially pervasive. Our framework supports the joint spatial and spectral analysis of images, potentially enabling the design of more robust ACD algorithms.

99 GENERAL AND MISCELLANEOUS↗

Automated contour mapping using sparse volume sampling for 4D radiation therapy

The purpose of this work is to develop a novel strategy to automatically map organ contours from one phase of respiration to all other phases on a four-dimensional computed tomography (4D CT). A region of interest (ROI) was manually delineated by a physician on one phase specific image set of a 4D CT. A number of cubic control volumes of the size of {approx}1 cm were automatically placed along the contours. The control volumes were then collectively mapped to the next phase using a rigid transformation. To accommodate organ deformation, a model-based adaptation of the control volume positions was followed after the rigid mapping procedure. This further adjustment of control volume positions was performed by minimizing an energy function which balances the tendency for the control volumes to move to their correspondences with the desire to maintain similar image features and shape integrity of the contour. The mapped ROI surface was then constructed based on the central positions of the control volumes using a triangulated surface construction technique. The proposed technique was assessed using a digital phantom and 4D CT images of three lung patients. Our digital phantom study data indicated that a spatial accuracy better than 2.5 mm is achievable using the proposed technique. The patient study showed a similar level of accuracy. In addition, the computational speed of our algorithm was significantly improved as compared with a conventional deformable registration-based contour mapping technique. The robustness and accuracy of this approach make it a valuable tool for the efficient use of the available spatial-tempo information for 4D simulation and treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BrachyView: Proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy

Purpose: The conformity of the achieved dose distribution to the treatment plan strongly correlates with the accuracy of seed implantation in a prostate brachytherapy treatment procedure. Incorrect seed placement leads to both short and long term complications, including urethral and rectal toxicity. The authors present BrachyView, a novel concept of a fast intraoperative treatment planning system, to provide real-time seed placement information based on in-body gamma camera data. BrachyView combines the high spatial resolution of a pixellated silicon detector (Medipix2) with the volumetric information acquired by a transrectal ultrasound (TRUS). The two systems will be embedded in the same probe so as to provide anatomically correct seed positions for intraoperative planning and postimplant dosimetry. Dosimetric calculations are based on the TG-43 method using the real position of the seeds. The purpose of this paper is to demonstrate the feasibility of BrachyView using the Medipix2 pixel detector and a pinhole collimator to reconstruct the real-time 3D position of low dose-rate brachytherapy seeds in a phantom. Methods: BrachyView incorporates three Medipix2 detectors coupled to a multipinhole collimator. Three-dimensionally triangulated seed positions from multiple planar images are used to determine the seed placement in a PMMA prostate phantom in real time. MATLAB codes were used to test the reconstruction method and to optimize the device geometry. Results: The results presented in this paper show a 3D position reconstruction accuracy of the seed in the range of 0.5-3 mm for a 10-60 mm seed-to-detector distance interval (Z direction), respectively. The BrachyView system also demonstrates a spatial resolution of 0.25 mm in the XY plane for sources at 10 mm distance from Medipix2 detector plane, comparable to the theoretical value calculated for an equivalent gamma camera arrangement. The authors successfully demonstrated the capability of BrachyView for real-time imaging (using a 3 s data acquisition time) of different brachytherapy seed configurations (with an activity of 0.05 U) throughout a 60 Multiplication-Sign 60 Multiplication-Sign 60 mm{sup 3} Perspex prostate phantom. Conclusions: The newly developed miniature gamma camera component of BrachyView, with its high spatial resolution and real time capability, allows accurate 3D localization of seeds in a prostate phantom. Combination of the gamma camera with TRUS in a single probe will complete the BrachyView system.

60 APPLIED LIFE SCIENCES↗

Joint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking

Purpose: The intraprocedural tracking of respiratory motion has the potential to substantially improve image-guided diagnosis and interventions. The authors have developed a sparse-to-dense registration approach that is capable of recovering the patient's external 3D body surface and estimating a 4D (3D + time) surface motion field from sparse sampling data and patient-specific prior shape knowledge.Methods: The system utilizes an emerging marker-less and laser-based active triangulation (AT) sensor that delivers sparse but highly accurate 3D measurements in real-time. These sparse position measurements are registered with a dense reference surface extracted from planning data. Thereby a dense displacement field is recovered, which describes the spatio-temporal 4D deformation of the complete patient body surface, depending on the type and state of respiration. It yields both a reconstruction of the instantaneous patient shape and a high-dimensional respiratory surrogate for respiratory motion tracking. The method is validated on a 4D CT respiration phantom and evaluated on both real data from an AT prototype and synthetic data sampled from dense surface scans acquired with a structured-light scanner.Results: In the experiments, the authors estimated surface motion fields with the proposed algorithm on 256 datasets from 16 subjects and in different respiration states, achieving a mean surface reconstruction accuracy of ±0.23 mm with respect to ground truth data—down from a mean initial surface mismatch of 5.66 mm. The 95th percentile of the local residual mesh-to-mesh distance after registration did not exceed 1.17 mm for any subject. On average, the total runtime of our proof of concept CPU implementation is 2.3 s per frame, outperforming related work substantially.Conclusions: In external beam radiation therapy, the approach holds potential for patient monitoring during treatment using the reconstructed surface, and for motion-compensated dose delivery using the estimated 4D surface motion field in combination with external-internal correlation models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-BRE-01: A 3D Solver of Linear Boltzmann Transport Equation Based On a New Angular Discretization Method with Positivity for Photon Dose Calculation Benchmarked with Geant4

Purpose: The Linear Boltzmann Transport Equation (LBTE) solved through statistical Monte Carlo (MC) method provides the accurate dose calculation in radiotherapy. This work is to investigate the alternative way for accurately solving LBTE using deterministic numerical method due to its possible advantage in computational speed from MC. Methods: Instead of using traditional spherical harmonics to approximate angular scattering kernel, our deterministic numerical method directly computes angular scattering weights, based on a new angular discretization method that utilizes linear finite element method on the local triangulation of unit angular sphere. As a Result, our angular discretization method has the unique advantage in positivity, i.e., to maintain all scattering weights nonnegative all the time, which is physically correct. Moreover, our method is local in angular space, and therefore handles the anisotropic scattering well, such as the forward-peaking scattering. To be compatible with image-guided radiotherapy, the spatial variables are discretized on the structured grid with the standard diamond scheme. After discretization, the improved sourceiteration method is utilized for solving the linear system without saving the linear system to memory. The accuracy of our 3D solver is validated using analytic solutions and benchmarked with Geant4, a popular MC solver. Results: The differences between Geant4 solutions and our solutions were less than 1.5% for various testing cases that mimic the practical cases. More details are available in the supporting document. Conclusion: We have developed a 3D LBTE solver based on a new angular discretization method that guarantees the positivity of scattering weights for physical correctness, and it has been benchmarked with Geant4 for photon dose calculation.

97 MATHEMATICS AND COMPUTING↗

The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real-time image guidance method

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time image guidance method that uses widely available radiotherapy technology, i.e., a gantry-mounted x-ray imager. The authors report on the geometric and dosimetric results of the first patient treatment using KIM which occurred on September 16, 2014. Methods: KIM uses current and prior 2D x-ray images to estimate the 3D target position during cancer radiotherapy treatment delivery. KIM software was written to process kilovoltage (kV) images streamed from a standard C-arm linear accelerator with a gantry-mounted kV x-ray imaging system. A 120° pretreatment kV imaging arc was acquired to build the patient-specific 2D to 3D motion correlation. The kV imager was activated during the megavoltage (MV) treatment, a dual arc VMAT prostate treatment, to estimate the 3D prostate position in real-time. All necessary ethics, legal, and regulatory requirements were met for this clinical study. The quality assurance processes were completed and peer reviewed. Results: During treatment, a prostate position offset of nearly 3 mm in the posterior direction was observed with KIM. This position offset did not trigger a gating event. After the treatment, the prostate motion was independently measured using kV/MV triangulation, resulting in a mean difference of less than 0.6 mm and standard deviation of less than 0.6 mm in each direction. The accuracy of the marker segmentation was visually assessed during and after treatment and found to be performing well. During treatment, there were no interruptions due to performance of the KIM software. Conclusions: For the first time, KIM has been used for real-time image guidance during cancer radiotherapy. The measured accuracy and precision were both submillimeter for the first treatment fraction. This clinical translational research milestone paves the way for the broad implementation of real-time image guidance to facilitate the detection and correction of geometric and dosimetric errors, and resultant improved clinical outcomes, in cancer radiotherapy.

60 APPLIED LIFE SCIENCES↗

Markerless tracking of small lung tumors for stereotactic radiotherapy

Purpose: (1) To validate retrospective markerless tracking software for small lung tumors by comparing tracked motion in 4-dimensional planning computed tomography (4DCT) derived kV projection images and known tumor motion in the same 4DCT. (2) To evaluate variability of tumor motion using kV projection images from cone-beam computed tomography (CBCT) scans acquired on different days. Methods: Nonclinical tumor tracking software (TTS) used a normalized cross correlation algorithm to track the tumor on enhanced kV projection images (e.g., from a CBCT scan). The reference dataset consisted of digitally reconstructed radiographs (DRRs) from one phase of a planning 4DCT. TTS matches two in-plane coordinates and obtains the out-of-plane coordinate by triangulating with match results from other projections. (1) To validate TTS, tracking results were compared with known 4DCT tumor motion for two patients (A and B). Projection images (1 image/1°) were digitally reconstructed for each 4DCT phase. From these, kV projection series were composed simulating full breathing cycles every 20° of gantry rotation [breathing period = 20°/(6°/s) = 3.33 s]. Reference templates were 360 “tumor enhanced” DRRs from the 4DCT expiration phase. TTS-derived tumor motion was compared to known tumor motion on 4DCT. (2) For five patients, TTS-assessed motion during clinical CBCT acquisition was compared with motion on the planning 4DCT, and the motion component in the Y (cranio–caudal)-direction was compared with the motion of an external marker box (RPM, real-time position management). Results: (1) Validation results: TTS for case A (tumor 6.2 cm{sup 3}, 32 mm axial diameter) over 360° showed mean motion X (medial–lateral) = 3.4, Y = 11.5, and Z (ventral–dorsal) = 4.9 mm (1 SD < 1.0 mm). Corresponding 4DCT motion was X = 3.1, Y = 11.3, and Z = 5.1 mm. Correlation coefficients between TTS tumor motion and displacement of the tumor’s center of mass (CoM) on 4DCT were 0.64, 0.96, and 0.82 (X, Y, and Z, respectively). For case B (4.1 cm{sup 3}, 20 mm diameter), due to temporarily decreased tumor visibility preventing TTS from resolving the tumor, robust tracking data were only available between angles 300°–40° and 120°–220°. Mean motion according to TTS was X = 2.0, Y = 7.7, and Z = 8.2 mm (1 SD < 0.9 mm). Tumor motion on 4DCT was X = 1.8, Y = 7.6, and Z = 9.5 mm and correlation coefficients between TTS motion and CoM displacement were 0.59, 0.95, and 0.93 (X, Y, and Z, respectively). (2) Clinical results: TTS revealed a mean intrafraction variation in tumor motion in Y-direction of >2.0 mm (1 SD) in four of five patients. In addition, clinical tumor motion amplitude differed from that seen on planning 4DCT. Internal and external structures that create abrupt density change (e.g., table-top edge, interface between lung/mediastinum and lung/heart) were observed to prevent 360° tracking of the tumor. Correlation coefficients between TTS motion in the Y-direction and the RPM signal (22 observations) ranged from 0.78 to 0.96. In 2D, 241 TTS matches at end-inspiration and end-expiration were visually validated: mean difference was 0.8 mm (SD = 0.7) for both. Conclusions: TTS can track small lung tumors if these are visible in kV projections. A 4DCT dataset can be used to validate kV tracking of moving targets. TTS and 4DCT displacement agreed to within 2 mm. TTS and RPM motion were closely associated but tumor motion during CBCT can vary from the planning 4DCT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-224: Considerations for the Proper Treatment of Multiple Cranial Metastases with Single Isocenter Volumetric Modulated Arc Therapy

Purpose: To investigate some limitations of single isocenter VMAT for cranial multiple met cases. Methods: A single isocenter VMAT plan (Varian, Eclipse AAA10 commissioned down to 1 cm) was designed for two 7mm diameter spherical targets in a rectangular Solid Water (Gammex) phantom. The targets were separated by a distance of 6cm and the isocenter was centered in one of the targets. The plan was delivered (Varian, Truebeam STx) three separate times with different artificial couch angle errors of 0, 0.5 and 1 degree. The coronal dose distributions were measured with calibrated EBT3 film placed at mid-phantom. EBT3 film dosimetry was also performed on the delivery of separate multiple arc vmat plans to targets below 6mm in diameter. Results: Measurements of the sup/inf dose profiles through the high dose distributions show no movement of the central axis high dose region and shifts of the high dose region intended for the off-axis target. For the 1 degree rotation error, the high dose region was shifted 1.04mm from the target. This corresponds to the shift expected from triangulation (60mmxTan(1deg)=1.047mm). Furthermore, a streak of 10% interleaf leakage dose was observed and is likely a Result of the off axis target traveling a wide path such that a long length of MLC is exposed for the whole arc. The calculated dose was about 10% to 15% low compared to that measured on film for a 5mm diameter target. Conclusion: Judicious use of additional margin for off axis targets or limits on the span of multiple mets treated with one isocenter is recommended. The magnitude of the margin should be based on the rotational errors evaluated for the positioning system and the distance of the target from the isocenter. A lower limit of lesion size that can be accurately treated with VMAT should be determined.

60 APPLIED LIFE SCIENCES↗

Local curvature analysis for classifying breast tumors: Preliminary analysis in dedicated breast CT

Purpose: The purpose of this study is to measure the effectiveness of local curvature measures as novel image features for classifying breast tumors. Methods: A total of 119 breast lesions from 104 noncontrast dedicated breast computed tomography images of women were used in this study. Volumetric segmentation was done using a seed-based segmentation algorithm and then a triangulated surface was extracted from the resulting segmentation. Total, mean, and Gaussian curvatures were then computed. Normalized curvatures were used as classification features. In addition, traditional image features were also extracted and a forward feature selection scheme was used to select the optimal feature set. Logistic regression was used as a classifier and leave-one-out cross-validation was utilized to evaluate the classification performances of the features. The area under the receiver operating characteristic curve (AUC, area under curve) was used as a figure of merit. Results: Among curvature measures, the normalized total curvature (C{sub T}) showed the best classification performance (AUC of 0.74), while the others showed no classification power individually. Five traditional image features (two shape, two margin, and one texture descriptors) were selected via the feature selection scheme and its resulting classifier achieved an AUC of 0.83. Among those five features, the radial gradient index (RGI), which is a margin descriptor, showed the best classification performance (AUC of 0.73). A classifier combining RGI and C{sub T} yielded an AUC of 0.81, which showed similar performance (i.e., no statistically significant difference) to the classifier with the above five traditional image features. Additional comparisons in AUC values between classifiers using different combinations of traditional image features and C{sub T} were conducted. The results showed that C{sub T} was able to replace the other four image features for the classification task. Conclusions: The normalized curvature measure contains useful information in classifying breast tumors. Using this, one can reduce the number of features in a classifier, which may result in more robust classifiers for different datasets.

60 APPLIED LIFE SCIENCES↗

SU-F-R-27: Use Local Shape Descriptor Based On Geodesic Distance to Predict Survival in Non-Small Cell Lung Cancer After Radiotherapy

Purpose: The shape of the Positron Emission Tomography (PET) image represents the heterogeneity of tumor growth in various directions, and thus could be associated with tumor malignancy. We have proposed a median geodesic distance (MGD) to represent the local complexity of the shape and use a normalized MGD (NMGD) to quantify the shape, and found a potential correlation of NMGD to survival in a 20-patient pilot study. This study was to verify the finding in a larger patient cohort. Methods: Geodesic distance of two vertices on a surface is defined as the shortest path on the surface connecting the two vertices. The MGD was calculated for each vertex on the surface to display the local complexity of the shape. The NMGD was determined as: NMGD = 100*standard deviation(MGDs)/mean(MGDs). We applied the NMGD to 40 NSCLC patients who were enrolled in prospective PET image protocols and received radiotherapy. Each patient had a pre-treatment PET scan with the resolution of 4mm*4mm*5mm. Tumors were contoured by a professional radiation oncologist and triangulation meshes were built up based on the contours. Results: The mean and standard deviation of NMGD was 6.4±3.0. The OS was 33.1±16.9 months for low NMGD group, and 15.4±15.6 months for the high NMGD group. The low NMGD group had significant better OS than the high NMGD group (p=0.0013). Conclusion: NMGD could be used as a shape biomarker to predict survival and the MGD could be combined with image texture in future to increase prediction accuracy. This study was supported by Award Number 1R01CA166948 from the NIH and National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Fractal character of the distribution of surface potential irregularities in epitaxial n-GaAs (100)

The fractal geometric properties of the relief of the surface potential of a heavily doped n{sup +}-GaAs (100) wafer are studied by Kelvin's method of atomic force microscopy. The average fractal dimensionalities determined by the triangulation method (D{sub f}), the method of horizontal cross sections (D{sub c}), and the method of similarity (D{sub s}) are rather close to each other, which is indicative of a unified nature of the fractal relief of the surface potential. In general, the fractal dimensionalities determined in the study suggest that the relative arrangement of local irregularities of the potential profile of the heavily doped n{sup +}-GaAs (100) wafer subjected to chemical and dynamic polishing is similar to the pattern corresponding to the fractal curve known as Serpinsky's napkin. It is found that the fractal irregularities of the potential vary much more gradually than it happens in the twodimensional case: the variations are proportional to linear dimensions to the power 2/D{sub c} (1 < D{sub c} < 2) rather than to the square of linear dimensions of the regions under study.

36 MATERIALS SCIENCE↗

Measuring the Error in Approximating the Sub-Level Set Topology of Sampled Scalar Data

This paper studies here the influence of the definition of neighborhoods and methods used for creating point connectivity on topological analysis of scalar functions. It is assumed that a scalar function is known only at a finite set of points with associated function values. In order to utilize topological approaches to analyze the scalar-valued point set, it is necessary to choose point neighborhoods and, usually, point connectivity to meaningfully determine critical-point behavior for the point set. Two distances are used to measure the difference in topology when different point neighborhoods and means to define connectivity are used: (i) the bottleneck distance for persistence diagrams and (ii) the distance between merge trees. Usually, these distances define how different scalar functions are with respect to their topology. These measures, when properly adapted to point sets coupled with a definition of neighborhood and connectivity, make it possible to understand how topological characteristics depend on connectivity. Noise is another aspect considered. Five types of neighborhoods and connectivity are discussed: (i) the Delaunay triangulation; (ii) the relative neighborhood graph; (iii) the Gabriel graph; (iv) the k-nearest-neighbor (KNN) neighborhood; and (v) the Vietoris–Rips complex. It is discussed in detail how topological characterizations depend on the chosen connectivity.

97 MATHEMATICS AND COMPUTING↗

Identification of Low-level Point Radioactive Sources using a sensor network

Identification of a low-level point radioactive source amidst background radiation is achieved by a network of radiation sensors using a two-step approach. Based on measurements from three or more sensors, a geometric difference triangulation method or an N-sensor localization method is used to estimate the location and strength of the source. Then a sequential probability ratio test based on current measurements and estimated parameters is employed to finally decide: (1) the presence of a source with the estimated parameters, or (2) the absence of the source, or (3) the insufficiency of measurements to make a decision. This method achieves specified levels of false alarm and missed detection probabilities, while ensuring a close-to-minimal number of measurements for reaching a decision. This method minimizes the ghost-source problem of current estimation methods, and achieves a lower false alarm rate compared with current detection methods. This method is tested and demonstrated using: (1) simulations, and (2) a test-bed that utilizes the scaling properties of point radioactive sources to emulate high intensity ones that cannot be easily and safely handled in laboratory experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochastic PArallel Rarefied-gas Time-accurate Analyzer

The SPARTA package is software for simulating low-density fluids via the Direct Simulation Monte Carlo (DSMC) method, which is a particle-based method for tracking particle trajectories and collisions as a model of a multi-species gas. The main component of SPARTA is a simulation code which allows the user to specify a simulation domain, populate it with particles, embed triangulated surfaces as boundary conditions for the flow, overlay a grid for finding pairs of collision partners, and evolve the system in time via explicit timestepping. The package also includes various pre- and post-processing tools, useful for setting up simulations and analyzing the results. The simulation code runs either in serial on a single processor or desktop machine, or can be run in parallel using the MPI message-passing library, to enable faster performance on large problems.

Plimpton, Steve↗

BDEM (Discrete-element-simulator for high-solids granular flows) [SWR-22-72]

BDEM is a discrete element method based simulation tool developed specifically for modeling high-solids granular flows that include polydispersity, heat-transfer, moving boundaries and chemistry. Our solver provides facilities for simulating spherical/non-spherical particles with modified contact and friction models in complex dynamic geometries defined using level-sets or triangulated files. The solver is developed on top of NREL's open-source performance portable library, AMReX, providing parallel execution capabilities on current and upcoming high-performance-computing (HPC) architectures. Simulations at the scale of several millions to billion particles have been performed using this software on large scale computing resources. This software can be applied to non-reacting solids dominant flows in silos, hoppers and screw conveyors as well as in high temperature reacting systems such as screw kilns and auger reactors.

Sitaraman, Hariswaran↗

pnnl/pyraabe

Automated Raabe table generationPyRaabe is a Python package to automate Raabe table -- a graph representation of airway geometry -- generation from a triangulated surface of an airway geometry. With a single command, it extracts a centerline from an input 3D surface mesh and subsequently computes the relevant attributes for the Raabe table, including length, diameter, bifurcation angle, and gravity angle. These can be used to inform downstream models, such as the Multiple-Path Particle Dosimetry (MPPD) model.

Colby, Sean M.↗

Three-dimensional profiling using the Fourier transform method with a hexagonal grating projection

We present three-dimensional profilometry based on triangulation in which a hexagonal pattern is projected on the object. To obtain an accurate result with a one-shot photographic image, the Fourier transform method and method of excess fraction are adopted. The three grating components of the hexagonal pattern are used. For compactness a new pattern projection scheme is introduced. The experimental results show that the constructed optical system works well for measuring the profile of a mannequin with a height resolution of {approx} {+-} 1 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Doppler sensor employing a single fan-shaped interference fringe system for distance and shape measurement of laterally moving objects

For monitoring the position and shape of fast moving and, especially, rotating objects such as turbo machine rotors, contactless and compact sensors with a high measurement rate as well as high precision are required. We present for the first time, to the best of our knowledge, a novel laser Doppler sensor employing a single fan-shaped interference fringe system, which allows measuring for the position and shape of fast moving solid bodies with known tangential velocity. It is shown theoretically as well as experimentally that this sensor offers concurrently high position resolution and high temporal resolution in contrast to conventional measurement techniques, since its measurement uncertainty is, in principle, independent of the object velocity. Moreover, it can be built very compact, because it features low complexity. To prove its operational capability and its potential for practical applications, radial and axial shape measurements of rotating bodies are demonstrated in comparison with triangulation. An average position resolution of about 2 {mu}m could be achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗