Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗

The Cost of Floating Offshore Wind Energy in California Between 2019 and 2032

California’s energy planning is centered around meeting the emissions reduction and renewable energy requirements of Senate Bill 350 by 2030. However, state power system planning is expected to eventually address California’s requirement to achieve 100% of total retail electricity sales from renewable energy and zero-carbon resources by 2045, as mandated by Senate Bill 100. To comply with these directives, California needs to investigate the further development of energy efficiency, storage, and a diverse range of renewable energy, zero-carbon emission, and transmission resources, including offshore wind. Wind resources off the coast of California have the potential to generate a significant portion of the state’s electric energy as it moves toward a zero-carbon economy and can help diversify its energy mix. Floating offshore wind technology, which is suitable for the deep waters along the California coast, is currently in a precommercial phase, with approximately 84 megawatts (MW) installed worldwide at the end of 2019. Globally there are over 7,000 MW in planning and permitting phases of development, with the first commercial-scale projects expected to be operational in 2024. This study provides site-specific cost and performance data for floating offshore wind to inform California’s long-term energy planning. The identification of new resources to meet California’s policy goals at least cost is part of the Integrated Resource Planning (IRP) process, which is coordinated by the California Public Utilities Commission (CPUC). In 2019–2020 IRP modeling, offshore wind was included for the first time as a candidate resource in some sensitivity cases (CPUC 2019). The data and information presented in this report can be used to update offshore wind inputs in future IRP cycles. The authors conducted a geospatial cost analysis over portions of the offshore wind resource area of California. The analyzed spatial domain includes sites with a mean wind speed of at least 7 meters per second and water depths between 40 meters (m) and 1,300 m. Costs and energy production vary across this analysis domain. We calculated these parameters on a grid layout with over 750 sites, with each site representing a 1,000-MW commercial offshore wind power plant. Levelized cost of energy (LCOE) was calculated at each site over the analysis domain. The resulting variation in LCOE across the analysis domain is illustrated through heat maps in this report. Five study areas were selected within the analysis domain where more detailed cost analysis was conducted and cost parameters, such as annual energy production, capital cost expenditures (CapEx), operational cost expenditures (OpEx), and net capacity factors are reported. These five study areas include Morro Bay, Diablo Canyon, Humboldt, Cape Mendocino and Del Norte.

17 WIND ENERGY↗

End-Use Load Profiles for the U.S. Building Stock

The End-Use Load Profiles for the U.S. Building Stock project uses New ResStock and ComStock models to statistically represent the energy use of U.S. buildings. The project's hybrid approach combines best-available ground truth data, such as submetering studies and statistical disaggregation of whole-building interval meter data, with the reach, cost-effectiveness, and granularity of physics-based and data-driven building stock modeling to deliver a nationally-comprehensive data set at a fraction of the historical cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Effect of Prosumer Duality on Power Market: The Effect of Market Regulation

Electricity prosumers are energy subsystems that not only consume, but also produce electricity. They are present in distribution level networks as traditional utility customers who have installed distributed energy resources. They are also present in transmission level networks as large conglomerates own both generation assets and large industrial loads. Previous work on the economics of prosumers has demonstrated that prosumers in a market have incentives to behave more competitively compared to producers and consumers in traditional markets. This paper further explores the behavior of prosumers and their response to market policies including the allocation of network losses and the impact of net metering. We extend a Cournot model of a dual prosumer and find that prosumers respond with higher supply quantities if network losses are allocated to demand base. They respond with lower supply quantities if network losses are allocated to supply base. Allocating network losses to demand base also causes equilibrium prices to decline. Markets where prosumers first satisfy their own load and then sell the balance of electricity to the grid have lower quantities and higher prices compared to markets where prosumers buy and sell at locational marginal price.

Tsybina, Eve↗

Grid-interactive Efficient Buildings Projects Summary

Through its grid-interactive efficient building (GEB) research, DOE’s Building Technologies Office seeks to build on existing energy-efficiency efforts to optimize the interplay among energy efficiency, demand response, behind-the-meter generation and energy storage to increase the flexibility of demand-side management. BTO envisions a future where buildings dynamically operate as part of a low cost, reliable electricity grid while meeting the needs and expectations of building occupants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Measurement of the QE Map

113 MHz SRF gun utilized CsK 2 Sb and Na 2 KSb cathodes, which were irradiated with a pulsed green laser with a wavelength of 0.53 microns. The drive laser generated 78 kHz pulses with an acousto-optic modulator selecting the desired number of pulses reaching the cathode. The operator can select the aperture size, defining the laser spot diameter on the cathode, and the power level, which is controlled by a rotating polarizer. The laser power reaching the cathode can be measured with a meter based on a photodiode. The quantum efficiency (QE) of a photocathode serves as a primary indicator of its state. Small QE renders the cathode unusable when the desired bunch charge cannot be achieved. Strong variations in the quantum efficiency on the cathode surface might lead to the growth of the beam emittance due to the space charge effects. We have created a routine to measure the distribution of the QE on the cathode. The operator selects the aperture size, the central spot location, and the scan ranges for both planes. The scan starts from the central spots and proceeds along a spiral-like trajectory, making N rounds. The number of rounds can be chosen, and the total number of measured points is (2N+1) 2 . The laser spot movement is shown in Fig. 1.

43 PARTICLE ACCELERATORS↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (DEMO-FTES) [Abstract]

Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.

25 ENERGY STORAGE↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging (Phase III)

Due to rapidly changing sky conditions, the available solar irradiance for energy generation is subject to wide swings in amplitude. As the market penetration of solar energy continues to increase rapidly, these variations in solar power generation are beginning to have an impact on grid stability and increased wear on power switches. Solar power forecasting plays a critical role in operations for Independent System Operators (ISOs) and utilities. Accurate forecasts help maintain grid reliability, optimize generation from renewables, and reduce operating costs. Of particular interest to the ISOs and utilities are sudden changes in solar irradiance, termed “ramp events,” due to the movement of clouds. One significant impact of ramp events on the grid is additional ancillary service requirements necessary to manage such variability. Ramp events can also cause voltage fluctuations in the distribution grids and trigger actions of automated line equipment (e.g., tap changers), leading to additional maintenance costs. In high penetration solar regions, forecasts must be made for both transmission-connected and distribution-connected resources – either behind the meter or in front of it. Particularly for distributed solar energy resources, forecasting can be a challenge due to the lack of visibility of the energy resource. Brookhaven National Laboratory (BNL) has been working towards nowcasting Global Horizontal Irradiance (GHI) using low-cost technologies for several years now. The Solar NowCasting technology being developed by BNL is a 0 – 30 min solar “nowcasting” technology applicable to a scale covering both large generating facilities and residential, distributed solar installations that relies on a network of ground-based high-definition (HD) cameras and surface pyranometers. GHI forecasts are being produced for both regions using 8 ground-based HD cameras and at least 2 surface pyranometers. When stitched together, the camera images can be used to forecast the impact of clouds on available solar irradiance over a domain of ~50 km 2 . Phase I of the project was the engineering scale up conceptual design stage. Phase II was the initial field test and demonstration, in which the technology was scaled up by a factor of 20 times and successfully demonstrated in eastern Long Island. In Phase III, an additional forecasting network was added in upstate NY and both networks are currently being operated until at least a full year of data is gathered by the Albany network to allow for the collection of sufficient data to evaluate performance against the persistence and smart persistence models using the Solar Arbiter.

14 SOLAR ENERGY↗

Bay Area Regional Energy: Network Integrated Commercial Retrofits (BRICR) Project. Final Report

The BRICR project applied large-scale building energy modeling concepts with the aim of reducing the cost of energy efficiency targeting, design, and project development, and measurement of energy savings for energy efficiency programs implemented by local governments that serve small and medium commercial buildings (SMB). The project leveraged the services and resources of existing local government energy programs serving disadvantaged and hard-to-reach SMB customers. In contrast to programs run by utilities, local government programs generally do not have direct access to energy billing records for an entire class of customers in a geographic area, which prior research demonstrated useful for large-scale building energy model baseline development and calibration. , However, local governments are rich in public records that offer important clues about physical attributes and uses that, along with behavior, determine energy use. Relying only on public records, BRICR demonstrated development of credible baseline energy models for 3,792 office, retail, and hotel buildings. Publicly disclosed annual energy use data from a local energy benchmarking program and anonymized data from the Building Performance Database, the nation’s largest dataset about energy-related characteristics of buildings, were utilized to validate and calibrate energy models via an innovative method comparing distributions of energy intensity by fuel type for portfolios of buildings of similar size, vintage, and use. Portfolio calibration does not provide certainty that an energy model fits an individual building; the method is useful when billing data is not accessible – a common situation for researchers, energy service providers and ESCOs, local governments, and any party other than a utility. A software component was developed, the BRICR gem, which automates simulation when relevant data is added or edited by the user to a file saved in the standardized BuildingSync XML schema for energy audit data. The component was demonstrated as a simplified means to generate a mass of energy models corresponding to public records containing basic attributes such as building scale, location, use, year built, and aspect ratio in combination with building energy code prototype data corresponding to use and vintage. The component was also demonstrated as a simplified means to automate energy simulation when attributes are revised; the intention was to enable iterative improvement of the baseline model and energy savings estimates for common energy conservation measures as users revise relevant attributes based on their observations. In the context of institutional change and uncertainty for the participating local government energy programs, 13 whole building retrofits were completed. Impacts were measured by applying the CalTRACK2.0 methods to standardize measurement of normalized metered energy consumption. The GRIDMeter methods of stratified sampling and individual load shape analysis were applied to adjust for impacts of the effect of COVID-19 on retrofitted buildings in the context of all local buildings of similar size and use. Excluding impacts of the pandemic, retrofitted buildings demonstrated between 1.6% and 25.1% reduction in energy use. The project contributed use cases and feedback that helped inform evolution of the software tools and data formats that were combined for the first time in the BRICR project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Polymer-based microfluidic device for on-chip counter-diffusive crystallization and in situ X-ray crystallography at room temperature

Proteins are long chains of amino acid residues that perform a myriad of functions in living organisms, including enzymatic reactions, signalling, and maintaining structural integrity. Protein function is determined directly by the protein structure. X-ray crystallography is the primary technique for determining the 3D structure of proteins, and facilitates understanding the effects of protein structure on function. The first step towards structure determination is crystallizing the protein of interest. We have developed a centrifugally-actuated microfluidic device that incorporates the fluid handling and metering necessary for protein crystallization. Liquid handling takes advantage of surface forces to control fluid flow and enable metering, without the need for any fluidic or pump connections. Our approach requires only the simple steps of pipetting the crystallization reagents into the device followed by either spinning or shaking to set up counter-diffusive protein crystallization trials. The use of thin, UV-curable polymers with a high level of X-ray transparency allows for in situ X-ray crystallography, eliminating the manual handling of fragile protein crystals and streamlining the process of protein structure analysis. We demonstrate the utility of our device using hen egg white lysozyme as a model system, followed by the crystallization and in situ, room temperature structural analysis of the hub domain of calcium–calmodulin dependent kinase II (CaMKIIβ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Energy Efficiency and Performance Evaluation of Self-Contained, Medium Temperature, Reach-In Refrigerated Display Cases

This project was part of an effort by Commonwealth Edison Company (ComEd) to evaluate the energy and peak demand saving potential of emerging technologies in the Chicago area. This document focuses on the assessment of energy-efficient, medium-temperature, self-contained refrigerated display cases utilizing environmentally friendly refrigerants. The results of this evaluation will be considered by CLEAResult to develop a new energy efficiency rebate measure for ComEd's incentive programs. This rebate measure will become an addition to the Technical Reference Manual (TRM). In 2016, the United Nations passed the Kigali Montreal Protocol Amendment which placed restrictions on certain types of refrigerants. In compliance with this amendment, the US Environmental Protection Agency (EPA) placed a ban on the manufacture of refrigeration systems using hydrofluorocarbons including R134a starting in January 2020. Although the ban has halted manufacture, the EPA continues to allow the use of these refrigerants. Therefore, it is critical to provide incentives for replacing these refrigerants with other environmentally friendly and energy-efficient alternatives. The energy-efficient refrigerator cases evaluated here (referred to as EE Case A and B) contain environmentally-friendly refrigerants in compliance with the EPA hydrofluorocarbon ban. These consist of natural refrigerant propane (R290), and HFC drop-in hydrofluoroolefin R513a, respectively. These cases also contain other energy-efficient components including efficient lighting, more robust evaporator and condenser fans and different-sized heat exchangers. EE Case A is also built with materials that better insulate the case, which improves energy efficiency. To ascertain the energy efficiency contribution of these design components, the consumption of the evaporator and condenser fan motors, compressor, and lighting/controller were evaluated individually. The medium-temperature, self-contained reach-in refrigerated display case was selected due to its widespread use in convenience stores and small supermarkets. Self-contained refrigeration has also seen increased use in restaurants due to curbside pickup during the COVID-19 pandemic. For this study, the refrigerated display cases' performance was evaluated in a controlled environmental chamber at representative indoor dry-bulb and humidity conditions found in supermarkets within ComEd's service territory climate zone. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 method of testing. However, modifications to the ANSI/ASHRAE test methodology were implemented to better represent customer operation of the units. In addition to the indoor supermarket conditions, the cases were also evaluated at the "upper target," or environmental conditions used in ANSI/ASHRAE 72-2018. The case total power and case components were metered to obtain their daily power (kW) and energy consumption(kWh). The cases were filled with thermal filler mass to replicate thermal mass of product loading. Additionally, product simulators were used to provide product temperature information. Door actuators were mounted to each of the cases' three doors to replicate regular door openings and effects of shopper traffic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tides on South Mill Apartment Complex

This dataset includes data from the building management system for a large multi-family rental property located in Tempe, Arizona. The name of this rental property is “Tides on South Mill” and it is owned by the FCP which is a real-estate investment company based in Maryland with a large portfolio of rental properties that spreads out throughout the U.S. FCP’s portfolio includes large multi-family housing and commercial buildings. The property is split into four quadrants. Each quadrant has roughly 130 apartments. The total floor area of each Quadrant is about 94,000 sq. ft. The campus of Solara spreads over 27 acres. The mechanical system consists of a 2-pipe system that runs chilled or hot water thru individual Fan Coil Units depending upon the season. The gas-fired boiler will supply hot water when seasonal change-over will take place. This dataset spans October to December 2021 and includes time-series measurements corresponding electricity meter data (Cooling Tower Fan, Pumps, Chillers,) with 1-minute resolution, chilled water temperature data and outside air data with 5-minute resolution etc. as CSV files. In addition to the measurements, a metadata .json file, and a .pdf dataset description file are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Textile Carbon Fiber Packaging and NCF Production

This Technical Collaboration Project focused on packaging large tow (≥ 10 grams/meter) textile carbon fibers, for which currently there is no suitable method. Prior to this project, Oak Ridge National Laboratory (ORNL) used a crude packaging approach to deliver (approximately) 100-meter packages for evaluation by intermediates producers, composites fabricators and other collaborators. That packaging approach was simply a hoop wrap on a standard 75 mm (3 inch) cardboard tube, with paper interleaved between layers and little or no tension control during spooling. While this approach was very effective for initial fiber development and sample fiber and small composite sample evaluation, these packages were inadequate for larger-scale demonstrations and more extensive applications development. The paper-interleaved packages were inconsistent, wasteful, and too small for commercial utilization; they were designed as a quick and simple means to package material for delivery into prototyping operations and were never expected to satisfy industrial requirements for commercial production. This project aimed to develop a commercially relevant approach for packaging large tow textile carbon fibers for robust delivery into downstream commercial intermediates and composites production operations. The development of robust packaging equipment that delivers packages meeting industrial requirements is essential to commercial implementation. In this project, the team identified packaging requirements, created a design, and prototyped a new packaging concept at ORNL’s Carbon Fiber Technology Facility (CFTF) and resulting packages were tested in production of non-crimp fabric (NCF).

42 ENGINEERING↗

Analysis of the Feasibility of UAS-Based EMI Sensing for Underground Utilities Detection and Mapping

This paper investigates the feasibility of using a linear current sensing (LCS) technique integrated on an unmanned aerial system (UAS) for detecting and mapping underground infrastructure rapidly and cost-effectively. The LCS technique is based on data from a wide band of electromagnetic induction frequencies (50 kHz to 2 MHz) using a vector magnetic field gradiometer. This technique takes advantage of a slowly decaying secondary magnetic field in order to achieve greater standoff detection distance ($\frac{1}{R^2}$ vs. $\frac{1}{R^6}$ for compact metallic targets during EMI sensing, where R is the distance from a target to the sensor). These secondary magnetic fields are produced by the excite current on long conductors, allowing detection at a distance of 10 meters or more. The system operates between tens of kHz to a few MHz and uses either an active EMI source or existing EM fields to excite this linear current on a long metallic subsurface target. Once excited, these linear currents produce a secondary magnetic field that is detected with an above ground triaxial magnetic field gradiometer. By moving and tracking its geolocation, the system outputs rich datasets sufficient to support high-fidelity forward and inverse EMI models for estimating the depth and orientation of deep underground long linear metallic infrastructure. The system’s hardware and its integration to a UAS system are outlined, along with the formulation of LCS theory, and numerical and experimental data are presented. The results illustrate that the LCS technique offers large standoff detection, is adaptable to UAS, and could be used effectively for detecting deep underground infrastructure such as wires and pipes.

54 ENVIRONMENTAL SCIENCES↗

Techno-economic analysis of roll-to-roll production of perovskite modules using radiation thermal processes

Perovskite solar technology can produce economically viable photovoltaic devices due to low cost of materials and scalable manufacturing. Solution phase deposition of all active layers lends itself to roll-to-roll fabrication methods which are well-established and have production rates of several hundred square meters per minute. In this techno-economic analysis, the opportunity to scale at this production throughput is considered with manufacturing rates exceeding one gigawatt per year in a single plant. Intense pulsed light is used for the post deposition process to minimize costs associated with the footprint, equipment, and operation. The analysis is limited to the operation of a roll-to-roll manufacturing facility producing a perovskite solar film that can be incorporated into photovoltaic modules. Costs associated with materials, labor, and equipment are considered along with utilities determined from the fundamental engineering calculations. Furthermore, the results show that at very large-scale operations of several gigawatts, the costs to produce the solar films range between $0.04-$0.10 per watt.

14 SOLAR ENERGY↗

Beam Loss Monitoring with Fixed and Translating Scintillation Detectors Along the Fermilab Drift-tube Linac

The Fermilab Linac is a roughly 145 meter linear accelerator that accelerates H- beam from 750 keV to 400 MeV and provides beam for the Booster and the rest of the accelerator chain. The first section of the Linac is a Drift-Tube Linac (DTL), which in its current state, suffers from a lack of instrumentation along its length. As a result, operational staff do not have access to the diagnostic information needed to tune the critical components of this accelerator, such as the quadrupole magnets within the drift tubes. This work presents an effort to utilize both fixed and translating scintillation detectors to investigate beam loss along the first two cavities of the DTL.

43 PARTICLE ACCELERATORS↗