Search NASA⌕ Search

SEARCH · Search NASA

Results for “usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Learning from Five-year Resource-Utilization Data of Titan System

Titan was the flagship supercomputer at the Oak Ridge Leadership Computing Facility (OLCF). It was deployed in late 2012, became the fastest supercomputer in the world and was retired on August 2, 2019. With Titan's mission complete, this paper provides a first-order examination of the usage of its critical resources (CPU, Memory, GPU, and I/O) over a five-year production period (2015-2019). In particular, we show quantitatively that the majority of CPU time was spent on the large-scale jobs, which is consistent with the policy of driving ground-breaking science through leadership computing. We also corroborate the general observation of the low CPU-memory usage with 95% jobs utilizing only 15% or less available memory. Additionally, we correlate the increase of total job submissions and the decrease of GPU-enabled jobs during 2016 with the GPU reliability issue which impacted the large-scale runs. We further show the surprising read/write ratio over the five-year period, which contradicts the general mindset of the large-scale simulation machines being “write-heavy”. This understanding will have potential impact on how we design our next-generation large-scale storage systems. We believe that our analyses and findings are going to be of great interest to the high-performance computing (HPC) community at large.

Wang, Feiyi↗

Empirical Investigations of the Opportunity Limits of Automatic Residential Electric Load Shaping

Residential electric load shaping is often modeled as infrequent, utility-initiated, short-duration deferral of peak demand through direct load control. In contrast, modeled herein is the potential for frequent, transactive, intraday, consumer-configurable load shaping for storage-capable thermostatically controlled electric loads (TCLs), including refrigerators, freezers, and hot water heaters. Unique to this study are 28 months of 15-minute-interval observations of usage in 101 homes in the Pacific Northwest United States that specify exact start, duration, and usage patterns of approximately 25 submetered loads per home. The magnitudes of the load shift from voluntarily-participating TCL appliances are aggregated to form hourly upper and lower load-shaping limits for the coordination of electrical generation, transmission, distribution, storage, and demand. Empirical data are statistically analyzed to define metrics that help quantify load-shaping opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of network sharing in multi-core architectures.

As commodity components continue to dominate the realm of high-end computing, two hardware trends have emerged as major contributors-high-speed networking technologies and multi-core architectures. Communication middleware such as the Message Passing Interface (MPI) uses the network technology for communicating between processes that reside on different physical nodes, while using shared memory for communicating between processes on different cores within the same node. Thus, two conflicting possibilities arise: (i) with the advent of multi-core architectures, the number of processes that reside on the same physical node and hence share the same physical network can potentially increase significantly, resulting in increased network usage, and (ii) given the increase in intra-node shared-memory communication for processes residing on the same node, the network usage can potentially decrease significantly. In this paper, we address these two conflicting possibilities and study the behavior of network usage in multi-core environments with sample scientific applications. Specifically, we analyze trends that result in increase or decrease of network usage, and we derive insights into application performance based on these. We also study the sharing of different resources in the system in multi-core environments and identify the contribution of the network in this mix. In addition, we study different process allocation strategies and analyze their impact on such network sharing.

99 GENERAL AND MISCELLANEOUS↗

A Machine Learning–Based Tire Life Prediction Framework for Increasing Life of Commercial Vehicle Tires

In the commercial freight industry, tire retreading decisions are often conservative due to limited knowledge of a tire’s remaining service life. This practice leads to increased costs and material waste. This paper proposes a machine learning–based approach for estimating tire casing life and retreadability, focusing on usage data rather than wear information. This approach could extend the tire’s lifespan and reduce landfill waste. Data integration from diverse tire casing measurement sources presents challenges, including imbalanced removal data. Our methodology addresses these challenges by using historical inspection, telematics, and finite element modeling (FEM) datasets. We introduce “Tire Casing Energy” as a comprehensive usage input and apply a Variance-Reduction Synthetic Minority Oversampling Technique (VR-SMOTE) for data imbalance rectification. A random forest model is used to estimate the state of the tire casing and the casing removal probability, with Bayesian optimization applied for hyperparameter tuning, enhancing model accuracy. Here, the proposed prediction framework is able to differentiate different truck fleets and tire locations based on their usage parameters. With the aid of this machine learning model, the importance and sensitivity of different tire usage parameters can be obtained, which is beneficial to maximize tire life.

Data balancing↗

Generate Optimized Genetic Rhythm for Enzyme Expression in Non-native systems

Most amino acids are represented by more than one codon, resulting in redundancy in the genetic code. Silent codon substitutions that do not alter the amino acid sequence still have an effect on protein expression. We have developed an algorithm, GoGREEN, to enhance the expression of foreign proteins in a host organism. GoGREEN selects codons according to frequency patterns seen in the gene of interest using the codon usage table from the host organism. GoGREEN is also designed to accommodate gaps in the sequence.This software takes for input (1) the aligned protein sequences for genes the user wishes to express, (2) the codon usage table for the host organism, (3) and the DNA sequence for the target protein found in the host organism. The program will select codons based on codon usage patterns for the target DNA sequence. The program will also select codons for “gaps” found in the aligned protein sequences using the codon usage table from the host organism.

Source record↗

Missile Captive Carry Monitoring and Helicopter Identification Using a Capacitive Microelectromechanical Systems Accelerometer

Military missiles are exposed to many sources of mechanical vibration that can affect system reliability, safety, and mission effectiveness. The U. S. Army Aviation and Missile Research Development and Engineering Center (AMRDEC) has been developing missile health monitoring systems to assess and improve reliability, reduce life cycle costs, and increase system readiness. One of the most significant exposures to vibration occurs when the missile is being carried by a helicopter or other aviation platform, which is a condition known as captive carry. Recording the duration of captive carry exposure during the missile’s service life can enable the implementation of predictive maintenance and resource management programs. Since the vibration imparted by each class of helicopter varies in frequency and amplitude, tracking the vibration exposure from each helicopter separately can help quantify the severity and harmonic content of the exposure. Under the direction of AMRDEC staff, engineers at the Pacific Northwest National Laboratory have developed a Captive Carry Health Monitor (CCHM) for the Hellfire II missile. The CCHM is an embedded usage monitoring device installed on the outer skin of the Hellfire II missile to record the cumulative hours the host missile has been in captive carry mode. To classify the vibration by class of helicopter, the CCHM analyzes the amplitude and frequency content of the vibration with the Goertzel algorithm to detect the presence of distinctive rotor harmonics. Cumulative usage data are accessible in theater from an external display; monthly usage histograms are accessible through an internal download connector. This paper provides an overview of the CCHM electrical and package design, describes field testing and data analysis techniques used to monitor captive carry identify and the class of helicopter, and discusses the potential application of missile health and usage data for real-time reliability analysis and fleet management.

Goertzel, HUMS↗

Truck Technology Efficiency Assessment (TTEA) Project (Final Report)

Medium- and heavy-duty trucks and buses are responsible for over 28% of the energy used and emissions generated in highway transportation, and class 8 tractor-trailers operating in long-haul and regional cargo transport are responsible for about 75% of all fuel consumed by commercial trucks. The vehicle miles traveled (VMT) for trucks is expected to increase at a rate significantly outpacing passenger VMT growth, which will result in a steady rise in the percentage of energy consumption (and emissions) attributable to trucks over the coming decades. These facts have sparked significant recent interest in truck fuel efficiency in the transportation community. Although fuel economy regulations in the United States have historically focused on passenger cars, recent legislation requiring new standards for fuel economy in medium- and heavy-duty trucks aims to increase the efficiency of trucks as well. The development of regulations for truck fuel efficiency is quite challenging, however, since vehicle usage and configurations vary substantially among the very diverse set of trucking applications. Fuel economy is very strongly linked to the particular drive cycles followed by a given truck, as are the gains in efficiency that can realized by implementing new technologies. As demonstration of this fact, a technology that provides significant fuel efficiency gains for one trucking application may yield little improvement or could even be detrimental to fuel economy in a different trucking application. It is therefore critical that the usage of each application be well understood and carefully evaluated to select the set of technologies that can provide the greatest benefits for each application. Although it is well known that drive cycle data representative of a vehicle or fleet’s usage is crucial for an accurate evaluation of fuel economy benefits or to identify an optimum set of technologies to reduce fuel consumption, detailed drive cycle data of trucks are not readily available for many applications. The Oak Ridge National Laboratory (ORNL) has collected a rather extensive set of truck duty cycle data in an effort to characterize the usage of several trucking applications. During the first phase of ORNL’s duty cycle data collection activities, drive cycle measurements were made from six tractor-trailers during normal operations in a regional commercial shipping fleet, operating primarily in the southeastern U.S., for a period of a full year. This data, contained in the Heavy Truck Duty Cycle (HTDC) project database, was analyzed in detail for the current research effort in the Truck Technology Efficiency Assessment project. Based on the high fidelity HTDC duty cycle data, the results of this study are therefore highly representative of tractor-trailer operations for this type of regional, freeway-dominant trucking application.

LaClair, Tim J.↗

BLEMS (award #DE-EE0004019) Final Report

This project focused on the development and testing of a non-intrusive “bolt-on” solution called the Building Level Energy Management System (BLEMS) which reduces day-to-day electric energy consumption by at least 20% while maintaining or improving occupant comfort. BLEMS learns occupants’ energy usage behavior, and comfort preferences, as well as building system behavior and uses this information to reduce energy consumption and related greenhouse gas emissions, while simultaneously meeting occupants’ comfort and building usage needs (i.e., day-to-day energy usage goals, demand response energy usage levels, etc.). In BLEMS, humans and building systems and devices interact ubiquitously in real time through an integrated sensor and control system for reduced building electricity consumption. The solution enables bidirectional communication between building systems and occupants, obtains occupant input on comfort level preferences, and operates the building based on measured system response, occupant feedback, and predicted occupancy. Although designed to be used in any building, we focused on commercial buildings as they are a major consumer of HVAC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ceiling Fan and Ceiling Fan Light Kit use in the U.S.: Results of a Survey on Amazon Mechanical Turk

This report outlines the methods and results of an online survey conducted to quantify the use of residential ceiling fans and ceiling fan light kits in the United States (U.S.). Although a number of previous ceiling fan studies exist, most are at least a decade old and provide limited information on many aspects of ownership and usage. We surveyed people across the U.S. using Amazon Mechanical Turk, and we analyzed the surveys from 2550 people. We found ceiling fans hours of operation per day to be distributed bimodally with an arithmetic mean of 6.4 hours per day. We estimated the mean annual energy use per fan to be 99 kilowatt-hours. We also provide estimates of usage at each speed of operation, regional variance of usage, ceiling fan light kit characteristics, and several other topics. By providing usage details applicable to the whole country, this survey provides an important new piece of information for assessing the use of ceiling fans and ceiling fan light kits in the U.S

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recovery of Utility Fixed Costs: Utility, Consumer, Environmental and Economist Perspectives

Utilities recover costs for providing electric service to retail customers through a combination of rate components that together comprise customers’ monthly electric bills. Rates and rate designs are set by state regulators and vary by jurisdiction, utility and customer class. In addition to the fundamental tenet of setting fair and reasonable rates, rate design balances economic efficiency, equity and fairness, customer satisfaction, utility revenue stability, and customer price and bill stability. At the most basic level, retail electricity bills in the United States typically include a fixed monthly customer charge — a set dollar amount regardless of energy usage — and a volumetric energy charge for each kilowatt-hour consumed. The energy charge may be flat across all hours, vary by usage level (for example, higher rates at higher levels of usage), or vary based on time of consumption. While some utility costs, such as fuel costs, clearly vary according to electricity usage, other costs are “fixed” over the short run — generally, those that do not vary over the course of a year. Depending on your point of view, and whether the state’s electricity industry has been restructured or remains vertically integrated, the set of costs that are “fixed” may be quite limited. Or the set may extend to all capacity costs for generation, transmission and distribution. In the long run, all costs are variable. In the context of flat or declining loads in some regions, utilities are proposing a variety of changes to retail rate designs, particularly for residential customers, to recover fixed costs. In this report, authors representing utility (Chapter 1), consumer (Chapter 2), environmentalist (Chapter 3) and economist (Chapter 4) perspectives discuss fixed costs for electric utilities and set out their principles for recovering those costs. The table on the next page summarizes each author’s relative preferences for various options for fixed cost recovery, some of which may be used in combination. The specific design of any ratemaking option matters crucially, so a general preference for a given option does not indicate support for any particular application.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WCATS User's Guide

This manual has been written to provide a general reference of the usage of the Waste Compliance and Tracking System (WCATS). Because WCATS is designed to be used at many different kinds of facilities, much of the usage of the application is driven by the metadata configuration of the system. General usage of the system and the different types of tasks provided is included in this document, but custom usage and an exhaustive list of configuration options will not be provided. This manual is not intended to be a replacement for detailed work procedures or desk instructions, and it will not include configuration details such as service unit names, waste stream numbers for selection, etc. Any use of such information in this document is only provided as an example.

42 ENGINEERING↗

Waste Compliance and Tracking System (WCATS) User Guide (Release 2)

This manual has been written to provide a general reference of the usage of WCATS. Because WCATS is designed to be used at many different kinds of facilities, much of the usage of the application is driven by the metadata configuration of the system. General usage of the system and the different types of tasks provided is included in this document, but custom usage and an exhaustive list of configuration options will not be provided. This manual is not intended to be a replacement for detailed work procedures or desk instructions, and it will not include configuration details such as service unit names, waste stream numbers for selection, etc. Any use of such information in this document is only provided as an example.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydropower Infrastructure - LAkes, Reservoirs, and RIvers (HILARRI), v4

HILARRI is a database of links between major datasets of operational hydropower dams and powerplants, and inland water bodies. These connections are critical for conducting large-scale analysis of hydropower infrastructure and their associated natural and engineered water systems. Features include: – Dams from the National Inventory of Dams (2025) and the Global Reservoir and Dam Database (GRanD v1.3) – Hydropower plants from the Existing Hydropower Assets dataset (EHA 2025) – Power plants that are listed in the 2025 U.S. Hydropower Development Pipeline Data or were listed in previous versions of the dataset These hydropower infrastructure features are linked to several major datasets that provide hydrologic and hydraulic information relevant for analysis of hydropower systems that includes the integral water resources. That information comes from: – Products from the National Hydrography Dataset (NHD) – NHDPlusV2 Medium Resolution river network flowlines, – NHD waterbodies (limited to lakes and reservoirs), – NHD Watershed Boundary Dataset (HUC12-level for the Conterminous United States (CONUS)) – NHD High Resolution waterbodies – HydroLAKES water bodies (lakes and reservoirs) – LAGOS-US lakes and reservoirs – EPA National Lakes Assessment (2007, 2012, 2017, and 2022) – The Reservoir Sedimentation Database (RESSED) – EPA SuRGE sampling locations Unique identifiers are used to facilitate joining to the original full datasets. For example, characteristics of NHD flowlines such as estimated average flow rate can be joined from the NHDPlusV2 dataset to a dam or power plant listed in HILARRI based on the ID field, “COMID”, that is common to both datasets. HILARRI only includes basic information about identifiers, location, and data quality or usage notes. It does not contain the attributes or time series data associated with these sites. The HILARRI dataset incorporates information from several datasets to facilitate more effective and accurate analysis of hydropower infrastructure and their associated waterbodies. For example, dams were checked against the most recent American Rivers Dam Removal Database to identify and flag facilities that may no longer exist. Additionally, dams that are listed multiple times in the NID are identified and flagged to avoid double-counting when analyzing and summarizing information. Other quality flags include certainty of operational hydropower (i.e., if one or more datasets indicates hydropower at a particular location), whether an associated water body is accurate or composed of multiple polygons, or whether there is a known issue with reported characteristics in one of the underlying datasets. These additional data flags are designed to increase confidence in data usage for individual to large-scale analyses.

Hansen, Carly [ORNL] (ORCID:0000000193280838)↗

Method and apparatus for routing data in an inter-nodal communications lattice of a massively parallel computer system by dynamic global mapping of contended links

A massively parallel nodal computer system periodically collects and broadcasts usage data for an internal communications network. A node sending data over the network makes a global routing determination using the network usage data. Preferably, network usage data comprises an N-bit usage value for each output buffer associated with a network link. An optimum routing is determined by summing the N-bit values associated with each link through which a data packet must pass, and comparing the sums associated with different possible routes.

42 ENGINEERING↗

CoNNECT: Citizen Engagement for Energy Efficient Comunities

The CoNNECT system is a home energy management software system developed to provide the public and electric utilities access to timely, useful, and actionable information about energy usage (that is, usage data for electricity, water, gas, and others). CoNNECT for the public provides the utility customers access to historical usage data; permits visual correlation between weather and consumption patterns; compares customers’ consumption data to that of their peers (customers living in houses of similar size, age, and household size); and provides information for actions using generic appliance data. Utility customers can customize their information for action by contributing data about their appliances. CoNNECT for the utility provides electric utility analysts access to additional data, such as building envelope data, which they naturally do not have access to; permits easy decision making through the generation of usage “heat-maps” for global comparison and assessment; and permits the clustering of customers based on user-defined criteria.

Omitaomu, Olufemi↗

Real-time forecasting of electricity demand in a streams-based architecture with applications

A streams platform is used. Multiple streams of electricity usage data are received, each from an electrical meter providing periodic updates to electrical usage for devices connected to the electrical meter. Weather information is received corresponding to locations where the electrical meters are. Real-time predictive modeling of electricity demand is performed based on the received multiple streams of electricity usage data and the received weather information, at least by performing: updating a state space model for electrical load curves using the usage data from the streams and the weather, wherein the updating uses current load observations for the multiple streams for a current time period; and creating forecast(s) for the electricity demand. The forecast(s) of the electricity demand are output. Appliance-level predictions may be made and used, and substitution effects and load management functions may be performed.

Ghosh, Soumyadip↗

Real time trajectory optimization for hybrid energy management utilizing connected information technologies

The disclosure is directed to solving a full trajectory optimization problem in real-time for a hybrid electric vehicle (HEV) such that future driving conditions and energy usage may be fully considered in determining optimal engine energy usage and battery energy usage in real-time during a trip. An electronic control unit of the HEV may be configured to: receive route information for a route to be driven by the HEV; and after receiving the route information, iterating the operations of: measuring a current state of charge (SOC) of the battery; using at least the measured SOC and an initial co-state value stored in a memory, performing a process to iteratively update the co-state value to obtain an updated co-state value; using at least the updated co-state value, computing an updated control value; and applying the updated control value to control a usage of the battery and the internal combustion engine.

Huang, Mike X.↗